Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-Finance 26 8 2 PUNE MUMBAI ROAD OPP B U BHANDARI SHOWROOM EKTA PARK SOCIETY WAKDEWADI PUNE 411 003 | PUNE | MAHARASHTRA | 411003 | L1 | Accepted-Finance Being Lowest (L1) | |
| 2 | L2₹12.7 L+₹32,384 (2.63%)Rejected-Finance FLAT NO 107 C WING SKYWAYS SERENO LOHEGAON PUNE 411 047 | PUNE | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹19.8 L+₹7.5 L (60.9%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
30 Sept 2024, 6:00 pmClosed
Shri Vikas Tanwar, IDSE, GE (CME) Khadki
Garrison Engineer (CME) Khadki, Phugewadi, Dapodi, Pune - 411 012
REPAIR TO EXISTING INTERNAL DRAINS, CULVERT, PARAPETS, PRECAST COVERS ETC IN MD ACCN AT CME UNDER GE (CME) KHADKI
2024_MES_668673_1
8543/E8
Open Tender
Civil Works
Item Rate
240 days
Garrison Engineer (CME) Khadki, Phugewadi, Dapodi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer (CME) Khadki
₹50,000
Yes
4 Oct 2024
31 Aug 2024
2 Oct 2024
31 Aug 2024
30 Sept 2024
16 Sept 2024
1 Sept 2024 - 14 Sept 2024
Amount
Demolition of Brick work or stone / boulder / block masonery built in cement mortar complete all as specified incl coping.
M & L for pre cast PCC block mosonary Type C-1 1:3:6 exc 10 cm width and set in CM 1:4 all as specified
M&L for stone masonry randum rubble, well bonded, bedded and solidly hearted in CM 1:6 in drains retaining walls abutments brought upto courses etc. Complete all as specified and directed.
All as per Ser. Item No 4 above but except stone complete all as specified.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surfaces n.exc 40mm to face of stones and dressing of face , beds and joints, as specified of random rubble walling, uncoursed or brought upto course complete all as specified and directed.
Racking out joints / pointing to random rubble masonry built in cement mortar
M&L keyed pointing to random or polygonal rubble,uncoursed or brought up to coursing in cement mortar 1:4
M&L cement concrete 1:2:4 type B-2,(using 40mm graded aggregate) as in surface channels and drain complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc.
Demolition of cement concrete (un re-inforced) in ground floor and paving n.exc. 15 cm thick below or above ground level complete all as specified .
M&L cement concrete type D-2, 1:4:8(using 40mm graded stone aggregate) as in foundation , filling and mass concrete complete all as specified and directed.
M&L for PCC (1:3:6) type C1, using 20mm graded stone aggt as in coping, bands, plinth coarses, parapets etc like incl weathering,slightly rounded or chamfered throating complete all parapets as specified.
Formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings openings in concrete walls, floor, coping and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 5 cm but n exc 10cm wide, including fair finish surface etc complete all as specified and as directed.
Dismantling of RCC slab other than ground floors and similar suspended works complete all as specified.
M & L Reinforcement Cement concrete type B1 (1:2:4) using 20mm graded stone aggregate as in cover slab for drain & manholes etc. and directed .
Providing 1:2:, type B - 1(using 20mm graded stone aggregate), precast cement concrete in manhole cover etc complete all as specified and as directed. bonders (for stone walling) . and setting in mortar 1;6 etc. complete as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or Sloping)
M & L MS TMT Bars 10mm dia and over cut to length, bend to shape required, incl cranking, bending, for hooping for columns, hooking ends and binding with and incl MS wire (Annealed) not less than 0.9mm dia or securing with clips complete all as specified.
Ditto, but 5mm dia and over upto and including 10mm dia in cut to length, bend to shape required, incl cranking, bending, for hooping for columns, hooking ends and binding with and incl MS wire (Annealed) not less than 0.9mm dia or securing with clips complete all as specified.
Taking down cement or cement lime plaster on brick or stone walls etc incl racking out joints, hacking for key, scrubing down with water etc. complete all as spfd.
M&L 15mm thick cement plastering on concrete surfaces in CM (1:4) finishing surfaces even and smooth without using extra cement complete all as specified and as directed.
S&F For 110 mm , PVC (SWR) pipes single socketed, in any length with rubber ring joints,as in weep holes etc. Complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil etc. Complete all as specified and directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Dismantling stone slab and tiles of any description and thickness as in floor including cement mortar bedding and rubbish off the premisses complete all as specified and directed.
M & L For hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface
M&L for 100 mm thick PCC type B-2 (1:2:4) using 40 mm graded aggregate as in sub base etc complete all as specified and directed
M&L for 25mm thick PCC type B-1 (1:2:4) using 20mm graded aggregate as in floor finish with and including finished surface fair and even, groom finish etc complete all as specified and directed
M&L Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade 'A' etc complete all as specified and directed.
M&L for 20 to 25 mm thick rough dressed sand stone slab flooring, laid dry but jointed and pointed in cement mortar 1:4 etc. Complete all as specified and as directed.
All as per item No. 32 above but except stone
M&L for girt cushioning below interlocking paver block incl spreading and levelling complete all as specified and directed.
M&L for 60mm thick machine pressed precast concrete interlocking paver block reflective type coloured any shape and size confirming to IS 15658-2006 of M-35 grade , with grey cement and pigment complete all as specified and directed.
M& L for filleting in any position and to any shape in cement cement mortar 1:4 including all mitres, stops, including sectional area n. exc. 25 Sqcm etc complete all as specified and as directed.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick,set, jointed and pointed in neat cement slurry,with grey cement and pigment in floors over and including 15 mm thick screed bed or bedding layer in cm 1:6etc. Including dismantling old tiles etc. complete all as specified and directed.
Mukund Engineers and Contractors (BID ID -3110309)
Priyanka Power line (BID ID -3108217)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .