| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹33.8 L+₹1.8 L (5.68%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹34.3 L+₹2.3 L (7.24%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹47.5 L+₹15.5 L (48.5%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹54.0 L+₹22.0 L (68.9%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹94,700
Closing Date
27 Jan 2021, 6:00 pmClosed
GE E/M BASE HOSPITAL DELHI CANTT
GE E/M BASE HOSPITAL DELHI CANTT-110010
REPAIR/ REPLACEMENT OF UNSV ITEMS FOR VOLTAGE STABILIZER, UPS, SENSOR DOOR, MOTORISED DOOR AND CONNECTED MISC E/M WORKS AT BASE HOSPITAL UNDER GE (E/M) BHDC-10
2020_MES_407441_1
GE/BH-68/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE E/M BASE HOSPITAL DELHI CANTT
Class D Category b(i)
7 documents required · 7 mandatory
₹500
Yes
GE E/M BASE HOSPITAL DELHI CANTT
₹94,700
Yes
6 Mar 2021
28 Dec 2020
29 Jan 2021
28 Dec 2020
27 Jan 2021
12 Jan 2021
Amount
M&L for comprehensive maintenance of Servo Voltage Stabilizer/ Servo Voltage Regulator, 50 KVA, comprising of following jobs complete all as specified and as directed:- (a) Free maintenance and repair of Normal accessories (Spare Parts), Servo Voltage Stabilizer/ Servo Voltage Regulator. (b) Dismantling and removing of defective voltage stabilizer, removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair of coils IC's, Regulators, Condensors, Triac, Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load. (c) Preventive maintenance of all systems on quarterly basis and upkeep of Report. (d) Attending all complaints within 24 working hours. Note:- (i) The rates quoted by the contractor shall deemed to be inclusive of T&P and minor sundries items etc as required. (ii) Major Spares Part shall be measured and paid for separately under respective item of this Schedule. These shall be identical to those specified by the original manufacturer. (iii) The job shall also includes shifting through crane with necessary accessories, transportation from site to work shop and vice- versa.
M&L for repair and rewinding 28 Amp dimmer including taking out old winding complete all as specified and as directed.
M&L for repair and rewinding buck/boost loading transformer capacity 70 Amp (each phase) including taking out old winding complete all as specified and as directed.
S&F in repair cut off circuit with contractor capacity 70 Amp TP complete all as specified and as directed.
S&F in replacement control wiring of Servo Voltage Stabilizer/ Servo Voltage Regulator, 50 KVA complete all as specified and as directed.
S&F in replacement Power wiring and copper thimble of Servo Voltage Stabilizer/ Servo Voltage Regulator, 50 KVA complete all as specified and as directed.
S&F in replacement Input/output connection capacity 100 Amp of Servo Voltage Stabilizer/ Servo Voltage Regulator, 50 KVA complete all as specified and as directed.
M&L for comprehensive maintenance of Servo Voltage Stabilizer/ Servo Voltage Regulator, 75 KVA, comprising of following jobs complete all as specified and as directed:- (a) Free maintenance and repair of Normal accessories (Spare Parts), Servo Voltage Stabilizer/ Servo Voltage Regulator. (b) Dismantling and removing of defective voltage stabilizer, removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair of coils IC's, Regulators, Condensors, Triac, Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load. (c) Preventive maintenance of all systems on quarterly basis and upkeep of Report. (d) Attending all complaints within 24 working hours. Note:- (i) The rates quoted by the contractor shall deemed to be inclusive of T&P and minor sundries items etc as required. (ii) Major Spares Part shall be measured and paid for separately under respective item of this Schedule. These shall be identical to those specified by the original manufacturer. (iii) The job shall also includes shifting through crane with necessary accessories, transportation from site to work shop and vice- versa.
M&L for repair and rewinding 40 Amp dimmer including taking out old winding complete all as specified and as directed.
M&L for repair and rewinding buck/boost loading transformer capacity 100 Amp (each phase) including taking out old winding complete all as specified and as directed.
S&F in repair cut off circuit with contractor capacity 110 Amp TP complete all as specified and as directed.
S&F in replacement control wiring of Servo Voltage Stabilizer/ Servo Voltage Regulator, 75 KVA complete all as specified and as directed.
S&F in replacement Power wiring and copper thimble of Servo Voltage Stabilizer/ Servo Voltage Regulator, 75 KVA complete all as specified and as directed.
S&F in replacement Input/output connection capacity 200 Amp of Servo Voltage Stabilizer/ Servo Voltage Regulator, 75 KVA complete all as specified and as directed.
M&L for comprehensive maintenance of Servo Voltage Stabilizer/ Servo Voltage Regulator, 100 KVA, comprising of following jobs complete all as specified and as directed:- (a) Free maintenance and repair of Normal accessories (Spare Parts), Servo Voltage Stabilizer/ Servo Voltage Regulator. (b) Dismantling and removing of defective voltage stabilizer, removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair of coils IC's, Regulators, Condensors, Triac, Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load. (c) Preventive maintenance of all systems on quarterly basis and upkeep of Report. (d) Attending all complaints within 24 working hours. Note:- (i) The rates quoted by the contractor shall deemed to be inclusive of T&P and minor sundries items etc as required. (ii) Major Spares Part shall be measured and paid for separately under respective item of this Schedule. These shall be identical to those specified by the original manufacturer. (iii) The job shall also includes shifting through crane with necessary accessories, transportation from site to work shop and vice- versa.
M&L for repair and rewinding 75 Amp dimmer including taking out old winding complete all as specified and as directed.
M&L for repair and rewinding buck/boost loading transformer capacity 140 Amp (each phase) including taking out old winding complete all as specified and as directed.
S&F in repair cut off circuit with contractor capacity 200 Amp TP complete all as specified and as directed.
S&F in replacement control wiring of Servo Voltage Stabilizer/ Servo Voltage Regulator, 75 KVA complete all as specified and as directed.
S&F in replacement Power wiring and copper thimble of Servo Voltage Stabilizer/ Servo Voltage Regulator, 100 KVA complete all as specified and as directed.
S&F in replacement Input/output connection capacity 200 Amp of Servo Voltage Stabilizer/ Servo Voltage Regulator, 100. KVA complete all as specified and as directed.
M&L for comprehensive maintenance of Servo Voltage Stabilizer/ Servo Voltage Regulator, 150 KVA, comprising of following jobs complete all as specified and as directed:- (a) Free maintenance and repair of Normal accessories (Spare Parts), Servo Voltage Stabilizer/ Servo Voltage Regulator. (b) Dismantling and removing of defective voltage stabilizer, removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair of coils IC's, Regulators, Condensors, Triac, Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load. (c) Preventive maintenance of all systems on quarterly basis and upkeep of Report. (d) Attending all complaints within 24 working hours. Note:- (i) The rates quoted by the contractor shall deemed to be inclusive of T&P and minor sundries items etc as required. (ii) Major Spares Part shall be measured and paid for separately under respective item of this Schedule. These shall be identical to those specified by the original manufacturer. (iii) The job shall also includes shifting through crane with necessary accessories, transportation from site to work shop and vice- versa.
M&L for repair and rewinding 120 Amp (60 X 2) dimmer including taking out old winding complete all as specified and as directed.
M&L for repair and rewinding buck/boost loading transformer capacity 200 Amp (each phase) including taking out old winding complete all as specified and as directed.
S&F in repair cut off circuit with contractor capacity 200 Amp TP complete all as specified and as directed.
S&F in replacement control wiring of Servo Voltage Stabilizer/ Servo Voltage Regulator, 150 KVA complete all as specified and as directed.
S&F in replacement Power wiring and copper thimble of Servo Voltage Stabilizer/ Servo Voltage Regulator, 150 KVA complete all as specified and as directed.
S&F in replacement Input/output connection capacity 200 Amp of Servo Voltage Stabilizer/ Servo Voltage Regulator, 150 KVA complete all as specified and as directed.
M&L for comprehensive maintenance of Servo Voltage Stabilizer/ Servo Voltage Regulator, 200 KVA, comprising of following jobs complete all as specified and as directed: - (a) Free maintenance and repair of Normal accessories (Spare Parts), Servo Voltage Stabilizer/ Servo Voltage Regulator. (b) Dismantling and removing of defective voltage stabilizer, removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair of coils IC's, Regulators, Condensors, Triac, Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load. (c) Preventive maintenance of all systems on quarterly basis and upkeep of Report. (d) Attending all complaints within 24 working hours. Note:- (i) The rates quoted by the contractor shall deemed to be inclusive of T&P and minor sundries items etc as required. (ii) Major Spares Part shall be measured and paid for separately under respective item of this Schedule. These shall be identical to those specified by the original manufacturer. (iii) The job shall also includes shifting through crane with necessary accessories, transportation from site to work shop and vice- versa.
M&L for repair and rewinding 150 Amp dimmer including taking out old winding complete all as specified and as directed.
M&L for repair and rewinding buck/boost loading transformer capacity 300 Amps (each phase) including taking out old winding complete all as specified and as directed.
S&F in repair cut off circuit with contractor capacity 300 Amp TP complete all as specified and as directed.
S&F in replacement control wiring of Servo Voltage Stabilizer/ Servo Voltage Regulator, 200 KVA complete all as specified and as directed.
S&F in replacement Power wiring and copper thimble of Servo Voltage Stabilizer/ Servo Voltage Regulator, 200 KVA complete all as specified and as directed.
S&F in replacement Input/output connection capacity 200 Amp of Servo Voltage Stabilizer/ Servo Voltage Regulator, 200 KVA complete all as specified and as directed.
M&L for comprehensive maintenance of Servo Voltage Stabilizer/ Servo Voltage Regulator, 250 KVA, comprising of following jobs complete all as specified and as directed:- (a) Free maintenance and repair of Normal accessories (Spare Parts), Servo Voltage Stabilizer/ Servo Voltage Regulator. (b) Dismantling and removing of defective voltage stabilizer, removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair of coils IC's, Regulators, Condensors, Triac, Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load. (c) Preventive maintenance of all systems on quarterly basis and upkeep of Report. (d) Attending all complaints within 24 working hours. Note:- (i) The rates quoted by the contractor shall deemed to be inclusive of T&P and minor sundries items etc as required. (ii) Major Spares Part shall be measured and paid for separately under respective item of this Schedule. These shall be identical to those specified by the original manufacturer. (iii) The job shall also includes shifting through crane with necessary accessories, transportation from site to work shop and vice- versa.
M&L for repair and rewinding 150 Amp dimmer including taking out old winding complete all as specified and as directed.
M&L for repair and rewinding buck/boost loading transformer capacity 350 Amp (each phase) including taking out old winding complete all as specified and as directed.
S&F in repair cut off circuit with contractor capacity 400 Amp TP complete all as specified and as directed.
S&F in replacement control wiring of Servo Voltage Stabilizer/ Servo Voltage Regulator, 250 KVA complete all as specified and as directed.
S&F in replacement Power wiring and copper thimble of Servo Voltage Stabilizer/ Servo Voltage Regulator, 250 KVA complete all as specified and as directed.
S&F in replacement Input/output connection capacity 200 Amp of Servo Voltage Stabilizer/ Servo Voltage Regulator, 250 KVA complete all as specified and as directed.
M&L for comprehensive maintenance of Servo Voltage Stabilizer/ Servo Voltage Regulator, 400 KVA, comprising of following jobs complete all as specified and as directed:- (a) Free maintenance and repair of Normal accessories (Spare Parts), Servo Voltage Stabilizer/ Servo Voltage Regulator. (b) Dismantling and removing of defective voltage stabilizer, removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair of coils IC's, Regulators, Condensors, Triac, Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load. (c) Preventive maintenance of all systems on quarterly basis and upkeep of Report. (d) Attending all complaints within 24 working hours. Note:- (i) The rates quoted by the contractor shall deemed to be inclusive of T&P and minor sundries items etc as required. (ii) Major Spares Part shall be measured and paid for separately under respective item of this Schedule. These shall be identical to those specified by the original manufacturer. (iii) The job shall also includes shifting through crane with necessary accessories, transportation from site to work shop and vice- versa.
M&L for repair and rewinding 300 Amp (150X2) dimmer including taking out old winding complete all as specified and as directed.
M&L for repair and rewinding buck/boost loading transformer capacity 550 Amp (each phase) including taking out old winding complete all as specified and as directed.
S&F in repair cut off circuit with contractor capacity 630 Amp TP complete all as specified and as directed.
S&F in replacement control wiring of Servo Voltage Stabilizer/ Servo Voltage Regulator, 400 KVA complete all as specified and as directed.
S&F in replacement Power wiring and copper thimble of Servo Voltage Stabilizer/ Servo Voltage Regulator, 400 KVA complete all as specified and as directed.
S&F in replacement Input/output connection capacity 200 Amp of Servo Voltage Stabilizer/ Servo Voltage Regulator, 400 KVA complete all as specified and as directed.
M&L for comprehensive maintenance of Servo Voltage Stabilizer/ Servo Voltage Regulator, 500 KVA, comprising of following jobs complete all as specified and as directed:- (a) Free maintenance and repair of Normal accessories (Spare Parts), Servo Voltage Stabilizer/ Servo Voltage Regulator. (b) Dismantling and removing of defective voltage stabilizer, removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair of coils IC's, Regulators, Condensors, Triac, Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load. (c) Preventive maintenance of all systems on quarterly basis and upkeep of Report. (d) Attending all complaints within 24 working hours. Note:- (i) The rates quoted by the contractor shall deemed to be inclusive of T&P and minor sundries items etc as required. (ii) Major Spares Part shall be measured and paid for separately under respective item of this Schedule. These shall be identical to those specified by the original manufacturer. (iii) The job shall also includes shifting through crane with necessary accessories, transportation from site to work shop and vice- versa.
M&L for repair and rewinding 400 Amp (200X2) dimmer including taking out old winding complete all as specified and as directed.
M&L for repair and rewinding buck/boost loading transformer capacity 700 Amp (each phase) including taking out old winding complete all as specified and as directed.
S&F in repair cut off circuit with contractor capacity 850 Amp TP complete all as specified and as directed.
S&F in replacement control wiring of Servo Voltage Stabilizer/ Servo Voltage Regulator, 500 KVA complete all as specified and as directed.
S&F in replacement Power wiring and copper thimble of Servo Voltage Stabilizer/ Servo Voltage Regulator, 500 KVA complete all as specified and as directed.
S&F in replacement Input/output connection capacity 200 Amp of Servo Voltage Stabilizer/ Servo Voltage Regulator, 500 KVA complete all as specified and as directed.
S&F in replacement electronic control card, suitable for 50 KVA to 500 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and as directed.
S&F in replacement Amp meter (Digital), suitable for 50 KVA to 500 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and as directed.
S&F in replacement Volt meter (Digital), suitable for 50 KVA to 500 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and as directed.
S&F in replacement Synchronus motor 10kg torque, suitable for 50 KVA to 500 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and as directed.
S&F in replacement RC network, suitable for 50 KVA to 500 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and as directed.
S&F in replacement DPDT switch, suitable for 50 KVA to 500 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and as directed.
S&F in replacement sensing transformer, (16V/1Amp, 12V/1 Amp), suitable for 50 KVA to 500 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and as directed.
S&F in replacement 12 pin connector (PCB), suitable for 50 KVA to 500 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and as directed.
S&F in replacement micro switch, 5 Amp, suitable for 50 KVA to 500 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and as directed.
S&F in replacement liver Nilon/Metal, suitable for 50 KVA to 500 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and as directed.
S&F in replacement gear assembly suitable size, suitable for 50 KVA to 500 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and as directed.
S&F in replacement potentiometer, suitable for 50 KVA to 500 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and as directed.
S&F in replacement push button switch for and high voltage, suitable for 50 KVA to 500 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and as directed.
M&L for painting of Servo Voltage Stabilizer any capacity, including cleaning the body surface of panel by rubbing with emery Paper to remove oil stains, dust etc and applying two coat of synthetic enamel paint by spray paint including writing SM No/MES No as per existing pattern complete all as specified and as directed.
Dismantling APFC panel, carefully removing the defective control device, MCCBs/MCBs, capacitor cum push button, switches, relays contacts, CTs, internal wiring etc, cleaning all parts by CRC solution/ emery paper as required and greasing the metallic and mechanical serviceable parts and reassembling complete panel complete all as specified and as directed.
S&F in replacement capacitor suitable for 10 KVAR on panel mounted type including disconnecting the incoming/outgoing cable connections and reconnecting with suitable copper lugs/ferrules etc after taking out the existing u/s and making good the disturbed surface complete all as specified and as directed.
All as per item No 74.00 here in before but Capacitor suitable for up to 05 KVAR Each complete all as specified and as directed.
S&F in replacement APFC Relay 6 stage on panel mounted type including disconnecting the incoming/outgoing cable connections and reconnecting with suitable copper lugs/ferrules etc including making good the disturbed surface complete all as specified and as directed.
All as per item No 76.00 here in before but APFC Relay 8 stage complete all as specified and as directed.
S&F in repair Contractor ML-3 Coil on panel mounted type including disconnecting the incoming/outgoing cable connections and reconnecting with suitable copper lugs/ferrules etc including making good the disturbed surface complete all as specified and as directed.
All as per item No 78.00 here in before but Contractor MNX, 40 A, 3 Pole complete all as specified and as directed.
All as per item No 78.00 here in before but Contractor MNX, 25 A, 3 Pole complete all as specified and as directed.
S&F in repair Indicating Light on APFC Panel complete all as specified and as directed.
M&L in replacement Control wiring in Existing APFC panel of any capacity complete all as specified and as directed.
Dehydration/ filtration of voltage stabilizer oil for voltage stabilizer of various capacities installed at different locations in base hospital by disconnecting plants electrically for recirculation existing voltage stabilizer oil with trolley mounted filtration plant till achieving dielectric strength 45 KV to 50 KV complete all as specified and as directed. Notes- (i) Oil shall be tested after filtration and test result shall be recorded before & after filtration of oil. (ii) Contractor shall make his own arrangement for oil filtration plant including transportation complete without any extra cost to Deptt. (iii) Transformer oil required for topping up shall measured and paid separately under respective item of this Schedule.
Supply & topping up oil for voltage stabilizer, up to required level, dielectric strength 50 KV & above all as per IS specification complete all as specified and as directed.
M&L for carrying out load balance distribution on LT side by checking the existing load on the feeder (3 Phase, 4 wire system) and accordingly shifting & connecting service cables to another phase conductor in accordance with balancing of Electric load complete all as specified & as directed. Note: Contractor shall submit reports before load balance and after load balance as per format given by the department.
M&L in repair pipe earthing (PIP) comprising of GI 80mm bore pipe, wall thickness of pipe 4.85 mm (Medium grade), 3.00 Metre length, terminal size 40x6mm & internal strip 25x4mm with one bag of BFC (50 Kg) as per IS 3043-1987, tubing filled with jelly earthing compound, duly inserted in soil, boring of 100mm bore filled with back filling compound including fibre chamber cover 1x1 feet, openable type, including testing of earthing complete all as specified and as directed. Note: On testing after completion, if the earth resistance < 1 Ohms is not obtain, earthing shall be rejuvenated at no extra cost till the desired earth resistance is obtained.
Dismantling following size cable, armoured/unarmoured, cutting burnt damaged portion of cable and replacement of lugs heavy duty Aluminium/copper and connecting in position including tightening cable gland, including necessary excavation/earth work complete all as specified and as directed:-
Cable of size 2 or 4 core, 16 Sqmm to 3.5 core 50 Sqmm
Cable of size 3.5 core 70 Sqmm to 3.5 core 95 Sqmm
Supply & laying in repair 630 Sqmm, single core, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium multistranded conductor, 1100 Volt grade, laid in trenches/ duct passing through pipe / duct or fixed on pole including connecting and testing etc, including taking down old cable complete all as specified & as directed.
Supply & laying in repair 240 Sqmm, 3.5 core, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium multistranded conductor, 1100 Volt grade, laid in trenches/ duct passing through pipe / duct or fixed on pole including connecting and testing etc, including taking down old cable complete all as specified & as directed.
S&F in repair Off load change over switch of 630 Amp capacity, 4 pole by pass switch along with MS Enclosure, made of 3.15 mm thick steel sheet Enclosure and extensible handle mounting stand made from 35 x 35 x 5mm thick MS channel, floor mounted and fixing in ground and necessary mounting accessories complete all as specified and directed. Make:- Havells Cat No IHCBFO0630 or equivalent model of Make mentioned in PS.
S&F in repair Off load change over switch of 400 Amp capacity, 4 pole by pass switch along with MS Enclosure, made of 3.15 mm thick steel sheet Enclosure and extensible handle mounting stand made from 35 x 35 x 5mm thick MS channel, floor mounted and fixing in ground and necessary mounting accessories complete all as specified and directed. Make:- Havells Cat No IHCBFO0400 or equivalent model of Make mentioned in PS.
S&F in repair Off load change over switch of 200 Amp capacity, 4 pole by pass switch along with MS Enclosure, made of 3.15 mm thick steel sheet Enclosure and extensible handle mounting stand made from 35 x 35 x 5mm thick MS channel, floor mounted and fixing in ground and necessary mounting accessories complete all as specified and directed. Make:- Havells Cat No IHCBFO0200 or equivalent model of Make mentioned in PS.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation/ fixing pole/ laying cable and pipe line etc or for man hole etc not exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick using excavated soil complete all as specified and as directed.
Removing excavated Soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for providing dry river sand as in sand cushioning to under ground electric cable including punning down of sand in layer complete all as specified and as directed. Note: For measurement & payment purpose, punned thickness of sand only shall be considered.
Supply and Laying burn brick size 225 mm X 113 mm X 75 mm, having minimum compressive strength 75 Kg/Sqm for cable covering complete all as specified and as directed.
S&F in repair/replacement MCCB 630 Amp, Three pole, 50 KA, Adjustable thermal & fixed magnetic setting ICS 75% of Icu, suitable for installation inside Panel including necessary addition, alteration to existing copper/ aluminium bus bar system complete all as specified and as directed. Make- Havells Model : IHLLNFBT0630 or equivalent model of Make mentioned in PS. Note:- Quoted rate shall be inclusive of required addition/ alteration in bus bar system.
S&F in repair/replacement MCCB 630 Amp, four pole, 50 KA, suitable for installation inside Panel, including necessary addition, alteration to existing copper /aluminium bus bar system complete all as specified and as directed. Make- Havells Model : IHLLNFBF0630 or equivalent model of Make mentioned in PS. Note:- Quoted rate shall be inclusive of required addition/ alteration in bus bar system.
S&F in repair/replacement MCCB 400 Amp, Three pole, 50 KA, Adjustable thermal & fixed magnetic setting ICS 75% of Icu, suitable for installation inside Panel including necessary addition, alteration to existing copper /aluminium bus bar system complete all as specified and as directed. Make- Havells Model : IHLLNFBT0400 or equivalent model of Make mentioned in PS. Note:- Quoted rate shall be inclusive of required addition/ alteration in bus bar system.
S&F in repair/replacement MCCB 400 Amp, four pole, 50 KA, suitable for installation inside Panel, including necessary addition, alteration to existing copper /aluminium bus bar system complete all as specified and as directed. Make- Havells Model : IHLLNFBF0400 or equivalent model of Make mentioned in PS. Note:- Quoted rate shall be inclusive of required addition/ alteration in bus bar system.
S&F in repair/replacement MCCB 320 Amp, four pole, 36 KA, suitable for installation inside Panel, including necessary addition, alteration to existing copper /aluminium bus bar system complete all as specified and as directed. Make- Havells Model : IHLLSEBF0320 or equivalent model of Make mentioned in PS. Note:- Quoted rate shall be inclusive of required addition/ alteration in bus bar system.
S&F in repair/replacement MCCB 250 Amp, four pole, 36 KA, suitable for installation inside Panel, including necessary addition, alteration to existing copper /aluminium bus bar system complete all as specified and as directed. Make- Havells Model : IHLLSEBF0250 or equivalent model of Make mentioned in PS. Note:- Quoted rate shall be inclusive of required addition/ alteration in bus bar system.
S&F in repair/replacement MCCB 200 Amp, four pole, 36 KA, suitable for installation inside Panel, including necessary addition, alteration to existing copper /aluminium bus bar system complete all as specified and as directed. Make- Havells Model : IHLLSEBF0200 or equivalent model of Make mentioned in PS. Note:- Quoted rate shall be inclusive of required addition/ alteration in bus bar system.
S&F in repair/replacement MCCB 160 Amp, four pole, 36 KA, suitable for installation inside Panel, including necessary addition, alteration to existing copper /aluminium bus bar system complete all as specified and as directed. Make- Havells Model : IHA13EBF0160 or equivalent model of Make mentioned in PS. Note:- Quoted rate shall be inclusive of required addition/ alteration in bus bar system.
S&F in repair 800Amp Fuse Switch units, fitted with sturdy side operating handle which drives the quick make break mechanism incorporating operating springs, Liberal sized silver plated terminals, suitable for aluminium cable/bus-bar termination, provided with terminal cover shields to prevent any accidental contact with live metal parts, Positive ON-OFF indication shall be provided on the switch door, Contacts made out of electrolytic copper, electro-plated with silver, for better contact and greater resistance to corrosion, Specially designed female contacts ensure low contact resistance and better arc-control, Fuse switches designed for use with HBC Cartridge fuse links conforming to IS:13703. The enclosure shall be made out of sheet steel, rust protected, phosphatised and powder coated, duly fitted with removable top and bottom end plates, provided with knock- outs for bus bars/cables entry, front accessible door, fitted with dust-excluding gasket, interlocked to prevent opening when the switch is in ‘ON’ condition, suitable for surface mounting complete all as specified and as directed. Make Havells Cat No - IHFNTW4800 or equivalent Model of Make Mentioned in PS.
S&F in repair 200Amp Fuse Switch units, fitted with sturdy side operating handle which drives the quick make break mechanism incorporating operating springs, Liberal sized silver plated terminals, suitable for aluminium cable/bus-bar termination, provided with terminal cover shields to prevent any accidental contact with live metal parts, Positive ON-OFF indication shall be provided on the switch door, Contacts made out of electrolytic copper, electro-plated with silver, for better contact and greater resistance to corrosion, Specially designed female contacts ensure low contact resistance and better arc-control, Fuse switches designed for use with HBC Cartridge fuse links conforming to IS:13703. The enclosure shall be made out of sheet steel, rust protected, phosphatised and powder coated, duly fitted with removable top and bottom end plates, provided with knock- outs for bus bars/cables entry, front accessible door, fitted with dust-excluding gasket, interlocked to prevent opening when the switch is in ‘ON’ condition, suitable for surface mounting complete all as specified and as directed. Make Havells Cat No - IHFNTW4200 or equivalent Model of Make Mentioned in PS.
S&F in repair 100Amp Fuse Switch units, fitted with sturdy side operating handle which drives the quick make break mechanism incorporating operating springs, Liberal sized silver plated terminals, suitable for aluminium cable/bus-bar termination, provided with terminal cover shields to prevent any accidental contact with live metal parts, Positive ON-OFF indication shall be provided on the switch door, Contacts made out of electrolytic copper, electro-plated with silver, for better contact and greater resistance to corrosion, Specially designed female contacts ensure low contact resistance and better arc-control, Fuse switches designed for use with HBC Cartridge fuse links conforming to IS:13703. The enclosure shall be made out of sheet steel, rust protected, phosphatised and powder coated, duly fitted with removable top and bottom end plates, provided with knock- outs for bus bars/cables entry, front accessible door, fitted with dust-excluding gasket, interlocked to prevent opening when the switch is in ‘ON’ condition, suitable for surface mounting complete all as specified and as directed. Make Havells Cat No - IHFNTW4100 or equivalent Model of Make Mentioned in PS.
M&L point wiring for modular switches or normal switches with 2X1.5 Sqmm, single core, multi stranded copper conductor PVC insulated unsheathed cable 1100 Volts grade, drawn through concealed rigid non-metallic PVC Conduit with all fittings of suitable size of dia as required at site including cadmium plated screws as per IS and replacement of 3 mm thick phenolic laminated sheet top covers on and including sunk type CI/ steel terminal boxes concealed in wall including 1.5 Sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for the following including taking down old point wiring complete all as specified and as directed.
One light/Fan point controlled by one switch.
One 3 Pin socket point, 5 Amps on the same board.
One 3 pin socket out let 5 Amps on the independent board
All as per item No. 109.00 here in before but point wiring using copper cable multi stranded 2x2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and as directed.
S&F in replacement Switch piano, flush type, single pole, one way 5 Amps complete all as specified and directed.
S&F in replacement Socket outlet 2 in 1, 3 pin 5 Amps complete all as specified and as directed.
S&F in replacement Switch socket combination 3 pin 16A, flush type complete all as specified and as directed.
M&L in replacement sub main wiring with 2 Run of 4 Sqmm, single core, multi stranded copper conductor FRLS PVC insulated and sheathed cable 1100 Volts grade, in and including 25 mm, medium grade PVC conduit recessed in walls and on surface at RCC portions etc including 4 Sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly including drilling holes and making good to disturbed surface complete all as specified and as directed. (Note: Two run of copper cable with one run of Earth wire along with 25mm PVC conduit shall be measured as one RM length.)
M&L in replacement sub main wiring with 2 Run of 6 Sqmm, single core, multi stranded copper conductor FRLS PVC insulated and sheathed cable 1100 Volts grade, in and including 25 mm, medium grade PVC conduit recessed in walls and on surface at RCC portions etc including 6 Sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly including drilling holes and making good to disturbed surface complete all as specified and as directed. (Note: Two run of copper cable with one run of Earth wire along with 25mm PVC conduit shall be measured as one RM length.)
S&F in repair sheet metal enclosure, MCB DB, TPN, Double Door, 4 way, 415V complete all as specified and as directed.
S & F in replacement MCB, TPN, 240 Volts, 63 Amps complete all as specified and as directed.
S & F in replacement MCB, SPN, 240 Volts, 6 to 32 Amps complete all as specified and as directed.
S & F in replacement MCB, SP, 240 Volts, 6 to 32 Amps complete all as specified and as directed.
S&F in repair Power saving LED Colour changing Batten light fitting, 20/22 Watt, 4 feet (Approx), 230 Volts, turn off and on in 5 second to change colour complete all as specified and as directed.
M&L for comprehensive maintenance of 02 Nos Motorized door, detailed as under complete all as specified and directed: - (i) Free maintenance and repair of Normal accessories (Spare Parts) for 02 Nos Doors. (ii) Preventive maintenance of all systems on quarterly basis. (iii) Attending all complaints within 24 Hours of complaint intimated by JE-in-Charge. (iv) Field service report shall be maintained and submitted to the JE-in-Charge after expiry of every quarter. Note:- (a) The rates quoted by the contractor shall deemed to be inclusive of T&P etc (b) Major Spares Parts shall be measured and paid separately under respective item of this Schedule. (c) A penalty of Rs 500.00 per complaint per day shall be imposed on contractor, if the complaint shall not attended within 24 Hours of complaint intimated by JE-in-Charge.
S&F in repair AC, single phase, 230 V, induction motor for motorized door, of carrying capacity 1600 kg, to carry the load with safety sensor limit switches, to ensure end stationing of the gate to safeguard over travelling and over loading of drives, controlling through remote and other connecting accessories and guide bar complete all as specified and as directed.
M&L for comprehensive maintenance of 05 Nos sensor door, detailed as under complete all as specified and directed:- (i) Free maintenance and repair of Normal accessories (Spare Parts) for 05 Nos Doors. (ii) Preventive maintenance of all systems on quarterly basis and upkeep of log book. (iii) Attending all complaints within 24 working hours intimated by JE-in-Charge. (iv) Field service report shall be maintained and submitted to the JE-in-Charge after expiry of every quarter. Note:- (a) The rates quoted by the contractor shall deemed to be inclusive of T&P etc (b) Major Spares Part shall be measured and paid for separately under respective item of this Schedule as supply only. (c) A penalty of Rs 500.00 per complaint per day shall be imposed on contractor, if the complaint shall not attended within 24 Hours of complaint intimated by JE-in-Charge.
Supply only Dorma Anti Jump Wheel suitable for sensor door complete all as specified and as directed.
Supply only Dorma Main Roller suitable for sensor door complete all as specified and as directed.
Supply only Radar suitable for sensor door complete all as specified and as directed.
Supply only Motor Assembly suitable for sensor door complete all as specified and as directed.
Supply only Control Unit Assembly suitable for sensor door complete all as specified and as directed.
Supply only Torroidal Transformer suitable for sensor door complete all as specified and as directed.
Supply only Timer Belt with Accessories suitable for sensor door complete all as specified and as directed.
Dismantling and refixing Sensor Door installation, including Hand Sensor Fitting, wiring and door service, including cleaning and adjustment of door alignment complete all as specified and as directed.
Supply, fixing, commissioning and testing in repair 1 KVA, On line UPS System, 1 Phase Input & 1 phase output, complete with built in battery, interconnecting cable, with minimum 15 minute backup, including stand complete all as specified and as directed.
S&F in repair HT Adapter Panel (11 KV), 11 KV earthing truck, with Suitable size bus bar, with 11 KV VCB, Trolley connected with Existing OCB/ VCB in same size, as existing complete all as specified and as directed.
Outsource of services for electric meter reading and preparation/distribuion of bills on monthly bases, preparation of reports, maintenance and up-keeping of office records and other official works related to trade including connected services for following areas under GE (E/M) Base Hospital Delhi Cantt-10 complete all as specified and as directed: - (i) MH Line JCOs/ ORs Qtrs - 159 Nos (ii) Base Hospital Offrs Qtrs - 06 Nos (iii) Private parties - 29 Nos (iv) Army Medical College & Hostel - 02 Nos (v) Artrac Guest Room - 04 Nos (vi) Army Boys Hostel - 03 Nos Notes:- (a) Meter reader shall be 10+2 qualified and having experience of all type of meter reading, preparation and submission of monthly electricity bills in standard and approved format as provided by Engr-in-Charge. (b) Complete Job of meter reading and Preparation/Distributionof bills & reports including up keeping of office records shall be completed by th rep of contractor by 25th day of Each month,failing which a penalityofRs 1000/- per day shall be imposed on contractor. (c) Contractor shall submitted meter reading and consumption as per format provided by Engr-in-Charge. (d) In case of any meter found derector/ tampered, same shall be intimated to in charge BSO Sub Divn and AGE E/M BHDC. (e) Meter reading report shall be submitted in duplicate. (f) Meter reader shall obtain the signature of occupant on meter reading card with date while noting down the reading. (g) Cost of Stationery & forms required for meter reading & related reports shall deemed to be included in rates quoted by the contractor. (h) Complete Job of meter reading and preparation/distribution of Bills & reports including upkeeping of office records shall be compared by the rep of contractor by 25th day of each month, failing which a penalty of Rs 1000/- per day shall be imposed on contractor.
Saini Enterprises
Vishal Traders
M/s Adhikari construction co.
Harsh India Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .