Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC | ₹27.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹27.7 LRejected-Finance | ₹27.7 L | L2 | Rejected-Finance L2 |
| 3 | L3₹28.5 LRejected-Finance | ₹28.5 L | L3 | Rejected-Finance L3 |
Tender Value
₹37.0 L
EMD Value
₹74,000
Closing Date
24 Nov 2025, 5:00 pmClosed
OSD(M)
YAMUNA EXPRESSWAY INDUSTRIAL DEVELOPMENT AUTHORITY
Maintenance of Street Light on 30mtr wide road ch.6.95km to front ATS Township (Year-2025-2026) yea (WC-E,M-03)
2025_YEIDA_1090302_11
YEA/OSD(M)/2025/334 DT-06/11/2025
Open Tender
Electrical Works
365 days
YAMUNA EXPRESSWAY INDUSTRIAL DEVELOPMENT AUTHORITY
Please refer Tender documents.
5 documents required · 5 mandatory
₹960
₹74,000
10 Feb 2026
14 Nov 2025
26 Nov 2025
14 Nov 2025
24 Nov 2025
14 Nov 2025
Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1.5 Mtr length each ) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.as per the directions of the Engineer-in-charge. make Bajaj, Philips, Paruthi, Surya, BP Projects) PWD-2018/PS No-646
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection n complete in all respect as per direction of the Engineer Incharge. PWD-2018/PS No-1423, CAT- AAA
Supply & laying of Aluminium conductor, XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (CCI (Bombay/Nashik), Fort Gloster (Calcutta / Baripara), Asian (Thane / Silvasha), Universal (Satna), Nicco (Calcutta), ICL (Rajpura), Diamond, Havells , KEI make & for small works upto value of cable for Rs. 25.0 lacs Kalinga, Suraj, Delton, Grandley & Polycab make can be used old Cable Amount (Rate of and cable reduced by 10% for old Cable scrap Cable) UPPWD-2018 PS No-501 3.5C x 25 Sqmm.
Supply & laying of Aluminium conductor, XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (CCI (Bombay/Nashik), Fort Gloster (Calcutta / Baripara), Asian (Thane / Silvasha), Universal (Satna), Nicco (Calcutta), ICL (Rajpura), Diamond, Havells , KEI make & for small works upto value of cable for Rs. 25.0 lacs Kalinga, Suraj, Delton, Grandley & Polycab make can be used old Cable Amount (Rate of and cable reduced by 10% for old Cable scrap Cable) UPPWD-2018 PS No-501 3.5C x 70 Sqmm.
S/F of copper conductor XLPE insulated, un-armoured cable 3C x 1.5 Sqmm Complete in all respects as per the directions of the Engineer-in-charge. YEIDA SOR-01
Supply & fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, making connections etc. complete in all respects as per direction of the Engineer-in-charge. UPPWD -2018 PS-504 (a) 25 sqmm.
Supply, Delivery, Installation, Testing & Commissioning of Straight through cable jointing kit for L.T. PVC armoured cable jointing. Complete in all respects as per direction of the Engineer-in-charge.. (make Raychem, CCI, Forntec) YEIDA-7 3½CX25 Sq.mm.
Supply, Delivery, Installation, Testing & Commissioning of Straight through cable jointing kit for L.T. PVC armoured cable jointing. Complete in all respects as per direction of the Engineer-in-charge.. (make Raychem, CCI, Forntec) YEIDA-7 3½CX70 Sq.mm.
Digging of Cable & relaid in same trench complete in all respect, as directed by Engineer in charge Analysis of Rate
Supply & Fixing of PVC Insulation Tape 19/20mm 8Mtr Long.(Steelgrip) Complete in all respects as per direction of the Engineer-in-charge. YEIDA-44
S/L of 90mm dia. DWC pipe for drawing of power cable across the road by drilling of 120mm dia. at 1mtr. below the road level thereby doing the work of providing DWC pipe by manual Trenchless method. YEIDA-12
Construction of Pole Plinth complete in all respect, as directed by Engineer in charge Analysis of Rate
S&F of 125 Amp, 4Pole MCCB (16KA) Thermal Magnetic Relase complete in all respect, as directed by Engineer in charge.UPPWD-2018 PS No-1021 (A)
S&F of 100 Amp, 4Pole Isolator complete in all respect, as directed by Engineer in charge. UPPWD-2018 PS No-1007 ( C)
S/F of 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 Mtr. below ground level complete with 20 mm dia G.I. pipe & funnel for watering & one earthing lead of one no. 8 to SWG GI wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of GI pipe and GI wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of char-coal/coke & salt atleast 150 mm thick all-around etc. as per direction of Engineer-in-charge complete in all respects. UPPWD-2018 PS No-702
Supply and laying of 25mmx3mm G.I. strip from earth electrode directly in the ground as required complete in all respect.UPPWD-2018 PS No-710
Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect as per the directions of the Engineer-in-charge. (a) 40 A TPN PWD-2018/PS No-807
Repair of Transformer Incl. Changing of HV & LV Coil, Bushing, Gasket & Fresh Transformer oil without returnning of old & unsearciable material. as directed by Engineer in charge 63/100KVA Transformer
Dis./Re-errection of 63/100 KVA Al./copper wound outdoor type Transformer.per ISS including fess as directed by Engineer in charge
Hire & running charge of Hydraulic ladder with Driver including cost of service charge of operating staff & Diesel/Petrol complete in all respect, as directed by Engineer in charge Analysis of Rate
Numbering of poles with combination of yellow and black colour paint etc. complete in all respects as per direction of E/I at site. Analysis of Rates
Electrician/Operator complete in all respect, as directed by Engineer in charge Analysis of Rate
Electrician/Operator complete in all respect, as directed by Engineer in charge Analysis of Rate
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.27 MB
11.pdf
Tender Documents • 1.50 MB
BOQ_2002660.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid