Suresh Kumar Ahirwar
Municipal Corporation Gwalior
(Vishesh Nidhi) Construction of Community Hall Wark at Village Neem Chandoha Shivpuri Link Road.Ward 59.Zone 13 File No.29/26X3/3.
2026_UAD_486060_1
MPGMC/29/26X3/3/Jan/2025-26
Open Tender
Civil Works - Others
90 days
Jankarya Department
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹8,451
15 Apr 2026
27 Feb 2026
18 Mar 2026
28 Feb 2026
16 Mar 2026
9 Mar 2026
2.6 Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead up to 50m.Disposed earth to be levelled and neatly dressed. 2.6.1 All kinds of soil Cum 151.0
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level. Cement concrete grade M-10 (Nominal Mix) with 20 mm maximum size of stone aggregate
1.0 Transportation by Mechanical means including loading, unloading and stacking
2.18 Supplying and filling in plinth under floors including, watering, ramming consolidating and dressing complete. 2.18.1 Moorum/Hard copra Cum 478.00
7.1Randomrubblemasonrywithhardstoneinfoundation andplinthwith Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 3724.00
5.1 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.1Cement concrete grade M20 (Nominal Mix)with 20mm maximumsize of stone aggregate. Cum 5435.00
6.3 Brick work with chimenybrick of class designation40 in superstructure above plinth level upto floor 2 level including the cost of scaffolding in : 6.3.1 Cement mortar 1:4(1 cement : 4 coarse sand) Cum 5209.00
19.1 Centering and shuttering including strutting, propping stretching etc. complete for and removal of formworkbysheet plateor plywood shuttering for : 19.1.1 Foundations, footings, bases of columns, etc. For mass concrete. Sqm 160.00
19.1 Centering and shuttering including strutting, propping stretchingetc. complete for and removal of formworkbysheet plateor plywoodshuttering for : 19.1.6 Columns, Pillars, Piers, Abutments, Posts and Struts. Sqm 362.00
19.1 Centeringandshuttering includingstrutting, proppingstretchingetc.complete for and removal of formworkbysheet plateor plywood shuttering for : 19.1.4 Shelves (Cast in situ) Sqm 305.00
19.1 Centeringandshuttering includingstrutting, proppingstretchingetc. complete for and removal of formworkbysheet plateor plywood shuttering for : 19.1.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. Sqm 270.00
5.11 Reinforcement for R.C.C. work including straightening, cutting, bending, placinginpositionand bindinguptofloor level including cost of binding wire, wast ageandover lapsup to 12 mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels,up to 4.5mvertical lengthof reinforcement inwallcolumns(over lapsshallbeprovidedasperrequirementof IS:13920; IS456&SP: 34) etc. complete. 5.11.4 Thermo-Mechanically Treated bars. (Fe 500 D or more) kilogram 58.00
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, postsandstrutsetc.above plinth level and up to floor two level excluding cost of centering, shuttering and reinforcement etc. 5.2.1 Cement concrete grade M20(Nominal Mix)with20 mm maximumsize of stone aggregate. Cum 5656.00
5.3 Reinforcedcement concrete work inbeams, suspendedfloors, roofs havingslopeup to15° landings, balconies, shelves, chajjas, lintels, bands,plainwindowsills,staircasesandspiralstaircases up to floor two level excluding thecostofcentering, shuttering andrein for cement with Cement concrete gradeM-20 (Nominal Mix) with20mm maximum size of stone aggregate.
2.16 Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm indepth, consolidating eachdeposited layer by ramming andwatering, leadup to50mand lift upto 1.5 m.
13.2 15 mm cement plaster on rough side of single or half brick wall of mix 13.2.1 1:4 (1 cement: 4 sand) Sqm 174.00
13.1 12 mm cement plaster of mix : 13.1.1 1:4 (1 cement: 4 sand) Sqm 149.00
13.23 Providing and applying plaster of paris puttyof 2mm thickness over plastered surface to prepare the surface even and smooth complete Sqm 87.00
13.39 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work Sqm 58.00
10.14.1Steelworkweldedinbuiltupsections/framedworkincluding cutting,hoisting, fixing inpositionand applying apriming coat of approved steel primer using structural steel etc. as required.10.14.1.2In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
22.10ProvidingandlayingbelowgroundunplasticisedPVCpipetowithstandworkingpressureof4kg/cm2soildwastepipesconfirmingtoIS:13592andIS:4985includingjointingwithseal ringconfirmingtoIS:5282 leaving10mmgap for thermal expansionall necessary fittings etc. complete. Excavation to be paid seperataly.22.10.1 110 mm diameter OD Meter 217.0
10.5 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mmM.S. gusset plates at the junctionsand corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 10.5.1 Using M.S. angels 40x40x6 mm for diagonal braces. Sqm 2691.00
13.46.3PaintingSteelworkwithDeluxeMultiSurfacePainttogiveanevenshade.Twoormorecoatapplied@0.90ltr/10sqmoveranundercoatof primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture Sqm 68.00
11.34ProvidingandlayingrectifiedGlazedCeramicwalltiles300x450mmormore(8mmto10mmthick)of1stqualityconforming to IS : 15622 ofapprovedmake in all colours, laid on12mmthickCementMortar1:3(1Cement : 3Coarsesand) includinggrauting the jointswithwhitecement and matching pigments etc., complete. Sqm 820.00
11.33 Providingand layingrectifiedGlazedCeramic floor tiles300x300mmor more(8mmto10mmthick)of 1st qualityconforming to IS: 15622 of approved make inandcolours laid on 20mm thick cement mortar 1:4 (1Cement :4Coarsesand) includinggrouting the jointswithwhite cement and matching pigments etc., complete. Sqm 767.0
11.5 62mmthickcement concrete flooring withconcrete hardener toppingunder layer50mmthickcementconcretegradeM-15(NominalMixwith20mmmaximumsize of stone aggregate) and top layer 12mm thickcement hardener consisting of mix 1:2 (1 cement hardenermix : 2graded stone aggregate 6mmnominal size)byvolume.Hardeningcompoundismixed@2litreper50kgofcementoraspermanufacturesspecifications. This includes cost of cement slurry, but excludingthecost of nosing of steps etc. complete.
21.1ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes,havingthermalstabilityforhot&coldwatersupplyincludingallCPVCplaneandbrassthreadedfittingi/cfixingthepipewithclampsat1.00mspacing.This includesjointingofpipes&fittingswithonestepCPVCsolventcementandtesting of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall.21.1.1 15 mm nominal outer dia .Pipes. Meter 109.00
21.1ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes,havingthermalstabilityforhot&coldwatersupplyincludingallCPVCplaneandbrassthreadedfittingi/cfixingthepipewithclampsat1.00mspacing.Thisincludesjointingofpipes&fittingswithonestepCPVCsolventcementandtesting of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall.21.1.3 25 mm nominal outer dia .Pipes. Meter 161.00
BRASS FITTINGS 21.12 Providing and fixing brass bib cock of approved quality : 21.12.1 15 mm nominal bore 0.40kg each 223.00
23.1 Providing and fixingwhite vitreous chinawater closet squatting pan (Indian type) P or S trap, complete including cutting and making good the walls and floors wherever required :23.1.1 Long pattern W.C. pan of size 580 mm Each 841.00 23.1.2 Orissa pattern W.C. pan of size 580x440 mm Each 1431.00
23.10 Providing and fixingwashbasinwithC.I. brackets, 15mmC.P. brasspillar taps,32mmC.P. brass waste of standard pattern, includingpaintingof fittingsandbrackets,cuttingandmakinggood the walls wherever require :23.10.5 White Vitreous ChinaAnglebackwashbasinsize600x480mmwithsingle 15 mm C.P. brass pillar tap.
4.1 Providingand laying inpositioncementconcreteof specifiedgradeexcludingthecostofcenteringandshutteringAllworkuptoplinthlevel.4.1.2CementconcretegradeM20(NominalMix)with20mmmaximumsize of stone aggregate Cum 5178.00
21.25 Providingandplacingonterraceatall floorpolyethylenewaterstoragetank ISI : 12701markedwith cover and suitable locking arrangement and makingnecessaryholes for inlet, outlet andoverflowpipesbut without fittings and the base support for tank. Ltr. 8.00
17.1 Providing and fixing aluminium work for doors, windows,ventilators andpartitionswithextrudedbuilt upstandardtubularsections/appropriateZsectionsand othersectionsofapprovedmakeconformingtoIS:733andIS:1285, fixedwithrawlplugsandscrewsor with fixing clips, or with expansionhold fasteners includingnecessary fillingupof gapsat junctions, at top, bottomandsideswithrequiredPVC/neoprene feltetc.Aluminiumsectionsshallbesmooth,rustfree,straight,mitredandjointedmechanicallywherever requiredincludingcleatangle,Aluminiumsnapbeadingfor glazing / paneling, C.P. brass / stainless steel screws, allcomplete as per architectural drawings and the directions ofEngineer-in-charge. (Glazing and paneling to be paid forseparately) :7.1.1 For fixed portion17.1.1.1Anodised aluminium(anodised transparent or dyed to requiredshade according to IS:1868,Minimum anodic coating of grade AC15)
17.2 Providing and fixing 12mm thick prelaminated particle board flatpressedthreelayerorgradedwoodparticleboardconformingto IS: 12823Grade l Type ll, inpanelling fixed inaluminumdoors, windowsshuttersandpartition frameswithC.P. brass / stainless steelscrewsetc. complete as per architectural drawings and directions of Engineer-in-charge 17.2.1 Pre-laminated particleboardwithdecorativelaminationononeside and balancing lamination on other side. Sqm 858.00 17.2.2 Pre-laminated particle boardwith decorative lamination on both sides. Sqm 931.00
17.3 Providing and fixing glazing in aluminium door, window, ventilatorshuttersandpartitionsetc.withEPDMRubberneoprene gasket etc. completeasper thearchitectural drawings and the directions ofengineer-in-charge(Costofaluminiumsnapbeading shall be paid in basic item): 17.3.1 With float glass panes of 4.0 mm thickness Sqm 648.00 17.3.2 With float glass panes of 5.50 mm thickness Sqm 806.00
11.35 Providingand layingvitrified floor tiles (without Solublesalt) or printed (withsolublesalt)Nanopolished (Glossy finish) indifferent sizeswithwater absorption less than 0.05%and conforming to IS : 15622 of approvedmake inall colours&shades, Ist quality/ premiumquality inflooring laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) includinggrouting the jointswithwhitecement andmatchingpigmentsetc. complete. Size 600x600mm as per manufacturer specification.
1.1 Point Wiring in surface rigid P.V.C. conduit system withFlushtypeAccessories.Pointwiringincludingmetallicswitchbox,sheet,switches,sockets, lamp holders/ceilingrosesetcwith1.5Sq.mm.PVC insulatedcable FRwith coppermulti strandconductor ISImarkedinSurfacerigidP.V.C.conduit (MMS)ISIMarkedofsuitablesizeand 1.5Sq.mm.PVCinsulatedcopper earth continuity conductor of green colour inside conduit including painting etc. as required as per specification for : 1.1.1 Light Point/Fan Points. a) Short point Each 330.00 b) Medium point Each 635.00 c) Long point Each 988.00
1.1 Point Wiring in surface rigid P.V.C. conduit system withFlushtypeAccessories.Pointwiringincludingmetallicswitchbox,sheet,switches,sockets, lamp holders/ceilingrosesetcwith1.5Sq.mm.PVC insulatedcable FRwith coppermulti strandconductor ISImarkedinSurfacerigidP.V.C.conduit (MMS)ISIMarkedofsuitablesizeand 1.5Sq.mm.PVCinsulatedcopper earth continuity conductor of green colour inside conduit including painting etc. as required as per specification for : 1.1.1 Light Point/Fan Points. a) Short point Each 330.00 b) Medium point Each 635.00 c) Long point Each 988.00
1.1 Point Wiring in surface rigid P.V.C. conduit system withFlushtypeAccessories.Pointwiringincludingmetallicswitchbox,sheet,switches,sockets, lamp holders/ceilingrosesetcwith1.5Sq.mm.PVC insulatedcable FRwith coppermulti strandconductor ISImarkedinSurfacerigidP.V.C.conduit (MMS)ISIMarkedofsuitablesizeand 1.5Sq.mm.PVCinsulatedcopper earth continuity conductor of green colour inside conduit including painting etc. as required as per specification for : 1.1.1 Light Point/Fan Points. a) Short point Each 330.00 b) Medium point Each 635.00 c) Long point Each 988.00
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_571692.pdf
techsummary_571692.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.35 MB
Document.pdf
Tender Documents • 3.26 MB
BOQ_571692.xls
BOQ • 0.26 MB
Drawing.pdf
Additional Documents • 0.56 MB
Estimete.pdf
Additional Documents • 8.06 MB
Download all tender documents and submit your bid