Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC 10 A FRIENDS COLONY PATIALA 147001 | PATIALA | PUNJAB | 147001 | L1 | Accepted-AOC Accepted L-1 Bidder |
Tender Value
₹5.8 L
EMD Value
₹11,700
Closing Date
27 Jul 2021, 5:00 pmClosed
Executive Engineer
EE WSS DIVN. No. 1 Amritsar
Providing Improved access to water through Household Connection in existing Water Supply Scheme Kandowali Block Harsha Chhina Distt. Amritsar. UNDER JJM NABARD XXVI
2021_WSS_66862_1
Kandowali letter no.3012 dated 10-06-2021
Open Tender
Civil Works
Item Wise
90 days
Amritsar
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
₹11,700
12 Nov 2021
14 Jun 2021
28 Jul 2021
14 Jun 2021
27 Jul 2021
14 Jun 2021
Amount
Cost of Submersible Cable 4mm Complete in all respects
Cost of Replacement of Control Panel consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. (reputed make) complete in all respects as per standard Specifications.
Repair of Pump Chamber
Supplying & fixing glass panes including special metal sash putty of approved make.
Repair of Plaster inside and outside the pump chamber complete in all respects.
Repair of pump chamber plinth protection complete in all respects
Kiln seasonal Hollock wood cup board chowkats including iron hold fasts, iron hinges corner straps, wooden knobs or handles fixed in position (Size 45 x 60mm). (a) 30mm thick Cup Board
White washing 3 coats inside of pump chamber. Complete in all respects
RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts (socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16/20Amp. universal sockets (6Module Box), 6/16/20Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring fan point without fan box
Wiring light point
Wiring 6 Amp. Plug control comprising wall socket point.
Wiring 16/20 amp. power plug control point.
REPAIR OF OHSR
Repair of Expansion joint at 6th Brace including shuttering & Centering Complete in all respects.
100mm dia
150mm dia
Providing & fixing Manhole Cover Size MS 560mmx560mm manhole cover and made of 50x50x8mm angle frame fitted with MS sheet hinged cover of 6 mm thickness, Jali, Gauge 15cm width & lightning conductor of GI 7/10” SWG (10mm) dia. standard wire with lightning rod of 25mm. Dia 0.9 m. Long with earth electrode 25mm dia. 2.75mtrs. long GI pipe from ground level connecting 50mm dia 1.40 m long perforated GI pipe including fixing of clamps as per IS:2309-1969 Complete in all respects.
Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B-Class Including cost of specials (such as Tees, bends, sockets, elbows etc.) painting with anti corrosive bitumastic paint, testing, cutting threading inside building/railing for staircase (OHSR) (15mm i/d)
Providing & fixing of OHSR ladder from parapet to top of OHSR complete in all respects.
REPAIR OF WATER WORKS
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing.
Construction of masonry Corner pillar including cost of cement pointing as per standard drawing & Analysis of Rates complete in all respects.
Providing & Fixing D hook complete with MS bolt size 300 mm x18 mm as per standard drawing D-7 & Analysis of Rates A-9 complete in all respects.
Construction of foot paths with masonry toe wall& earth filling & concrete topping; inside water works as per standard drawing D-10 & Analysis of Rates A-11 complete in all respects.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) 150mm dia
Providing & Installing Testing & Commissioning of One No. Electrically driven diaphragm opreated metering system chemical dosing chlorinator suitable for for delivering 0.5 to 6 liters of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg/cm2 and suction left not less than 1.5 mtr., as per DWSS standard specifations.
Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects.
Providing and fixing in position CI Bib Cock(tap)(15 mm i/d)as per IS:210 with stainless steel spindle of approved make and Fixng of Nozzle to contro flow of water(to the approval of Enginer-in-charge Complete in all respect
Repair of pipe line for leakage complete in respect.
90 mm o/d PVC Pipe
110 mm o/d PVC Pipe
Providing proposed water connections to household up to wall with providing ,laying, jointing, fixing, testing MDPE pipe line 15 mm i/d = 2.00 mtr(Below GL) and ISI Marked G.I. Pipe 15 mm i/d (As per IS 1239) B-Class approved make = 2.50 mtr (Above GL) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground and ISI marked 15 mm i/d GM Ferrule as per IS:2692 and 3" i/d clamp with CI Bib Cock 15 mm i/d as per IS:210 with stainless steel spindle of approved make complete in all respects. (Connection at Existing pipe line)
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) 100mm I/d
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department 6 No. With each of Size 0.9m x 0.9m complete in all respects
MS Sign board painting & printing complete as per standard size of DWSS complete in all respects
Carriage of Sand & Bajri 6.2. 6.4 & 11
Credit for Old Control Panel (-)
CONDITIONS :-
Item for which no rate or price has been entered in will not be paid for the Employer when execut6ed and shall be deemed covered by the other rates and prices in the Bill of Quantities.
Unit rates and prices shall be quated by the bidder in indian ruppees.
Where there is a discrepancy between the rate in figures and words, the rates in words will govern.
Where there is a discrepancy between the rate and the line total resulting from muluplying the unit rate by quantity the unit rate quoted shall govern.
Any item of work not included in the above contract schedule of rates and got done at the site of work; the same will be paid according to CSR-2010 subject to the premium or discount tendered by the contractor. In the case of non-schedule items, the decision of the Engineer-in-charge will be final and binding upon the contractor. In case any item which is a part of lump-sum rate is be deducted @CSR rates + Ceiling premium prevailing on the date of tender
The work will be carried out in accordance with PWD Book of specifications - 1963 edition with upto date amendments.
Approximate quantities are given in the contract schedule of rates and these can vary at the time of execution of the work. The payment will be made according to the actual work done by the contractor.
All amendments issued on the common schedule of rates 2010. up to the date of opening of tenders will be applicable on the contract schedule of rates.
Contractor should clearly quote his rates in figures & words. Conditional tender will be rejected.
All items and rates provided in the DNIT are subject to the footnotes give in CSR-2010
The Engineer-in-charge will have full powers to change the layout of the work covered in this contract if considered necessary.
No claim will be entertained form the contractor in case, any mistake in description rates or unit occurs in any item taken in this schedule while preparing this DNIT or on account of typing or comparison or over writing. The same will be rectified at any time as per common schedule of rates 2010 along with upto date amendments.
The arrangements of bricks at site of work would be done by the contractor at his own level from his own source.
For any other non-schedule items, the contractor will submit through Engineer-in-charge, the analysis of rates in triplicate based on purchased vouchers. A margin of 10% shall be allowed for material components and 21.5% on labour components and contractor shall produce photo stat copies of the purchase vouchers in support of his claim. The decision of the Engineer-in-charge/Competent authority in the matter shall be final and binding on the contractor.
All the extra items will be got approved from the competent authority and no premium will be allowed on non schedule item
Pavement for the carriage of material shall be paid as per the rates quoted by the tenderer.
Time period allowed for completion of work in 3 months.
If contractor allowed for completion of work within 7 days from the date of allotment, DWSS reserve the right to impose penalty or withdraw the work and propose action for debarring in future tendering or both; decision of Chief Engineer (North) shall be binding.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .