Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC DB 6 A HARI NAGAR NEW DELHI 64 | L1 | Accepted-AOC As per NIT | |
| 2 | L2₹7.2 L+₹1.0 L (16.6%)Rejected-Finance UC I USHA PARK HARI NAGAR NEW DELHI 64 | NEW DELHI | DELHI | 110001 | L2 | Rejected-Finance As per NIT |
Tender Value
₹8.0 L
EMD Value
₹15,907
Closing Date
13 Feb 2024, 3:00 pmClosed
Executive Engineer
Office of the Executive Engineer,EE(Elec), WZ
Improvement/upgradation of Electrical installations in Municipal Primary School Nawada Village Ward No.114 under West Zone.
2024_MCD_184602_1
MCD/TR/1170/2024_6_1_1/1
Open Tender
Electrical Works
Item Rate
90 days
Nawada
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹15,907
4 Mar 2024
6 Feb 2024
13 Feb 2024
6 Feb 2024
13 Feb 2024
6 Feb 2024
6 Feb 2024 - 13 Feb 2024
Amount
OD25474/2023-2024:DSR-2022 (1.10.3 ) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. ( Group C )
OD25475/2023-2024:DSR-2022(1.15.3) Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required.Group C
OD25477/2023-2024:DSR-2022 (1.16) Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
OD25491/2023-2024:DSR-2022 (1.14.2 ) Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2x2.5 sq.mm+1x2.5 sq.mm earth wire)
OD25492/2023-2024:DSR-2022 (1.14.7 ) Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (4 x2.5 sq.mm+2 x2.5 sq.mm earth wire)
OD25493/2023-2024:DSR-2022 (1.14.3) Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2x4sq.mm+1x4 sq.mm earth wire)
OD25494/2023-2024: DSR-2022 (1.17.12) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 3 x 2.5 sq. mm
OD25495/2023-2024:DSR-2022 (1.17.15) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (6*2.5)sqmm
OD25496/2023-2024:DSR-2022 (1.17.21) DSR-2022 (1.17.15) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (3*4)sqmm
OD25497/2023-2024:DSR-2022 (1.17.30) DSR-2022 (1.17.15) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (3*6)sqmm
OD25498/2023-2024:DSR-2022 (1.23.1) Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (5/6 amp switch)
OD25499/2023-2024:DSR-2022 (1.23.4) Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (3 pin 5/6 amp socket out let)
OD25500/2023-2024:DSR-2022 (1.23.3) Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. ( 15/16 amps switch )
OD25501/2023-2024:DSR-2022 (1.23.5) Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. ( 6 pin15/16 amp socket outlet )
OD25505/2023-2024:DSR-2022 (2.3.2) Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (8 way Double door)
OD25506/2023-2024:DSR-2022 (2.3.3) Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (12 way Double door)
OD25541/2023-2024:DSR-2022 (2.10.1) Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single pole)
OD25542/2023-2024:DSR- 2022( 2.12.1) Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 40 A
OD25543/2023-2024:DSR-2022 (2.12.2) Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (63 amps)
OD25544/2023-2024:DSR-2022 (2.2.1) Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (100 A, 16 KA,TPMCCB )
OD25545/2023-2024:DSR-2022 (2.2.4) Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (200 A, 16 KA,TPMCCB )
OD25546/2023-2024:DSR-2022 (1.50.1) Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (Upto 450 mm sweep)
OD25548/2023-2024:DSR-2022 (1.22.2) Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. (100 mm X 100 mm X 60 mm deep)
OD25551/2023-2024:DSR-2022 (1.22.5) Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. (180 mm X 100 mm X 60 mm deep)
OD25552/2023-2024:DSR-2022 (1.22.9) Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. (200 mm X 250 mm X 60 mm deep)
OD25554/2023-2024:DSR-2022 (1322 ) Supply of 3 mm thick phenolic laminated sheet
OD25568/2023-2024:DSR-2022 (5.1) Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
OD25569/2023-2024:DSR-2022 (5.12) Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
OD25570/2023-2024:DSR-2022 (5.18) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
OD25571/2023-2024:DSR-2022 (7.6.1) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
OD25572/2023-2024:DSR-2022 (7.7.1) Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required (Upto 35 sq. mm (clamped with 1mm thick saddle))
OD25573/2023-2024:DSR & AOR (E&M) Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
OD25582/2023-2024:Supply of 12" (300mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter, blade etc as required
OD25587/2023-2024:SITC of single phase monoblock pump set complete with all accessories workable on 240/515 volts, 50 Hz AC supply (a) 1 HP (0.75 KW) single phase pump set, head from 12-30 metre suction and delivery 25x25 mm.
Approved Rates
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.30.a:SITC of 150W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =150 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
122.2.155.(b):Supply, Installation, testing and commissioning of cubical type control panel board for single phase & Three Phase submersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc including connections etc as reqd. 1.5 HP (Single Phase)
122.2.236:Rewinding of AC ceiling fan of all sizes and make including oiling, greasing as required New Model (Light Weight)
SRI BALAJI ELECTRICALS
Bidder Name
AMAN ELECTRICALS
SRI BALAJI ELECTRICALS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .