| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED DUE TO L1 | |
| 2 | L2₹42.2 L+₹1.2 L (2.99%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L2 | Rejected-Finance REJECTED DUE TO HIGHER RATE | |
| 3 | L3₹42.8 L+₹1.8 L (4.42%)Rejected-Finance GANDHI PARK ROAD TINSUKIA ASSAM PIN 786125 | TINSUKIA | ASSAM | 786125 | L3 | Rejected-Finance REJECTED DUE TO HIGHER RATE | |
| 4 | L4₹43.0 L+₹2.1 L (5.04%)Rejected-Finance 0 VILLAGE SYANGAWALI TEH TEHSIL SADULSAHAR SRIGANGANAGAR SRIGANGANAGAR RAJASTHAN 335001 | GANGANAGAR | RAJASTHAN | 335001 | L4 | Rejected-Finance REJECTED DUE TO HIGHER RATE | |
| 5 | L5₹43.5 L+₹2.6 L (6.23%)Rejected-Finance NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L5 | Rejected-Finance REJECTED DUE TO HIGHER RATE |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
29 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE LEKHAPANI
TINSUKIA, ASSSAM
SPECIAL REPAIR TO BUILDING NO T-4 ALONGWITH PROVN OF REPAIR BAY AND JAFRI WALL NEAR BLDG NO T-1 AT LEKHAPANI MILITARY STATION UNDER GE LEKHAPANI
2021_MES_461909_2
8613/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE LEKHAPANI
Class D and category a (i)
4 documents required · 4 mandatory
₹500
₹80,000
Yes
14 Oct 2021
13 Sept 2021
1 Oct 2021
13 Sept 2021
29 Sept 2021
20 Sept 2021
60 days
Amount
Dismantling of plain or corrugated steel sheeting any guage, thickness including Nanital or similar pattern roof coverings complete all as specified and as directed.
M&L for pre-painted hot dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
M&L for hot dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550MPa as in ridge/valley/gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
Demolition of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605mm x 605mm in true horizonatal level, hot dipped galvanised steel sections consisting of main “T” runner with suitably spaced joints to get required length and size 24mm x 38mm made from 0.30mm thick (Min) sheet spaced at 1200mm centre to centre and cross “T” of size 24mm x 28mm made of 0.30mm thick (Min) sheet, 1200mm long spaced between main “T” at 600mm centre to centre to form a grid of 1200mm x 600mm and secondary cross “T” of length 600mm and size 24mm x 28mm made of 0.30mm thick (Min) sheet to be interlocked at middle of the 1200mm x 600mm panel to form grids of 600mm x 600mm and wall angle of size 24mm x 24mm x 0.4mm. Main “T” runner to be suspended from ceiling using 4mm GI rods, 1200mm x 600mm centre to centre all complete for all heights as per specifications and as directed by Engineer – in - Charge.
S&F 4mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 2 to 3 mm dia GI wire hangers fixed with steel dash through fasteners from purlins with butterfly clips, hold down clips, with provision of ligh fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detector etc. complete all as per manufacturer instructions and all as shown on Drawing No. CESZ/2019/TD-42, Sheet No. 1/1.
Taking down timber roof trusses, coupled rafters or trussed beams of clear span above 4 mtrs and upto 8 mtrs for renewal of any defective members (timber renewed to be measured separately) and reassembling complete all as specified and as directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Dismantling timber scantlings in unframed timber work 40 sq.cm and over in section, in any position complete all as specified and as directed.
Dismantling timber fillets, rails, posts, rafters, purlins, etc in unframed work under 40 Sqcm in section in any posotion complete all as specified & directed.
Fixing only,mild steel work as in roof trusses and others (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410 -W (GdeE- 250) quality A.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft and loose soil.
Supply & Fixing mild Steel work in tubular trusses etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161 or 1239 grade St.-240 complete all as specified and directed.
M&L for preparation of old painted surfaces of steel of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed.
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work & precast concrete articles complete all as specified & directed.
Demolition of unreinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of reinforced cement contrete of any description in any position not otherwise specifically provided for complete all as specified & directed.
M & L for Plain Cement Concrete, 1:4:8 ,Type D2 (using 40 mm graded crushed stone aggregate) in foundations bed concrete, filling and mass concrete complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Description all as per item No 21, but except bricks.
M&L for brick work with sub class old size 'B' bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls complete as specified and directed.
Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
S&F mild steel TMT bar 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
S&F mild steel TMT bar 6 to 8 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
Ditto, as per item No 26 but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders
M&L RCC , 1:2:4, Type B1 using 20mm graded crushed stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span etc complete.
M&L for Type B1, 1:2:4 (20 mm graded crushed stone aggregate ) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M&L for rendering 15mm thick in Cement Mortar 1:4 on fair faces of brick or concrete surfaces in two layers 5mm thick finishing layer over 10mm thick backing layer finished fair and even with mixing water proofing compound to top layer as per manufacturers instruction and as directed (WPC will be measured separetely).
Supply only liquid water proofing compound of approvad brand complete all as specified and directed.
M&L for rendering 10.mm thick plaster in cement mortar 1:6 on fair faces of brick work or concrete surfaces including finishing top even and smooth without using extra cement complete all as specified & directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and preparing surfaces as directed by applying thin layer of wall care putty of 1 to 2 mm thick and finally applying two coats of distemper oil emulsion over a coat of primer complete all as specified & directed.
Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5sqm each and making good to disturbed surfaces and removing from site of work complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5sqm but not exceeding 4.0sqm each and making good to disturbed surfaces and removing unserviceable materials from site of work complete all as specified and directed by the Engineer-in-Charge.
Pressed steel frames 1.2mm thick (105 x 60) mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed.
M&L for plain cement concrete (1:3:6), type C-1, (using 20mm graded crushed stone aggregates) as in bed block, blocks for holdfasts, filling in pressed steel door frames , benching slightly rounded or chamfered angles & throating etc including necessary use & waste of form work complete all as specified and directed.
S&F 30 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides & fixed to chowkats complete all as specified & directed.
S&F 200 mm size, aluminium anodised , barrel tower bolts of extruded section & fixed complete all as specified and as directed.
S&F 150mm size aluminium handles, cast type, anodized and fixed complete all as specified & as directed.
S&F 250mm length of bolt, aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified & as directed.
M&L preparing new wood & wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified & directed.
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in squares n exc 0.5sq. m in each pane complete all as specified and as directed
S&F framed work such as griils, grating, angle iron door frames etc., with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, laders, framed balusters, walk ways, railings frame work of water tanks and similar work conforming to Fe-290. Gde E-165 complete all as specified & as directed.
Cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required
M&L for preparation of new or previously steel surfaces of any description, over 10 cm width or girth, not otherwise described and evenly applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. Including brushing neat cement slurry with 3.0kg of cement per sq. metre
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:3) as in screed bed of wall tiles complete all as specified and directed.
S&F glazed ceramic coloured tiles in vertical surface 350x250x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match all as directed.
M&L non-skid colour joint free ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc over and including screed bed or bedding layer of mortar 15mm thick in Cement Mortar 1:6 for laying floor finishes set and jointed in neat cement slurry and pointed in white or coloured cement to match.
M&L for 75 mm thick Cement concrete 1:3:6, type C-2, (using 40 mm graded crushed stone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with hot bitumastic mix in proportion of bitumen and sand 1:2 complete as specified & directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as directed.
Removing execavated material to a distance exc 500m and n.exc 1.50 km and depositing where directed.
M&L for cement concrete 1:5:10 type E2 (using 40mm graded crushed stone aggregate) in foundation filling and mass concrete complete all as specified and directed.
Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade complete all as specified and directed.
M&L for providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregate) surface finished even and smooth without using extra cement complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 mtr deep for foundation etc, or for shafts, wells, pier holes, manholes and cesspits etc not exc 10 Sqm on plan n.exc 1.5 in depth and and getting out in soft / loose soil comlplete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m radius built in cement mortar 1:4 complete all as specified and directed.
Returning filling in, including spreading leveling watering and well ramming in layers n.exc 25cm thick each , in any type of soil complete.
M&L removing excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L plan cement concrete type B-1, 1:2:4, type B-1, (using 20mm graded crushed stone aggregate) parapets, wall copings, including use and waste of form work complete all as specified and directed.
M&L for cement concrete 1:2:4, type B-2 using 40 mm graded crushed stone aggregate as in surface channels and drains all as specified and as directed.
M&L for 450 mm bore dia reinforced concrete pipes, class NP 3 with one collar per length
M&L for RCC nominal mix 1:2:4, type B1, (20 mm graded crushed stone aggregate) foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
S&F Rolled Mild Steel sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates etc, confirming to Fe 410 - W (Gde-E-250) quality - A as steel gates etc complete.
S&F Mild steel Plates (Plain or chequred) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe-290 (Gde E-165).
S & F fan hooks made of MS clamp deformed to proper shape including nut & bolts and drilling/cutting roof as required at site and fixing fan hook with existing steel reinforcement all as directed by engr-in-charge.
Providing precast cement concrete louvres and jallies, 40 mm thick (measured solid), including all mould- ings 1:2:4, type B0 (12.5mm) graded crushed stone aggregate) set in cement mortar 1:4.
Taking down copper/aluminium point wiring, (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M & L for point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables of 2 run of 1.5 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size through and including PVC casing & caping terminated in PVC box surface mounted of suitable size for fixing of switches, sockets, fan regulators etc for the following: - (a) One light point controled by one one way 5 Amp switch
(b) One fan point controlled by one , one way 5 Amp switch
(c) One 5 pin socket outlet 05 Amp on independent board .
(d ) One 5 pin socket outlet 05 Amp on same board with other switches
All as per item No 73 here-in-before for one 15 Amps socket outlet but using 2.5 sq mm,copper conductor with 2.5 sq mm, PVC insulated single core cable for earth continuity conductor.
S&F LED tube light fitting 4 ft. 1 x 18 watt with 230 volts, with bipin holder connector block, LED retrofit tube rod etc complete with all accessories internally pre-wired and fixed to walls/ceiling with screw on round PVC blocks including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC).
S&F fan regulators electronic stepped type all as directed.
S&F switch piano flush type, 6 amps, 230V AC,single pole, one way.
S&F switch socket combination multipurpose suitable for 2 pin and 3 pin 6 amp flush type complete.
S&F switch socket combination multipurpose suitable for 2 in 1 , 3 pin 5 & 15 amps flush type complete.
S&F socket outlet type 2 in 1 3/5 pin 5 Amps .
Supply & fix ceiling rose, 3 terminals, surface bakelite, PVC/Polycarbonate.
M & L sub main wiring complete with 2 runs of 6 sq mm FRLSH ,single core,PVC insulated,unsheathed cable,1100 volts grade,multi standard with copper conductor drawn through and including PVC casing caping and accessories on surface wall/floors/concealed etc. with one run of PVC insulated 6 sq mm FRLSH copper conductor for earth continuity conductor including taking down old US wiring all as specified and directed Note :- Two runs of cable one run of casing caping and one run of copper wire shall be measured as one unit length.
S & F MCB SP 6 to 32 Amps 240 volts complete.
S & F MCB SPN 6 Amps to 32 Amps 240 volts complete.
S&F single pole and neutral DB wall mounting type,240 Volts,8 Way with 200 Amps rated bus bar,double door suitable for fixing MCB's including connecting etc and taking down unserviceable DB , main switch complete.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways complete all as specified & directed by Engineer-in-Charge.
Supply and fixing LED bldg security light fitting 48W watt with 230 Volts with IP 66. High Impact resistance complete with all accessories internally pre-wired and fixed to walls complete all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded galvanized steel strip or wire armored electric power cables(heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core.
S/F FRP cable junction box of suitable size to accommodate two nos. aluminium bus bars and one no MCB 6 Amps single pole including all connected accessories to integrate the set complete all as specified and directed.
Supply and laying 40 mm dia GI tubing light grade complete with all fittings (ISI Marked) lain in trenches/fixed on pole/wall complete including taking down old unsv GI pipe all as directed by Engr-in-Charge.
MAZUMDAR ENTERPRISE
Bimal Trading Company
M/s. R. K. Trading Company
MAA COMMUNICATION
ms singh construction
RIA CONSTRUCTION
M/s PRABIR ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .