Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹24.4 L+₹77,585 (3.29%)Rejected-AOC | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹25.5 L+₹1.9 L (8.14%)Rejected-AOC | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹25.6 L+₹2.0 L (8.50%)Rejected-AOC 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L4 | Rejected-AOC Not Lowest | |
| 5 | L5₹25.8 L+₹2.2 L (9.53%)Rejected-AOC HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | L5 | Rejected-AOC Not Lowest |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
25 Jun 2020, 6:00 pmClosed
GE UTILITY SECUNDERABAD
GE UTILITY, MUDFORT, SECUNDERABAD-500003
REPAIR REPLACEMENT AND MAINTENANCE OF DAY TO DAY COMPLAINTS OF EXTERNAL ELECTRIFICATION SUPPLY SYSTEM AND CONNECTED ALLIED WORKS IN ZONE-I A AND ZONE-I B UNDER AGE EM NO-I OF GE U SECUNDERABAD
2020_MES_348455_1
GE(U)/SEC/TOKEN/11 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
As per NIT
7 documents required · 7 mandatory
₹500
GE UTILITY SECUNDERABAD
₹68,000
Yes
23 Jul 2020
30 May 2020
27 Jun 2020
30 May 2020
25 Jun 2020
13 Jun 2020
Amount
M&L for attending, repair and rectification of external electric supply complaints , under ground / over head system along with necessary T & P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:-
Replacement of LT blown out fuse as per existing capacity in any location of upto 200 Amps.
Replacement of wornout jumpers, jointing and tightening with new ACSR conductor. Note:- Single phase/two wire or 3 phase/4 wire system will be considered as one job for payment purpose.
Trimming/pruning and removing of tree branches or any other foreign objects from over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system. Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job. (iii) Quoted rate is deemed to inclusive of Replacement of Insulators, Joining the ACSR Conductor, Jumpering and stringing the ACSR conductor etc.
Dismantling of insulators any size and any type from existing HT line/LT line , removing materials taking to schedule of credit complete all as specified Note:- Insulators shall be measured and paid separately under respective items.
Disconnecting from over head conductor, cutting worn out portion of LT/HT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply. Notes:- (i) LT/HT Jointing kits, LT XLPE Cables of any size, Cable protection Pipe if required at site will be measured and paid separately. (ii) Quoted rate is deemed to be inclusive of cutting and removing the Pole coping and inserting the cable along with protection pipes.
All as per item Sl No1.05 above but from LT/HT switch gear/main switch board of any type and size including provision of suitable size of aluminum / copper cable lugs.
Dismantling of rusted/ broken over head conductor of any type and length as required at site including removing of fore in objects if any from the over head lines. Notes:- (i) ACSR conductor used for replacement will be measured and paid under respective items. (ii) quoted rate is deemed to be inclusive of trimming of tree branches up to 1.5 Mtr around the conductor.
Replacement of faulty LT switch gear of any type and size fixed in panel board pole mounted boxes on walls or any other indicated places including provision of lugs/thimbles of suitable sizes. Note: - Switch gears will be measured and paid separately under relevant items of this schedule.
Replacement of blown out DO fuse, 11 KV grade of any capacity. Notes: (i) Quoted rate is deemed to be inclusive of Fuse wire of required gauge and necessary T & P required at site. (ii) No additional payments will be admissible for replacement of fuse in same system with an hour. (iii) Set of 3 fuses will be considered as one job for payment purpose.
Fixing only Energy meter of any capacity and any type. Note:- Energy meters will be measured and paid under respective items.
Dismantling of cross arms of Ms channel of angle setion for issue of schedule of credit
Dismantling of steel poles/ concrete poles of an site an location for issue of schedule of credit
Notes for Item Nos 1.01 to 1.13:- (a) The contractor will be allotted complaints at MES complaint cell on daily basis on all working days and sufficient resources will be deployed by him/her for completion of day to day complaints within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consultation with Engr-in-Charge or JE E&M as detailed. (c) The contractor will make suitable arrangement for emergency complaints and will notify authorised rep/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare utilized as per inventoy format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No I store on daily basis.
Supply only the following materials as in repairs/replacements complete all as specified and directed.
Supply and stringing ACSR conductor of any size for over head line connections of squirrel/weasel/Mink as per site requirement including provision of aluminum biding wire complete .
Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade.
Shackle type insulator, porcelain vitreous, white / brown / green, 1100 Volts grade, 75 mm height & 90 mm dia including galvanised mild steel strap of 31 x 3 mm, 12 mm dia insulator bolt, washers & nuts.
Loop type insulator porcelain vitreous white, brown or green with overall dimensions of 90 x 140 mm, clearance of hole 25.5 mm.
MCCB 63 Amps, 3 pole, 415 Volts with rapturing capacity 16 KA, adjustable thermal and fixed magnetic settings.
MCCB 100 Amps, 3 pole, 415 Volts with rapturing capacity 16 KA, fixed magnetic and thermal settings.
MCCB 160 Amps, 3 pole, 415 Volts with rapturing capacity 25 KA fixed magnetic and thermal settings.
MCCB 200 Amps, 4 pole, 415 Volts with rapturing capacity 35 KA fixed magnetic and thermal settings.
MCCB 250 Amps, 4 pole, 415 Volts with rapturing capacity 35 KA fixed magnetic and thermal settings.
MCCB 400 Amps, 4 pole, 415 Volts with rapturing capacity 35 KA adjustable magnetic and thermal settings. Note for Item Sl No 2.05 to2.10 : Any modification/ alteration in existing panel which is required to fixing of MCCB is deemed to be included in unit rate
AC single phase static energy meter of accuracy class 1.0, 240 V, 50 Hz with backlit LCD display of rating 5-30 A (measures and displays KWH,V,I,KW,pf,last month history of KWH,MD in KW) with special features like TOD,temper logging,optical communication port display in absence of power. Make: L&T/HPL or equivalent
M&L for cradles, hexagonal/rectangular, fabricated with galvanised steel wire 4mm dia as in repairs complete all as specified and directed.
Supply, lay, commissioning and testing of cable jointing Kit for 1100 V grade cable for straight through heat shinkble joint with jointing material and accessories suitable for aluminum conductor cable of size upto 35 sqmm, 3.5 Core complete all as specified and directed.
All as per item No 04 above but suitable for aluminium conductor cable of size from 50 sqmm, 3.5 Core to 95 Sqmm, 3.5 Core
All as per item No 4 here-in-before but suitable for aluminium conductor cable of size from 120 sqmm, 3.5 Core to 185 Sqmm, 3.5 Core
Supply, lay, commissioning and testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area laid in trenches / duct or fixed to wall / passing through pipe on pole with suitable size cable glands, crimping type cable lugs for stranded aluminum conductor of following sizes complete all as specified and directed :-
2 core X 10 Sqmm
4 Core X 16 Sqmm
4 Core X 25 Sqmm
4 Core X 35 Sqmm
3.5 Core X 50 Sqmm
3.5 Core X 70 Sqmm
3.5 Core X 95 Sqmm
3.5 Core X 120 Sqmm
3.5 Core X 185 Sqmm
3.5 Core X 240 Sqmm
Note for item Nos. 7.01 to 7.10 :Excavation, earth work, sand cushioning and cable protection items etc shall be measured and paid under respective items of Schedule 'A'.
Labour only for releasing the binding of ACSR conductor of LT / HT over head line from insulator, removing the jumper, connector, service wire, UG cable and restringing the existing ACSR conductor of any size, length, span upto desired sag and fixing the existing ACSR conductor on insulators by proper binding, jumper connection etc complete all as specified and directed. Notes:- (i) Single run of conductor will be measured as one unit which is deemed to be included in the quoted unit rate. (ii) Extra aluminum conductor required for jumpers and binding purpose is deemed to be included in the quoted unit rate.
M & L for testing earthing of installations, buildings, equipment etc and treating of earthings by pouring salt water and submit results sheet to AGE E/M No-I complete all as specified and directed. Note: Contractor has to arrange necessary tools required for the job
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in hard / dense soil complete all as specified and directed.
All as per item No 10.00 here in before but depth above 1.5 m & below 3 m
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down shall be measured for payment.
Supply and Lay reinforced precast concrete cable cover LV, Type I,flat, size 230x150x40 mm complete all as specified and directed.
M&L for PCC 1:3:6 type C1 using 20mm graded aggregate as in coping/pedestals of poles including necessary form work complete and applying two coats of white wash to exposed surface of coping/platform complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded aggregate as in foundation, filling and mass concrete for pole / stay / post etc complete all as specified and directed.
M&L for stay assembly with all accessories as shown in Electrical Plate No 1 of SSR Part I (2009) with 16 mm dia stay rod and including 7/2.24 mm size stay strand and stay clamps including dismantling old unserviceable stay assembly complete all as specified and directed. Note : Loop type insulator, excavation, earth work and concrete shall be measured and paid separately under relevant items of this schedule.
M/L cross arms, bracing supports clamps and back plates fabricated from structural steel section incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as directed including applying two coat of quality aluminum paint over one coat of red oxide primer and fixed over RCC Pole/ steel poles of any height complete all as specified and directed.
M & L for replacement of broken earth pit made out of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, 20 mm thick and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia TMT bars @ 100 mm center to centre both ways with hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site complete all as specified and directed.
M & L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 2 coats of aluminium paint over a coat of red oxide primer including throughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) from ground level, complete all as specified and directed.
M & L for Painting the existing LT PCC poles with applying two coat of cement based paint over one coat of primer including painting of cross arms, clamps, etc with two coats of aluminum paint and providing alternative band of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 meter height , writing of pole numbers in yellow circle15 cm with black paint on poles complete all as specified and directed.
Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminum paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- Item of earthing includes cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade.
M&L earthing complete with copper earth plate electrode 60cm x 60cm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of plate not less than 1.5m below ground level, connecting to the copper earth strip 20 x 3mm dia, by means of nuts, bolts, check nuts and washer etc of copper and earth strip protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- The cost of 7.5m long copper earth strip of 20 x 3mm size and protection pipe of 40mm bore GI medium grade is deemed to be included in quoted unit rate.
S&F in repairs post of top lantern pure polyester UV resistant power coated die cast aluminum housing with PMMA clear diffuser for uniform illumination IP66 LED as light source of capacity 20 watts with suitable drivers, 10 KVA in built surge protection etc and connecting with 2.5 sqmm copper conductor PVC insulated three core weather proof cable etc, including taking down old unserviceable gate light fitting of any type and capacity complete all as specified and directed. Make:- Wipro Cat No. LP07-251-XXX-57-CL or Equivalent in Wipro/ philips .
S&F in repairs surge protection of 10 KV suitable upto 100W LED light fittings suitable to operate on input voltage 440 AC, 50 Hz, complete all as specified and directed. Make: C&S / Havells/ Cromption cat part No 5RPSQ10KV/5KV-440
Supply & lay heavy duty PVC insulated multi stranded Aluminum conductor twin core of size 4.0 Sqmm, 230 volts, 50 HZ complete all as specified and directed.
Supply & lay heavy duty PVC insulated multi stranded Aluminum conductor twin core of size 6.0 Sqmm, 230 volts, 50 HZ complete all as specified and directed.
Supply & lay heavy duty PVC insulated multi stranded Aluminum conductor twin core of size 10.0 Sqmm, 230 volts, 50 HZ complete all as specified and directed.
Supply & lay Galvanised Iron tubing 50mm bore, light grade in protection of cable at road crossing/hard standing/pole protection fixed with MS clamps of size 40 X 4 mm, nut bolts and washer as per site requirement including taking down old unserviceable pipes complete all as specified and directed.
All as per item No 31 above but GI tubing 80 mm bore. Make for item No 31 & 32 : TATA/Jindal/Bansal.
M&L cutting of road/hard standing upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable/protection pipe line making good the disturbed portion so as to match existing finishing with PCC 1:2:4 type B1/cement mortar in CM (1:2) complete all as specified and directed
S&F On- load changeover switch in sheet metal enclosure with front handle operating system, powder coated, factory made of capacity 100 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed. Make:- Standard Cat No ISCFFE0100 or equivalent make in Havells/Legrand/IndoAsian.
S&F Off- load changeover switch in sheet metal enclosure with front handle operating system, powder coated, factory made of capacity 63 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed. Make:- Indoasian Cat No OFFP0063 or equivalent make in Havells/Legrand/Standard.
S&F Off- load changeover switch in sheet metal enclosure with front handle operating system, powder coated, factory made of capacity 100 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed. Make:- Indoasian Cat No OFFP0100 or equivalent make in Havells/Legrand/Standard.
S&F Off- load changeover switch in sheet metal enclosure with front handle operating system, powder coated, factory made of capacity 200 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed. Make:- Indoasian Cat No OFFP0200 or equivalent make in Havells/Legrand/Standard.
S&F rewirable switch unit in sheet metal enlosure with powder coated, factory made of capacity 100 Amps, 4 pole with fixing arrangement on site including removing the existing unserviceable one complete all as specified and direted. Make:- Havells Cat No IHBRTE4100 or equivalent make in Havells/Legrand/Strandard .
S&F time light street light control distribution board, outdoor, pole mounted, made out of 3mm thick MS sheet duly powder coated front openable, IP 65 protection, with 2 Nos FI clamps of size 30mm x 4mm complete all as specified and directed including provision of the following accessories:- (a) Digital time switch din type, astronomical programmable every 1 min, backup 6 years, 28 memory locations, current capacity 16 Amps, with 1 changeover (1 CO), total 28 programmers - 01 No. Make:- Indo Asian Cat No TLO32ASO or equivalent make in L&T/Legrand. (b) Power contactor heavy duty 40 Amps TP - 01 No. Make: L&T/C&S/Legrand/IndoAsian. (c) MCB TP,440 Volt, 40 Amps - 01 No. (d) Connector terminal 40 Amps - 06 Nos. (e) Auto manual switch - 01 No. Make : Standard/L&T/IndoAsian.
S&F Weather proof outdoor bus bar chamber, made out of 3 mm thick MS sheet duly powder quoted comprising 4 Nos aluminium strips each of 200Amps, 60cm long duly insulated mounted on insulators including MCCB 200 Amp with 4 No’s mounting legs made out of 25mm x 25mm x 6mm angle iron grouted in PCC block of size 30cm x 30cm x 90cm (30cm depth below ground level and 60cm above ground level) in cement concrete 1:3:6, type C-2 (using 40mm grade crushed stone aggregate), and connections with suitable size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work, returning filling and removal of surplus soils, including taking out old unserviceable bus bar chamber complete all as specified and directed.
Supply & Fill distilled water in batteries of solar street lights of any capacity and any height all as specified and directed by Engr in charge.
S& F in replacement of old unserviceable lugs after cutting the worn out /faulty cable end from LT pillar/panel box including necessary earth work for taking out the cable from loop line, returning, filling in and making cable lead by providing aluminum lugs including crimping with crimping tools in the existing LT cable 3.5 core upto 25 Sqmm including necessary connection complete all as specified and directed.
All as per item No 42 above but aluminium lugs of size 35 Sq mm.
All as per item No 42 here-in-before but aluminium lugs of size 50 Sq mm.
All as per item No 42 here-in-before but aluminium lugs of size 70 Sq mm.
All as per item No 42 here-in-before but aluminium lugs of size 95 Sq mm.
All as per item No 42 here-in-before but aluminium lugs of size 120 Sq mm.
All as per item No 42 here-in-before but aluminium lugs of size 150 Sq mm.
All as per item No 42 here-in-before but aluminium lugs of size 185 Sq mm.
S&F conneting and testing MCB isolator three pole and neutral (TPN) 440 olts of capaciyt 63 A 16 KA 50 "c" curve complete
S&F connecting and testing MCB isolator three pole and neutral (TPN) 440 volts of capacity 100 A 16 KA 50 "c" curve complete
Brite electricals
The Deccan Engineering and Refrigeration Company
STANDARD AGENCIES
omsai thermax engineers
Srinivasa Consructions
Sri Balaji Enterprises
Mavee Syndicate
POWER CONSTRUCTION COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .