Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹57.7 LAccepted-AOC | ₹57.7 L Quoted ₹59.7 L | 1 | Accepted-AOC Approved |
| 2 | 2₹59.8 L+₹8,066 (0.14%)Rejected-AOC HOUSE NO 342 DHURI GATE PADHIAN WALI STREET SANGRUR PUNAJB 148001 | SANGRUR | PUNJAB | 148001 | ₹59.8 L+₹8,066 (0.14%) | 2 | Rejected-AOC Approved |
| Sl No | Description | Qty | Unit | AMBEY CONSTRUCTION CO L2 | shanu construction comapny L1 |
|---|---|---|---|---|---|
| 1.00 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with excavated surplus soil. Mechanical Means depth upto 3 Mtr | 1,794.49 | Cum | 78.11 ₹1,40,167.61 Lowest | 78.11 ₹1,40,167.61 Lowest |
| 2.00 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type | 40.71 | Cum | 4,678 ₹1,90,441.38 Lowest | 4,678 ₹1,90,441.38 Lowest |
| 3.00 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) | 65.4 | Sqm | 236 ₹15,434.4 Lowest | 236 ₹15,434.4 Lowest |
| 4.00 | Supply of D.I. Pipe DI-K7 900mm i/d pipe | 218 | M | 20,460 ₹44,60,280 | 20,431 ₹44,53,958 Lowest |
| 5.00 | Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage, cost of rubber ring.
D.I. Pipe as per IS 8329 DI-K7 900mm i/d pipe lines laid complete | 218 | M | 370 ₹80,660 | 362 ₹78,916 Lowest |
| 6.00 | Providing, Laying, fixing & jointing of ISI Marked H.D.P.E. Pipes as per ISI - 4984- 1995 casting along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
500mm o/d pipe PE 80, PN 2.5 as per IS 4984:2016 | 218 | M | 3,871 ₹8,43,878 Lowest | 3,871 ₹8,43,878 Lowest |
| 7.00 | Reinforced cement concrete M-15 grade boundary pillar of standard design as per IRC 26-1967 fixing in position including painting and printing etc. complete as per technical clause 806 of MORT&H specifications | 1 | Each | 4,000 ₹4,000 Lowest | 4,000 ₹4,000 Lowest |
| 8.00 | 200 meter Stone
Reinforced cement concrete M-15 grade 200 meter stone of standard design as per IRC 26- 1967 fixing in position including painting and printing etc. complete as per technical clause 804 of MORT&H specifications | 4 | Each | 704 ₹2,816 Lowest | 704 ₹2,816 Lowest |
| 9.00 | Supply & fixing of HDPE BUTT FUSION BEND 90 degree
500mm | 2 | Each | 29,541 ₹59,082 Lowest | 29,541 ₹59,082 Lowest |
| 10.00 | Supply & fixing of HDPE BUTT FUSION BEND 45 degree
500mm | 2 | Each | 43,898 ₹87,796 Lowest | 43,898 ₹87,796 Lowest |
Tender Value
₹56.6 L
EMD Value
₹1.1 L
Closing Date
11 Mar 2026, 3:00 pmClosed
Executive Engineer, BML Division, Patiala
XEN, BML Division, Jail Road, Patiala
Laying of Riser Main pipe RD 1780 to 1995 along with distribution pipeline for Samrala Major Lift Scheme
2026_WR_160746_1
78/25-26
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
90 days
Rupnagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹1.1 L
20 Apr 2026
18 Feb 2026
12 Mar 2026
18 Feb 2026
11 Mar 2026
18 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with excavated surplus soil. Mechanical Means depth upto 3 Mtr | 1,794.49 | Cum | 1 | ₹1,794.49 |
| 2 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type | 40.71 | Cum | 1 | ₹40.71 |
| 3 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) | 65.4 | Sqm | 1 | ₹65.4 |
| 4 | Supply of D.I. Pipe DI-K7 900mm i/d pipe | 218 | M | 1 | ₹218 |
| 5 | Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage, cost of rubber ring.
D.I. Pipe as per IS 8329 DI-K7 900mm i/d pipe lines laid complete | 218 | M | 1 | ₹218 |
| 6 | Providing, Laying, fixing & jointing of ISI Marked H.D.P.E. Pipes as per ISI - 4984- 1995 casting along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
500mm o/d pipe PE 80, PN 2.5 as per IS 4984:2016 | 218 | M | 1 | ₹218 |
| 7 | Reinforced cement concrete M-15 grade boundary pillar of standard design as per IRC 26-1967 fixing in position including painting and printing etc. complete as per technical clause 806 of MORT&H specifications | 1 | Each | 1 | ₹1 |
| 8 | 200 meter Stone
Reinforced cement concrete M-15 grade 200 meter stone of standard design as per IRC 26- 1967 fixing in position including painting and printing etc. complete as per technical clause 804 of MORT&H specifications | 4 | Each | 1 | ₹4 |
| 9 | Supply & fixing of HDPE BUTT FUSION BEND 90 degree
500mm | 2 | Each | 1 | ₹2 |
| 10 | Supply & fixing of HDPE BUTT FUSION BEND 45 degree
500mm | 2 | Each | 1 | ₹2 |
stage.html
html • 0.04 MB
techsummary_326221.pdf
BOQ Comparative Chart
xlsx
finsummary_326221.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.55 MB
BOQ_326221.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .