Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.9 L+₹1.6 L (6.00%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹29.7 L+₹2.5 L (9.00%)Rejected-Finance 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹30.2 L+₹2.9 L (10.6%)Rejected-Finance NO 631 2 1ST FLOOR HAL ROAD VIBHUTIPURA NEAR JAMIAL MOSQUE BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹35.4 L+₹8.1 L (29.6%)Rejected-Finance 10 AISHWARYA 1ST FLOOR 2ND CROSS ANNAYAPPA GARDEN NEW THIPPASANDRA HAL HAL III STAGE BANGALORE 560075 | BENGALURU URBAN | KARNATAKA | 560075 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
25 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL BANGALORE
ASC CENTRE AND COLLEGE AGRAM POST BANGALORE 560007
WELCOME MAINTENANCE TO OFFICERS MD ACCN AT NGV KORAMANGALA AND VOC UNDER GE CENTRAL BANGALORE
2024_MES_651713_1
8371E
Open Tender
Civil Works - Others
Item Rate
270 days
GE CENTRAL BANGALORE
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE CENTRAL BANGALORE
₹74,000
10 Jul 2024
30 Apr 2024
27 May 2024
30 Apr 2024
25 May 2024
13 May 2024
30 Apr 2024 - 11 May 2024
Amount
B&R :Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etcand removal of entire debris as ordered outside MD land complete all as directed.
M&L for rendering 5 mm thick in CM 1:3 on brick work/stone work or concrete surface in ceiling finished the surface even and smooth without using extra cement complete all as specified.
M&L for rendering 10 mm thick in CM 1:6 on brick work/ block concrete surface on walls finished the surface even and smooth without using extra cement complete all as specified.
M&L preparing new plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of 1 to 2 mm thick Birla white cement based wall care putty complete all as specified.
All same as per item No. 4 here- in – above but as in ceiling -do-
M&L complete removal of existing any type of treatment of walls by rubbing, scrapping by hand held sander / long handle sander and finally Jet pressure washing to the entire satisfaction of Engineer-in-Charge and applying two coats of oil bound distemper by mechanical means / auto roller over a coat of 1-2 mm thick white cement based putty mixed with multi purpose mixer complete all as specified.
All same as per item No. 6 here- in – above but as in ceiling -do-
M&L Preparation of old surfaces of wall including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc by hand held sander / long handle sander including cornices, pilasters etc (Plastered or unplastered surfaces) and applying one coat of white wash complete all as directed.
All as per item No 8 here-in- above but two coat of white wash.
One coat of oil bound distemper over old decorated plastered / unplastered surface of walls including preparation of old decorated plastered surface all as specified and directed / as per manufacturer's instructions.
All same as per item No. 10 here- in – above but as in ceiling -do-
M&L preparation of old painted wooden surfaces exc 10 cm width or girth all as specified in SSR Part-I and applying one coat of Ist quality synthetic enamel paint, complete all as directed.
All same as per item No 12 here-in-above but one coat on steel suface
M & L for grinding of existing mosaic floor surface of any type or description with admixture as directed after complete removal of stain,greasy spots etc,washing with caustic soda and finally finished surface with wax polish by using machine complete all as specified and directed by Engr in charge. NOTE :- (i) The grinding & polishing work shall be carried out upto seventh and further floors including skirting, staircase treads & risers.(ii) Floor/rooms for grinding for polishing will be given in piece meal & not entire ordered qty in one go , it will be not be given in full at a time. The Bldg /floor wise shall be handed over for execution as and when required , It may be partly any number of times as for which contractor shall make necessay arrangements and no extra claim on this account will be admissible. (iii) The quoted rate is deemed to be inclusive for working in height upto 7th floor & above & no extra for the said conditions shall be entertained at later date.
M & L for cleaning of existing ceramic tiles in floor and wall using chemical / acid of suitable concentration asrecommended by the manufacturers so that the tiles are not damaged,filling of joints of tiles with white cement mixed with pigment to match with existing shade of tiles including at junctions of wall and floor,around gratings,door frames etc and finally cleaning with dry cloth the entire area including water supply/ sanitary fittings complete to the satisfaction of Eng-in charge.
E&M :Taking down copper/ aluminium point wiring(light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc complete.
Point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn in and including new heavy grade PVC rigid conduits 20mm or higher dia as reqd at site, fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated in & including suplly & fix new PVC board closed recessed, fixed on wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light /fan / bell point controlled by one switch
All same as per item No 17 here-in-above but for One 3 pin socket point 5 Amp on independent board -do-
All same as per item No 17 here-in-above but for One 3 pin socket point 5 Amp on same board with other switches
All as per item No. 17 above but with 4 sqmm ( Nominal area ) cable with 4 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed.
Point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn in and including new heavy grade PVC rigid conduits 20mm or higher dia as reqd at site, totally concealed in walls / floors / ceiling etc ; by means of saddles and clips etc; including all conduit accessories / fittings / junction boxes / inspection covers etc; of heavy grade, ISI marked and sunk terminal boxes factory made 16 SWG pressed steel housing, totally concealed in walls with 3 mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk/cup washers, for mounting of switches, sockets including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light /fan / bell point controlled by one switch
All same as per item No 21 here-in-above but for One 5 Aps switch two way -do -
All same as per item No 21 here-in-above but for One 3 pin socket point 5 Amp on independent board -do-
All same as per item No 21 here-in-above but for One 3 pin socket point 5 Amp on same board with other switches
All as per item No. 21 above but with 4 sqmm ( Nominal area ) cable with 4 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed.
All as per item No. 21 above but with 2.5 sqmm ( Nominal area ) cable with 2.5 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed.
Point Wiring with 1.5 Sqmm (Nominal Area) PVC insulated unsheathed 1100 Volts Grade Stranded Copper Conductor Cable (Red Colour Cable for Phase and Black Colour Cable for Neutral), laid in and including PVC Casing and Capping with Accessories (size of Casing and Capping as required at Site) including 1.50 Sqmm PVC ins-ulated Stranded Copper Conductor Cable (Green Colour) as Earth Continuity Conductor and connected to Common Earth Dolly or as directed and all accessories including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for One light / fan / bell controlled by one way switch.
All same as per item No 27 here-in-above but for One 3 pin socket point 5 Amp on independent board
All same as per item No 27 here-in-above but for One 3 pin socket point 5 Amp on same board with other switches.
All as per item No. 27 above but with 4 sqmm ( Nominal area ) cable with 4 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed.
Supply and fix modular switch 1 way 6A,1 module Make : Anchor/Havell/Polycab
Supply and fix modular switch 1 way 16A,1 module Make : Anchor/Havell/Polycab
Supply and fix socket, 6A-2/3 pin combined 2 modules Make : Anchor/Havell/Polycab
Supply and fix socket, 6A/16A-2/3 pin combined 2 modules Make : Anchor/Havell/Polycab
Supply and fix moduler fan Requlator, 120 W-2 modules
Supply and fix modular bell push 5 Amp
Supply and fix Ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC blocks. Make : Anchor/Havell/Polycab
Supply and fix in repair Switch piano, flush button single pole, 5 Amps one way. Make : Anchor/Havell/Polycab
Supply and fix in repair Switch sokcet combination flush type 5 Amp 2/3 pin muliti purpose Make : Anchor/Havell/Polycab
Supply and fix in repair Switch socket combination flush type 5/15 Amps 3/3 pin universal multipurpose Make : Anchor/Havell/Polycab
Supply and fix in repair Fan regulator electronic, step & socket type 230 volt, suitable for 1200/1400mm sweep ceiling fan. Make : Anchor/Havell/Polycab
Supply and fix in repairs modular switch 1 way 6A,1 module Make : Anchor/Havell/Polycab
Supply and fix in repairs modular switch 1 way 16A,1 module Make : Anchor/Havell/Polycab
Supply and fix in repairs socket, 6A-2/3 pin combined 2 modules Make : Anchor/Havell/Polycab
Supply and fix in repairs socket, 6A/16A-2/3 pin combined 2 modules Make : Anchor/Havell/Polycab
Supply and fix in repairs moduler fan Requlator, 120 W-2 modules
Supply and fix in repair modular bell push 5 Amp
Supply and fix in repair white cover plate with frame 2 modules complete Make model Glint or eqvalent model of Havells/Anchor
Supply and fix in repair white cover plate with frame 3 modules complete Make model Glint qr eqvalent model of Havells/Anchor
Supply and fix in repair white cover plate with frame 4 modules complete Make model Glint qr eqvalent model of Havells/Anchor
Supply and fix in repair white cover plate with frame 6 modules complete Make model Glint qr eqvalent model of Havells/Anchor
Supply and fix in repair white cover plate with frame 8 modules complete Make model Glint qr eqvalent model of Havells/Anchor
Supply and fix in repair white cover plate with frame 12 modules complete Make model Glint qr eqvalent model of Havells/Anchor
Supply and fix in repair Matel flush box 2 modules complete Make model Glint qr eqvalent model of Havells/Anchor
Supply and fix in repair Matel flush box 3 modules complete Make model Glint qr eqvalent model of Havells/Anchor
Supply and fix in repair Matel flush box 4 modules complete Make model Glint qr eqvalent model of Havells/Anchor
Supply and fix in repair Matel flush box 6 modules complete Make model Glint qr eqvalent model of Havells/Anchor
Supply and fix in repair Matel flush box 8 modules complete Make model Glint qr eqvalent model of Havells/Anchor
Supply and fix in repair Matel flush box 12 modules complete Make model Glint qr eqvalent model of Havells/Anchor
Supply and fix in repair Fan capacitor 2.5/3.15 mfd suitable for 1200/1400mm sweep ceiling fan. Make : Anchor/Havell/Polycab
Supply and fix in repair Door bell electronic, music type, 230 volt AC. Make : Anchor/Havell/Polycab
Taking down old un serviceable/serviceable light fittings of any type from wall all as directed by Engr in Charge
S&F in replacement LED tube light fitting of 10 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Shakti/Crompton Greaves/Bajaj
S&F in replacement LED tube light fitting of 20 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Shakti/Crompton Greaves/Bajaj
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board TPN, 415 volts, 4 way horizontal type double door type, 200 Amps rated neutral copper bus bar for housing MCB and fixed and tested on completion complete all as specified.
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 12 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
All as per item No 66 here-in before but SPN 8 ways DB.
Supply and fix in replacement MCB single pole 6 to 32 Amps 240 volts, C series, 10 kA rupturing capacity
Supply and fix in replacement MCB single pole & neutral 40 Amps 240 volts, C series,10 kA rupturing capacity
Supply and fix in replacement MCB Tripple pole & neutral 32 to 63 Amps 240 volts, C series,10 kA rupturing capacity providing in DB complete all as specified.
Supply and fix in repair 1.5 KW heating element as per exixting make or as ordred including rubber washers as per exising complete to the satisfaction of Engineer-in-charge..
All as per item No 71 here-in before but 2KW heating element -do-
Supply & fix in replacement PVC connection pipes 15mm dia for hot / cold water supply with brass adopters 600 mm long
Supply & fix thermostat for the geyser of 25 - 50 ltr capacities duly ISI Marked as per sample.
Supply & fix in repair exhaust fan sweep made of strudy Engineering plastic complete with louvers shutter , voltage 230 V , 50 Hz , 1200 RPM nioiseless , copper winding of sweep 200 mm with self closing louvers and blades complete fittings all as specified and directed . Make : Havells / Usha / Crompton
All as per item No 75 here-in-above but 150 mm sweep exhaust fan -do-
All as per item No 75 here-in-above but 250 mm sweep exhaust fan with metal body -do- (Note : Unservisable /defective Exhaust fan received from item Nos 75 to 77 shall be deposited to MES E&M Store without any extra cost to Govt).
Taking down old existing sub main wiring and provide new submain wiring with 2 runs of 4 Sqmm single core PVC insulated, unsheathed, multi stranded copper conductor and one single core 4 Sqmm PVC insulated , unsheathed , multi stranded copper cable as earthing lead as per IS : 694 / 1990 drawn through and including non-metallic PVC rigid conduit/casing caping of size as ordered in walls / ceilings etc with all accessories such as Tees, Elbows, junction box, reducers etc and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed. (Note :- 2 runs 4 Sqmm cable , one run 4 Sqmm cable and one run of PVC Conduit /Casing caping shall be measured as one unit length) .
All as per item No 78 here-in-above but 2 runs with 6 Sqmm single core cable and 6 Sqmm single core as earth contunity wire -do- . (Note :- 2 runs 6 Sqmm cable , one run 6 Sqmm cable and one run of PVC Conduit/Casing caping shall be measured as one unit length)
Chandana Enterprises
GKR and CO
M.Z.BUILDERS
VARALAKSHMI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .