Tender Value
₹92 L
EMD Value
₹1.8 L
Closing Date
28 Dec 2022, 4:00 pmClosed
DY. GENERAL MANAGER
Office of the Deputy General Manager, JKPCC Ltd., Unit Udh/ Reasi.
Execution of Balance work for the construction of RCC Ramp at District Hospital Reasi.
2022_PWDJK_198659_1
e-NIT No. 02/UDH-REASI of 2022-23 Dt. 06-12-2022.
Open Tender
Civil Works
Item Rate
90 days
REASI
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Yes
Financial Controller, JKPCC Ltd.
₹1.8 L
Yes
General Manager, JKPCC Jammu.
1 Feb 2023
6 Dec 2022
29 Dec 2022
6 Dec 2022
28 Dec 2022
7 Dec 2022
14 Dec 2022
Amount
Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by All kinds of soil.
Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil.
Disposal of excavated earth obtained from cutting through MT with lead upto 5KM foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Treatment of soil under existing floors using chemical emulsion (Chlorophriphos/ Lindane E.C. 20% with 1% concentration) @ one litre per hole, 300mm apart including drilling 12 mm diameter holes
Spplying and filling in plinth with fine sand under floors including, watering, dressing complete.
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
Providing and laying in position brick concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto first floor level with: 1:5:10 (1 cement : 5 coarse sand : 610graded stone aggregate 40 mm nominal size)
FORM WORK Centering and shuttering including strutting, propping etc. and removal of form for:
Suspended floors, roofs, landings, balconies and access platforms.
Lintel, beams, plinth beams, girders, bressumers and cantilevers.
Columns, pillars, piers, abutments, posts and struts.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto roof level wire. Cold twisted bars
Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs,balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineerin-
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level in foundations and plinth including curing in :
CEMENT PLASTER IN TWO COATS 18mm Cement plaster in two coats under layer 12mm thick cement plaster 1 : 5 (1 cement : 5 coarse sand) finished with a top layer 6mm thick cement plaster 1 : 6 (1 cement : 6 fine sand)
15MM CEMENT PLASTER 10 mm cement plaster to ceiling of mix 1 :4(1 cement : 4 fine sand)
10mm Cement plaster on the rough side of single or half brick wall of mix:
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4
Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 8.3.2 Granite Work
Providing and laying antiskid floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.
VITRIFIED FLOOR TILES Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, in skirting, riser of steps, laid with cement based
Finishing walls with texture paint of required shade on New work (two or more coats applied @ 3.28 litre/10 sqm) over and incl. base coat of exterior primer applied @ 2.20kg/ 10 sqm.
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
Painting with silicon and acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered 13.59.2 Two coats
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) Powder coated aluminum (minimum thickness of powder coated 50 microns
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately Powder coated aluminum (minimum thickness of powder coated 50 microns)
P/F of ACP sheet of zero bond make incl.cutting complete.
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete 50 mm thick with 20mm nominal size stone aggregate.
Supplying and stacking of good earth at site including royalty (earth measured in stacks will be reduced by 20% for payment)
Supplying and stacking at site dump manure from approved source including carriage complete (manure measured in stacks will be reduced
Rough dressing of the trenched ground including breaking clods
Providing and fixing M.S. flat iron tree guard 60 cm dia. and 2 m high above ground level formed of 4 nos. 25x6 mm, 2.25m long and 8 nos. 25x3 mm 2 m long vertical M.S. flats riveted to 3 nos.25x6 mm MS flat iron rings in two halves, fixed together at site with required 6 no. of 8 approved brand and manufacture over a coat of primer. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered CPWD/PWD/any other approved name The tree guard shall be suitably fixed to the ground by embedding four legs of the tree guard in pits of suitable dia. and to a depth of 25 cm, refilling the pits with soil and ramming, complete in all respect as per satisfaction on direction of Officer-in-charge
Supply and plantation of Rose
Supply and plantation of Aeroceria
Supply and plantation of Chandani
Supply and plantaion of green patti
ELECTRICAL WORKS
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. ( Group C)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 core 10 sqmm al. cable
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
63A tpn mcb with LT bus bar
Earthing with G.I. earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying and fixing of surface 24 watt LED type. Ceiling light including connections etc as required.
Supplying and fixing of surface mounted 20/22 watt batten LED tube fiiting 4 feet long including connections etc as required.
JAS EXCAVATORS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .