Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC | ₹40.4 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹41.9 LRejected-Finance 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | RAJASTHAN | 334001 | ₹41.9 L | L2 | Rejected-Finance Other than lowest Bidder |
| 3 | L3₹42.1 LRejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹42.1 L | L3 | Rejected-Finance Other than lowest Bidder |
| 4 | L4₹45.3 LRejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | ₹45.3 L | L4 | Rejected-Finance Other than lowest Bidder |
| 5 | L5₹47.0 LRejected-Finance 6 U 34 JAWAHAR NAGAR SRI GANGANAGAR SRI GANGANAGAR RAJASTHAN 335001 | GANGANAGAR | RAJASTHAN | 335001 | ₹47.0 L | L5 | Rejected-Finance Other than lowest Bidder |
| Sl No | Description | Qty | Unit | RAJENDER ENTERPRISES L1 | M/S BUDHRAM BISHNOI L3 | Beenu Co. Company L2 | Ankit Jindal And Company L5 | BIDAWAT ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil, complete all as specified and directed. | 431.63 | Sqm | 9 ₹3,884.67 | 39 ₹16,833.57 | 29 ₹12,517.27 | 50 ₹21,581.50 | 10 ₹4,316.30 |
| 2.00 | Excavating in trenches in hard/dense soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out, complete all as specified and directed | 60.44 | Cum | 117 ₹7,071.48 | 189 ₹11,423.16 | 180 ₹10,879.20 | 650 ₹39,286 | 115 ₹6,950.60 |
| 3.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed | 43.77 | Cum | 72 ₹3,151.44 | 59 ₹2,582.43 | 39 ₹1,707.03 | 140 ₹6,127.80 | 70 ₹3,063.90 |
| 4.00 | Removing excavated soil exc. 1.5km but n exc. 5 km and depositing where directed, complete all as specified and directed | 15 | Cum | 90 ₹1,350 | 529 ₹7,935 | 45 ₹675 | 700 ₹10,500 | 100 ₹1,500 |
| 5.00 | M& L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area, complete all as specified and directed. | 172.5 | Sqm | 117 ₹20,182.50 | 89 ₹15,352.50 | 49 ₹8,452.50 | 65 ₹11,212.50 | 135 ₹23,287.50 |
| 6.00 | M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured), complete all as specified and directed. | 130.58 | Sqm | 135 ₹17,628.30 | 99 ₹12,927.42 | 98 ₹12,796.84 | 125 ₹16,322.50 | 140 ₹18,281.20 |
| 7.00 | M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface with ATT, complete all as specified and directed. | 88 | Sqm | 126 ₹11,088 | 89 ₹7,832 | 59 ₹5,192 | 65 ₹5,720 | 120 ₹10,560 |
| 8.00 | M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area, complete all as specified and directed. | 25.79 | Sqm | 126 ₹3,249.54 | 89 ₹2,295.31 | 49 ₹1,263.71 | 65 ₹1,676.35 | 120 ₹3,094.80 |
| 9.00 | M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter, wall, complete all as specified and directed. | 39.84 | Rm | 72 ₹2,868.48 | 89 ₹3,545.76 | 29 ₹1,155.36 | 40 ₹1,593.60 | 90 ₹3,585.60 |
| 10.00 | M&L cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base / sub-floor below footing or foundation, plinth beam complete all as specified and directed. | 4.72 | Cum | 3,600 ₹16,992 | 2,229 ₹10,520.88 | 2,500 ₹11,800 | 6,000 ₹28,320 | 3,200 ₹15,104 |
Updated dates
Tender Value
₹43.5 L
EMD Value
₹87,100
Closing Date
23 Jan 2026, 6:00 pmClosed
GE AF NAL
GE AF NAL
AS DESCRIBED IN BOQ
2025_MES_746273_1
GE (AF) NAL /T-66/2025-26
Open Tender
Civil Works
180 days
GE AF NAL
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE AF NAL
₹87,100
Yes
14 Feb 2026
26 Dec 2025
26 Jan 2026
26 Dec 2025
23 Jan 2026
10 Jan 2026
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil, complete all as specified and directed.
Excavating in trenches in hard/dense soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out, complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed
Removing excavated soil exc. 1.5km but n exc. 5 km and depositing where directed, complete all as specified and directed
M& L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area, complete all as specified and directed.
M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured), complete all as specified and directed.
M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface with ATT, complete all as specified and directed.
M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area, complete all as specified and directed.
M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter, wall, complete all as specified and directed.
M&L cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base / sub-floor below footing or foundation, plinth beam complete all as specified and directed.
M&L for 75 mm Cement concrete in using 40mm graded stone aggregate type C2 (1:3:6) as in subfloors, sub base, floors and pavings etc,complete all as specified and directed.
M&L for reinforced cement concrete M-25 design mix (using 20mm graded stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design mix) (using 20mm graded stone aggregate) as Columns, pillars, piers, posts and struts etc and like, complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design mix) (using 20mm graded stone aggregate) as in roof beams, lintel beam, slabs supported on walls, roofs, landings balconies canopies, deck slabs and in shelves balconies canopies etc and like, complete all as specified and directed.
M&L for Formwork to sides of concrete foundations, footings, columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter, complete all as specified and directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and directed.
M&L formwork to soffits of suspended slab such as roof slabs, floor slabs, landings, beams and similar work not exc 200 mm thick horizontal or sloping , rough finished flat surfaces complete all as specified and directed.
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm width, complete all as specified and directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc, complete all as specified and directed.
S&F mild steel TMT bars 10mm dia and over, cut to length & bent to shape required including cranking, bending spirally for hoping for column, stirrups of beams and columns hooking ends & binding with and including mild steel wire not less than on 0.9mm dia or securing with clips, complete all as specified and directed.
S&F mild steel TMT bars 6-8mm dia as in stirrups, spacers and binders., cut to length & bent to shape required including cranking, bending spirally for hoping for column, stirrups of beams and columns hooking ends & binding with and including mild steel wire not less than on 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for PCC(1:3:6) type C1 using 20mm graded aggregate as in plinth protection of avg 75mm thick and finishing cement concrete surface even and smooth without using extra cement, complete all as specified and directed.
M&L for Forming Contraction (Dummy) joints in Plinth Protection at every 2.5m length 10mm wide, filled with sealing compound of Gd A, complete all as specified and directed.
Demolition of brick or stone masonry built in cement mortar incl all quoins, arches, pillar etc.as in opening, complete all as specified and directed
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for 25 mm thick Cement concrete 1:2:4 type B0 using 12.50mm graded stone aggregate over sub base concrete floors, surface fair finished and even and rough to receive floor finishes, complete all as specified and directed.
M & L for machine cut Kota Stone slab as in flooring / landing/treads of stairs , 20-25 mm thick over and including 15mm thick cement screed bed in CM 1:4 , laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab and including rubbing and polishing and making grooves in treads ( as required ) complete all as specified and directed.
M & L machine cut Kota Stone slab as in skirting/ Risers of stairs , 20-25 mm thick over and including 10 mm thick rendering in CM 1:4 , laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab and including rubbing and polishing complete all as specified and directed.
Dismantling of wall and floor tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off premises, complete all as specified and directed.
M&L for glazed ceramic coloured wall tiles 450x300x7mm thick on vertical surfaces such as dados set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat in CM 1:4, complete all as specified and directed.
M&L for non skid ceramic coloured joint free tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.16 Sqm but not exceeding 0.38 Sqm in floors etc with design pattern set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles over and including 15mm thick screed bed in CM 1:6 & complete all as specified and directed.
Dismantling of brick tiles or terracing tiles or Pre-cast Cement concrete tiles single layer on roof, jointed and grouted/pointed in cement mortar including cleaning serviceable tiles and stacking properly for reuse, disposal of unserviceable tiles and debris/rubbles from site complete all as specified and directed.
Demolition of cement Concrete of any description and in any position including any type of roof treatment , PCC padding, lime concrete, mud etc, complete all as specified and directed. Note: All demolished material / debris will be disposed off out side the Air force station Nal with out any extra cost to the govt. Contractor should arrange dumping site to dispose off material.
M & L for PCC (1:2:4) type B-0 (12.5 mm graded stone aggregates) as in roof kerbs, sloping padding in roof slab or mud stops, rounded or chamfered on edges, complete all as specified and directed.
M&L 15mm thick screed bedding in cement mortar 1:4 mixed with water proofing compound pidi proof LW @ 200ml per 50Kg cement as per manufacturers instructions on concrete surface of roof and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge (WPC shall be measured and paid separately)
M&L for water proofing treatment with APP based modified 5 layered prefabricated water proofing polymeric membrane over roof consisting of cleaning of concrete or plastered surface of roof and applying evenly a bitumen primer confirming to IS 3488 @0.3 kg per sqm followed by a tack coat @1.20 kg per sqm using 85/25 grade industrial hot blown bitumen over it laid with APP modified polymeric water proofing membrane minimum weighing 3kg per sqm reinforced with non woven polyester fabric (wt. not less than 170 gms/sqm) unrolled and bonded to substrate with longitudinal and end laps 100mm as per manufacturer's instruction, and including taking the APP membrane will be required where the parapet wall exceed 45cm for carrying over and taking into parapet walls, cut out neatly a horizontal groove 6.5 cm deep, 7.5 cm wide section with lower edge at not less than 15 cm above the graded roof surface and groove shall be finished smooth with cement mortar 1:4 with WPC where the parapet wall height is 45cm or less no grove will be required as the water proofing treatment will be carried over the top of parapet wall to its full thickness complete all as specified and directed.
M&Lfor 20mm thick Pre-cast Cement concrete tiles 1:2:4 type B0,(using 10 mm to 12.5 mm graded stone aggregate), with grey cement & no pigment machine pressed; set jointed and pointed in cement mortar 1:3, including screed bed 15mm thick in CM 1:6 complete all as specified and directed.
Supply only Liquid water proofing compound ISI marked, complete all as specified and directed.
M&L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 20 mm thick screed bed in CM 1:6, complete all as specified .
M&L for Rounding to edges of stone slabs one edge such as in steps & platform etc, complete all as specified and directed.
Supply and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) work for frames of doors, windows,ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws,complete all as specified and directed.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, rollers & dust proof brush for sliding door / window, complete all as specified and directed.
S & F 4.80 mm thick sheet glass of size n exc 0.5 sqm in each pane ordinary quality plain /tinted and including glazing with suitable rubber beads etc complete all as specified and directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
Anodised aluminum grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anode coating of grade AC15) of approved design/ pattern, with approved standard section and fixed to the existing window frame with CP. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminum standard section around the opening, complete all as specified and directed..
S&F Toughened glass 10mm thick as in hinged doors, partitions automatic doors and windows and similar work including cutting to shape, drilling holes required also including all necessary wall to glass hinge, glass to glass hinges, wall to glass connector, floor clamp, stabiliser rod with knobs, steel handle plastic parts complete all as specified and directed.
Taking down cement plaster on brick/stone/concrete walls /ceiling incl racking out joints etc,hacking for key, scrubing down with water etc & dispose off debris upto a distance n exc.500 mtrs where directed complete all as specified and directed. Note -Rate are applicable upto four storey height including all scaffolding work.
M&L for 15 mm thick rendering in two layers i.e. 10 mm thick in cement mortar 1:4 in first layer and 5 mm thick in cement mortar 1:4 mixed with approved water proofing compound on top layer,on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed. Note: Water proofing compound shall be measured & paid separately.).
M&L for preparation of new plastered surface and apply two coats of Acrylic Smooth exterior paint of required shade applied over one coat of alkali resistant primer in camouflage pattern complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in CM 1:6 finished even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of newly plastered surface of walls and applying two coat of oil bound distemper over a coat of chalk whitening over newly plastered surfaces of walls, pillars cornices etc complete all as specified and directed.
M&L for rendering 5 mm thick on ceiling in CM 1:3 finished even and smooth without using extra cement,complete all as specified and directed.
M&L preparation of new plastered surfaces of ceiling and applying three coat of white wash complete all as specified and directed.
M&L for preparation of old plastered/painted surfaces of walls and applying one coat of Acrylic Smooth exterior paint of required shade in camouflage pattern complete all as specified and directed.
M&L for preparation of old plastered/painted surfaces of ceiling and applying one coat of white wash on ceiling complete all as specified and directed.
M&L for preparation of old plastered/painted surfaces of walls and applying one coat of oil bound distemper on wall including cornices etc complete all as specified and directed.
S & F in repair vitreous china white wash down water closet pan (pedestal pattern) including white plastic seat cover with CP hinging device and PVC P type trap, including connection to trap, drain pipe, flushing cistern & anti syphonage pipe complete all as specified. Note : The cost of traps and plastic seat cover are included in this item.
S&F in repair 10 Ltr capacity PVC valveless symphonic action type flushing cistern white low level with ball valve float handle including bracket and flush pipe of polythylene of low or high density or PVC,32mm dia complete all as specified and directed Note:- Flush tank can be conceiled in wall if reqd i.e in the case of wall hung type water closet pan.
Supply and fixing in repair counter sink vitreous china wash hand basin white of minimum size 550 x 460 mm oval type including bracket, CP waste coupling,32mm PVCwaste pipe, chain, plug and porcelein stopper, complete all as specified and directed
Supply & fixing in repairs vitreous china urinal half stall type with CP spreader white with grating and union for discharge pipe, including providing and fixing plug, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement fixing with brackets, flush pipe, grating and union for discharge pipe, complete all as specified and directed.
Supply and fixing in repair PVC waste pipe 32/38/40mm dia, 600 to 750mm long, complete all as specified and directed.
S&F in repair central hole basin mixture with capstan heads,fancy type heavy duty,chromium plated,screwed down high pressure,with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe 15mm bore, complete all as specified and directed.
Taking up or down 15mm dia steel tubing and connections incl cleaning for refixing or removal to store, complete all as specified and directed.
S&F 15mm dia GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floors, complete all as specified and directed.
All as per sr item no 65 above but except pipe, complete all as specified and directed. Note - Serviceable pipe obtained from item no 64 shall be used after necessary cleaning
S&F in repair 15 mm stop valves/Angle valve but fancy type, chromium plated , cast copper alloy,screwed down,high pressure, with flange cap , screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
S&F in repair 15 mm dia Bib taps, long shank , cast copper alloy with crutch or butterfly handle, screwed down, crewed with flange cap for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
S&F in repair Chromium plated shower rose 125 mm dia with shower arms with or without swivel joints including fixing to steel pipe or union, complete all as specified and directed.
S&F 15 mm dia 45 cm long PVC water connection with brass nuts ( Hot and cold ) complete all as specified and directed.
S&F as in repair CP ( brass body ) towel Rail 600mm long fixed with and including Chromium plates brass screws and wooden /plastic cleats (minimum weight 170gms ) complete all as specified and directed.
S&F as in repair Health Faucet with 1.25 mtr flexible hose pipe & wall hook(Chrome) complete all as specified and directed.
S & F in repair long body stop valve15mm bore fancy type chromium plated with long shank and cup(concealed type) screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions, complete all as specified and directed.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, incl PVC straps/clamps fixed to walls bore of the pipe 110 mm, complete all as specified and directed.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches of bore of the pipe 75 mm, complete all as specified and directed.
S&F PVC(SWR) bends 110 mm dia. complete all as specified and as directed.
S&F PVC(SWR) bends 75 mm dia. complete all as specified and as directed.
S&F PVC(SWR) bends 110 mm dia. With access door, complete all as specified and as directed.
S&F PVC (SWR) junction single, (Single T) equal or unequal with access door 110 mm bore, complete all as specified and as directed.
M & L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement of any description, complete all as specified and as directed.
S&F Stainless steel ( SS 202 grade ) Curtain rod 25 mm dia 0.80 mm wall thickness, mild steel, chromium plated including supporting brackets and all fittings as per sample complete all specified and directed.
M&L for hard core of broken bricks of guage n.exc 63mm deposited spread and levelled in layer n.exc 15cm thick watered and well rammed to true surfaces, complete all specified and directed.
M & L for providing 75 mm thick PCC 1:4:8 type D-2 (using 40 mm agg.) in sub base of flooring, complete all as specified and directed.
Supply and laying design chequered cement concrete tiles (Glossy finish) 30mmx30mmx22mm thick made by table vibratory method set, jointed and pointed in neat cement slurry as in floors with grey cement & pigment over 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, with grey cement, pigment with 25mm thick sand filling, complete all as specified and directed.
M&L for providing, cement concrete type B1 (1:2:4) (20 mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges,complete all as specified and directed.
Excavation in post holes (or similar holes) in hard/dense soil, each in not exc. 0.50 cum getting out returning,filling in an ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm watering and removing surplus soil out of defence land and making good surface, complete all as specified & directed.
M&L for cement concrete type C2 1:3:6(40mm graded aggregate) as in posts( including caps and bases), complete all as specified & directed.
M&L for steelwork in tubular trusses, post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979, IS-4923-1997 grade Yst-310 & above, including embedding in concrete complete and all as specified and directed.
S&F MS plain plates, square cut, with riveted, bolted or welded attachment FE-410-W (Gde-E-250) quality A, complete and all as specified and directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n.exc 5cm long, diameter of neck in 5 to 10mm., complete and all as specified and directed.
M/L for Pre-painted galvalume aluminum zinc coating GI based corrugated or semi corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete and all as specified and directed.
Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete and all as specified and directed.
M &L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed..
S&F Plain, 3 mm thick Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) for crumple joint complete all specified and directed.
Taking down carefully copper /aluminium point wiring light/fan, socket or power point /AC point complete including fittings such as switches, sockets, ceiling rose, bell push, bell buzzer, lamp holder bracket, fan regulator, tube light fitting removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditioning separately ) and making good disturbed surfaces of walls,floor ,etc complete all as specified and as directed.
One fan / light Point controlled by one switch, with cables 1.5 sq.mm size
One 3 pin socket outlet, 5/6 amps, independent board, with cables 1.5 sq.mm size
One 3 pin socket outlet, 5/6 amps, same board, with cables 1.5 sq.mm size
One 3 pin socket outlet, 15/16 amps, independent board, with cables 2.5 sq.mm size
S & F Socket 6A/16A - 2/3 pin combined 2 module combined switch socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed by the Engineer-in-charge.
S & F modular type 2/3 pin shuttered type 5/6 A socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed by the Engineer-in-charge.
S & F modular type 15/16 A 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the Engineer-in-charge..
S & F modular type 5/6 A 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the Engineer-in-charge.
M & L for ceiling rose, surface bakelite, 65 x 50 mm, three terminals complete all as specified and as directed.
S & F Modular cover plate with frame of following module complete all as specified and directed. Note- Moduler switches, sockets and cover plate with frame shall be of same make and model.
8 Module
6 Module
3 Module
S & F rectangular modular metal flush mounted sunken block of following modules suitable for mounting modular switches & sockets complete all as specified and directed
8 Module
6 Module
3 Module
Supply and fixing step type electronic fan regulator , SP 230 Volt 100/120 watt complete all as specified and directed.
S&F energy saving decorating box type batten light fitting 230 volts surface mounted complete with high efficiency glare free light LED lamp 20 watt(4 Feet) blue coloured end caps with all accessories, pre- wired,aluminium housing,polycorbonate diffuser integrated heavy duty electronic driver having THD < 10% including providing flexible copper wire twin core cable complete all as specified and directed by Engineer in charge.
S&F energy saving decorating box type batten light fitting 230 volts surface mounted complete with high efficiency glare free light LED lamp 10 watt(2 Feet) blue coloured end caps with all accessories, pre- wired,aluminium housing,polycorbonate diffuser integrated heavy duty electronic driver having THD < 10% including providing flexible copper wire twin core cable complete all as specified and directed by Engineer in charge.
Supply and fixing recessed mounted 36W LED ceiling light fitting provided with best in class aesthetics premium white powder coated frame blends seamlessly with ceiling layout suitable for 600X600 MM modular ceiling grid and also can be suspended with provided kit, complete all as specified and directed by Engineer in charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) with complete all as specified and directed by Engineer in charge.
S&F sheet metal enclosure single pole and neutral enclosure with two pin and earth plug and socket complete with one MCB SP 20 Amps complete all as specified and directed by Engineer in charge.
Supply and laying sub main wiring complete with 03 runs ( phase, Neutral & Earthing colour code) of single core 10 sqmm fire retardant low smoke (FRLSH) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including concealed non metallic PVC conduit minimum dia 20mm dia ISI marked and accessories surface fixed on wall /floor etc complete all as specified and as directed. Note:- 03 runs of cable and 01 run of PVC conduit shall be measured as one unit for measurement purposes.
Supply and laying sub main wiring complete with 03 runs (Phase, Neutral & Earthing colour code) of single core 4 sqmm fire retardant low smoke and halogen (FRLSH) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including concealed non metallic PVC conduit minimum dia 20mm dia ISI marked and accessories surface fixed on wall /floor etc all as specified and as directed. Note:- 03 runs of cable and one run of PVC conduit shall be measured as one unit for measurement purposes.
Taking down carefully Distribution board SPN of any sizes & any capacity by unscrewing including MCB SP/SPN from existing location all as directed.
Supply and fixing MCB DB single pole and neutral 240 volt SPN 12 way with 200 Amps rated bus bar double door type complete all as specified and directed Note : Rate quoted shall deemed to be including for cutting existing wall for fixing DB in concealed making connections of sub main wiring (incoming and outgoing) with suitable size of cable lugs etc. and making good the existing surface.
Supply and fixing MCB DB single pole and neutral 240 volt SPN 8 way with 200 Amps rated bus bar double door type complete all as specified and directed Note : Rate quoted shall deemed to be including for cutting existing wall for fixing DB in concealed making connections of sub main wiring (incoming and outgoing) with suitable size of cable lugs etc. and making good the existing surface.
Supply and fixing MCB SPN 32 Amps 240Volts, breaking capacity 10 KA 'C' curve complete all as specified and directed.
Supply and fixing MCB SP 5-32 Amps 240Volts, Breaking capacity 10 KA 'C' curve complete all as specified and directed.
Supply and fixing vertical TPN DB double door, IP 45 protection with powder coated enclosure 4 way insulated busbar assembly including MCCB 4 pole, 415 V, 100A, 16 kA - 01 No complete all as specified and directed.
M&L for Earthing complete with GI earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.50 Mtr below ground level. The earth plate to be connected with earth lead of 4 mm dia galvanised iron or steel wire ,connected to earthing test point all as specified and directd.The GI earthing wire to be protected by galvanised iron pipe 15 mm bore (medium grade) up to ground level and there after with 15mm dia HDPE pipe up to test point. Earthing shall be include with providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of magnesium sulphate powder (compact thickness ) , 3rd layer with tibba sand up to the ground level. Earthing shall also be include for providing concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded stone aggregate), 50mm thick precast RCC (1:2:4) using 20mm graded stone aggregates in cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work etc. complete all as specified and directed.
Supply and fix electric water heater ,storage type steel body with copper inner tank and heating element upto 2KW capacity 25 litre ,BEE 5 Star rated complete with all accessories such as safety valve,thermostate ,NRV,connection pipes etc complete all as specified and directed.
Supply and fixing exhaust fan, steel body AC single Phase , 230V of size 300mm sweep with blades and frame and louvers with complete all as specified and directed.
Taking out existing unsv XLPE Cable of size 50/70Sqmm with complete all as specified and directed.
Supply, laying and testing XLPE Cable Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq.mm, 3.5 core etc, complete all as specified and directed.
Supply, laying and testing XLPE Cable Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq.mm, 3.5 core etc, complete all as specified and directed.
Supply, laying and testing XLPE Cable Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq.mm, 3.5 core etc, complete all as specified and directed.
Supply, laying and testing XLPE Cable Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq.mm, 4 core etc, complete all as specified and directed.
Supply, laying and testing XLPE Cable Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq.mm, 4 core etc, complete all as specified and directed.
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning filling in Including spreading, levelling. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Material and labour for tiba sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified. Note:- Punned thickness shall be measured.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
Taking out existing serviceable LT/HT Cable and water Pipe line with fittings and re-route the cable or Pipe at another location including extra cable or pipe of existing size and fittings, fixtures and cable joints as per site requirement with complete all as specified and directed. Note :- Excavation, returning / filling will be measured and paid separately under relevant items.
M&L for bus bar chamber cubical inclined top out door type made out of 3 mm thick MS sheet of size minimum size 600 x 450 x 450 mm, MS angle section 35 x 35mm x 5mm frame with front and back openable double door with provision of locking arrangement dust & varmin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly powder coated inside and outside of bus bar chamber with one coat of red oxide primer and two coat of synthetic enamel grey paint including aluminum busbar fixed horizontally in chamber of capacity 400 Amps for phases and 400 amps neutral for incoming and out going.(The gap between each bus bar shall be minimum 100mm ) The panel shall be suitable for 415 volts, 50 Hz, 3 phase 4 wire system (suitable for 01 incomer and 06 outgoing ) and shall have MCCB 250 Amp 4 pole 36 KA as incommer, including taking out existing unsv with complete all as specified and directed by Engineer-in-charge Note :- (i) Earth work, PCC work and MS works shall be included in the unit qouted rate . (ii) Cable gland of brass for different size of cable as per requirement for incoming and outgoing cable
S & F LED 150 W flood light fitting with lense, high luminous efficacy,protected to IP 66, toughened glass efficient high out put emitter LED for better distribution having surge protection 10 KV, sealed driver applicable for area lighting including electrical connection and taking out existing unsv lights with complete all as specified and directed
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine or manually without damage nearby electric cable, water pipe line etc including HDPE pipe of 80 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply and fix GI tubing light grade 80 mm bore for cable protection including taking out existing rusted GI Pipe of 50/80mm dia, with complete all as specified and directed.
Supply, installation, testing & commissioning hi wall split units inverter type with indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5Star rating and EER 5.0 ,electric driven single phase of capacity 2 TR with non CFC refrigerant including making electric connection with 4Sqmm single core multi stranded copper conductor FRLS cable from indoor unit to outdoor unit ,copper pipe required to connect outdoor unit and indoor unit and suitable size PVC pipe having nylon threaded reinforcement for condensed water from indoor unit to outside the bldg drain complete all specified and directed. Note : (a) Outdoor unit should be mounted on suitable size bracket embedded in the wall as recommended by the manufacturer.Rate quoted by the contractor should include the cost of all above accessories no extra payment will be made. (b) Copper condenser coil of outdoor unit necessary.
Taking out existing serviceable split AC, 2 TR capacity with indoor & outdoor unit including complete accessories and re-installed at other location with fittings , fixtures as per site requirement with testiing, commissioning complete all as specified and directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
BOQ_835651.xls
BOQ • 0.40 MB
TENDER_T66.pdf
Tender Documents • 3.20 MB
Download all tender documents and submit your bid