Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAdmitted-Finance | ₹23.2 L | L1 | Admitted-Finance |
| 2 | L2₹23.9 L+₹70,950 (3.05%)Admitted-Finance | ₹23.9 L+₹70,950 (3.05%) | L2 | Admitted-Finance |
| 3 | L3₹24.7 L+₹1.4 L (6.22%)Admitted-Finance | ₹24.7 L+₹1.4 L (6.22%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | P.S. ENTERPRISES L2 | GOPI ENTERPRISES L1 | SIDDHI ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00Safe Loading, Carriage & unloading of following Materials from Centre Store to Pit Site/J.E. Dump Store. | ||||||
| 1.01 | a- Line Material | 15 | Qtl. | 300 ₹4,500 | 220 ₹3,300 Lowest | 310 ₹4,650 |
| 1.02 | b- PCC Pole 8.5/9 Mtr. Long. | 150 | Nos. | 520 ₹78,000 | 495 ₹74,250 Lowest | 515 ₹77,250 |
| 1.03 | c- ST Pole 11/9 Mtr. Long | 50 | Nos. | 600 ₹30,000 | 550 ₹27,500 Lowest | 610 ₹30,500 |
| 2.00 | Repairing of damage/rusted steel tubular pole by digging of pit up to 2 for proper position, putting 3 Nos angle from of size 35x35x6mm, 3 long properly welding on 3 circle with pole than grouting and plinthing 300 mm above level with cement concrete and sand and bricks ballast. (All material, labour and T&P will be provided by the contractor) | 50 | Nos. | 3,100 ₹1,55,000 | 3,000 ₹1,50,000 Lowest | 3,120 ₹1,56,000 |
| 3.00 | Opening and dismantling of all the wire and accessories from tilted pole and digging the pit for strengthening of existing tilted support of HT/LT line after strengthening of tilted pole fixing of all accessories and re-stringing of old HT/LT line with help of T&P | 50 | Nos. | 3,100 ₹1,55,000 | 3,000 ₹1,50,000 Lowest | 3,120 ₹1,56,000 |
| 4.00 | Dragging of ST/PCC Pole to pit site, diging of pit erection and grouting (As per RESPO Norms) of 11 KV line with fixing of necessary item, such as V-type X-arm, F-bracket, 11 KV Pin insulator, Gaurding angle (1.8 mm 65x65x6) with Nut & bolts its ramming as per RESSPO Specification. Only Pole and insulator will be Provided by the Department. | 50 | Nos. | 3,650 ₹1,82,500 | 3,600 ₹1,80,000 Lowest | 3,660 ₹1,83,000 |
| 5.00 | Dragging of ST/PCC Pole from Dump Store to pit site, diging of pit erection and grouting (As per RESPO Norms) of LT support suitable for laying of ABC Line on 8.5 Mtr Long PCC Pole by providing of necessary eye hook/Lt Shackle insulator with Clamps and its accessories etc. as per RESSPO Specification. Only Pole will be Provided by the Department. | 150 | Nos. | 3,250 ₹4,87,500 | 3,200 ₹4,80,000 Lowest | 3,260 ₹4,89,000 |
| 6.00 | Well type earthing of with 60 Fit Deep boring and providing GI Pipe 1.5" dia ("B" Class) and earthing must be joint by G.I. Strip of 32x5 mm thick long attached with nut & bolts and GI pipe cap. All material and labour shall be supplied the contractor. | 20 | Nos. | 12,000 ₹2,40,000 Lowest | 12,000 ₹2,40,000 Lowest | 12,100 ₹2,42,000 |
| 7.00 | Wire mess fencing of 11/0.4 KV S/S shall be made of rectangular of size as per site requirement not exceeding 3 meter fabrication 45x45x5 mm angel the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of wire mesh. Rectangular welded type wire mess of size 50x25 made of 12 S.W.G. wire mess shall be welded all along the periphery of the frame as well as on horizontal runner to give extra strength of welding to wire mess welded on the frame. Diagonal bracing of all the frame panel will be welded with Ms flat of size 25x3mm to support as per RESPO specification & direction of E/I. | 15 | Nos. | 32,000 ₹4,80,000 | 30,000 ₹4,50,000 Lowest | 32,200 ₹4,83,000 |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
5 Aug 2026, 12:00 pmClosed
SUPERINTENDING ENGINEER, (TECHNICAL), AMAUSI ZONE
SE, Sec-5, D, Vrindavan, Amausi Zone, Lucknow
44/SE(T)AMAUSI ZONE/2026-27
2026_MVVNL_1172144_1
44/SE(T)AMAUSI ZONE/2026-27
Open Tender
Electrical Works
Fixed-rate
365 days
LUCKNOW
As per Tender Document
2 documents required · 2 mandatory
₹3,540
E.E., EDD, CESS-Ist, LESA, Lucknow
₹24,000
11 Aug 2026
24 Jul 2026
5 Aug 2026
24 Jul 2026
5 Aug 2026
24 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Safe Loading, Carriage & unloading of following Materials from Centre Store to Pit Site/J.E. Dump Store. | |||||
| 1.01 | a- Line Material | - | Qtl. | 100 | - |
| 1.02 | b- PCC Pole 8.5/9 Mtr. Long. | - | Nos. | 100 | - |
| 1.03 | c- ST Pole 11/9 Mtr. Long | - | Nos. | 10 | - |
| 2 | Repairing of damage/rusted steel tubular pole by digging of pit up to 2 for proper position, putting 3 Nos angle from of size 35x35x6mm, 3 long properly welding on 3 circle with pole than grouting and plinthing 300 mm above level with cement concrete and sand and bricks ballast. (All material, labour and T&P will be provided by the contractor) | - | Nos. | 10 | - |
| 3 | Opening and dismantling of all the wire and accessories from tilted pole and digging the pit for strengthening of existing tilted support of HT/LT line after strengthening of tilted pole fixing of all accessories and re-stringing of old HT/LT line with help of T&P | - | Nos. | 10 | - |
| 4 | Dragging of ST/PCC Pole to pit site, diging of pit erection and grouting (As per RESPO Norms) of 11 KV line with fixing of necessary item, such as V-type X-arm, F-bracket, 11 KV Pin insulator, Gaurding angle (1.8 mm 65x65x6) with Nut & bolts its ramming as per RESSPO Specification. Only Pole and insulator will be Provided by the Department. | - | Nos. | 10 | - |
| 5 | Dragging of ST/PCC Pole from Dump Store to pit site, diging of pit erection and grouting (As per RESPO Norms) of LT support suitable for laying of ABC Line on 8.5 Mtr Long PCC Pole by providing of necessary eye hook/Lt Shackle insulator with Clamps and its accessories etc. as per RESSPO Specification. Only Pole will be Provided by the Department. | - | Nos. | 10 | - |
| 6 | Well type earthing of with 60 Fit Deep boring and providing GI Pipe 1.5" dia ("B" Class) and earthing must be joint by G.I. Strip of 32x5 mm thick long attached with nut & bolts and GI pipe cap. All material and labour shall be supplied the contractor. | - | Nos. | 10 | - |
| 7 | Wire mess fencing of 11/0.4 KV S/S shall be made of rectangular of size as per site requirement not exceeding 3 meter fabrication 45x45x5 mm angel the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of wire mesh. Rectangular welded type wire mess of size 50x25 made of 12 S.W.G. wire mess shall be welded all along the periphery of the frame as well as on horizontal runner to give extra strength of welding to wire mess welded on the frame. Diagonal bracing of all the frame panel will be welded with Ms flat of size 25x3mm to support as per RESPO specification & direction of E/I. | - | Nos. | 10 | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
TenderDoc.pdf
Tender Documents • 1.52 MB
BOQ_2201204.xls
BOQ • 0.30 MB
DateExt.pdf
PDF • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .