Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹17,900
Closing Date
29 Mar 2022, 2:00 pmClosed
EXECUTIVE ENGINEER (EM) M 10
GREATER KAILASH, PART-I, NEW DELHI
Wiring / Electrification of newly constructed residential building of CEO(DJB) at Kilokari, Jal vihar site.
2022_DJB_219505_8
NIT No. 28/EE(EM)M-10/(21-22)
Open Tender
Electrical Work/ Equipment
Works
30 days
EXECUTIVE ENGINEER (EM) M 10
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹17,900
Yes
30 Mar 2022
24 Mar 2022
29 Mar 2022
24 Mar 2022
29 Mar 2022
24 Mar 2022
Wiring for light point / fan point / exhaust fan point / call bell point, with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. GROUP – C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit /submain wrining alongwith earth wire with the following sizes of FR PVC insulated copper conductor. single core cable in surface / recessed PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
Wiring for circuit /submain wrining alongwith earth wire with the following sizes of FR PVC insulated copper conductor. single core cable in surface / recessed PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
Wiring for circuit /submain wrining alongwith earth wire with the following sizes of FR PVC insulated copper conductor. single core cable in surface / recessed PVC conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire.
Wiring for circuit /submain wrining alongwith earth wire with the following sizes of FR PVC insulated copper conductor. single core cable in surface / recessed PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire.
Wiring for circuit /submain wrining alongwith earth wire with the following sizes of FR PVC insulated copper conductor. single core cable in surface / recessed PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. DSR 1.32
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. RJ-45 socket outlet
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing following pair 0.5 mm dia FRLS PV insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 4 Pair b.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in existing surface/ recessed Steel/ PVC conduit as required run of cable
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 440 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator).12 way, Double door.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole.
Supplying and fixing following rating, FOUR pole, 440 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 amps.
HYDROCON ENGINEERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .