Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC 209 210 AGGARWAL TOWER PLOT NO 2 SECTOR 5 ROHINI NORTH WEST DELHI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L1 | Accepted-AOC accepted | |
| 2 | L2₹17.3 L+₹10,980 (0.64%)Rejected-AOC | L2 | Rejected-AOC rejected | |
| 3 | L2₹19.0 L+₹1.8 L (10.7%)Rejected-AOC FIRST FLOOR GEETA COMPLEX ROHTAK ROHTAK ROHTAK HARYANA 124001 | ROHTAK | HARYANA | 124001 | L2 | Rejected-AOC rejected | |
| 4 | L4₹19.0 L+₹1.9 L (10.9%)Rejected-AOC | L4 | Rejected-AOC rejected | |
| 5 | L5₹19.3 L+₹2.1 L (12.2%)Rejected-AOC | L5 | Rejected-AOC rejected |
Tender Value
₹23.6 L
EMD Value
₹47,160
Closing Date
30 Aug 2023, 5:00 pmClosed
VISHWNATH KHICHI
ED - Rohtak
Fire Alarm and PA System
2023_HRY_302941_1
20232CF78990 CB2D 4779 9C09 5063A32E77DA667BAR
Open Tender
Electrical Works
Works
120 days
BADLI
Technical documents as per approved DNIT conditions.
3 documents required · 3 mandatory
₹1,000
₹47,160
Yes
23 Nov 2023
10 Aug 2023
31 Aug 2023
10 Aug 2023
30 Aug 2023
10 Aug 2023
Amount
HSR Items
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.
NS Items
Supply Installation Testing Commissioning of minimum 1000 Mtr. Range Kheraj / National make SIRON generator provided at the roof of the building with separate Power SITC, relay.
Supply and erection of Fire Extinguishers duly hang on wall with necessary hook complete in all respect. Make Make: Safex / Minimax / Cease Fire).(i) ABC dry Powder extinguisher 6 Kg Cap
Supply and erection of Fire Extinguishers duly hang on wall with necessary hook complete in all respect. Make Make: Safex / Minimax / Cease Fire).(ii) Water CO2 9Ltr Cap
Supply and erection of Fire Extinguishers duly hang on wall with necessary hook complete in all respect. Make Make: Safex / Minimax / Cease Fire). (iii) CO2 type 4.5kg cap
Supply and erection of 1.5sqmm PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Havells /Polycab/Finolex
Supply, Installation, Testing and Commissioning of Micro Processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 3 Serial Ports. The pane\l shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in –charge of work. Make: Bosch FPA 1000 Series / GST 200 (EN) / Honeywell Morley Dxe Series / Seimens Cerberus
Supply, Installation, Testing and Commissioning of Analog Addressable Type Active Repeater fire alarm panel with Backlit LCD Display, having controls for reset, mute, Accept, Silence alarms and self test conforming to BS5839 standards and Duly approved by EN54/UN54/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Makes :Bosch FPA 1000 Series / Honeywell Morley Dxe Series / Siemens Cerberus, GST 200 (EN)
SITC of addressable multisensor detector with a combination of optical and thermal including base, auto addressing features as required. Detectors should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005. EMC safety for detector shall be 50 V/m. shall be EN54/VDS/UL certification. ((Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Makes :Bosch FPA 1000 Series / Honeywell Morley Dxe Series / Siemens Cerberus, GST 200 (EN)
Supply Installation Testing Commissioning of addressable Heat Detector wht fixed and rate of raise feature including mounting base with LED etc complete as required. Each detector should have 2 as per NFPA 72 style 7 wiring requirement (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to eletrmagnetic effects in accordance with EFSG agreement EFSG/F/97/005. Detector should monitor electromagnetic interfarence and report to the panel-current and average values, EMC safety for detector shall be 50 V/m. shall be EN54/VDS/U: certification. (Detectors without inbuilt isoaltors may be considered with an additional isolator module per detector Makes :Bosch FPA 1000 Series / Honeywell Morley Dxe Series / Siemens Cerberus, GST 200 (EN)
Supply Installation Testing Commissioning of UL/EN54/LPCB listed and FM approved line isolating for isolation the section of circuit in case of short in the addressable loop wiring Make: - Bosch / Honeywell / Siemens / GST
SITC of intelligent analog addressable type Manual Call point having surface or flush mounting option fully compliant to EN54 having rotary decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Make: - Bosch / Honeywell / Siemens / GST
SITC of addressable Loop powered hooter with strobe complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required complete the job in all respect upto the entire satisfaction of Engineer - in - charge of work. Make: - Bosch / Honeywell / Siemens / GST
SITC of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink sulphate as bare chemical class 1 material PSPA fixed on 3mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener Make GLOLITE / PES / OMEX
Supply Installation Testing Commissioning of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Bosch / Honeywell / Siemens Cerberus / GST
Supply, Installation, Testing and Commissioning of Intelligent Analog Addressable Type Monitor Modules having option of RAIL or Surface Mounting with Tri Color LED status indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Switch from 01-99 dully approved to GEA GEW1-082 conforming to BS5839 Standards and Duly approved by EN54/LPCB/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. Bosch / GST / Honeywell / Siemens
Supply, Installation, Testing and Commissioning of a 16 speaker circuit digital voice alarm controller that supports 16 zones without additional equipment. Direct connection to 16 speaker lines from controller. Monitored emergency Push to Talk paging microphone part of controller. Includes Digital Signal Processor, Audio storage for pre-recorded messages, audio matrix, amplifier monitoring and control, loudspeaker output connection terminals and audio source connection ports for auxiliary inputs. Make Bosch / GST / Honeywell / Siemens
Supply, Installation, Testing and Commissioning of amplifier to be connected directly to controller with standard 100V line. Equipped with Toroidal Transformer, protective circuits, LED Status indicators and speaker output short circuit protection, extensive heat sinking, fan cooling and soft start. With balanced XLR input. - 500 watt. Make Bosch / Henrich / Honeywell
Supply, Installation, Testing and Commissioning of 12W speaker with metal enclosure with Line Matching Transformer and tapping of 6W and 12W. Make Bosch / Henrich / Honeywell
Supply, Installation, Testing and Commissioning of 19` Mounting Rack with required power points suitable for above equipment`s. Make: - Comrack / Volrack / Hive Networks (HN)
Wiring for PA system with the following sizes of FRLS insulated copper conductor single core cables in existing surface/recessed M.S. conduit etc. as complete as required.2 x 1.5 sq.mm (30/0.25mm) Make: - Polycab / Grandlay / Havells / RR
NIT COMPUTERS
Arora Telecommunication
A.S.ENTERPRISES
ASHU TRADING COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .