| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC | L1 | Accepted-AOC Successful bidder | |
| 2 | L2₹24.9 L+₹1.6 L (7.08%)Rejected-Finance NEAR KRIPAN GATE PO BINNAGURI DIST JALPAIGURI W B PIN 735203 | JALPAIGURI | WEST BENGAL | 735203 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹25.9 L+₹2.7 L (11.5%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹48,600
Closing Date
19 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Sambra
GE (AF) Sambra ATS Belgaum 591124
PROVN OF CERTAIN EM REVNUE AND MINOR WORKS AT ATS BELGAVI
2021_MES_497338_2
8681/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Sambra
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Sambra
₹48,600
Yes
20 Apr 2022
28 Jan 2022
21 Feb 2022
28 Jan 2022
19 Feb 2022
7 Feb 2022
60 days
Amount
M & L Sub main wiring with two single core FRLS PVC insulated cables with multi stranded copper conductor 1100Volt grade 2.5 sq mm drawn through and including suitable size of non-metallic PVC conduit / PVC casing and capping and accessories fixed on walls, roofs, floors etc with one run of 2.5 sqmm FRLS PVC insulated as earth continuity conductor cable and connecting up to earth dolly for controlling of building security light complete all as specified and directed. Note : Three runs of 2.5 sqmm copper conductor and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
S & F Transparent FRP junction box of size 20cm X 14cm X 95cmm with self locking arrangement comprising of one No MCB Single Pole 6 Amps with suitable din channel, 4 way 16A connector fixed to pole with M S flat iron 25x4mm clamps, nuts and bolts and connecting the incoming and outgoing cables all as specified and directed.
S & F Distribution board, double door, 02 way, Single Pole Neutral, 200 Amps rated bus bar, 240 Volts all as specified and directed.
S & F MCB Single Pole Neutral, 240 volts, 06 to 32 Amps, 10 KA rupturing capacity all as specified and directed.
S & F Street light LED 25 Watt made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP opening, seperate driver compartment, new generation energy saving, enviromental friendly, long life with IP-66 protection and impact resistance of IK07 with fixing arrangement such as GI pipe bracket, MS clamp ,Nut bolts etc and connecting all as specified and directed.
M & L Point wiring with PVC insulated and unsheathed multi stranded 1.5 Sqmm FRLS copper Cable drawn through and including PVC casing capping 20/25 mm width with all accessories, 1.6 mm thick pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover for fixing switch, socket, regulator etc of suitable size to be fixed on wall including PVC insulated & unsheathed multi stranded 1.5 Sqmm FRLS copper Cable as earth continuity connected with common earth dolly finishing with white washing/colour washing / distempering to match the existing surfaces complete for One light/fan point controlled by one, one way switch 5 Amp complete all as specified & directed
M & L Point wiring with PVC insulated and unsheathed multi stranded 2.5 Sqmm FRLS copper Cable drawn through and including PVC casing capping suitable width with all accessories, 1.6 mm thick pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover for fixing switch, socket, regulator etc of suitable size to be fixed on wall including PVC insulated & unsheathed multi stranded 2.5 Sqmm FRLS copper Cable as earth continuity connected with common earth dolly finishing with white washing/colour washing / distempering to match the existing surfaces complete for one 3 pin switch socket outlet 15 Amp independent complete all as specified & directed
S & F Switch piano flush button, single pole, one way, 5 Amp, 240 Volts complete all as specified & directed
S & F Swicth Socket combination 2 in 1, 3 pin 16 Amp flush type 240 volts (Box type) complete all as specified
S & F ceiling rose surface backelite three terminal 240 volts complete all as specified & directed
S & F ceiling fans 1200 mm sweep with blades, down rods, electronic regulator and accessories, 230 Volts, Min air delivery 210 CFM with service value 6.00 BEE, Five star rated with brushless direct current motor (BLDC) technology complete all as specified & directed
S & F exhaust fan, single phase, heavy duty, metal body, 300 mm (12") sweep, 900 RPM including fixing of mounting frame in the round hole cutting in the wall of brick/stone masonary by means of rugged bolts, nuts and washers etc & making good disturbed surfaces of walls, including louver shutter on outer surface of the wall and connecting with and including three core copper conductor flexible cord of 0.5 Sqmm cross sectional area of required length from ceiling rose to the porcelain connector block of the exhaust fan complete all as specified and directed. Note : Quoted rate is deemed to be included the cutting in the wall and making good the surface to match with the existing surfaces.
Supply, installation, Testing & Commissioning of 7.5 KVA Isolation transformer, Single phase, air cooled, 50 Hz, Copper wound, class of insulation A metallic body duly powder coated designed for input Voltage range 240+-2.5% and output voltage range 240+-2.5%, Ratio 1:1, Vector Group : Dyn 11, eficiency more than 95%, Potential difference between neutral to earth less than one volt with all standard fittings, floor mounted, indoor type all as specified & directed
M&L Earthing with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised ironl including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement weighing not less than 1.87 kg/Sqm with suitable handle made of 12 mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in Electrical Plate No 3 of SSR Part-I and testing on completion.
Supply, laying and testing of L T under ground cable XLPE insulated armoured heavy duty electric aluminium conductor of size 2 core 10 sqmm, 1100 Volts grade, laid in trenches / passing through pipes complete all as specified and as directed. Note:- Excavation and earth work, brick protection and sand cushioning will be measured and paid separately.
Excavation in trenches not exceeding 1.5 m depth for laying cables and getting out in hard/dense soil for laying cable/erecting poles etc complete all as specified and as directed. .
Supply and spreading river sand for cable cushioning in trenches all as per clause 19.75 of SSR Part-I complete all as specified and as directed.
Supply and laying well burnt sub class B bricks old size bricks, laid flat dry, in trenches with width of the bricks laid to the axis of cable for cable protection complete all as specified and as directed.
Returning and filling in soil including spreading leveling watering and well ramming in layers not exceeding 25cm all as specified.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point.
Cutting the tar macadam road / hard standings for laying cable not exc. 45cm wide and 60cm in depth and getting out including filing back and finishing it with PCC complete all as specified and as directed.
S & F Sub main wiring two single core PVC insulated cables with copper conductor 1100Volts grade 6 sqmm drawn through and including suitable size of non-metallic PVC rigid conduit and conduit accessories / casing and capping fixed on walls, roofs or floors including one run of 6 sqmm PVC insulated cable as earth continuity conductor and connecting up complete all as specified and directed. NOTE:- Three runs of 6 sqmm PVC insulated copper cable and one run of PVC rigid conduit and conduit accessories / casing and capping will be measured as one unit length.
S & F Galvanised Iron wire 4mm dia buried in ground / fixed on wall including porcelain base insulators at interval of 0.5 mtr complete all as specified and as directed
S & F sheet metal enclosure factory made distribution board 240 volts SPN 2 Way complete all as specified and as directed
M & L MCB SPN, 6 to 32 Amps, 240 volts, 50 Hz AC supply complete all as specified and directed.
Material and labour for chemical earthing pit of suitable size with copper earth plate of size 900 mm x 600 mm x 5 mm thick burried in ground vertically to a depth not less than 4 metre below ground level with top edge of plate at a depth not less than 2.95 metre below nominal ground level with a bottom layer MgSO4 of 100 mm thick or 100kg whichever is more, earth plate surrounded with graphite powder, vegetable soil mixture, charcoal 250kg and salt crystal 200 kg around and 150 mm above the plate and MgSO4 100 mm thick or 100kg whichever is more at top layer and the remaining portion filled with excavated earth and connected with copper strip 32mm x 6mm duly brazed and by means of bolts, nuts and washers upto 7.5 metre length with G I pipe of suitable dia for earth strip protection and connected to earthing test point, GI pipe light grade 25mm bore for watering with funnel and wire mesh complete including provision of earth pit with necessary earth work, PCC 1:2:4 type B1 chamber, Cast iron frame with hinged pit cover of size 12” x 12” having not less than 7 kilogram of weight complete all as specified and directed.
S & F Copper Strip of size 20 x 3 mm for inter connection of earthings and to connect the earthing to the main panel all as specified and directed.
M & L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screw all as specified and directed.
M & L Cutting holes in brick walls in cement mortar depth of embedded portion of holdfasts or lugs exc. half brick but not exc. one brick inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required all as specified and directed.
M & L mild steeel straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; will ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe410-0 or Fe 310-0 all as specified and directed.
M & L Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doo0rs etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; grade Fe 290 (Gde E-165) complete all as specified and directed.
M & L mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
M & L Mild steel, plain black sheet 1.25mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc.complete all as specified and directed.
S & F Butt hinges 125mm long, medium weight, cold rolled mild steel complete all as specified and directed.
S & F Mild steel barrel tower blots 200mm stove enamelled black with bright bolt all as specified and directed.
S & F Mild steel pressed handles 125mm, oval type, stove enamelled black all as specified and directed.
S & F Mild steel sliding door bolt 300mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate all as specified and directed.
M & L Preparation of new steel surfaces of any discription over 10 cm width or girth and applying two coats of synthetic enemal paint over a coat of red oxide primer complete all as specified and directed
Taking down cement plaster on brick or stone walls etc including racking out joints hacking for key, scrubbing down with water etc complete including removing rubbish off the premises all as specified and as directed.
M & L Rendering 15mm thick on fair faces of brick masonry or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement all as specified and as directed.
M & L Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) all as specified and as directed.
M & L Two layers of CRACK X-PASTE filling compound on internal/external faces as in wall and ceiling for filling in cracks (size of filling shall not be more than 5mm wide and 5mm deep all as specified and as directed.
M & L applying brush bond RFX two components elastomeric cementious water proofing coating for wall surfaces if 1mm thickness over plastered surfaces all as per manufacturer instruction and as directed
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade, stranded aluminium conductor of size 95 sqmm x 3.5 core complete all as specified & directed
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade, stranded aluminium conductor of size 10 sqmm x 4 core complete all as specified & directed
Supply, installation, Testing & Commissioning of 25 KVA Isolation transformer, three phase, Oil cooled, 50 Hz, Copper wound, class of insulation A, metallic body duly powder coated designed for input Voltage range 415+-5% and output voltage range 415+-5%, Ratio 1:1, Vector Group : Dyn 11, Delta - star with first filling of transformer oil of requisite di-electric strength up to level, eficiency more than 95%, seperate neutral bushing shall be brought out for earthing. Potential difference between neutral to earth less than one volt with all standard fittings like digital temperature meter, adequate number of cooling radiators, lifting hooks one set, Earthing terminal two Nos complete with Over load / short circuit protection, floor mounted, indoor type complete all as specified and as directed.
M & L Earthing with galvanized iron earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 M below normal ground level with top edge of earth plate at a depth not less than 1.5 M below normal ground level connected to and including GI strip 25X4 mm as earth lead by means of bolts and nuts, check nuts and washers etc made of GI & connected to equipment and earthing test point , earth dolly all as shown in electric plate No 3 of SSR Part-I including all necessary earth work excavation, PCC chamber, RCC 1:2:4 cover with handle, GI watering pipe 20mm dia medium grade, GI pipe 40 mm dia light grade for protection of earth strip ,wire mesh, funnel, charcoal dust & common salt, etc all as specified and directed.
S & F G I Strip of size 25x4 mm earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed
Supply and Fix split type air conditioner electric driven, single phase of capacity 2 TR, BEE 5 star rated including inner unit & outer unit including necessary M S brackets complete all as specified.
Supply and fix voltage stabilizer for automatic operation of capacity 5 KVA, single phase naturally air cooled indoor type & designed for input variation between 170 volts to 250 volts with output voltage stabilized at 230 volts with accuracy of +/- 2.5 % complete all as specified & directed
S & F Time controller system for air conditioner of 230 volts, 50 Hz (+/- 15%), Contact Rating 30 Amp at 230 volt for compressor and 5 Amp at 230 volt for alarm, wall mounted, Temperature sensing range - 0.1 to 50 Degree C and Resolution - 0.1 Degree C all as specified and directed.
M & L Sub main wiring four single core 10 sq mm FRLS PVC insulated cables with copper conductor 1100Volts grade drawn through and including suitable size of non-metallic PVC rigid conduit with accessories / casing and capping fixed up walls, roofs or floors including two runs of 10 sqmm FRLS PVC insulated cable as earth continuity conductor cable and connecting up complete all as specified and as directed. Note : Six runs of 10 sqmm copper conductor and one run of PVC casing & capping / PVC conduit shall be measured as one unit length.
M & L Sub main wiring two single core 4 sq mm FRLS PVC insulated cables with copper conductor 1100Volts grade drawn through and including suitable size of non-metallic PVC rigid conduit with conduit accessories / casing and capping fixed up walls, roofs or floors including one run of 4 sqmm FRLS PVC insulated cable as earth continuity conductor cable and connecting up complete all as specified and as directed. Note : Three runs of 4 sqmm copper conductor and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
S & F sheet metal enclosure distribution board, SPN 4 Way, 240 volts, double door factory made with 200 Amps rated bus bar, IP-43 Protection, Mechanical Impact Strength IK 08 complete all as specified and as directed.
M & L MCCB 63 Amps, 4 pole, 16KA capacity with fixed thermal magnetic setting including connecting up with suitable alumnium cable lugs etc. with suitable sheet metal enclosure complete all as specified and as directed.
S & F MCB TPN 6 to 32 Amps,'C' Series, 240 volts, 50 Hz AC supply complete all as specified & directed
S & F sheet metal enclosure with socket plug top and MCBs single pole and earth metal enclouser with a two pin and earth plug with socket 20 Amp with one single pole MCB single phase 240 Volt complete all as specified and directed.
M & L Galvanised iron pipe 40mm dia , light grade, laid in trenches or fixed on poles all as specified and directed.
M & L Galvanised iron pipe 80mm dia , light grade, laid in trenches or fixed on poles all as specified and directed.
Supply, install, testing and commissioning of floor mounted LT panel board AC 415 V, 50 HZ,3 Phase, 4 wire of suitable size for accomodating the following accessories, totally enclosed self supporting structure / cubicle, fully compartmentalized type, suitable for outdoor use, bottom cable entry with suitable cable glands and one side cable ally, structure made out of 3.15 mm thick CRCA steel sheet with angle iron frame work and 4 legs of ISA 50X50X5 mm, grouted in PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover switch and MCCBs, hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 8 - tank metal treatment process and duly powder coated, CPRI approved, testing complete all as specified and directed :- (Main Panel) NOTE:- Connection from Main bus bar to Outgoing MCCB should be provided through bus bar of suitable rating instead of copper wires
OUTGOING FEEDERS (a) Supply and fixing MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 125 Amps with Fixed thermal and fixed magnetic setting-02 Nos (b) Supply and fixing MCCB 4 pole 415 Volts of breaking capacity of 16 KA of 63 Amps with Fixed thermal and fixed magnetic setting-03 Nos
N K CONSTRUCTION
M/s. VIJAY ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .