Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹97.1 LAccepted-AOC HOUSE NO 20 BAGHARBARI VIDYANAGAR 2 PANJABARI GUWAHATI ASSAM 781037 | KAMRUP METRO | ASSAM | 781037 | L1 | Accepted-AOC L1 | |
| 2 | L2₹97.1 L+₹300 (<0.01%)Rejected-Finance C O NINGNA RAM DAS HOUSE NO 15 GREEN VIEW COLONY TETELIA GUWAHATI PO MALIGAON PS JALUKBARI KAMRUP METRO 781011 | GUWAHATI | KAMRUP METRO | ASSAM | 781011 | L2 | Rejected-Finance L2 |
Tender Value
₹97.1 L
EMD Value
₹1.9 L
Closing Date
22 Feb 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
KC Boro
SE PWD BLDG CIRCL KOKRAJHAR
Construction of RCC Ground Floor Tribal Rest house at Kajalgaon under Sidli LAC District Chirang.TN_613
2024_BoTC_36239_1
TECH_17/SE_B/2021_22/25
Open Tender
Civil Works - Building
Works
365 days
Chirang
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,914
₹1.9 L
Yes
7 Mar 2024
14 Feb 2024
22 Feb 2024
14 Feb 2024
22 Feb 2024
14 Feb 2024
14 Feb 2024 - 22 Feb 2024
Amount
Const. of Ground Floor Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth leadupto 50m and lift upto 1.5m, as directed by Engineer-in-Charge. 2.6.1 All kinds of soil.
Brick on edge flooring with bricks of class designation 7.5 on a bed of 12mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 11.1.1 1:4 (1 cement: 4 coarse sand).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level: 1:3:6 (1 Cement:3 coarse sand (zone-III) : 6 graded stone.
Steel reinforcement for RCC work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level. 5.22 C.1 Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.9.1 Foundations, footings, bases of columns, etc. for mass concrete.
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers.
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts.
5.9.3 Suspended floors, roofs, landings, balconies and access platform.
5.9.7 Stairs, (excluding landings) except spiral-staircases.
5.9.19 Weather shade, Chajjas, corbels etc., including edges.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level: 5.1.2 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III):3 graded stone aggregate 20mm nominal size).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in : 6.1.1 Cement mortar 1:4 (1 cement:4 coarse sand).
Supplying amd filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III):3 graded stone aggregate 20mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 5.2.2 1:1.5:3 (1 cement:1.5 coarse sand (zone-III): 3 graded stone aggregate 20mm nominal size).
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size).
Half Brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.1 Cement mortar 1:3 (1 cement: 3 coarse sand).
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.2 Size of the Tile 600x600mm
Providing and laying ceramic glazed floor tiles of size 300x300mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS: 15622 of approved make in colours such as white, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. complete.
Providing and fixing M.S. grills or required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat. 9.48.1 Fixed to steel windows by welding
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling sectiong 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermaediate chennel with connecting clips made out of 2.64mm dia x 230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter chennels suitably. 12.45.1 12.5mm thick tapered edge gypsum plain board conforming to IS:2095-(Part-I): 2021 (Board with BIS certification marks).
15mm cement plaster on rough side of single of half brick wall of mix: 13.5.1 1:4 (1 cement: 4 coarse sand)
Providing wood work in frames of doors, windows, clerestory windows 9.1.1 Second class teak wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately). 9.5.1 Second class teak wood 9.5.1.1 35mm thick shutters
Providing and fixing factory made P.V.C door frame of size 50x47mm with awall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150mm long brackets of 15x15mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size, complete as per manufacturer's specification and dirction of Engineerin-Charge.
24mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24mm and wall thickness 2mm (+ 0.2mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220mm having wall thickness 1.0mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20mm and 1mm (+ 0.1mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24mm and 2mm (+0.2mm) wall thickness, fixed to the shutter styles by means of plastic/glavanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620mm, having over all thickness of 20mm and 1mm (+ 0.1mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter).
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 10.26.1 M.S. tube
Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: 13.98.1 One or more coats on old work.
Finishing walls with Acrylic Smooth exterior paint of required shade: 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 Kg/10 sqm).
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III): 6 graded stone aggregate 20mm nominal size) over 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Applying priming coat: 13.50.1 With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood).
Providing and applying two coats of fire retardant paint on cleaned wood/ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacture to make the surface fire retardant.
Painting steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Construction of Septic Tank Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed by Engineer-in-charge. 2.6.1 All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level: 1:3:6 (1 Cement:3 coarse sand (zone-III) : 6 graded stone.
Steel reinforcement for RCC work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level. 5.22C.1 Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.9.3 Suspended floors, roofs, landings, balconies and access platform.
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: 6.2.1 Cement mortar 1:4 (1 cement: 4 coarse sand).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20mm nominal size derived from natural sources).
15mm cement plaster on rough side of single or half brick wall of mix: 13.5.1 1:4 (1 cement:4 coarse sand).
Sanitary Installation Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580 x 440mm with integral type foot rests.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm or 340x410x265mm sizes respectively.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. 18.7.3 25mm nominal outer dia Pipes
18.7.2 20mm nominal outer dia Pipes
18.7.1 15mm nominal outer dia Pipes
Providing and fixing PTMT urinal cock of approved quality and colour. 17.76.1 15mm nominal bore, 80mm long, 42mm high and 30mm
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630x450mm with a pair of 15mm C.P. brass pillar taps
Providing and fixing C.P. brass shower rose with 15 or 20mm inlet: 18.22.1 100mm diameter
Providing and fixing brass bib cock of approved quality: 18.15.1 15mm nominal bore
Providing and fixing brass stop cock of approved quality: 18.16.1 15mm nominal bore
18.16.2 20mm nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 18.12.7 65mm dia nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes. 18.9.5 40mm nominal outer dia pipes
18.9.4 32mm nominal outer dia pipes
18.9.3 25mm nominal outer dia pipes
Supplying, assembling, lowering and fixing in vertical position in bore 23.4.1 100mm nominal size dia
24.4.2 150mm nominal size dia
23.4.3 200mm nominal size dia
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for intet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 18.12.7 65mm dia nominal bore
Providing and placing in position filters of 40mm diameter G.I. pipe with brass strainer of approved quality.
Electrical Work Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1.8.1 Group A
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 1.14.1 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire
1.14.2 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
1.14.3 2 x 4 sq.mm + 1 x 4 sq.mm earth wire
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing call bell/buzzer suitable for single phase, 230 V, complete as required.
Supplying and fixing of following ways, surface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 2.5.1 4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections. 2.10.1 Single pole
2.10.3 Double pole
2.10.5 Triple pole and neutral
Earthing with G.I. earth pipe 4.5 metre long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/cock and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required.
Supplying with including fitting fixing of ceiling fan etc. as directed by Deptt.
Supplying with including fitting fixing of 20 Watt LED Tube Light etc. as directed by the Deptt.
Supplying with including fitting fixing of Exhaust Fan etc. as directed by the Deptt.
Supplying with including fitting fixing of LED Bulb 9 Watt etc. as directed by Deptt.
Supplying with fitting fixing of 1HP single phase Monoblock pump set.
GAJI RAM DAS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .