Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.9 LAccepted-AOC | ₹32.9 L Quoted ₹34.1 L | L1 | Accepted-AOC Awarded |
| 2 | L2₹35.0 L+₹91,085.80 (2.67%)Rejected-Finance | ₹35.0 L+₹91,085.80 (2.67%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹35.3 L+₹1.2 L (3.42%)Rejected-Finance 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | ₹35.3 L+₹1.2 L (3.42%) | L3 | Rejected-Finance Rejected |
| 4 | L4₹38.6 L+₹4.5 L (13.2%)Rejected-Finance | ₹38.6 L+₹4.5 L (13.2%) | L4 | Rejected-Finance Rejected |
Tender Value
₹41.4 L
EMD Value
₹82,700
Closing Date
21 Sept 2022, 6:00 pmClosed
GE AF Subroto Park
GE AF Subroto Park c o 56 APO
ADDN/ ALTN TO BOUNDARY WALL OF AFCME COMPOUND WALL OF CAMERO SNCOs MESS AND ADDN/ ALTN TO ANNEXE II BLDG IRLA SETS OFFICE OF AFCAO AT CAMERO COMPLEX
2022_MES_547482_1
GE/SP/ TOKEN-24/2022-23
Open Tender
Civil Works
Item Rate
180 days
Subroto Park Delhi Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE AF Subroto Park
₹82,700
Yes
13 Oct 2022
25 Aug 2022
28 Sept 2022
25 Aug 2022
21 Sept 2022
9 Sept 2022
Amount
Demolition of PCC (un-reinforced) in ground floors & pavings n.exc 15 CM thickness below or above ground level, complete all as specified and directed by Engr-in-Charge.
Demolition of brick or stone boulder masnory, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facing, dressed stonework and percast concrete articles complete all as specified and directed by Engr-in-Charge.
M&L for Brick work with subclass B bricks, staright or curved on plan exc 6.00 mtr mean redius, biult in 1:6 cement mortar complete all as specified and directed by Engr-in-Charge. .
M&L for 15 mm thick cement plaster in cement mortar 1:4 on concrete or brick surface and finished even and smooth w/o using extra cement complete all as directed and specified.
Excavation in trenches, not exceeding 1.5 m wide and not exc 1.5 m in depth for foundation, for pole, laying of cable, etc and not exceeding 10 sqm on plan and getting out in hard/ dense soil, complete all as specified. and directed by Engr-in-Charge
Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25 Cm thick, , complete all as specified. and directed by Engr-in-Charge.
Removing surplus excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc. 1.5 m above the starting point, complete all as specified and directed by Engr-in-Charge.
M & L for cement concrete type D-2 1:4:8 (using 40mm aggregate) as in foundations, filling and mass concrete complete all as specified and directed by Engr-in-Charge.
M&L for Mild steel bars TMT 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
M&L for Mild steel bars TMT 8 mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
M&L for RCC design mix M-25 ( using 20 mm graded stone aggregate) as in foundation, raft footing, foundation beams, plinth beam, base for columns etc, basement slab under reamed piles and mass concrete complete all as specified and directed by Engr-in-Charge.
M&L for RCC design mix M -25 ( using 20 mm graded stone aggregate) as in slabs supported on walls,, beams and columns in floors, roofs, landing balconey, canopies, deck slab and in shelves complete all as specified and as directed by Engineer in charge
M&L for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits if any of foundation and plinth beams and simillar work vertical or laterels complete all as speciied and directed by Engineer in charge
M&L for form work to sides of pillars, posts complete all as speciied and directed by Engineer in charge
M&L for preparation of new plastered surfaces of walls, and applying two coats of cement based paint over a coat of primer complete all as specified and directed by Engr-in-Charge.
M&L for Cement Concrete 1:2:4 Type B-0 (using 12.5 mm graded stone aggregate) as in roof kerb , coping or mud stops rounded of chamfered on edge complete all as specified and directed by Engineer-in-Charge.
M&L for coloured granite slab, 18-20 mm thick, as in floor or skirting and similar work etc., bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including Chamfering\Rounding the edges complete all as specified and as directed (colour & design approved by GE). Over 15mm thick screed bed in CM 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for Chequered cement concrete coloured tiles (300 X300) 20-25mm thick confirming to IS -1237 (rubber moulded) in floor setc, set, jointed & pointed with cement slurry 15mm thick bedding layer of cement sand mortar (1:6) including 100mm thik cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base for floors finishes included dismantling complete all as specified and directed by Engr In Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
M&L for vitrified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with neat cement slurry over 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor complete all as specified and as directed by Engr-In-Charge.
Ditto as above item No-36 but as on vertical surface of wall such as skirting/dado incl 10mm thick cement plaster (1:4) as in backing coat of tiles complete all as specified and directed.
S&F non skid coloured ceramic tiles area of each tiles exceeding 0.11sqm but not exceeding 0.18 Sqm and 7mm thick as in floor set & jointed in neat cement slurry & pointed in coloured cement to match over 15mm thick screed in cement mortar 1:4 complete all as specified and directed by Engr-in-charge.
Material and labour for glazed ceramic coloured tiles in vertical surface 300x450X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick screed in cement 1 :4 and pointed in white or coloured cement to match the shade complete all as specified and directed.
Dismantling of structural steel work including doors, gates, grills but excluding framed trusses complete all as specified and directed.
S&F frame of stainless steel railing of any size and shape with stainless steel tubular/square/rectangular hollow pipe including welding and necessary drilling, bolting and rieveting and fixing at site etc all as specified and directed by Engineer-in-Charge.
Material and labour for false ceilings using GI snap grid system with roll-formed out of hot dip galvanised steel caping (powder coated) main runner 38 x 24 mm , cross Tee 29 x 24 mm and wall angle 24 x 24 mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceiling board , pre painted Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions size 595 x 595mmx 4mm thick any texture (Lake and Hill, oceaniccascade or Electra) as approved by GE all as per , Everest Ceiling grid system 'Regular T-2430' or its equivalent make of "'Ramco, Charminar/Armstrong'' at any height including dismantling complete all as specified and as directed by Engr-In-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.50 Sqm each complete all as specified and as directed
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5Sqm but not exc 4.00 Sqm each complete all as specified and as directed
S&F aluminium powder coated any colour (minimum thickness of powder coating 50 micron) for doors, windows, partician, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engr-in-charge..
S&F aluminium powder coated any colour(minimum thickness of powder coating 50 micron) as in window and ventilator shutters, sliding type three track, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber packing, anodised aluminum snap beading screws etc. complete all as specified and as directed by Engr-In-Charge.
S&F for powder coated aluminium doors shutters,( thickness of powder coating not less than 50 micron) aluminium section weighing 0.55 kg/m incl necessary joining cleats, glazing clips, rubber neoprene packing , handels 2 Nos in each door , hinges, anodised aluminium snap beading screws etc. complete all specified and directed by engr-In-Charge.
S&F 12mm thick particle board prelaminated on both sides as in panel of door shutters partition wall, work stations including beading etc complete all as specified and directed by Engr-in-Charge.
S&F Aluminium(extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as directed and specified.
S&F brass body Mortice lock, vertical type,size 100 mm 4 lever, incl escutcheon plate and two No keys fixed complete all as specified and directed by Engr-in-Charge.
S&F in repair vertical venetian blinds made out of nylon cloth of any colour as approved including hanging arrangement rollers etc complete as specified and directed by Engineer in charge.
S&F in repairs for double action floor spring hydraulically regulated mode lap of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed to shutter complete all as specified and directed by Engr-in-Charge.
S & F in repair 150mm long floor door stopper of brass body and tongue with hard drawn steel spring complete all as specified.
S&F in repairs Vitreous China wash basin white ovel shape counter top of size 630x450mm including all fitting like pillar tab, pvc connection complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs 32mm dia Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap complete all as specified.
S & F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal aginst wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screw, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, gratting and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe.
Dismantling water tanks exc 500 but not exc 1000 ltrs capacity and removing to store complete all as specified and directed by Engr In Charge.
S & F rotational moulded polyethylene water tank 1000 litre capacity tripple layer (white colour) (cylindrical vertical with closed top) hoisted and fixed as specified in SSR Part-I complete all as directed at site.
S&F 20 mm bore Gun Metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed
S&F 20 mm Ball brass valves high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed
S & F in repairs CP waste coupling 32mm size half threaded with 130mm height completed as of Make-ALD-709 of Jaquar or its equivalent GEM/ Marc as approved make complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs 15 mm bore angle valve chromium plated with wall flange and fancy type with high pressure screwed down with CP flange. Make- ORM- 10053 of Jaquar or its equivalent Parco/Marc complete all as specified and as directed by Engineer-in-Charge.
Supplying and fixing in repair for vitreous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, jet spray, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, excluding fixing bolts, flushing cistern and flush pipe) complete all as specified.
S & F in repairs PVC valveless, syphonic action type, flushing cistern, low level, white with inlet ball valve foat and handle including brackets 10 litres complete all as specified and directed by Engr-in-charge.
S & F in repairs bib tap cast copper alloy fancy type chromium plated with crutch or butterfly handle screwed down for 15mm bore pipe complete.make -CON -037KKN of Jaquar or equivalent in MARC/GEM/PARKO
S & F in repairs CP Soap dish of Make-AQN-7731 of Jaquar MARC/GEM/PARKO complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs 15mm bore two way angle valve chromium plated with wall flange and fancy type high pressure screwed down with CP flange complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs PTMT grating round of 100mm dia (Miniumum wt 50gms) complete all as specified and as directed by Engineer-in-Charge.
S&F in reapirs PTMT grating with waste hole (Minium wt 100 gms) complete all as specified and as directed by Engineer-in-Charge.
S&F in repiar CP connection 15mm size for Hot & Cold water with CP nuts of length 450mm long all as specified
S&F 20mm bore Tubes, 'medium grade' galvanised, with all fitting and fixed including taking down complete to walls and ceilings or laid in floors complete all as spd.
All as per sr item No 73 above but 15mm bore .
Taking down cement or cement lime plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc
M&L for rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces of walls, finished even and smooth ( without using extra cement) complete all as specified
M&L for rendering CM (1:3) 5 mm thick on concrete surfaces of ceiling, even and smooth without using extra cement.
Supply only liquid water proofing compound only
M&L for preparation of new plastered surfaces of walls, and applying two coats of distemper oil emulsion over a coat of primer incl 3mm thick elastomeric wall care putty on walls complete all as spd.
M&L for preparation on new or previously untreated wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over putty complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered or unplastered surface and applying three coats of white wash on ceiling complete all as spd .
M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper, including repairing of pot holes and cracks with putty,complete all as specified and directed by Engr-in-Charge.
Material & Labour for prepration of old plastered or unplastered surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces over putty complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint, complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete in sunken portion in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-Charge.
M&L for providing and making fillet of 75mmx75mm in size with cement concrete in 1:2:4 in sunken portion, complete all as specified .
Refilling Lime concrete with brick aggregate (Course) in lime mortar1:3, 300mm thick in the sunken with the help of proper tools & equipments & plants complete all as specified and as directed by Engineer-in-Charge.
Providing and making cement concrete in 40mm thickness in 1:2:4 type B0 (12.5mm graded aggregate) mixing Dr Fixit Pidiproof LW+. Complete in sunken upto the below level of tiling complete all as specified and as directed by Engineer-in-Charge.
M & L for 75 mm thick cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm wide joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed.
M&L for brick work with subclass B bricks, staright or curved on plan exc 6.00 mtr mean redius, built in 1:4 cement mortar complete all as specified and as directed by Engineer-in-Charge.
M&L for brick work with subclass B bricks, staright or curved on plan on plan to any redius in half brick thickness wall, built in 1:4 cement mortar complete all as specified and as directed by Engineer-in-Charge.
S&F 110 mm dia bore PVC (SWR) bends, including removing for concrete and refixing with 1:2:4, type B1 (20 mm graded aggregate) or in 1:3 cement mortar complete all as specified and as directed by Engineer-in-Charge.
S&F PVC (SWR) 110 mm dia bore pipe single socketed, in any length with rubber ring joints fixed to walls, including necessary PVC clamps for fixing of pipes complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC concealed conduit, medium grade, ISI marked not less than 20mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal modular box powder coated of suitable size for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified. For one light/ fan/ bell point controlled by one SP switch Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
All as per item No-20 above but for one 3 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size.
All as per item No-20 above but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size.
All as per item No 20 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to box of required size all as specified and directed by Engineer-in-Charge.
S&F switch piano 5 amps flush type single pole one way suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet flush type 5 pin 6 amps suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F switch piano 16 amps flush type single pole one way suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet 2 in 1, 5 pin 16 amps flush type suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of powder coated aluminium dia castand spun aluminium with clear/opal diffuser suitable for landscape lighting post top fitting,energy saving, environment friendly, long life aesthetically designed with good indriect symmetrical light distribution, die - cast aluminium landscape luminiaire with 40 watt LED 5700 K all as specified and directed by engineer - in- charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
S&F in replacement MCB SP 6 to 40 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
S&F in replacement MCB SPN 40 Amps 10 KA, 240 volt 50 HZ 'C' Series all as specified and directed by engineer-in-charge.
M&L for Sand cushioning of cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable complete all as directed by engineer-in-charge.
Supply and laying well burnt sub class ‘B’ bricks old size as mechanical protection to under ground cables laying across the cable copmlete all as directed by engineer-in-charge.
Supply and fixing ceiling roses, surface bakelite 65x50mm ,3 terminals 3 phase, PVC/Polycarbonate, isolated body all as specified and directed at site.
M & L for submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified Note:- 2 Runs of 4.0 Sqmm single core and one run of 4.0 sqmm single core cable as earth wire including PVC conduit shall be measured as one unit length.
M & L for submain wiring with two run of single core 6.0 sqmm PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified Note:- 2 Runs of 6.0 Sqmm single core and one run of 6.0 sqmm single core cable as earth wire including PVC conduit shall be measured as one unit length.
Supply and fixing of factory fabricated sheet steel enclosure, phosphatised, power painted, single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 amp, 240 volts, 10KA complete all as specified and directed by engineer-in-charge.
S&F of LED ceiling light 34 watt 2x2 recess LED, 6000 K luminaire having glare free symmetrical illumination Complete all as specified and directed by Engineer-in-Charge.
S&F wall mounting fan 400 mm sweep 230 Volt, 2200 RPM including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 8 way 415 volts 250 Amps rated bus bar and stove enamels dust and vermin proof suitable for FP 'A' frame MCCB of 250 Amps =01 No and MCB for outgoing complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
S & F of MCCB 4 pole 415 V, adjustable type 250 amps with breaking capacity of 16 KA all as specified and directed by Eng in charge.
Supplying, laying, jointing and testing XLPE insulated heavy duty multi stranded armoured and PVC sheathed LT UG cable 1100 volts grade with aluminium conductor conforming to IS- 1554 laid in trenches/fixed on wall/ducts/along poles/ through pipes of size 70 sq mm, 3.5 core complete all as specified and directed by Engr-in-charge.
Material and labour for cutting of road/ hard standing up to a size not exceeding 20cm width and not exceeding 60cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 and block top with black bituminous upto existing surface level complete all as specified and as directed by Engineer-in-charge.
Supply and laying GI pipe light grade galvanized with all fittings laid in trenches or fix on wall for cable protection of 80 mm bore copmlete all as directed by engineer-in-charge.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .