Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 LAccepted-AOC 10 244 R K PURAM SECTOR 4 R K PURAM NEW DELHI DELHI | CENTRAL DELHI | DELHI | 110002 | ₹3.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹3.6 LRejected-Finance BLOCK B SECTOR 26 CHANDIGARH | ₹3.6 L | L2 | Rejected-Finance L2 |
| 3 | L3₹4.1 LRejected-Finance CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹4.1 L | L3 | Rejected-Finance L3 |
Updated dates
Tender Value
₹5.2 L
EMD Value
₹10,500
Closing Date
3 Feb 2026, 12:00 pmClosed
Er. Chander Shekhar
Office of the Executive Engineer, Electrical Division No. 3 Sector-4, Chandigarh.
Providing renovation of Computer Labs at BCA Block in Post Graduate Govt. College for Girls sector-11, U.T. Chandigarh. (E.I. Work)
2026_CHD_90205_1
E3/47W/203
Open Tender
Electrical Works
30 days
Chandigarh
as per NIT
2 documents required · 2 mandatory
₹0
₹10,500
26 Feb 2026
21 Jan 2026
3 Feb 2026
21 Jan 2026
3 Feb 2026
21 Jan 2026
DSR Item No.1.10Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
DSR Item No.1.15Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/Recessed steel/PVC conduit including dismantling as required.
Group C
DSR Item No.1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm.
DSR Item No.1.21Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
DSR Item No.1.24Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
3 pin 5/6 A socket outlet
DSR Item No.1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
DSR item no. 1.26Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
DSR Item No.1.31Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
DSR Item No.1.32Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
DSR item no. 1.33Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
DSR item no. 5.1Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
DSR item no. 5.7Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
DSR Item no. 2.2Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
63/100 A,30KA, FPMCCB
DSR Item no. 2.4Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
DSR Item no. 2.10Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole and neutral
DSR ITEM No.2.16Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
DSR item no. 8.7 LED Panel light 2x2 ft. (System lumen efficacy≥120 <135 lm/Watt)Supplying, Installation, Testing & Commissioning ofPanel light 2x2 ft., of following body material andconstruction as per IS : 10322 with driver as per therequirement with Driver efficiency >85%, Operatingvoltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -5 0C to 40 0C, internal\ surge protection of 2.5 KV with Short & Open circuitprotection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) <19, Flicker free,(flicker should be below 5 %), life time (LED, Driver& electrical circuitry), of minimum 50000 BurningHours with , 70% of initial Lumen maintained tilllife ends, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(StandardDeviation Color Matching) <3, Maximum powerconsumption should not more than the specifiedrating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. Completein all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copperconductor single core cable and earthing etc. asrequired with Minimum 5 year OEM warranty.System lumen efficacy ≥120 <135 lm/Watt output.LM79 & LM80 Test report and all testingrequired for LED fixtures as per BIS shall besubmitted. Shape size and CCT shall be asapproved by Engineer-in-Charge as perrequirement. (Thermal management: heat sink ofaluminium housing such that LED junctiontemperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
DSR item no. 8.10 LED Batten light (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of LEDsurfacemounted Batten light of following body material and constructionas per IS : 10322 with driver (Replaceable) as per therequirement with Driver efficiency >85%, Operating voltageAC 140-270 Volt, freq 50/60 hz, Operating temp range -5 degto 40 deg centigrade, internal surge protection of 2.5 KV withShort & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI >80 , Flicker free (flicker should be below 5 %), life time(LED,Driver& electrical circuitary), of minimum 50000Burning Hours with , 70% of initial Lumen maintained tilllife ends,CCT 3000°K / 4000°K / 5700°K /6500°K (As perANSI Bin), SDCM(Standard Deviation Color Matching) <3,Maximum power consumption should not more than thespecified rating and Fixture shall be of relevant BIS standardand trade mark certificate ( T.C.). Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing. OEMmust have its own in house NABL lab setup for all testingfacilities for LED fixtures. complete in all respect i/c externalconnections with 1.5 sq mm FRLS/HFFR, PVC insulatedcopper conductor single core cable and earthing etc. as requiredwith Minimum 5 year OEM warranty. System lumen efficacy≥120 <135 lm/Watt output . LM79 & LM80 Test report and alltesting required for LED fixtures as per BIS shall besubmitted. Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermalmanagement: heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body(Thickness > 1.20 mm)
Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)
DSR item no. 9.2 Brush Less Direct Current (BLDC) fan without remote. Supply, Installation, Testing and Commissioning of ceiling fanwith Brush Less Direct Current (BLDC) Motor, class ofinsulation: B, 3 nos. metal(Aluminum alloy) blades, 30 cmlongdown rod, 2 nos. canopies, shackle kit, safety rope, copperwinding, steel/Al body Power Factor not less than 0.9, ServiceValue (CM/M/W) minimum as below, 350 RPM (tolerance as perIS : 374-2019), THD (Total Harmonic Distortion) less than 10%,suitable for operation with regulator for speed control and allremaining accessories including safety pin, nut bolts, washers,temperature rise=75 degree C (max.), insulation resistancemore than 2 mega ohm, suitable for 230 V, 50 Hz, single phaseAC Ceiling Fan compliant to IS 374:2019 fan Supply, earthingetc. complete as req.
1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min(Minimum)
Supply and fixing of G.I box of size 200 mm x 150 mm suitable for accommodate the following accessories along with Modular switch with modular plate and cover for switches in recess / surface etc. as required for Computer Point with 4 Nos. 5/6 Amp. Modular type switch and 4 Nos. 3 pin 5/6 Amp. Modular type socket outlet. The job includes the cost of making interconnections with suitable copper wire and suitable size PVC conduit pipe, painting of box with approved paint and other petty material required to complete the job to the entire satisfaction of Engineer-in-Charge at site.
Supply and Erection of B.L. Holder of make Anchor Penta/ Havells (Reo)/ Goldmedal/ Lauritz Knudsen ISI marked on the existing junction box/ wooden block including making the connection etc as required. The job includes the all labour and petty material charges required to complete the job to the entire satisfaction of E.I.C. of work.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 26.57 MB
BOQ_110313.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid