Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹37.7 L+₹1.6 L (4.42%)Rejected-Finance JOTANKUR TEGHORIJOTEVIRAM PURBA MEDINIPUR | MEDINIPUR EAST | WEST BENGAL | 721627 | L2 | Rejected-Finance HIGHER BID | |
| 3 | L3₹40.5 L+₹4.4 L (12.2%)Rejected-Finance | L3 | Rejected-Finance HIGHER BID | |
| 4 | L4₹42.5 L+₹6.4 L (17.9%)Rejected-Finance | L4 | Rejected-Finance HIGHER BID | |
| 5 | L5₹43.5 L+₹7.4 L (20.5%)Rejected-Finance | L5 | Rejected-Finance HIGHER BID |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
10 Oct 2020, 6:00 pmClosed
GE WEST FEROZEPUR CANTT
GE WEST FEROZEPUR CANTT
SPL REPAIR TO SEWAGE LINE AND MANHOLES AT UNIT AREA 550 ACRE AREA OF 10 MADRAS AND OTHER SANCTIONED WORK UNDER GE WEST FEROZEPUR CANTT
2020_MES_351917_2
802020/GE-47/E8
Open Tender
Civil Works
Works
180 days
FEROZEPUR CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE WEST FEROZEPUR CANTT
₹60,000
Yes
8 Feb 2021
25 Sept 2020
12 Oct 2020
25 Sept 2020
10 Oct 2020
27 Sept 2020
Amount
Excavating in trenchs, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
M&L PCC 1:4:8 (Type D2) using 40 mm graded stone aggregate as in foundation filling and mass concrete.
M&L for TMT bars10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and direceted.
Ditto all as per Item no-4 above but 5mm dia and over upto and including 10 mm dia in stirrups, spacers and binders complete all as specified & directed.
S&F Mild steel TMT bars 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, complete all as directed by Engr-in-charge.
Use and waste of formwork to soffits of floor or roof beams, beam haunching ,grider, bressumber, lintels,cantilever ,sleves including supports ,over hang etc also splay between floor and beams to rough finish surface of concrete flat.
Use and waste of formwork to to rough finished flat surfaces to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified and directed.
M&L for cement concrete design mix M-25 (20 mm graded aggregate) as in beams, cantileveres, bressummers, lintels over 1.50 mtr span and all other similar works complete all as specified and directed.
M&L for cement concrete design mix M-25 (20 mm graded aggregate) for slabs supported on walls, beams and collumns in floors, roofs, landings, balconies, canopies , deck slabs and in the shelves and the like and all other similar works complete all as specified and directed.
Dismantling brickwork of stone/boulder masonry, build incement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
All as per item No-12 here-in -above but except bricks complete all as specified and directed. Note :- Old serivceable bricks obtained from Srl No 11 shall be reused after proper cleaning.
Supply and fix solid PVC door frame of size 50mm x 47mm made out of 5mm single piece extruded PVC profiles reinforced with 19 x 19mm MS square tube provided with EPDM rubber gasket weather seal through out the frame and the profile mitre cut at two corners and joined by inserting 2 nos 150mm long brackets of 15 x 15mm MS square tube inside 19 x 19mm MS square tube suitably screwed complete all as specified.
Supply & fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes of size 15 x 15mm for top and bottom rails and 19 x 19mm for stiles, MS frame covered with 5mm thick single piece extruded PVC profile 'C' channel having a 5mm thick PVC sheet strip of 20mm width struck inside with solvent cement, forming stiles, and 5mm thick single piece extruded PVC profile for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail; panelling of 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with PVC sheet beading, and joined together with solvent cement adhesive etc all as per manufacturer's instructions and drawings as shown in SSR Part-I 2009 complete all as specified.
Material and labour for PCC 1:3:6 type C1(20 mm graded aggregate) as in bed blocks for hold fast and all other similar works including necesssary formwork complete all as specified and directed.
Supply and fixing for mild steel flat iron as in hold fast clamps and all other similar works conforming to Fe 290. Gde -E-165 complete all as specified and directed.
S&F 100 mm butt hinges medium weight cold rolled mild steel complete all as specified and directed.
S&F aluminium anodised 200 mm barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm long aluminium alloy handles,fabricated type, anodised complete all as specified and directed.
S&F vitreous China squatting pan, ' Orissa patteren, size 580 x 440 mm white, with integral footrests (excluding flushing cisteren and flush pipe) complete all as specified and directed.
S & F for vitreous china, bowl urinal flat back, size : 465 x 355 x 265mm white (min) with union and grating for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) incl. providing anf fixing plugs, securing urinal to plugs with and incl, 60 mm long brass screws, pointing around urinal back in cement mortar 1:2 (excl fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed) (Make : Hindware/Parryware.Cera)
S&F vitreous China wash basin white, flat back,size 580X450 mm including cutting for pinning in ends of brackets,complete.
S&F 10 litre capacity PVC low level flushing cistern with all accessories complete fixed with WC including syphone pipe, PVC flushing pipe of size complete all as specified and directed.
S&F in repair angle stop valve of PTMT any colour pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90 gms) complete all as speified and directed.
S&F in repair bib tap fancy type long body of PTMT any colour screwed, for iron pipe and fixed.(Minimum weight 15mm-120 gms) complete all as specified and directed.
S&F in repair pillar tap fancy type of PTMT any colour screwed for iron pipe and fixed (minimum weight 15mm-110 gms) complete all as specified and directed.
S&F in repair towel rail 600 mm long of PTMT fixed with and including chromium plated brass screwsand wooden/plastic cleats (minimum weight 190 gms) complete all as specified and directed.
S&F PVC connection 15mm size PTMT nuts of length 450 mm.
Material and labour 20 mm thick granite (of an type and colour) machine cut as in urinal partitions and all other similar works including grinding, polishing,cutting grooves in wall for fixing granite with cement mortar 1:2 and all other arrangments complete all as specified and directed
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situation
Material and labour for 15 mm thick cement plaster in CM (1:6) on brick work/ RCC wall and finish the surface fair and even without using extra cement complete all as specified and directed.
M&L Rendering 15mm thick in cement mortar 1:4 using intergral water proofing compound on fair faces of brick work to be finished even and smooth(with out using extra cement. complete all as specified and directed. Note: Integral liquid water proofing compound to be used in per bag of cement shall be as per manufacturers instructions and paid separately under respective items.)
M&L for rendering 10mm thick in cement mortar (1:6) on any face of brick walls or concrete surfaces, surfaces finished fair and even complete all as specified.
M&L for 5mm thick rendering in cement mortar (1:3) on concrete surfaces, finished even and smooth without using extra cement as in ceiling complete all as specified.
Supply only integral waterproofing compound
M&L for Preparation of newly plastered surfaces of ceiling & applying three coats of white wash complete all as specified.
M&L for preparation of new plastered wall surfaces and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of two coats of cement based paint over a coat of primer complete all as per manfacturer,s specifications and directed.
M&L Non Skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L glazed tiles digital coloured ceramic tiles 300x450x7mm thick in vertical surfaces such as skirting and dados set and jointed in neat cement slurry pointed in coloured cement to match complete all as specified and directed.
Material and labour Screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes like tiles etc complete all as specified and directed.
Material and labour rendering 10 mm thick on fair faces of brick work in CM (1:4) for receving vertical tiles and all other similar works complete all as specified and directed.
S/F GI tubing 15mm bore medium grade medium grde with all fittings and fixed complete to wall and ceilingor laid in floors complete all as specified and directed
S/F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceilingor laid in floors complete all as specified and directed
M & L for 200 mm bore (internal dia of pipe) salt glazed stoneware drain pipe grade A laid in trenches and jointed complete all as directed.
M & L for 150 mm bore (internal dia of pipe) salt glazed stoneware drain pipe grade A laid in trenches and jointed complete all as directed.
M & L for PCC 1:3:6 type C2, (using 40 mm graded aggragate) as in concrete bed to 200 mm bore drain pipe including packing under and hunching against the sides of pipes after pipe laid and tested complete all as directed.
M & L for PCC 1:3:6 type C2, (using 40 mm graded aggragate) as in concrete bed to 150 mm bore drain pipe including packing under and hunching against the sides of pipes after pipe laid and tested complete all as directed.
M&L for PVC (SWR) multi floor trap in repair with grating including jointing with solvent cement for diameter of 75 mm outlet complete all as directed.
M&L for PVC (SWR) gully trap in repair 125/110 mm, setting and jointing with solvent cement complete all as directed.
S&F 110 mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes laid in trenches complete all as specified and directed.
S&F 110 mm dia PVC (SWR) bends with access doors any radius.
Material and labour for application of bituminous primer conforming to IS-3384 @ 0.20 kg per sqm and applying 3 mm thick APP base polymeric modified membrane reinforced with non woven polyester mat, weight not less than 3.5 Kg per sqm laid by torch application method (LPG Torching method) overlap while torching shall be 100 mm on transverse direction and 75 mm on longitudinal direction and applying bituminous aluminium paint @ 0.15 kg per sqm on top complete including as per manufacturers instructions all as specified and directed by Engineer-in-Charge.
S&F for PVC rotational water tank by providing new rotational moulded polyethelene water storage tank double layered ISI marked (Cylindrical verticle with closed top) hoisted and fixed in position all as directed of capacity 500 ltr including dismantling & taking out old unserviceable item complete. (Make :- Sintex/Polycon/Ashis Plast).
S&F for Gun metal globe or Gate valve with iron wheel screwed both end for iron pipe and fixed as per requirement of site and as directed by Engineer in charge including dismantling and taking out old unserviceable item complete of 25 mm size. (Make - Leader/Zolata/Hindustan).
Supply and fix ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of size 25 mm dia.
S&F Gun metal globe or Gate valve with iron wheel head, screwed both end for iron pipe and fixed as per requirement of site and as directed by engineer in charge including dismantling and taking out old unserviceable item complete fo 20 mm size. (Make :- Leader/Zolata/Hindustan).
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc.
Returning, filling in,including spreading,levelling,watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified & direcetd.
Removing excavated material n exc. 50 mtr and deposting where directed at a level n exc. 1.5 mtr above the starting point complete all as specified and directed.
M&L for Surface dressing n exc 15 cm deep in soft/loose soil complete all as specified and directed.
M&L for Surface dressing n exc 15 cm deep in hard/dense soil complete all as specified and directed.
M&L for Hard core 75 mm thick, using broken bricks of guage n.exc. 63mm, deposited, spread and levelled in layeres n.exc. 15 cm thick, watered and rammed to a true surface, as in below sub base, plinth protection and ramp, complete all as directed by Engr-in- Charge.
M&L for 75mm thick Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base of floors finishes complete all as specified and directed
M&L for fine sand bed under paver block, complete all as directed by Engr-in-charge.
M&L 60mm thick Coloured (Yellow & red) interlocking (M-35) cement concrete tiles with grey cement and pigment of approved design & pattern as approved by GE. Complete all as speciifed and directed.
M&L for rendering 15mm thick in cm 1:4 on fair faces of brick or concrete surfaces, finished even and fair complete all as specified
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil, complete all as direced by Engr-in-Charge.
Excavation in trenches not exc. 1.5 mtr wide and exc. 1.5 mtr but n.exc. 3.00 mtr depth for cesspits, manholes etc. and getting out soft/loose soil even in foul position complete aii as specified and as direcetd.
M&L for form work to sides of concrete foundations, footings, bases of columns and plinth beams and similar work, complete all as directed by Engr-in-Charge.
M&L for RCC type B1, 1: 1.5 :3 (20 mm graded aggregate) as in Foundations, footings, foundation beams; plinth beams; bases for columns, etc.. complete all as directed by Engr-in-Charge.
M&L for form work to sides of columns, square, rectangular, complete all as directed by Engr-in-Charge.
M&L for RCC type B1, 1: 1.5 :3 (20 mm graded aggregate) as in column etc. complete all as directed by Engr-in-Charge.
M&L for RCC type B1, 1: 1.5 :3 (20 mm graded aggregate) as in lintel beams, roof beams, cantilevers etc. complete all as directed by Engr-in-Charge.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide. complete all as directed by Engg-in charge.
M&L for RCC type B1, 1:1.5 :3 (20 mm graded aggregate) as in slab supported on walls, beams and columns in roofs etc. complete all as directed by Engr-in-Charge.
M&L for 10 mm thick (average) screeding on concrete surfaces in cement mortar 1:4, in order to maintain proper slope, add WPC @3% of cement weight(WPC paid separately), finished even and smooth without using extra cement complete all as specified and as directed.
M&L for Polymer modified bituminous membrane with sand witched polythene film/non woven polyster reinforcement /polymeric water proofing membrane weighing minimum 3Kg/sqm ( make : IWL/STP/ HYPERPLAST or equivalent ) laid after Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (i.e roof slab cleaned throughly to remove all loose particle dust/dirt particle ) membrane shall be laid over entire roof surface and on verticle surface up to grooves ( or as per manufacturers recommendation) with over laps of 100mm The over lap shall be sealed by flames or as per manufacturer instruction.Hot blown bitumen grade 85/25 @1.2kg/Sqm applied over the membrane should be compatible with membrane all as recommendation manufacturers and all as specified and directed.
M&L for prepration of roof surface and applying two coat of solar reflective bituminous aluminium paint @0.10 Kg/Sqm over bituminious membrane complete all as specified and directed by Engr-in-Charge.
M&L for Moorum/red bajri filling in floors or pavings, laid in layeres n.exc. 15 cm thick, spread, levelled and reammed including watering, complete all as directed by Engr-in- Charge.
Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in plinth protection, 50mm thick, surfaces finished even and fair without using extra cement as in plinth protection including provision of construction joints complete all as directed by Engr-in-Charge and as specified.(Note : Construction joint will be measured and paid seperately)
M&L for Forming Construction joint 30mm deep x 10mm wide filled with sealing compound complete all as directed and specified by Engr-in-Charge.
M&L for PCC 100 mm thick, type D-2, 1:4:8 (40mm graded aggregate) as in sub-base, complete all as directed.
M&L 50 mm thick PCC, type B-1, 1:2:4 (20mm graded aggregate) as in flooring, surface finished even and smooth without using extra cement complete all as directed.
S&F for 38mm wide Aluminium dividing strips, 1.5mm thick, inserted in position, conform to design complete all as specified and directed.
Cutting into existing manhole for connecting new drain, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC1:2:4 type B1, smooth finished and reforming benching as required for internal pipe of dia 200 mm complete all as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for & forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished and reforming branching as required for 150 mm dia pipes
M&L for cement concrete type B2 1:2:4 (20mm graded aggregate) in surface channels and drains etc complete all as specified and directed
Providing cement concrete 1:2:4 type C1 (20mm graded agg) in win- dow or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, ier aps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces,E28 including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match complete all as specified and directed by EIC
M/L RCC 1:2:4 type B1 using 20mm graded aggregate as in Precast cover slab , shelves and similar articles and setting in mortarcomplete with joints to match complete all as directed.
M&L for reinforced cement concrete nominal mix Type B1 1:2:4 (20 mm graded aggregate) in coulmns, pillars,piers, posts and struts and all other similar works complete all as specified and directed.
M&L for reinforced cement concrete nominal mix Type B1 1:2:4 (20 mm graded aggregate) foundations, including rafts, footings, foundation beams,plinth beams,bases for coulmns etc and all other similar works complete all as specified and directed.
M& L for dark shade Vitrified Ceramic tiles 10 mm thick (Square/rectangular) polished area of each tile not exceeding 0.36 sqm in dados/wall cladding set and jointed in neat cement slurry and pointed in white or coloured cemeent to match over rendering 10 mm thick on fair faces of brick work in CM (1:4) complete all as specified and direcetd.
S&F 0.63 mm thick mild steel , plain, black sheet in wall cladding, stell gates and similar work, cut to size holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams including bending or turning up, mitered angles, etc as required complete all as specified and directed.
S&F golden powder coated stainless steel letter of size 20 mm width and height 150 mm in ENGLISH font as specified fixed on flag mast granite stone with necessary fixing arrangement complete all as directed.
S&F framed work as in sliding / side hung gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (inclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in any type of soil.
M & L PCC 1:3:6 type C-2 (40mm graded aggt) as in foundation filling & mass concrete
S&F Rolled sections as in steel post (tubular pipe medium grade) , main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates of Fe 410-W(Gde E-250) including notching, drilling, fitting, riveting, welding where required or connecting with bolt and nuts complete all as specified and directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes with riveted, bolted or welded attachment
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm and n exc 10cm long of 16 to 20 mm dia neck complete all as specified and directed
M&L for preparation of new steel surafces of any description not otherwise described , over 10 cm width or girth , priming with a coat of red oxide primer and applyinng 2 coats of synthetic enamel complete all as directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. FE 410W(Gde E-250) quality
S&F 0.60mm thick Galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with coach screws and washers, in roofs, walls etc with grade of zinc coating 120gm/sqm.
S&F 0.60mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of Zinc coating 120gm/sqm
S&F wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165
Cleaning and removal of foreign material from inside the Gully trap including removing & re-covering of RCC/CI cover and directly buried in the ground to a distance not exc. 50 m along with spreading of bleaching powder complete all as specified and directed.
Cleaning of existing manhole of any size including removing & re-covering of RCC/CI cover of depth not exc 1.5 mtr by bailing out water/sewage by mechanical pump or manually including mouth of sewage line and removing the deposited residual sludge/debries to a distance not exc. 50 mtr and buried in the ground complete including cleaning sewage line by rodding manhole to manhole complete all as diercted.
Cleaning of existing manhole of any size including removing & re-covering of RCC/CI cover of depth exc 1.5 but n. exc 3.00 mtr by bailing out water/sewage by mechanical pump or manually including mouth of sewage line and removing the deposited residual sludge/debries to a distance not exc. 50 mtr and buried in the ground complete including cleaning sewage line by rodding manhole to manhole complete all as diercted.
Taking down cement plaster from inside/outside of existing septic tank/manhole/walls etc including racking out joints, hacking for key scrubbing down with water and removal of rubbish off the premises complete all as directed.
Demolition and breaking of drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia 200 mm complete all as directed.
Demolition and breaking of drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia 150 mm complete all as directed.
Providing cement concrete type B1 1:2:4 (20 mm graded aggregate) as in copings to brick wall, kneelers,bedplates and all other similar works including necessary form work complete all as specified and directed.
Demolition of cement cocrete (unreinforced) not exceeding 15 cm thickness (above or below ground level) complete all as directed.
Demoletion of reinforced cement concrete (reinforcement cut as required to facilitate demoletionof any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for RCC(1:2:4), type B1 (using 20 mm graded stone aggregate) precast cement concrete cover slab for manhole and similar article with plain face, set in cement mortar 1:4 complete all as specified and direceted.
Cleaning of sewage pipe lines of dia exc 100mm and not exc. 250mm systematically by passing/rodding ropes,knots,bamboo/wire/kandi, rotary cleaning rods complete all as specified and directed.
M&L for machine cut kota stone in risers of steps,skirting and dado 20-25 mm thick over cement plaster 10 mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to mirror finish complete all as specified and directed.
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and rubbish off the primises complete all as directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons,dados etc laid, bedded and pointed in any mortar and removal of rubbish off the site complete all as specified & directed.
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid 15 mm thick in cm 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to mirror finish complete all as specified and directed.
M &L Point wiring complete with 1100 volts grade PVC insulated unsheathed FRLS cable of copper conductor , multi stranded of size 1.5 sqmm, single core, in and including rigid non-metallic PVC conealed conduit, medium grade of suitable size (not less than 25mm dia) duly ISI marked with all accessories such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and sketch fittings etc) and new MS pressed steel / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire of size 1.5 sqmm unsheated stranded copper conductor with greenFRLS PVC insulation connected to common earth dolly complete all as specified and directed for the followings :-(a) One light/fan point controlled by one single pole one way 5 amps switch.
S & F Switch piano flush type 5 amps, single pole one way duly ISI marked.
S & F Ceiling rose surface type, bakelite 65 x 50mm, 2 to 3 terminals duly ISI marked.
S & F Lamp holder insulated body threaded dome pattern,suitable for bracket / batten fitting complete all as specified including 10W LED lamp.
Supply & Fixing LED tube light fitting 18 Watts,4 feet long decorative ultra slim linear LED lighting fixture with extruded polycarbonate,environmental friendly, energy efficient 230V, complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Cat Part no. LCTL-18-CDL of Crompton or LHEXBXPNIW020 of Havells or equivalent Bajaj/Phillips
S & F LED Security light fitting 1 X 30 watts with bracket (for housing security light fittings) made of GI pipe light grade suitable size duly cutted and welded at an angle of 120 degree and fixed to wall with suitable MS clamps - bolts,nuts,and washers complete all as specified and directed. Cat Part no. LSTP-45-CDL of Crompton or ENDURAPEARNEOSL45WLED757PASYTOPC of Havells or equivalent Bajaj/Phillips
S & F sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired SPN DBs fitted ACRYLIC window 240 volts 200 Amps rated enameled bus bar 4 way dust and vermin proof ssuitable for incorporation of MCBs duly concealed in wal and making good to distrubed surface and colour matching complete all as specified.
S & F MCB single pole neutral 240 volts, 40 Amps, 10 KA complete all as specified.
S & F MCB single pole 240 volts, 40 Amps, 10 KA braking capacity complete all as specified.
Suplying and fixing 1100 volts grade heavy duty10 Sq mm two core cable PVC insulated aluminium conductor, served with inner shething of PVC sheeathed in service conections suspended by insulating hangers not more than I metre apart including 4Sq mm suspension wire, one twin core cable flat or circular
M/s S B Construction Company
HAPPY ELECTRICALS
M/S M H Builders
AKASH ELECTRICALS
Dee Kay EnterPrises
Harmesh Kumar Sharma and Sons
M/s Surjit Singh and bros
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .