| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹26.4 L+₹96,005.13 (3.78%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹27.2 L+₹1.8 L (7.13%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹27.4 L+₹2.0 L (7.76%)Rejected-AOC 06 GOVIND NAGAR PANCHAYAT USR TRANSPORT CAMPBELL BAY OLD FISHERMAN COLONY CAMPBELL BAY GREAT NICOBAR ISLANDS | L4 | Rejected-AOC Rejected |
Tender Value
₹24.3 L
EMD Value
₹48,500
Closing Date
24 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) Campbell Bay
GE (I) Campbell Bay, Army Land, Great Nicobar-744302
PROVN OF GUARD ROOM ALONGWITH ATT TOILET AND BATHROOM AT REAR GATE, ARMY LAND CAMPBELL BAY
2022_MES_522678_4
8775
Open Tender
Civil Works
Works
180 days
GE (I) Campbell Bay
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
Yes
GE (I) Campbell Bay
₹48,500
28 Nov 2022
3 Aug 2022
26 Aug 2022
4 Aug 2022
24 Aug 2022
10 Aug 2022
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as directed.
Rough excavation not exceeding 1.5m deep and getting out in hard/dense soil complete all as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep in any type of soil for foundation etc. or for shaffts, walls, cesspits, manholes, pier holes etc n. exc 10 Sqm on plain and n.exc 1.5m in depth and getting out complete all as specified.
Ditto all as per item No.2 above but depth exceeding 1.5 m and n.exceeding 3 m complete all as specified and as directed by the Engineer-in-Charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified.
Removing excavated material from site to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
M & L Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sided and soffits (if any) of foundation and plinth beams; and similar work; vertical or to better rough finished flat surface of concrete completed all as specified and as directed
M & L formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular finishes rough surfaces of concrete.etc finished rough surfaces of concrete complete all as specified.
Use and waste form work to sides and soffits of floor or roof beams, beam hunching girders, bressulters, lintels, cantilevers, shelves including supports over hankes etc. of plinth/roof beam and similar works vetical or better with rough finished surface of concrete flat completed all as specified and as directed
Use and waste of form work to edges of concrete flats, breaks in floors, opening in concrete walls, floor and roofs and side of RCC/PCC bands in walls, horizontal or sloping and similar work all n.exc 20 cm wide for rough finished surfaces of concrete complete all as specified and as directed.
M&L for form work to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed.
M & L Reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded aggregate in foundations, including rafts, footings, plinth beams, bases for columns, etc. basement slabs, under ramed piles and mass concrete complete all as specified and as directed. (Note:- Reinforcement and form work will be measured and paid separately)
M & L Reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded stone aggregate in columns, pillars, piers and struts, posts etc. complete all as specified and as directed. (Note:- Reinforcement and form work will be measured and paid separately)
M & L Reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded aggregate in beams, cantilivers, lintels over 1.5 mtr span complete all as specified and as directed. (Note:- Reinforcement and form work will be measured and paid separately)
M & L Reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded aggregate in chajjas,complete all as specified and as directed. (Note:- Reinforcement and form work will be measured and paid separately)
M&L TMT bars 10mm dia and over, as reinforcement. cut to length, bent to shape required including crancking bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified.
M&L TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, cut to length , bent to shape required inluding cranking bending hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia or securing with clips complete all as specified.
M&L Moorum/red bajri filling in floors or pavings, including spreading, leveling, watering and well ramming in layers not exceeding15 cm thick complete all as specified.
M & L for treating the backfill in contact with the foundation at the rate of 7.5 Ltrs of anti termite emulsion per Sqm of vertical surface complete all as specified and as directed.
M&L for treating the top surface of filled earth @ 5 ltrs of emulsion per Sqm of surface area complete all as specified and as directed.
M&L for treating the soil under plinth protection @ 5 ltrs of emulsion per Sqm of surface area complete all as specified and as directed.
M&L for treating the soil along with external perimeter of building @ 2.25 ltrs of emulsion per metre of the perimeter wall all as specified and as directed.
M&L precast cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate as in block masonry with solid blocks exceeding 10cm in width and set in cement mortar 1:6 complete all as specified.
M&L precast cement concrete solid building blocks or slabs 10cm thick of PCC 1:3:6 type C-1 using 20mm graded stone aggregate ( With plain or interlocking joints as directed )and set in cement mortar 1:4 complete all as specified.
S & F Rolled sections as in main and cross beams,hip and jack rafters,purlin where connected to common rafters and running rails and guides for sliding doors,fixed with angle cleats or other connecting plates conforming Fe-410W (Gde-E-250) quality -A complete all as specified and as directed
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
M&L hard core of broken stone or boulders of guage n.exc 63mm deposited, spread, levelled in layers n.exc 15mm thick watered and well rammed to true surface complete all as specified and as directed.
M&L for 75mm thick PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in sub base for flooring complete all as specified and as directed by the Engineer- in-Charge.
M&L for rendering 10mm thick with CM 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L 15 mm thick rendering on fair faces of brick/concrete surfaces in cement mortar 1:4 in two layers of 10mm thick and 5mm thick, finished fair and even and water proofing compound shall be added on top layer as per manufacturer instruction complete all as specified. (Note :- WPC will be measured and paid separtely under approprite item as supply only).
Supply only integral water proofing conforming to IS-2645-2003 complete all as specified.
M&L non skid ceramic joint free tiles (coloured) 7 to 8mm thick, area of each tile exceeding. 0.11 but not exceeding 0.18 Sqm (1st quality) conforming to IS-13755 as in floor set and joint in cement slurry, jointed & pointed in white or coloured cement to match laid over 15mm thick screed bed in CM 1:6 over 25 mm thick PCC screed 1:2:4 type B-0 using 12.5 mm graded stone aggregate complete all as specified.
All as per item No.33 above but on vertical surfaces as in skirtings over 10 mm thick rendering in CM 1:4 etc. complete all as specified and as directed by the Engineer-in-Charge.
M&L non skid ceramic tiles (coloured) 7 to 8mm thick, area of each tile exceeding. 0.06 but not exceeding 0.11Sqm (1st quality) conforming to IS-13755 as in floor set and joint in cement slurry, jointed & pointed in white or coloured cement to match laid over 15mm thick screed bed in CM 1:6 over 25 mm thick PCC screed 1:2:4 type B-0 using 12.5 mm graded stone aggregate complete all as specified.
S&F glazed ceramic coloured tiles of size 350x250x7mm/450X 350X 7mm thick in vertical surfaces of wall conforming to IS-13712 grade B-III set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed layer 10 mm thick in cement mortar 1:4 finished even and rough for receiving tiles on vertical surface complete all as specified.
M&L 75 mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection and paving finishing concrete surface even and smooth without using extra cement including necessary construction joint 6 mm wide grooves to full depth at 2 to 3 m interval and at every change of direction and filling the grooves with mixture of bitumenand sand mixed in the ratio of 1:3 by weight complete all as specified.
M & L 4mm thick desiner non asbestos fibre Cement building boards fixed or laid / inserted to GI /Aluminium frame work in ceilings including Anodised aluminium snap grid frame work of size 605 x 605 mm for false ceiling,suspended with hangers complete all as specified and as directed.
M&L preparation of new or previously untreated steel surfaces of any description, not exc. 10cm in width or girth and applying two coats of synthetic enamel paint over a priming coat of red oxide zinc chrome primer complete all as specified and directed by the Engineer-in-Charge.
M&L for preparation of new plastered surfaces on wall and applying two coats of oil emulsion,distemper white or tinted over alkali resistant primer complete all as specified and as directed.
M & L applying two coats of cement based paint over a priming coat on newly plastered or unplastered wall surface including preparation of surfaces complete all as specified and as directed.
M&L for anodised powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified (minimum thickness of powder coating 50 micron) complete all as specified and as directed by the Engineer-in-Charge.
S & F powder coated anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 02 Nos in each door, hinges anodised aluminium snap beading, screws etc (thickness of powder coating not less than 50 micron) complete all as specified and as directed. Make : INDAL/HINDALCO/JINDAL or equivalent as per IS
S&F anodised powder coated aluminium window and ventilator shutters, sliding type without sash bars, aluminium sections including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws and suitable anodised aluminium handles and rollers complete all as specified (minimum thickness of powder coating 50 micron) complete all as specified and as directed by the Engineer-in-Charge.
S&F 5.5 mm thick sheet glass, ordinary quality and glazing with aluminium doors / partitions. complete all as specified and as directed by the Engineer-in-Charge.
S&F 4 mm thick sheet glass, ordinary quality and glazing with aluminium windows. complete all as specified and as directed by the Engineer-in-Charge.
M&L 12 mm thick prelaminated particle board,exterior grade, prelaminated both sides with decorative choice laminations fixed to aluminium doors / partitions all as specified and as directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
S&F solid core PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, in opening as per specification complete all as specified.
S&F 30mm thick (style) factory made solid panel PVC door shutter consisting of frame made out of MS tubes for top & bottom rails & MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail & panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per complete all as specified.
S & F 100mm size aluminium butt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised type C-21 complete all as specified and directed
S&F 150mm size aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed by the Engineer-in-Charge.
S&F 150mm long extruded aluminium alloy handles, cast type, anodised complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs vitreous China wash down water closet pan EWC (Pedestal pattern) white 'P' trap including 10 lit capacity pvc valveless,syphonic action type flushing systern,cover for water closet black, closed pattern with bottom with mild steel chromium plated or aluminised hinge device including flush pipe complete all as specified and as directed.
S&F in repairs, wash hand basin of size 550x400 vitreous China (flat back or angle back type) including half pedestal and cutting for and pinning in ends of brackets or erecting stand including supply and fixing of waste coupling, waste pipe etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F 15mm dia. chromium plated pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified.
Supply and Laying of 25 mm outer dia. CPVC pipes SDR 11& Plain CPVC SDR 11 Fittings on wall/ceiling or laying in floors incl taking down of existing plumbing lines etc. complete all as specified and as directed by the Engineer-in-Charge.
Supply and Laying of 20mm outer dia. CPVC pipes SDR 11& Plain CPVC SDR 11 Fittings on wall/ceiling or laying in floors incl taking down of existing plumbing lines etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F stop valves, 20mm dia chromium plated ,fancy tpye,cast copper alloy, screwed down, high pressure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified
S&F stop valves, 15mm dia chromium plated ,fancy tpye,cast copper alloy, screwed down, high pressure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified
S&F Bib taps 15mm dia. fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC (SWR) multi floor trap 75mm dia.plain with grating including jointing with solvent cement complete all as specified and directed by the Engineer-in-Charge.
S&F PVC (SWR) pipes 110mm dia. single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC (SWR) pipes 75mm dia. single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm dia. PVC (SWR) plain bends any radius with access door complete all as specified and directed by the Engineer-in-Charge.
S&F 110mm dia. PVC (SWR) junction single (Single T) equal or unequal provided with access door complete all as specified and directed by the Engineer-in-Charge.
S&F 75mm dia. PVC (SWR) plain bends any radius with access door complete all as specified and directed by the Engineer-in-Charge.
S&F PVC (SWR) vent cowls 110mm dia. complete all as specified and as directed by the Engineer-in-Charge.
S&F Tubular towel rail 20mm dia 'D' type, Aluminium anodised 60 cm long between flanges complete all as specified.
S & F rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top ) (conforming to IS 12701-1996) multi layer hoisted and fixed in position 1000 ltrs capacity complete all as specified in SSR Part I .
S&F ball brass valve high pressure conforming to IS 1703 with polythene float and flynut complete screwed for 20mm dia iron pipe or brass ferrule and fixed complete all as directed.
M&L precast Reinforcecd Cement Concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in landings, cover slab,chajjas etc.and similar articles with plain faces set in CM 1:4complete all as specified and as directed (Note:- Reinforcement shal be measured and paid separately under relevant item)
Material labour for point wiring complete with 1.5 Sqmm PVC insulated unsheathed single core multistranded FRLS copper conductor ,ISI marked,1100 V grade (separate wire for phase and netural for each circuit from DB) drawn through in and including 20 mm dia PVC conduit includign all pvc conduit fittings for concealed wiring and terminated to MS box of 1.6 mm thick including cutting chases,holes for conduits and sinking's for boxes,DBs and making good disturbed surfaces to walls, floors etc and 3 mm hylum sheet for mounting switches, swtich sockets combination, regulator etc including 1.5 Sqmm PVC insulated FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly for light/ fan point/ three pin 5 Amp including all necessary screws,clamps & misc items complete all as directed by Engr-in-Charge. a)One light point controlled by one way 6 Amps swtich make for item no. 76 to 79:- Copper cable: Finolex/Polycab/Havells or its techno commercial equivalent ISI marked make duly approved by GE.
(b) One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator
(c)One 3 pin socket out controlled by one way 6 Amps swtich on independent board
Material labour for point wiring complete with 2.5 Sqmm PVC insulated unsheathed single core multistranded FRLS copper conductor,ISI marked, 1100 V grade (separate wire for phase and netural for each circuit from DB) drawn through in and including 25 mm dia PVC conduit includign all pvc conduit fittings for concealed wiring and terminated to MS box of 1.6 mm thick including cutting chases,holes for conduits and sinking's for boxes,DBs and making good disturbed surfaces to walls, floors etc and 3 mm hylum sheet for mounting switches, swtich sockets combination, regulator etc including 2.5 Sqmm PVC insulated FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly for power point including all necessary screws,clamps & misc items complete all as directed by Engr-in-Charge.
S&F Switch piano, single pole, one way 6 Amp including necessary screws,clamps etc Make for item no.80 to 84: Anchor/maru/leader or its techno commercial equivalent ISI marked make duly approved by GE.
S&F switch socket combination 5 Amps 3/5 pin including necessary screws,clamps etc
Supply & Fix Ceiling rose PVC/ Polycarbonate insulated body with three terminals complete all as directed
S&F switch socket combination 5/15 Amps 3/5 pin including necessary screws,clamps etc
S&Fceiling fan regulator step type,220v,50hZ,Ac including all necessary screws,clamps etc
Supply and fixing,LED light fitting of capacity not less than 20W,minimum lumens 90 lumens/watt,4feet length,compatible for mounted on wall/ceiling/surface, 220V,AC,50Hz, minimum PF 0.9 comprising of decorative box type batten(Compitable for T-5/T-8 LED tubes) ,bipin holders,LED tube light with integrated electronic driver, holder,internal wiring connecting up with twin core flexible copper conductor cable of suitable size drawn though flexible pvc conduit suitable size from ceiling rose complete all as directed by Engr-in-Charge. Make for item no. 85 & 86: CG/Havells/wipro/Bajaj/Philips or its techno commercial equivalent ISI marked make duly approved by GE.
Supply and fixing, LED light fitting of capacity not less than 9W,minimum lumens 90 lumens/watt,2feet length,compatible for mounted on wall/ceiling/surface, 220V,AC,50Hz,minimum PF 0.9 comprising of decorative box type batten(Compitable for T-5/T-8 LED tubes) ,bipin holders,LED tube light with integrated electronic driver, holder,internal wiring connecting up with twin core flexible copper conductor cable of suitable size drawn though flexible pvc conduit suitable size from ceiling rose complete all as directed by Engr-in-Charge.
S&F sheet metal enclosure MCB DB SPN double door type AC 240 V 8 way with 200 Amps rated bus bar,SPN as incomer flush to wall/surface including lugging,screws,clamps and necessary electrical connections,civil works and making good disturbed surfaces complete all as directed by Engr-in-charge. Make for item no. 87 to 89: L&T/havells/Standard/Siemens or its techno commercial equivalent ISI marked make duly approved by GE.
S&F MCB 'C' curve single pole 5 to 32 Amps complete all as directed by Engr-in-charge
S&F MCB 'C' curve SPN 240 Volts 40 Amps complete all as directed by Engr-in-charge
Supply & fixing of heavy duty exhaust fan,A.C, single phase,50Hz, 230/240 V of size 300 mm sweep, with minimum 1350 rpm with louvres, and wire mesh for suitable size to be fixed before fixing of louvers,including necessary wiring along with necessary accessories and neccsary civil works alongwith making good disturbed surfaces etc, complete all as specified and directed by Engr-in-Charge. make: CG/Havells/Almondrod or its techno commercial equivalent ISI marked make duly approved by GE.
Supply and fixing of Energy efficient 5 Star Rating,BLDC motor ,dust proof,Ceiling Fan 1200 mm Sweep size,copper winding with minimum air delivery of 210 cu.mtr/min,A.C, single phase, 220 volt 50 Hz including canopy reel , fliexible copper conductor fixing with necessary lugs drawn through flexible pvc conduit from ceiling rose,including necessary hook, rubber bush&safety pin all necessary accessories complete all as directed by Engr-in-charge. Make: CG/Havells/Bajaj/Atomberg or its techno commercial equivalent ISI marked make duly approved by GE.
Supply,test,laying & commissioning of XLPE insulated, armoured (heavy duty) electric cable with aluminium stranded conductor, 1100 volts grade, 2 core 10 sqmm laid in trenches / duct/ fixed to wall with suitable size clamps / passing through pipe/Tunnel/under ground/surface up to the termination point(as directed by Engr-in-Charge) and cable end terminations crimped with suitable size cable lugs, cable glands with tool,nuts,bolts etc and connecting end terminations to DBs/LT panel/Busbar etc complete all as specified and directed by Engr-in-Charge :- make: Polycab/Havells/Gloster or its techno commercial equivalent ISI marked make duly approved by GE.
M & L for addition alteration in old existing line of CI/GI pipe,inserting tee compitable for existing original size of pipe line, screwing, cutting, threading fixing of valve, attend the minor work regarding pipe line as per directed by Engr-in-Charge.
Supplying, laying or fixing, GI water tubing 25 mm bore, medium grade, of size as shown below confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, etc laid in tenches / floors or fixed to walls / ceiling / roof etc including testing GI tubing with fittings / connections, in trenches / celiling /walls/roofs etc complete all as specified and as directed :- Make: Tata/Jindal/Suryapraaksh/Bansal or its techno commercial equivalent ISI marked make duly approved by GE.
S&F Forged brass ball gate valve, with screwed both ends for iron pipe 25mm borel complete all as specified. Make: Zoloto/Neta/Zenith or its techno commercial equivalent ISI marked make duly approved by GE.
S&F for HDPE double wall corrugated pipes conforming to IS-14930 Part-II with IP Protection of IP-67 having outer dia 50 mm and inner dia of 38 mm with necessary couplers, bends etc for protection of LT cable all as specified and directed.
M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanized iron earth wire 4 mm dia, by means of nuts, bolts, check nuts and washer etc of galvanized iron and earth lead protected by provision of GI pipe medium grade 15mm bore from earth electrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed.
Govinda Swamy Construction
MAHESWARI CONSTRUCTIONS
USR Transport
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .