Amount
Supply of Material:
400 KVA, 11/0.433KV. 3-Phase Distribution Transformers with bimetallic Terminal Connector Energy Level-2, (Aluminium wound upto 200KVA, Copper Wound for 250KVA or her KVA ratings), and with LV Cable Box having detachable Aluminium Gland Plate.
250 KVA, 11/0.433KV. 3-Phase Distribution Transformers with bimetallic Terminal Connector Energy Level-2, (Aluminium wound upto 200KVA, Copper Wound for 250KVA or her KVA ratings), and with LV Cable Box having detachable Aluminium Gland Plate.
11KV GO, AB Switch 3-Phase, 3-Pole, 200Amp, Vertical Type
11KV Horn Gap, Fuse Set 3-Phase 200A
185sqmm(2Ckt) Cable, 1.1KV Grade, PVC Insulated Stranded Conductors FRLS Type for 25/63/100KVA & 250KVA DTs
Supply of 9 Mtr. Long Pole, ST-410 SP33
Supply of 33KV Polymeric Composite Disc Insulator 36KN, min failing load 70KN, Lightining Impulse 170KV Positive and 180KV Negative, Creepage distance 900mm
Supply of GI Channel/Angle/Flat of sizes including clamps
Supply of Galvanized nuts and bolts
Supply of Earthing of Substation Excavation of Earth Pit of dia 650 mm & depth 3000mm, installation of Earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as per IS 1239. GI Strip for neutral earthing of size 25mmx3mm for connection of Transformer body, G.O set & lighting arrestor as per IS 2629/85, GI nuts & Bolts, reffilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover.
33KV Polymer Composite Pin Insulator 36KV, 10KN, lighting Impluse 170KV positive and 180KV negative, creepage distance 900mm
LT Distribution Box for 400KVA DTR with TPN MCCB short ckt rating 16KA for incommer 630Amp (400KVA) and suitable MCCBs for outgoing circuits with terminal extensions (Single Pole 3 Phase 300 Amp three Outgoing Circuits)
LT Distribution Box for 400KVA DTR with TPN MCCB short ckt rating 16KA for incommer 340Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions (Single Pole 3 Phase 200 Amp three Outgoing Circuits)
Galvanised Stay Set with 50x8mm stay clamp, guy Insulator(2Nos), anchor Plate(200x200x6mm), nuts-bolts, 2 Nos turn-Buckles, 1.8m long, 16mm diameter solid GS stayrods & 7/3.15 mm dia GI stranded wire complete
Wedge Connector /PG Clamps
Danger Plate with Clamps
GI Barbed Wire for Anti Climbing
Cement Bottoming 1:2:4 mix as per REC standards .5cum/pole
Painting of poles Red Oxide
Painting of poles Aluminium Paint
Sundry items like Aluminium lugs, Jumper, binding Tape
Transformer Bed
Transformer fencing
(Labour part)
400 KVA, 11/0.433KV. 3-Phase Distribution Transformers with bimetallic Terminal Connector Energy Level-2, (Aluminium wound upto 200KVA, Copper Wound for 250KVA or her KVA ratings), and with LV Cable Box having detachable Aluminium Gland Plate.
250 KVA, 11/0.433KV. 3-Phase Distribution Transformers with bimetallic Terminal Connector Energy Level-2, (Aluminium wound upto 200KVA, Copper Wound for 250KVA or her KVA ratings), and with LV Cable Box having detachable Aluminium Gland Plate.
11KV GO, AB Switch 3-Phase, 3-Pole, 200Amp, Vertical Type
11KV Horn Gap, Fuse Set 3-Phase 200A
185sqmm(2Ckt) Cable, 1.1KV Grade, PVC Insulated Stranded Conductors FRLS Type for 25/63/100KVA & 250KVA DTs
Supply of 9 Mtr. Long Pole, ST-410 SP33
Supply of 33KV Polymeric Composite Disc Insulator 36KN, min failing load 70KN, Lightining Impulse 170KV Positive and 180KV Negative, Creepage distance 900mm
Supply of GI Channel/Angle/Flat of sizes including clamps
Supply of Galvanized nuts and bolts
Supply of Earthing of Substation Excavation of Earth Pit of dia 650 mm & depth 3000mm, installation of Earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as per IS 1239. GI Strip for neutral earthing of size 25mmx3mm for connection of Transformer body, G.O set & lighting arrestor as per IS 2629/85, GI nuts & Bolts, reffilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover.
33KV Polymer Composite Pin Insulator 36KV, 10KN, lighting Impluse 170KV positive and 180KV negative, creepage distance 900mm
LT Distribution Box for 400KVA DTR with TPN MCCB short ckt rating 16KA for incommer 630Amp (400KVA) and suitable MCCBs for outgoing circuits with terminal extensions (Single Pole 3 Phase 300 Amp three Outgoing Circuits)
LT Distribution Box for 250KVA DTR with TPN MCCB short ckt rating 16KA for incommer 340Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions (Single Pole 3 Phase 200 Amp three Outgoing Circuits)
Galvanised Stay Set with 50x8mm stay clamp, guy Insulator(2Nos), anchor Plate(200x200x6mm), nuts-bolts, 2 Nos turn-Buckles, 1.8m long, 16mm diameter solid GS stayrods & 7/3.15 mm dia GI stranded wire complete
Wedge Connector /PG Clamps
Danger Plate with Clamps
GI Barbed Wire for Anti Climbing
Cement Bottoming 1:2:4 mix as per REC standards .5cum/pole
Painting of poles Red Oxide
Painting of poles Aluminium Paint
Sundry items like Aluminium lugs, Jumper, binding Tape
Transformer Bed
Transformer fencing
Dismentalling (Labour Part):
Dismentalling of existing DT structure wherever required and un-mounting of old DTs along with allied materials back to PDD Store Choglamsar
M/S OTZER ENTERPRISE (BID ID -139719)
M/S DORJAI ELECTRICALS (BID ID -139714)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .