Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹8.4 Cr
EMD Value
₹16.8 L
Closing Date
2 Dec 2026, 11:30 am
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER
14 conditions · 2 needing a document upload
10.2.The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where. V=Advertised value of the tender in crores of Rupees. N=Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turn over. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported byAudited Balance Sheet.
Technical Eligibility Criteria: (a) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. b(1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b) (ii) In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows. The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway. In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as
Defination of Similar Work :- Execution of Panel Interlocking or ElectronicInterlocking with MACLS either Indoor orOutdoor works or Both.ORAlteration to Existing Panel Interlocking/Electronic Interlocking with MACLS either Indooror Outdoor works or Both.ORProvision of IBS works in panel Interlocking andElectronic Interlocking sections.ORProvision of Automatic signalling with Axlecounter/Track circuits or both together.ORProvision of UFSBI/BPACs/Digital Axlecounters at Panel Interlocking stations/ElectronicInterlocking stations.ORZonal Signalling/Telecom works Indoor orOutdoor works or both.
7 conditions · 5 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer has to go through the Technical Specifications as stipulated in Annexure - XIX of the Tender Document and comply.
As per GCC Clause 14.0 Documents to be SubmittedAlongwithtender. (i)The tenderer shallclearly specify whetherthetender issubmitted on his own (Proprietary Firm) or onbehalfofaPartnership Firm / Company / Joint Venture (JV) /RegisteredSociety/ Registered Trust /Hindu Undivided Family(HUF)/Limited LiabilityPartnership (LLP) etc. Thetenderer(s)shallenclose the attestedcopies of the Constitution oftheir concern,and copy of PANCardalong with their tender.Tender Documentsin such cases are to besigned by suchpersonsas may be legallycompetent to sign themon behalf of the firm,company,association,trust or society, as thecase may be.
i) Following documents shall be submitted by the tenderer: (a)SoleProprietorship Firm: (i) Alldocuments in terms of Para10oftheTender Form (Second Sheet) above. HUF: (ii)Acopyofnotarizedaffidavit on Stamp Paper declaring that he whoissubmitting thetender on behalfof HUF is in the positionof'Karta' of HinduUndivided Family (HUF) and he hastheauthority,power andconsent given by other members to acton behalf ofHUF. (iii)Allotherdocuments in terms of Para 10 ofthe TenderForm (SecondSheet) above. (c) Partnership Firm: (i)Alldocuments as mentionedin para18 of the Tender Form(SecondSheet). (d) Joint Venture(JV):All documents as mentionedin para17 of the Tender Form (SecondSheet). (e)companyregisteredunder Companies Act 2013: (i)Thecopies ofMOA(Memorandumof Association) /AOA (Articles ofAssociation)of the company(ii)A copy of Certificate ofIncorporation (iii)AcopyofAuthorization/Power of Attorney issuedby theCompany(backedby the resolution of Board ofDirectors) infavourof the individualto sign the tender on behalf of the companyandcreateliabilityagainst the company. (iv)All other documentsinterms Para 10 ofthe Tender Form(Second Sheet) above. (f)LPLimited LiabilityPartnership): If the tender is submittedonbehalfof a LLPregistered under LLP Act-2008, the tenderershall submitalongwith the tender:(v)A copy of LLP Agreement(vi) A copyofCertificate of Incorporation (vii)A copyofPowerofAttorney/Authorization issued by the LLP in favour oftheindividualto sign the tenderon behalf of the LLP andcreateliability againstthe LLP. (viii)An undertaking by allpartnersofthe LLP that they arenot blacklisted or debarred byRailways orany other Ministry/Department of the Govt. of Indiafromparticipation in tenders /contracts as on the dateofsubmissionof bids, either in theirindividual capacity or in anyfirm/LLP or JVin which they were/ arepartners/ members.Concealment/wrong information in regard toabove shall makethecontractliable for determination underClause 62 of theStandard GeneralConditions ofContract. (ix)Allother documentsin terms ofPara10 of the Tender Form (SecondSheet). (g)Registered Society&Registered Trust: The tenderershallsubmit: (x)A copy of theCertificateof Registration (xi) A copyofMemorandum ofAssociation of Society/Trust Deed (xii) AcopyofPower ofAttorney in favour of the individual to sign thetenderdocumentsand create liabilityagainst the Society/Trust. (xiii)Acopy of Rules& Regulations of the Society. (xiv)Allotherdocuments in termsof Para 10 of the Tender Form(Second Sheet)above (iii) If it isNOT mentioned in the submittedtender thattender is beingsubmitted on behalf of aSoleproprietorship firm /Partnershipfirm / Joint Venture /Registered Company etc., thenthetendershall be treated ashaving.
15. The tenderer whether sole proprietor / acompanyorapartnership firm / joint venture (JV) /registeredsociety/registered trust / HUF / LLP etc if they want toactthroughagentor individual partner(s), should submit alongwiththetender, acopy of power of attorney dulystampedandauthenticated by aNotary Public or by Magistrate infavour ofthespecific personwhether he/they be partner(s) of thefirm oranyother person,specifically authorizing him/them tosignthetender, submit thetender and further to deal withtheTender/Contract up to thestage of signing the agreementexceptin casewhere suchspecific person is authorized forabovepurposesthrough aprovision made in the partnership deed/MemorandumofUnderstanding / Article ofAssociation/Boardresolution,failingwhich tender shall besummarily rejected. Aseparatepower ofattorney duly stampedand authenticated by aNotaryPublic orby Magistrate in favour ofthe specific personwhetherhe/theybe partner(s) of the firm orany other person,shall besubmittedafter award of work,specifically authorizinghim/themto dealwith all other contractualactivities subsequentto signingofagreement, if required. Note: APower of Attorneyexecutedandissued overseas, the documentwill also have to belegalizedbythe Indian Embassy and notarizedin the jurisdictionwherethePower of Attorney is being issued.However, thePowerofAttorney provided by Bidders fromcountries thathavesignedthe Hague Legislation Convention 1961are notrequiredto belegalized by the Indian Embassy if itcarriesaconformingApostille certificate.
As per GCC Clause No.18.10 The tenderer shallclearlyspecifythatthe tender is submitted on behalf of apartnershipfirm.Thefollowing documents shall be submitted bythepartnershipfirm,with the tender: (i) A notarized copyofpartnership deed oracopy of the Partnership deedregisteredwith the Registrar.. (i)Anotarized or registered copy ofPower ofAttorney(dulyregistered as per prevailing law) in favourof theindividualtotender for the work, sign the agreement etc.andcreateliabilityagainst the firm. (ii) An undertaking byallpartners ofthepartnership firm that they are not blacklistedordebarredbyRailways or any other Ministry/Department oftheGovt. ofIndiafrom participation in tenders / contracts as onthedateofsubmission of bids, either in their individual capacityorinanyfirm/LLP in which they were /arepartners/members.AnyConcealment / wrong informationinregard to above shallmakethe bid ineligible or the contractshallbe determinedunderClause 62 of the StandardGeneralConditions of Contract.
As per GCC 2022): The tenderers shall submit a copyofcertificatestating that all theirstatements/ documentssubmittedalong withbid are true and factual. Standard formatofcertificateto besubmitted by the bidder is enclosed asAnnexure-V(Annexure-V of GCC April2022). Non submission ofabovecertificate by the biddershall result in summarilyrejectionofhis/their bid (Clause 6.1 ofGCC2022 PART-I) ( Click here to download Format)
Hyderabad Division: SC-DHNE Section - 1) (UP&DN) - Re-alignment of Curves - 7 Nos., 2) TTR (TWS+WCMSC - 45 Sets, TWSEJ - 67 Sets, 3) MBNR-DHNE Section - (Sr.DEN/LINES/HYB): Provision of safety fencing/boundary wall of along the track for speed 130 Kmph and above using NHAI anti-crash barrier/W-beam steel fencing for 115 Km fencing length (Phase-I), 4) Standardization of cutting in DEN/South/HYB section, 5) CTR(P) 34.60 Km & 6) CTR(P) - 38.10 Km - S&T arrangements.
Y-SG-36-2026-27-26~SCR
Y-SG-36-2026-27-26
Open
Works - General
12 Months
Hyderabad, Telangana
₹0
₹16.8 L
9 Nov 2026
9 Nov 2026
18 Nov 2026
189 items across 7 schedules · ₹8,38,44,350.68 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of CLS Post 140mm Dia to Specn IRS:S 6-81 Rev.3 or latest, 4.5 Meters long (Inspection: RITES). | Numbers | 16.00 | 4,710 | 75,360 |
| 2 | Supply of CLS Ladder set complete with staging-platform, supports, cast iron ladder base/Shoe - Ladder for 4.5m post (Inspection: RITES). | Set | 16.00 | 6,432 | 1,02,912 |
| 3 | Supply of Surface Base 140mm Dia CLS post as per Drg No. S 2011-M (Inspection: RITES). | Numbers | 16.00 | 3,476 | 55,616 |
| 4 | Supply of 2 aspect Metallic (MS) colour light Signal Unit complete as per Drg No. SA.23003/AIM (Adv.) with latest amendment and specification IRS: 5 26-64 or latest (Inspection: RITES). | Numbers | 6.00 | 12,998 | 77,988 |
| 5 | Supply of 3 Aspect Metallic (MS) Colour Light Signal Unit complete as per Drg No. SA.23002/A/M latest Amdt. andSpecn IRS: S 26-64 or latest (Inspection: RITES). | Numbers | 10.00 | 17,623 | 1,76,230 |
| 6 | Supply of Metallic (MS) Colour Light Signal Unit-4 aspect complete as per Drg No. SA.23001/A/M (Adv.) with latest Amdt. andSpecn IRS: S 26-64 or latest (Inspection: RITES). | Numbers | 2.00 | 18,820 | 37,640 |
| 7 | Supply of Calling On Signal Unit complete with U Bolts as per RDSO Drg No. SA.24351 (Adv.) or latest (Inspection: RITES). | Numbers | 6.00 | 4,740 | 28,440 |
| 8 | Supply of Ground type Position Light Shunt Signal complete with base, pipe, arrow mark and hoods as per RDSO Drg No. SA 23840 or latest (Inspection: RITES). | Numbers | 4.00 | 6,083 | 24,332 |
| 9 | Supply of Post type Position Light Shunt Signal with hoods, arrow mark and offset bracket to suit 90mm Sockets (CLS) with two numbers of 'U' bolts and nuts complete to fix Shunt Signal below main Stop Signal as per RDSO Drg No. SA 23840 or latest (Inspection: RITES). | Numbers | 4.00 | 3,502 | 14,008 |
| 10 | Supply of One way Junction type Direction type route indicator as per Specn IRS:S 66- 84 Amd.1 or latest as per Drg No. SA 23401 (Inspection: RITES). | Numbers | 1.00 | 15,187 | 15,187 |
| 11 | Supply of Junction type/Direction type Route Indicator as per Specn IRS:S 66-84 Amd.1 or latest - Two way as per Drg No. SA 23402 (Inspection: RITES). | Numbers | 2.00 | 20,490 | 40,980 |
| 12 | Supply of Vitreous Enamel Coated Board of 230mm Dia (A, P, G, C, IB Markers) made of 2mm thick sheet as per following colour scheme: 1) 'G' Marker - Yellow background, black letters &2) Other boards - White background, black letters (Inspection: Consignee). | Numbers | 20.00 | 267 | 5,340 |
| 13 | Supply of 280mmx102mmx2mm thickness Vitreous Enamel Coating Arrow Markers Board fabricated with MS Clamp of size 40mmx6mm along with suitable bolts and nuts (Inspection: Consignee). | Numbers | 4.00 | 370 | 1,480 |
| 14 | Supply of 'E' type Lock of specified ward as per requirement with one key 'E' type Lock to Drg No. SA3376-M or latest and Specn IRS: S30-64 or latest (Inspection: RDSO). | Numbers | 40.00 | 1,051 | 42,040 |
| 15 | Supply of Relay fixing Frame for Full Location Box. The Frame shall be of approximate size 940mmx150mm and made with powder coated MS angle of 25mmx25mmx3mm. The Frame shall have suitable holes to fix in Full Location Box (Inspection: Consignee). | Numbers | 40.00 | 853 | 34,120 |
| 16 | Supply of Hylam sheet of size 2400mmx1200mmx6mm, resin bonded, grade P3 as per IS Specn IS 2036 of 1974 or latest (Inspection: Consignee). | Numbers | 2.00 | 7,124 | 14,248 |
| 17 | Supply of Hylam sheet of size 2400mmx600mmx6mm, resin bonded, grade P3 as per IS Specn IS 2036 of 1974 or latest (Inspection: Consignee). | Numbers | 2.00 | 3,430 | 6,860 |
| 18 | Supply of Hylam sheet of size 2400mmx600mmx3mm, resin bonded, grade P3 as per IS Specn IS:2036 of 1974 or latest (Inspection: Consignee). | Numbers | 2.00 | 1,888 | 3,776 |
| 19 | Supply of Ground connection insulations for thick web switch layout facing point (BG) for 52 Kgs/60 Kgs rail fitted with high thrust Point Machine comprising of the following:1. Bush as per Drg No. S3463-1 No. and Washer as per Drg No. S8640- 2 No. for drive (throw) rod.2. Bush as per Drg No. S 23199-1 No. and Washer as per Drg No. S 8640 - 2 No. for short detector rod.3. Bush as per Drg No. S 23199-1 No. and Washer as per Drg No. S 8640 - 2 No. for long detector rod.4. Bush as per Drg No. S 22179-1 No. and Washer as per Drg No. S 8640 - 2 No. for short lock rod.5. Bush as per Drg No. S 22179-1 No. and Washer as per Drg No. S 8640 - 2 No. for long lock rod.6. Bush 'B' as per Drg No. S 8912 for LH lock slide-1 No.7. Bush 'B' as per Drg No. S 8912 for LH lock arm-2 No.8. Bush 'B' as per Drg No. S 8912 for RH lock arm -2 No.9. Bush 'B' as per Drg No. S 8912 for RH lock slide-1 No.10. Bush as per Drg No. S 23199 -4 No. and washer as per Drg No. S 8640 - 4 No. for LH lock slide.11. Insulating Plate LH as per Drg No. S 3404 RDSO/S 3593- 1 No.12. Insulating Plate RH as per Drg No. S 3404 RDSO/S 3592- 1 No.13. Bush as per Drg No. S 23199-4 No. and washer as per Drg No. S 8640-4 No. for RH lock slide. (Inspection: Consignee). | Set | 100.00 | 1,074 | 1,07,400 |
| 20 | Supply of Track Feed Battery Charger to work on 110V AC for charging 1 or 2 or 3 or 4 Lead Acid Cell of 80AH (10 Amps) used in Track Circuit as per RDSO Specn No. IRS.S.89/2013 Ver 1.0 latest (Inspection: RDSO). | Numbers | 20.00 | 8,294 | 1,65,880 |
| 21 | Supply of Track Lead Junction Boxes Fibre Glass as per Drg No. CWM-00597 of FRP material to and Specn IRS:S 23 along with fixtures i.e., one MS angle 50mmx50mmx5mm, 0.9m long, two numbers of GI pipes of 25mm Dia, 500mm long along with nuts and bolts and 500mm long (grommet bushes, 60mm ARA Terminals-2 Nos.) (Inspection: Consignee). | Numbers | 290.00 | 1,546 | 4,48,340 |
| 22 | Supply of Galvanised Wire Rope 6/19 steel, 6mm Dia with fibre core as per Specn IS 3459/2004 or latest (Inspection: Consignee). | Metre | 2500.00 | 80 | 2,00,000 |
| 23 | Supply of 'B' type Chokes to as per Specn IRS: S65-83 Amd.1 or latest (Inspection: RDSO). | Numbers | 40.00 | 2,313 | 92,520 |
| 24 | Supply of Stationary Low Maintenance Secondary Lead Acid Cells - 2V, 80AH as per RDSO Specn IRS: S88-2004 or latest. This includes supply of inter cell connectors, bolts, nuts, acid level indicating floats and vent plugs (Inspection: RDSO). | Numbers | 80.00 | 3,315 | 2,65,200 |
| 25 | Supply of Hydro Meter as per IS: 3104 (Part II)-1982 or latest (Inspection: Consignee). | Numbers | 20.00 | 277 | 5,540 |
| 26 | Supply of Distilled Water for topping of Secondary Cells as per Specn IS 1106 or latest (Inspection: Consignee). | Litre | 200.00 | 10 | 2,000 |
| 27 | Supply of Porcelain Insulators for Secondary Lead Acid Cells (Inspection: Consignee). | Numbers | 150.00 | 30 | 4,500 |
| 28 | Supply of Titanium Coated 7.2 mm drill bits of Make: Bosch/Addision or better (Inspection: Consignee). | Numbers | 150.00 | 146 | 21,900 |
| 29 | Supply of Channel Bond Pins 7mm Dia single groove as per Specn IRS: S 17-75 Amd.1 or latest (Inspection: Consignee). | Numbers | 300.00 | 3 | 900 |
| 30 | Supply of Track Feed Regulating Resistance disk type 0 to 30 as per Drg No. SA 20161 66-M or latest. To be procured from RDSO approved firms (Inspection: RDSO). | Numbers | 100.00 | 358 | 35,800 |
| 31 | Supply of Plug-in type miniature tractive armature Non-AC immune, DC neutral line relay complete with plug board, retaining clip/ATC Clip and connectors as per Specn BRS 930, IRS:S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QN1-8F/8B, 24V DC. The interlocking code: ABCDF (Inspection: RDSO). | Numbers | 30.00 | 4,400 | 1,32,000 |
| 32 | Supply of Plug-in type miniature tractive armature Non-AC immune, DC neutral line relay complete with plug board, retaining clip/ATC Clip and connectors as per Specn BRS 930, IRS:S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QN1- 12F/4B, 24V DC. The interlocking code: ABCDE (Inspection: RDSO). | Numbers | 30.00 | 4,283 | 1,28,490 |
| 33 | Supply of 24V DC plug-in type miniature tractive armature, AC immune relay complete with plug board, retaining clip/ATC Clip and connectors as per IRS: S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 60-78 Amd.1 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QBCA1 - 2HF/4B, Interlocking Code: BCEJK as per Specn BRS 943 or latest (Inspection: RDSO). | Numbers | 25.00 | 8,307 | 2,07,675 |
| 34 | Supply of 24V DC plug-in type miniature tractive armature, AC immune relay complete with plug board, retaining clip/ATC Clip and connectors as per IRS: S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 60-78 Amd.1 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QNA1- 8F/8B, Interlocking Code: ABDGH as per Specn BRS 931 A or latest (Inspection: RDSO). | Numbers | 50.00 | 4,738 | 2,36,900 |
| 35 | Supply of 24V DC plug-in type miniature tractive armature, AC immune relay complete with plug board, retaining clip/ATC Clip and connectors as per IRS: S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 60-78 Amd.1 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QNA1-12F/4B, DC Neutral Line Relay, Interlocking Code: ABDFH as per Specn BRS 931 A or latest (Inspection: RDSO). | Numbers | 20.00 | 4,413 | 88,260 |
| 36 | Supply of 24V DC plug-in type miniature tractive armature, AC immune Relay complete with plug board, retaining clip/ATC Clip and connectors as per IRS: S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 60-78 Amd.1 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QNA1 K-6F/6B, Interlocking Code: CDEKY as per Specn BRS 931A or latest and RDSO letter No. STS-E-Relays-UEA (P1), dt.30.05.1997 (Annexure-Il) (Inspection: RDSO). | Numbers | 30.00 | 5,062 | 1,51,860 |
| 37 | Supply of 24V DC plug-in type miniature tractive armature, AC immune relay complete with plug board, retaining clip/ATC Clip and connectors as per IRS: S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 60-78 Amd.1 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QSPA1 - 8F/4B, The interlocking code: ABDEJ, Specn BRS 933A or latest (Inspection: RDSO). | Numbers | 30.00 | 6,465 | 1,93,950 |
| 38 | Supply of AC immune, plug-in type, Style 'QTA2', 2F/1B DC Neutral Track Relay for Rly Signalling Track Circuits with coil resistance 9 ohm, complete with plug board, retaining clip and connectors as per Specns: BRS 939A & 966 or latest, IRS:S 23- 88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) with interlocking code FGHKX (Inspection: RDSO). | Numbers | 30.00 | 4,806 | 1,44,180 |
| 39 | Supply of ECR 4E-4B' for 110V AC lit LED Signals, complete with plug board, retaining clip and connectors as per RDSO Specn No. STS-E-Relays-AC Lit LED Signal- 09-2002 Amd.1 or latest, BRS 941A, IRS: S 23-88 Amd.1 or latest, IRS: S34-68 Amd.6 or latest, IRS: S 67-85 Amd.3 or latest (as applicable). The interlocking code for this unit shall be ABDHK (with ATC clips) (Inspection: RDSO). | Numbers | 30.00 | 5,841 | 1,75,230 |
| 40 | Supply of Failsafe Electronic Flasher Device 24V DC, 3A as per RDSO Specn RDSO/SPN/173/2002 Amd.2 or latest (Inspection: RDSO). | Numbers | 4.00 | 4,349 | 17,396 |
| 41 | Supply of Fail-Safe Electronic Time Delay Device mounted on Q series relay band enclosed within Q series relay cover complete with plug board, retaining clip and connectors as per Specns No. IRS: 61- 2000 Amd.3 or latest, IRS: 323-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest IRS 67- 85 (as applicable). The device shall work on 24V DC and shall give 24V DC output after the specified time delay - Time delay of 30 seconds. Interlocking code: AFLKY (Inspection: RDSO). | Numbers | 6.00 | 2,544 | 15,264 |
| 42 | Supply of Fail-Safe Electronic Time Delay Device mounted on Q series relay band enclosed within Q series relay cover complete with plug board, retaining clip and connectors as per Specns No. IRS: 61- 2000 Amd.3 or latest, IRS: S23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest IRS 67- 85 (as applicable). The device shall work on 24V DC and shall give 24V DC output after the specified time delay - Time delay of 60 seconds. Interlocking code: AFHKY (Inspection: RDSO). | Numbers | 4.00 | 2,544 | 10,176 |
| 43 | Supply of Fail-Safe Electronic Time Delay Device mounted on Q series relay band enclosed within Q series relay cover complete with plug board, retaining clip and connectors as per Specn No. IRS: 61- 2000 Amd.3 or latest, IRS: S23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest IRS 67- 85 (as applicable). The device shall work on 24V DC and shall give 24V DC output after the specified time delay - Time delay of 120 seconds. Interlocking code: AFGKY (Inspection: RDSO). | Numbers | 6.00 | 2,332 | 13,992 |
| 44 | Supply of Terminal Block: 1 way Poly butylene Terephthalate (PBT) of size 60mm (link centre to centre) as per RDSO Drg No. SA23745/Alt.5 or latest, SA23746-Alt.5 or latest, S23747-Alt.5 and Specns IRS: S 75- 2006 Rev.2.0 (Tentative) or latest, IRS: S 23-88 Amd.1 or latest (Inspection: RDSO). | Numbers | 150.00 | 97 | 14,550 |
| 45 | Supply of Terminal Block: 6 way Poly butylene Terephthalate (PBT) of size 25mm (link centre to centre) as per RDSO Drg No. SA23756-Alt.3 or latest, S23757/Alt.4 or latest and Specns IRS: S75-2006 Rev.2.0 (Tentative) or latest, IRS:S23-88 Amd.1 or latest (Inspection: RDSO). | Numbers | 500.00 | 406 | 2,03,000 |
| 46 | Supply of Modular Terminal Block (WAGO or similar) as per RDSO Specn RDSO-SPN-189- 2004 Ver.3.0 or latest consisting the following parts: a) 2 conductor disconnect Terminal Block - 6 Nos.b) End-intermediate plate suitable for 2 conductor disconnect terminal - 1 No.c) Screw less end stop similar to WACO Model No. 249-117 - 2 Nos.d) Insulated jumper WAGO Model 280- 402 - 5 Nos.e) Din Rail - 0.1 metre per set (in length of 1 metre for every ten set) (Inspection: RDSO). | Set | 120.00 | 703 | 84,360 |
| 47 | Supply of mini WSB Markers for Modular Terminals WAGO Model No. or similar - 100 Nos. (Inspection: Consignee). | Set | 100.00 | 64 | 6,400 |
| 48 | Supply of Non-Deteriorating type of Fuse Holders and Fuse Links 240V AC/DC as per Specn IRS: S 78-2006 or latest, IS 13703 (Part 2):1993 knife edge type Fuse of El Fuse Link type (upto 20A) - Fuse Holders 20A capacity (Inspection: RDSO). | Numbers | 100.00 | 220 | 22,000 |
| 49 | Supply of Non-Deteriorating type of Fuse Folders and Fuse Links 240V AC/DC as per Specn IRS: S 78-2006 or latest, IS 13703 (Part 2): 1993 knife edge type Fuse of El Fuse Link type (upto 20A) - Fuse Link 1A/2A /6A/10A/16A/20A as specified by Engineer in charge (Inspection: RDSO). | Numbers | 500.00 | 31 | 15,500 |
| 50 | Supply of Multi-strand, single core, copper conductor 16/0.2 (16 wires, diameter of each wire is 0.20mm) (0.5 Sq.mm) wire coil as per Specns IS 694:2010 or latest, IRS: S 76-89 Amd.3 or latest. Length of coil should be 100m. Colour of coil to be specified by Engineer in charge (Inspection: RDSO). (Unit: Coil) | Numbers | 400.00 | 1,153 | 4,61,200 |
| 51 | "Supply of Battery Charger of capacity 230V AC/110V DC, 30A single phase, Signalling/Telecom. Installation as per Specn IRS: S 86-2000 Amd.4 or latest (Inspection: RDSO). | Numbers | 2.00 | 1,10,464 | 2,20,928 |
| 52 | Supply of Battery Charger of various capacity 230V AC/24-26-28V DC, 30A capacity as per Specn IRS: S 86-2000 Amd.4 or latest (Inspection: RDSO). | Numbers | 2.00 | 55,373 | 1,10,746 |
| 53 | Supply of Transformer - Rectifier set with 230V AC input, 24V-30V DC output, 5A as per Specn IRS: S 91-2014 Ver.1.0 or latest (Inspection: RDSO). | Numbers | 4.00 | 25,960 | 1,03,840 |
| 54 | Supply of Thermo Shrink Jointing Kit for jointing underground 0.9mm Dia conductor 6 Quad cable as per Specn IRS: TC 77-2012 Rev.3 (Amd.1 to Amd.3) or latest (Inspection: RDSO). | Numbers | 100.00 | 3,715 | 3,71,500 |
| 55 | Supply of Permanently lubricated HDPE Duct with outer Diameter of 40mm and inner Diameter of 33mm as per Specn RDSO/SPN/TC/45/ 2013 Rev.2.0. The length of the Duct shall be 1 Km. Two end plugs shall be provided along with the drum (Inspection: RITES). | Kilometre | 32.00 | 66,223 | 21,19,136 |
| 56 | Supply of Plastic Couplers - Slip fit/Push type for permanently lubricated HDPE Duct (To be procured from RDSO approved Firms) (Inspection: Consignee). | Numbers | 120.00 | 85 | 10,200 |
| 57 | Supply of End plug for permanently lubricated HDPE Duct (To be procured from RDSO approved Firms (Inspection: Consignee). | Numbers | 120.00 | 34 | 4,080 |
| 58 | Supply of Cable sealing plugs for permanently lubricated HDPE Duct (To be procured from RDSO approved Firms (Inspection: Consignee). | Numbers | 30.00 | 43 | 1,290 |
| 59 | Supply of Rotary Duct cutter suitable for cutting HDPE Ducts of Diameter 20mm to 42mm. The Duct cutter shall have a facility of replaceable blades. The blades shall be of high carbon steel (Inspection: Consignee). | Numbers | 8.00 | 1,046 | 8,368 |
| 60 | Supply of 50mmx6mm GI tape for interconnecting earth electrodes (Inspection: Consignee). | Metre | 200.00 | 546 | 1,09,200 |
| 61 | Supply of SilaneSiloxane Aliphatic Urethane Resin Blend Solvent based high technology membrane radiant heat reflecting insulating thermal barrier coating as per RDSO letter No. STS/E/Apparatus Case (Fabricated) Vol.II, dated 06/06/2012 (Inspection: Consignee). | Litre | 15.00 | 6,183 | 92,745 |
| 62 | Supply of Universal Locks with one steel key for every ten locks or part thereof (For example, if locks ordered is 10, 1 key is to be supplied and if locks ordered is 20, 2 keys to be supplied. However, 2 keys to be supplied if locks ordered is between 11 and 19) (Inspection: Consignee). | Numbers | 100.00 | 195 | 19,500 |
| 63 | Supply of Electric Track Drilling Machine shall be suitable for operating on 110V, 50Hz AC/DC fully insulated and no-load RPM shall be 1900/ 1000 and the power input is 550W. Machine with suitable inter changeable track mounting stand and drilling to be designed with adjustable facility and along with a set of 20 Nos. of 7.2mm Dia Bosch MSS drill bit, Drill check Dia 13mm and drilling dia in steel 8mm/ 13mm along with packing accessories (Inspection: Consignee). | Numbers | 3.00 | 22,602 | 67,806 |
| 64 | Supply of Godrej Navtal Locks with Diameter of 50mm with 3 keys (Inspection: Consignee). | Numbers | 10.00 | 563 | 5,630 |
| 65 | Supply of Key Chains with ring and plastic name plate of dimensions 60mmx20mmx3mm. The plastic name plate shall be engraved with station name on one side and key particulars on the other as specified by the site in-charge (Inspection: Consignee). | Numbers | 10.00 | 34 | 340 |
| 66 | Supply of Double Key Lock for Relay Room (Inspection: Consignee). | Numbers | 10.00 | 1,233 | 12,330 |
| 67 | Printing, binding & supply of the following Registers with latest proforma as given by Engineer in-charge. Each Eegister shall be of 100 pages.1) Station Asset Register, 2) Deficiencies,3) Officer Inspection Book, 4) Station Message Book,5) Infringement Measurement Book for Signaling Assets,6) Route Cancellation Register, 7) Relay Room Key Register,8) Selection Circuit Testing Register, 9) Cable Testing Register,10) Signal Maintenance Record, 11) Battery Maintenance Register,12) Mechanical Signaling Register, 13) Axle Counter Maintenance Register,14) SSDAC/HASSDAC/MSDAC Maintenance Register,15) Block Instrument Maintenance Register,16) Track Circuit Maintenance Register,17) Mechanical Lifting Barriers Maintenance Register,18) Electrical Lifting Barriers Maintenance Register,19) Electrically Operated Point Maintenance Register,20) Electronic Interlocking Maintenance Register,21) Location Box Maintenance Register,22) Earth Testing Record Register,23) Joint Inspection of Points and Crossings Register,24) Joint Inspection of Track Circuits,25) Joint Inspection of Track Circuits with OHE,26) Diesel Generator/Solar Panel Register &27) UFSBI maintenance register (Inspection: Consignee).(Unit: per Regr.) | Numbers | 1000.00 | 358 | 3,58,000 |
| 68 | Supply of true RMS 5 Digit 60000 Counts Digital Multi Meter with the following specification.1. Frequency range - 6Hz to 1MHz mV AC,2. Bandwidth - 10kHz, 3. AC voltage range - 1mV - 1000V, ± 0.5%, 4. DC voltage range - 1µV - 1000V, ±0.05%, 5. AC current range - 1µA - 10A, ± 0.5%,6. DC current range - 1nA - 10A, ± 0.2%,7. Capacitance range - 1pF - 10000µF,8. Data logging - 32000 Readings, 9. Dual display - Available &10. Other features - Shall have temperature measurement, diode, continuity, duty cycle measurement, self battery voltage measurement, low pass filter, Min, Max and Average value recording, back light, bar graph, protective rubber holster (Inspection: Consignee). | Numbers | 4.00 | 15,157 | 60,628 |
| 69 | Supply of Clip On Meter of Model Fluke 317 or similar with the following specification;1. True RMS responding,2. Voltage - DC 600V, AC 600V, DC accuracy - ±1% + 4 digit, 3. AC accuracy - ±1.5% + 5 digit,4. Current - DC 600A, AC 600A, AC accuracy: - ±1.5% + 5 counts, AC/ DC current measurement,5. Unique 40A low frequency measurements capability with 0.01A resolution,6. Special filter circuit to enable accurate measurement of PWM output,7. Additional measurement of resistance,8. Continuity check feature,9. Data hold features with large, easy to read backlight display,10. Calibration certificate &11. 1 year warranty(Inspection: Consignee). | Numbers | 4.00 | 20,086 | 80,344 |
| 70 | Supply of Analog Insulation Tester of Model No. Meco MC 941 or better- 500V/1000 M Ohms (Inspection: Consignee). | Numbers | 4.00 | 4,961 | 19,844 |
| 71 | Supply of Analog Earth Tester of WACO Make or better along with test kit and leather case or better (Inspection: Consignee). | Numbers | 4.00 | 5,884 | 23,536 |
| 72 | Supply of Digital Transmission Measuring Set as per Specn IRS: TC 43-87 APLAB or better (Inspection: Consignee). | Numbers | 4.00 | 27,853 | 1,11,412 |
| 73 | Supply of Double Walled Corrugated (DWC) HDPE Duct of outer Diameter 63mm and inner Diameter 50mm of length of 6m as per Specn RDSO/SPN/204/2011 Ver.1.1 Amd.1 or latest. The Duct shall be supplied along with push-fit type O-ring coupler or end cap (Inspection: Consignee). | Numbers | 1075.00 | 875 | 9,40,625 |
| 74 | Supply of Double Walled Corrugated (DWC) HDPE Duct of outer Diameter 180mm and inner Diameter 153mm of length of 6m as per Specn RDSO/SPN/204/2011 Ver.1.1 Amd.1 or latest. The Duct shall be supplied along with push-fit type O-ring coupler or end cap (Inspection: Consignee). | Numbers | 30.00 | 3,827 | 1,14,810 |
| Schedule total | ₹93,95,758 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril2022.pdf
ATTACHMENT
GCCcorrectionSlip1to10.pdf
ATTACHMENT
GCCCorrectionSlipNo.11.pdf
ATTACHMENT
GCCCorrectionSlipNo-12.pdf
ATTACHMENT
LetterofCredit.pdf
ATTACHMENT
MakeinindiaPolicy1.pdf
ATTACHMENT
Experience.pdf
ATTACHMENT
Annexure-VIBTurnover.pdf
ATTACHMENT
Acceptanceofe-BankGuaranteee-BGinWorksContracts.pdf
ATTACHMENT
TD26.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .