Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.7 LAccepted-AOC | ₹33.7 L Quoted ₹34.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹45.5 L+₹10.6 L (30.5%)Rejected-Finance A 93 SECTOR 36 GREATER NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201308 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201308 | ₹45.5 L+₹10.6 L (30.5%) | L2 | Rejected-Finance Being not lowest tenderer |
| 3 | L3₹47.2 L+₹12.4 L (35.5%)Rejected-Finance | ₹47.2 L+₹12.4 L (35.5%) | L3 | Rejected-Finance Being not lowest tenderer |
| 4 | L4₹47.3 L+₹12.5 L (35.8%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | ₹47.3 L+₹12.5 L (35.8%) | L4 | Rejected-Finance Being not lowest tenderer |
| 5 | L5₹48.7 L+₹13.8 L (39.7%)Rejected-Finance | ₹48.7 L+₹13.8 L (39.7%) | L5 | Rejected-Finance Being not lowest tenderer |
| Sl No | Description | Qty | Unit | akenterprises L1 | Neeraj Enterprises L6 | M/S S.K.Electricals L3 | ANAND ENTERPRISES L4 | M/S Yamin L5 | R N Enterprises L7 | FUTURE ENGINEERING L8 | Deepak Electricals L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting, taking down & removing carefully the ceiling fan, exhaust fans, wall bracket fans, Pedestal Fans and air circulating fans etc, from existing position, from any height, of any description, any sweep and from any position / locations, sealing cable end, for repairs / servicing / overhauling / painting / numbering etc and hanging / fixing the repaired fans in same position or at position as directed by EIC after, dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing, fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, connecting to existing electric sources with using new 1.5 Sqmm 3 core multistrandd PVC insulated copper wire (FRLS) to required length and testing at site to the entire satisfaction of Engineer-in-Charge. Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation of fans to & from workshop if required and approved by the Engineer-in-charge for necessary repairs. (iv) Remetaling of motor shaft, polishing and grinding and making to standard size to matching with GM Bush shall be measured and paid for separately under relevant item of Sch ‘A’ (v) Writing of fan No. and painting of fans shall be measured and paid for separately under relevant item of Sch ‘A’ | 420 | Each | 25 ₹10,500 | 81 ₹34,020 | 40 ₹16,800 | 30 ₹12,600 | 60 ₹25,200 | 15 ₹6,300 Lowest | 50 ₹21,000 | 100 ₹42,000 |
| 2.00Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire(Gauge/weight of copper coils shall be as per existing fans) as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction including painting of fans of any description (ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan) with applying one coat of synthetic enamel paint (White/grey) by spray machine including preparation of existing decorated surfaces of fans including engraving / painting MES No. on fan in capital letters of height not less than 20 mm on fan body complete as directed Engineer-in-charge for the following Fans:- | |||||||||||
| 2.01 | Rewinding of motor of ceiling fans 1200/1400 mm sweep complete all as specified and directed. | 180 | Each | 150 ₹27,000 Lowest | 488 ₹87,840 | 290 ₹52,200 | 280 ₹50,400 | 300 ₹54,000 | 275 ₹49,500 | 300 ₹54,000 | 438 ₹78,840 |
| 2.02 | Ditto but rewinding of motor of exhaust fans of 225 mm sweep complete all as specified and directed. | 60 | Each | 150 ₹9,000 Lowest | 393 ₹23,580 | 290 ₹17,400 | 220 ₹13,200 | 300 ₹18,000 | 275 ₹16,500 | 300 ₹18,000 | 343 ₹20,580 |
| 2.03 | Ditto but rewinding of motor of exhaust fans of 300 mm sweep complete all as specified and directed. | 50 | Each | 150 ₹7,500 Lowest | 420 ₹21,000 | 290 ₹14,500 | 250 ₹12,500 | 300 ₹15,000 | 375 ₹18,750 | 300 ₹15,000 | 370 ₹18,500 |
| 2.04 | Ditto but rewinding of motor of exhaust fans of 350 mm sweep complete all as specified and directed. | 60 | Each | 200 ₹12,000 Lowest | 440 ₹26,400 | 290 ₹17,400 | 300 ₹18,000 | 410 ₹24,600 | 325 ₹19,500 | 350 ₹21,000 | 390 ₹23,400 |
| 2.05 | Ditto but rewinding of motor of exhaust fans of 400 mm sweep complete all as specified and directed. | 40 | Each | 200 ₹8,000 Lowest | 495 ₹19,800 | 390 ₹15,600 | 300 ₹12,000 | 400 ₹16,000 | 350 ₹14,000 | 400 ₹16,000 | 445 ₹17,800 |
| 2.06 | Ditto but rewinding of motor of exhaust fans of 600 mm sweep complete all as specified and directed. | 15 | Each | 400 ₹6,000 Lowest | 522 ₹7,830 | 450 ₹6,750 | 500 ₹7,500 | 600 ₹9,000 | 400 ₹6,000 Lowest | 600 ₹9,000 | 472 ₹7,080 |
| 2.07 | Ditto but rewinding of motor of air circulating fan/wall mounting fans of 400 mm sweep complete all as specified and directed. | 10 | Each | 250 ₹2,500 Lowest | 501 ₹5,010 | 390 ₹3,900 | 300 ₹3,000 | 400 ₹4,000 | 450 ₹4,500 | 400 ₹4,000 | 451 ₹4,510 |
| 2.08 | Ditto but rewinding of motor of air circulating fan of 600 mm sweep complete all as specified and directed. | 5 | Each | 400 ₹2,000 Lowest | 542 ₹2,710 | 550 ₹2,750 | 400 ₹2,000 Lowest | 620 ₹3,100 | 450 ₹2,250 | 600 ₹3,000 | 492 ₹2,460 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
30 Jul 2025, 6:00 pmClosed
GE AF Tughlakabad
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
REPAIR/MAINT OF CEILING/WALL/EXHAUST FAN, GEYSER AND PETTY REPAIR TO ELECTIRC SYSTEM AT VSB AND ATTENDING OF INTERNAL /EXTERNAL ELECTRICITY COMPLAINT IN TECH AREA, VAYUSENABAD, MES COLONY AND VSV UNDER GE (AF) TUGHLAKABAD
2025_MES_714983_1
GE/TKD-49/2025-26
Open Tender
Civil Works - Others
Item Rate
270 days
GE AF Tughlakabad
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹0
₹1 L
Yes
11 Feb 2026
4 Jul 2025
1 Aug 2025
5 Jul 2025
30 Jul 2025
19 Jul 2025
Amount
Disconnecting, taking down & removing carefully the ceiling fan, exhaust fans, wall bracket fans, Pedestal Fans and air circulating fans etc, from existing position, from any height, of any description, any sweep and from any position / locations, sealing cable end, for repairs / servicing / overhauling / painting / numbering etc and hanging / fixing the repaired fans in same position or at position as directed by EIC after, dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing, fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, connecting to existing electric sources with using new 1.5 Sqmm 3 core multistrandd PVC insulated copper wire (FRLS) to required length and testing at site to the entire satisfaction of Engineer-in-Charge. Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation of fans to & from workshop if required and approved by the Engineer-in-charge for necessary repairs. (iv) Remetaling of motor shaft, polishing and grinding and making to standard size to matching with GM Bush shall be measured and paid for separately under relevant item of Sch ‘A’ (v) Writing of fan No. and painting of fans shall be measured and paid for separately under relevant item of Sch ‘A’
Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire(Gauge/weight of copper coils shall be as per existing fans) as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction including painting of fans of any description (ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan) with applying one coat of synthetic enamel paint (White/grey) by spray machine including preparation of existing decorated surfaces of fans including engraving / painting MES No. on fan in capital letters of height not less than 20 mm on fan body complete as directed Engineer-in-charge for the following Fans:-
Rewinding of motor of ceiling fans 1200/1400 mm sweep complete all as specified and directed.
Ditto but rewinding of motor of exhaust fans of 225 mm sweep complete all as specified and directed.
Ditto but rewinding of motor of exhaust fans of 300 mm sweep complete all as specified and directed.
Ditto but rewinding of motor of exhaust fans of 350 mm sweep complete all as specified and directed.
Ditto but rewinding of motor of exhaust fans of 400 mm sweep complete all as specified and directed.
Ditto but rewinding of motor of exhaust fans of 600 mm sweep complete all as specified and directed.
Ditto but rewinding of motor of air circulating fan/wall mounting fans of 400 mm sweep complete all as specified and directed.
Ditto but rewinding of motor of air circulating fan of 600 mm sweep complete all as specified and directed.
Supplying only ball bearing No 6201 complete all as specified and directed.
Supplying only ball bearing No 6202 complete all as specified and directed.
Supply only gun metal bushes of any description and size to suit existing motor shaft including remetaling grinding & polishing of fan motor shaft to required shape/size complete all as specified and directed.
Supplying and fixing in repairs capacitor of capacity 2.5 mfd (PVC body) in fans of any description and in any position complete all as specified and directed.
Supplying and fixing in repair capacitor of capacity 3.15 mfd (PVC body) in fans of any description and in any position complete all as specified and directed.
M&L in replacement of the exhaust fan motor for 225 mm sweep with all accessories and depositing into AGE E/M Store yard at Vayusenabad of old one complete all as specified and directed by Engr-in-Charge.
M&L in replacement of the exhaust fan motor for 300 mm sweep with all accessories and depositing into AGE E/M Store yard at Vayusenabad of old one complete all as specified and directed by Engr-in-Charge.
M&L in replacement of the exhaust fan motor for 350 mm sweep with all accessories and depositing into AGE E/M Store yard at Vayusenabad of old one complete all as specified and directed by Engr-in-Charge.
M&L in replacement of the exhaust fan motor for 400 mm sweep with all accessories and depositing into AGE E/M Store yard at Vayusenabad of old one complete all as specified and directed by Engr-in-Charge.
M&L in replacement of the exhaust fan motor for 600 mm sweep complete with all accessories and depositing into AGE E/M Store yard of old one complete all as specified and directed by Engr-in-Charge.
Taking out the old unserviceable louvers of any type upto G+1 storey and S&F the exhaust fan louvers to suit 300 mm sweep exhaust fan made out of MS sheet heavy duty of 22 gauge as per sample kept at AGE E/M (AF) Tughlakabad duly applying two coats of paint over one coat of red oxide primer with all necessary fixing materials and making good the disturbed surface of wall both inner and outer side and match with the existing surfaces complete all as specified and directed by Engr-in-Charge. NOTE- Contractor will make all arrangements of safety devices and safety of their workmen and govt property while carrying out the work.
ditto- all as per sl item No 13 but to carry out the work at G+2 & G+3 of approximate height upto 10 metres.
ditto- all as per sl item No 13 but for 450 mm sweep exhaust fan.
Taking down the old unserviceable exhaust fan from the existing position and M&L in replacement of exhaust fan of 230/250 mm sweep ventilating fan(Plastic/Steel body) speed 1350 rpm and power 60 watts suitable for 230 volts, 50 Hz and deposit the old fan into AGE E/M store yard at Vayusenabad complete all as specified and directed by Engr-in-Charge.
Taking down the old unserviceable exhaust fan from the existing position and Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers with all connected accessories and depositing old fan at AGE E/M store yard complete all as specified and directed by Engr-in-Charge.
Taking down the old unserviceable exhaust fan from the existing position and Supply and fix exhaust fan, plastic body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers with all connected accessories and depositing old fan at AGE E/M store yard complete all as specified and directed by Engr-in-Charge.
S&F in replacement of new ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep, min air delivery 210 CFM with service value 5.00 BEE and taking down and depositing the old ceiling fan at AGE E/M store yard complete all as specified and directed by Engr-in-Charge.
S&F in replacement of new ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 900mm sweep, min air delivery 210 CFM with service value 5.00 BEE and taking down and depositing the old ceiling fan at AGE E/M store yard complete all as specified and directed by Engr-in-Charge.
M&L in replacement of wall fan of 450 mm sweep, 3 blade type, 1440 rpm, 80 watts with 3 speed rating suitable for AC supply, 230 volts, 50 Hz and deposit the old fan into AGE E/M store yard at Vayusenabad complete all as specified and directed by Engr-in-Charge.
Taking out the old unserviceable geyser from the existing position and S&F installation and testing of new Geyser of 25 litres capacity with copper inner tank, 5 star rating suitable for 230 Volts, AC supply, 50 HZ complete with all standard accessories depositing the old geysers at AGE E/M store yard at Vayusena bad complete all as specified and directed by Engr-in-Charge.
Taking down carefully storage type water heater (Geyser) after disconnecting of electric/water connections, removing all scale & dirt by descaling of depositing inner, outer tank & heating elements by HCL or aquat clear pidilite solution, stoppage of minor leaking by soldering/brazing of inner CU tank & replacement of defective/wornout/unserviceable nuts, washers(New components/parts shall be measured & paid separately as supply only herein after) & refixing geyser in its original location including hoisting connecting to water, electrical connection & testing proper functioning of geyser including earthing to the entire satisfaction of Engr-in-Charge for various makes of geysers of following capacity:- Note: Necessary spare parts like Non return valve, stop valve, bib tap/ PVC connection /Copper connections cable, glass wool, element, thermostat, storage tank, geyser assembly, indicator etc shall be measured and paid separately.
25 litres capacity
35/50 litres capacity
Supply and replace the heating element with ISI marked element of capacity 1.5/2.0 KW, suitable for 230 volts, AC, 50 Hz single phase power supply of storage type water heaters of compatible type duly making all connections by replacing inter connecting copper conductor cables and removal of the old unserviceable element complete all as specified and directed by Engr-in-Charge.
S&F thermostat suitable for 25/35/50 litres capacity storage type water heaters of size 9/11 inch long with temperature range of 0-90 degree centigrade including removal of old unserviceable one complete all as specified and directed by Engr-in-Charge.
S&F check/non return valve gun metal of size 15mm bore with necessary GI fittings required at site including removal of old one complete all as specified and directed by Engr-in-Charge.
S&F in replacement of stainless steel assembly for housing the Heating element, 6/8/9 Holes type for 50/35/25 litres for storage type Geyser complete all as specified and directed by Engr-in-Charge.
S&F in replacement of stainless steel tank for 25 litres storage type Geyser with MS collar with rated pressure not less than 7 kg/Sq cm as per existing pattern complete all as specified and directed by Engr-in-Charge.
S&F in replacement of stainless steel tank for 35/50 litres storage type Geyser with MS collar with rated pressure not less than 7 kg/Sq cm as per existing pattern complete all as specified and directed by Engr-in-Charge.
S&F in replacement of glass wool for 50/35/25 litres storage type Geyser, as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement of safety valve ISI marked suitable for storage type Geyser of capacity 50/35/25 litres, as per sample complete all as specified and directed by Engr-in-Charge.
S&F PVC insulated 3 core copper conductor wire of size 2.5 Sqmm overall PVC sheathed for Geyser connection including taking down old one complete all as specified and directed by Engr-in-Charge.
M&L for PVC insulated 3 core copper conductor wire of size 1.5 Sqmm overall PVC sheathed including taking down old one complete all as specified and directed by Engr-in-Charge.
M&L for indicator lamp suitable for 25/35/50 litres geysers as per the existing sample in green and red colour including taking down old one complete all as specified and as directed by Engr-in-Charge.
M&L for after scrapping, cleaning incl preparation of surface of geyser and painting of Geysers and applying two coats of synthetic enamel paint with machine spray paint including writing the MES number on body of the Geyser duly taking down and refixing the connections, testing and commissioning after painting complete all as specified and as directed by Engr-in-Charge.
S&F of rubber ring gasket made out of superior rubber having holes to suit the hole of bar plate complete all as specified and directed by Engr-in-Charge.
S&F Bib tap of size 15 mm, PVC body with crutch or butterfly handle, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engr-in-charge.
S&F PVC braided connection of size 15 mm dia , 18"/24" length with nuts suitable for Hot & Cold water connections of geysers complete all as specified and directed by Engr-in-charge.
Supply only teflon tape PTFE 12 metres long and 19 mm wide complete all as specified and directed by Engr-in-Charge.
Supply only bituminous self adhesive flashing tape of size 10 cm x 5 cm x 1000 cm long Heavy duty, silver or black in colour as per sample complete all as specified and directed by Engr-in-Charge.
M&L for dash fastener and screws suitable for fixing/hanging electric geysers of capacity upto 50 ltrs fabricated with bronze and having 10 mm bore and 150 mm long with internal nails all as per sample kept at AGE E/M office complete all as specified and directed by Engr-in-Charge.
Taking down carefully copper /Aluminium point wiring any type (light, fan, socket or power) complete, fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately) removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. complete all as specified and directed by Engr-in-Charge.
Taking down old DB's any size from site and making the good to the disturbed surface complete all as specified and directed by Engr-in-Charge.
Taking down old sub main wiring of any type and description including removal of teak wood batten/pipe etc complete all as specified and directed by Engr-in-Charge.
M&L for point wiring complete with 1.5 Sqmm (nominal area) PVC insulated, multi stranded, FRLS copper conductor cable unsheathed in and include PVC conduit with all fittings medium grade ISI Marked and PVC insulated FRLS copper conductor cable of size 1.5 sq mm as earth wire, connected to common earth dolly suitable for mounting modular switches incl modular metal flush boxes and modular face plate all as specified and as directed by Engr-in-charge, (The works includes cutting of chases and making good disturbed surfaces and rate deemed to included in quoted rate complete all as specified and directed by Engr-in-Charge.
One light/fan point controlled by one way switch
One socket point outlet 5/3 pin 5 amps controlled by one switch on the same board.
One socket point outlet 5/3 pin 5 amps controlled by one switch on independent board.
All as per item no 43 above but One 3 pin socket out let 15 Amps on independent board, with cables 2.5.0 Sq mm size and earth wire 1.5.0 sqmm.
M&L in replacement for modular socket outlet 6A, 2/3 pin combined 2 module
M&L in replacement of modular socket outlet 6A/16A, 2/3 pin combined 2 module
M&L in replacement of modular switch 1 way 6 Amps 1 module, suitable for 230 Volts Ac supply.
M&L in replacement of modular switch 1 way 15/16 Amps 1 module, suitable for 230 Volts Ac supply.
M&L in replacement ceiling rose , 3 phase / PVC/ polycarbonate, isolated body.
M&L in replacement of modular white cover plate with frame 1 module.
M&L in replacement of for modular white cover plate with frame 3 module
M&L in replacement of for modular white cover plate with frame 6 module
M&L in replacement of modular white cover plate with frame 8 module.
M&L in replacement of modular metal flush box for 3 module
M&L in replacement of modular metal flush box for 6 module
M&L in replacement of modular metal flush box for 8 module .
M&L in replacement for concealed submain of wiring complete with two run of 4 Sqmm (nominal area) PVC insulated, multi stranded, FRLS copper conductor cable unsheated drawn through and including 20 mm dia PVC conduit with all fitting medium grade ISI marked with PVC insulated FRLS copper conductor cable of size 2.5 Sqmm as earth wire connected to common earth dolly complete all as specified and directed by Engr-in-charge. Note:- (i) The work include cutting of chases and making good the disturbed surfaces and quoted rate deemed to be included the same aspect. (ii) One run of conduit with accessories , three runs of 4 Sqmm copper conductor will be measured as one unit of RM.
Supply and fixing in replacement of LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed mounted type with high efficiency PMMA diffuser( warm white/white as suitable) complete fitting with driver, suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosure for MCB DB double door single pole and neutral 8 way with 200 Amps rated bus bar 240 volts double door type complete all as specified and directed by Engr-in-Charge.
All as per item No 59 above but 4 way DB complete all as specified and directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosure distribution board with hinged cover metal door epoxy powder coated/made of insulating material like, ploystyrene, double door 12 way TPN with suitable rated bus bar for (vertical operation) incorporation of MCCB 4 pole 125 Amps 25 KA complete all as specified and directed by Engr-in-Charge. Note : MCCB's, MCB's, Isolators shall be measured and paid separately.
S&F in replacement of MCB SP 5 to 30 Amps 240 volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB SPN capacity upto 40 amps 240 volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCCB 4 pole, 125 Amps with breaking capacity 16 KA, 415 volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB TPN 4 pole, 100 Amps with breaking capacity 16 KA, 415 volts complete all as specified and directed by Engr-in-Charge.
M&L in replacement for concealed submain of wiring complete with two run of 2.5 Sqmm (nominal area) PVC insulated , multi stranded, FRLS copper conductor cable unsheated drawn through and including 20 mm dia PVC conduit with all fitting medium grade ISI marked with PVC insulated FRLS copper conductor cable of size 1.5 Sqmm as earth wire connected to common earth dolly complete all as specified and directed by Engr-in-charge. Note:- (i) The work include cutting of chases and making good the disturbed surfaces and quoted rate deemed to be included the same aspect. (ii) One run of conduit with accessories , three runs of 2.5 Sqmm copper conductor will be measured as one unit of RM.
M&L in replacement for Earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvanized earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 3 and testing on completion including adequate charcoal dust common salt necessary excavation & earth work PCC (1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC (1:2:4) reinforced with 6 mm dia MS bars with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe connected to earthing list point complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of PVC 20 mm casing N caping of 2 mtrs length.
Supply and Fix in replacement of PVC 20 mm conduit of 3 mtrs length.
Supply and fix in replacement of 5/6 amp 3 pin plug tops complete all as specified and directed.
Supply and fix in replacement of 15/16 amp 3 pin plug tops complete all as specified and directed.
Supply and Fix in replacement of copper conductor multistranded standard FRLS PVC insulated 1.5 Sqmm complete all as specified and directed by Engr-in-charge.
Supply and Fix in replacement of copper conductor multistranded standard FRLS standard FR PVC insulated 2.5 Sqmm complete all as specified and directed by Engr-in-charge.
Supply and Fix in replacement of copper conductor multistranded standard FRLS 3 core PVC insulated 6.00 Sqmm complete all as specified and directed by Engr-in-charge.
S&F in replacement of wall mounted LED tube light 20 watt 6500K, extruded polycarbonate for efficient heat dissipation & integrated electronic driver 230 Volt, AC, single phase, 50 Hz, white/warm white in colour incl all accessories prewired including making necessary electrical connection with 3 core copper coductor and testing complete all as directed by Engr-in-charge.
Supply and fix in replacement of 15 Amp switch socket 2 in 1, 3 pin box type ISI mark
S&F in replacement of canopy for ceiling fan of size 1200/1400mm sweep of any make complete all as specified and directed by Engr-in-Charge.
S&F in replacement of down rod for ceiling fan 1200/1400mm sweep of size 15 mm dia upto 1 .5 mtr long duly painted with approved synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Hanging clamp suitable for the ceiling fan of size 1200/1400mm of any make complete with nuts, bolts, rubber reel and locking pin complete all as specified and directed by Engr-in-Charge.
S&F in replacement of step type electronic fan regulator of the Modular socket type, single phase 220 V complete all as specified and directed by Engr-in-Charge.
S&F in replacement of step type electronic fan regulator of the flush type/ socket type, single phase 220 V complete all as specified and directed by Engr-in-Charge.
M&L in replacement laying , jointing, welding & testing MS pipe (Heavy duty Class 'c') including all fittings as required of following sizes laid in trenches or laying on floor/duct for connecting to various pressure tool/equipment of the following size complete all as specified and directed by Engr-in-Charge. Note:- MS flange and flange joint complete with jointing material shall deemed to be included in the unit rate of this item
80 mm bore
25 mm bore
20 mm bore
Taking out old unsv/rusted MS pipeline from trenches,duct, road etc including necessary unsv fittings and accessories of following size:-
80 mm bore
25 mm bore
20 mm bore
S&F in replacement Ball valve brass 20mm dia with iron handle screwed both ends for iron pipe and fixed including taking down old unsv valve complete all as specified and directed by Engr-in-charge.
S&F in replacement Ball valve brass 25mm dia with iron handle screwed both ends for iron pipe and fixed including taking down old unsv valve complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of sluice valve flanged end drilled type with steel spindle including nuts, bolts and jointing material of class PN-1.6 ISI marked of size 80 mm bore complete all as specified and directed by Engr-in-charge.
Attending complaint and taking down existing ceiling/wall/exhaust fan/ tube light fittings/panel light/switch socket/batten holder carefully (any capacity ,any type) from building carrying out necessary repairing at E/M yard and refixing into the existing location including replacement of unserviceable/ defective spare parts i.e.(tube light fittings/panel light/switch socket/batten holder) and making good disturbed surfaces of walls, floors complete all as specified and directed by Engr-in-Charge. Note: Spare parts shall be Measured separately except minor spare parts such as screw, nuts, bolts, washers etc. shall deemed to be included in unit rate quoted (i) Tools, ladder required to carry out the work shall be provided by the contractor. (ii) Contractor will ensure the safety of the workers employed at his own risk.(iii) Contractor shall provided Skilled ITI Electrician and Produce the Certificate for the commencement of work.
Dismantling and refixing ceiling fan after complete cleaning of dust, applying a coat of painting on ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filler, writing MES Noon ceiling fan and connecting up and including provision of cable from ceiling rose to connector to foundation complete all as specified and directed by Engr-in-Charge.
Dismantling & refixing only exhaust fan after complete cleaning all dust, one coat of painting of exhaust fan complete with synthetic enamel paint by spraying including filling cavities with filler, writing MES No on exhaust fan and connecting up and including provision of cable from ceiling rose to connector to fdn complete all as specified and directed by Engr-in-Charge.
Dismantling & refixing water storage type of 25 Ltrs complete with help of anchor fasteners, nuts, bolts making necessary electrical connections and water connection with new PVC Connection of 15 mm size heavy duty internally steel coated ISI Marked of length 600 mm complete all as specified and directed by Engr-in-Charge.
Dismantling & refixing LED Tube Light any type and size complete with clamp making necessary electrical connections complete all as specified and directed by Engr-in-Charge.
Labour only for attending complaints in tech area of any nature pertaining to internal electrification, ceiling/wall/exhaust fan/air circulator, fault finding, short circuiting, No light of any nature any where reported by users, bldg lights including flood lights/high bay Light fitting of any wattage at height of15 to 18 mtr, LT control panel, main distribution board, sub distribution board and connected wiring/control LT cables of size of any type and any location and locating the fault and rectification of the fault and replacing the burnt out items as per site requirement incl making connection and testing after completion of job complete all as specified and as directed by Engr-In-Charge.
Labour only for attending elect complaints under Vayusenabad of any nature pertaining to internal electrification, ceiling Fan/Geyser /exhaust fan/or, fault finding, short circuiting, No light of any nature any where reported by users, bldg light, main distribution board, and connected wiring/control LT cables of size of any type and any location and locating the fault and rectification of the fault and replacing the burnt out items as per site requirement incl making connection and testing after completion of job complete all as specified and as directed by Engr-In-Charge. Note for item no. 92 & 93 :- (i) The T&P items and testing lamp shall be provided by the Contractor at his own cost. (ii) Any spare required for rectification/replacement will be paid under relevant items. (iii) Work period should be 09 month from date of commencement. (iv) Any spare required for rectification/replacement will be paid under ser no 94 to 142 items. (v) The Contractor or his authorized representative (with mobile phone) shall remain in the complaints cells of GE (AF) TKD located in Tech area & VSB daily for collection of complaint slip from the concerned JE E/M.
(vi) Contractor will supply following well experienced and well conversant team GENERAL NATURE COMPLAINTS at 1000 Hrs to 1800 Hrs & URGENT NATURE COMPLAINTS –24 Hrs at a time for attending elect complaints all working days including Sunday & all Holidays. (vii) The date/time and nature of complaint URGENT or GENERAL shall be indicated on each complaint slip by JE E/M. (viii) Replacement of the items shall be measured and paid separately under serial item no 94 to 142. (ix) All complaint slip shall be returned by the contractor in the complaints cells of GE (AF) TKD daily or same day upto 1700 Hrs to the JE E/M or his representative after necessary repair/ replacement have been carried out and signature of the user on the complaint slip. It is responsibility of the contractor for rectification of complaint to be satisfied by the users. URGENT NATURE OF COMPLAINT: Within 02 Hrs AND GENERAL NATURE COMPLAINTS: Upto 1700Hrs. In Case of failure to rectify the defect in complaints within this time, recovery shall be made from the Contractors @ Rs 500/- per Hrs for Each urgent nature complaint & @ Rs 200/- per day for each general nature complaints. A pucca bound register shall be maintained for this purpose which shall always be kept in custody of JE E/M indicating date. A recovery of missing complaints slip shall be made at rate of @ Rs 10. from the contractor. In case of absent of team Rs. 1000/day per person shall be recovered from contractor's dues.
Supply only modular socket outlet 6A, 2/3 pin combined 2 module
Supply only modular socket outlet 6A/16A, 2/3 pin combined 2 module
Supply only modular switch 1 way 6 Amps 1 module, suitable for 230 Volts Ac supply.
Supply only modular switch 2 way 6 Amps 1 module, suitable for 230 Volts AC supply,
Supply only modular switch 1 way 15/16 Amps 1 module, suitable for 230 Volts Ac supply.
Supply only modular white cover plate with frame 2 module complete all as specified and as directed by EIC.
Supply only modular white cover plate with frame 3 module complete all as specified and as directed by Engr-in-Charge.
Supply only modular white cover plate with frame 6 module complete all as specified and as directed by Engr-in-Charge.
Supply only modular white cover plate with frame 8 module complete all as specified and as directed by Engr-in-Charge.
Supply only modular metal/PVC flush box 2/3 module complete all as specified and as directed by Engr-in-Charge.
Supply only modular metal/PVC flush box 6 module complete all as specified and as directed by Engr-in-Charge.
Supply only modular metal/PVC flush box 8 module complete all as specified and as directed by Engr-in-Charge.
Supply only ceiling rose 3 phase/PVC/ polycarbonate isolated body
Supply only step type electronic fan regulator Modular type, single phase 220 V , 2 module type
Supply only stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc.
Supply only Ding Dong Bell, single phase, 230 volt AC,50 HZ.
M&L in replacement, Batten holder bakelite, AC, 220 Volts,
Supply only Bell push, Modular type, one module suitable for 230 Volts AC supply
Supply only for switch piano flush type single pole one way 5 amps,
Supply only or switch piano flush type single pole one way 15 amps,
Supply only Socket outlet, 3 pin 2 in 1 of 5 amps capacity,
Supply only Socket outlet, 3 pin 2 in 1 of 15 amps capacity,
Supply only Switch socket combination box type 2 in 1 3 pin 5 and 15 amps flush type
Supply only Switch socket combination box type 2 in 1 3 pin 5 amps flush type
Supply only distribution boards in sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps
Supply only distribution boards in sheet metal enclosure for MCB's (D.B) 8 way (SPN) complete
Supply only distribution boards in sheet metal enclosure triple pole and neutral 415 Volts 4 way (TPN) Double door type complete fixed with concealed on walls/on surface and matching with existing surface complete all as specified and as directed by Engr-in-Charge.
Supply only distribution boards in sheet metal enclosure triple pole and neutral vertical Loadline 415 Volts 8 way, IP 43 of metal door type complete with 100 Amps MCCB, (Note- MCCB 100 Amps 4P will be measured in quoted rate by the contractor).
Supply only MCB 240 volts SPN 06- 40 amp 10KA breaking capacity, ISI marked complete all as specified and directed.
Supply only MCB 240 volts SP 6- 32 amp 10KA breaking, capacity, ISI marked, complete all as specified and directed.
Supply only MCB 415 volts TPN 63 amp 10KA breaking, capacity, ISI marked, complete all as specified and directed.
Supply only wall mounted LED batten 20 watt 6500K, extruded polycarbonate for efficient heat dissipation & integrated electronic driver 230 Volt, AC, single phase, 50 Hz, white/warm white in colour incl all accessories prewired including making necessary electrical connection with 3 core copper conductor and testing complete all as directed by Engr-in-charge.
Supply only wall mounted LED batten 10 watt 6500K, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver ,230 Volt, white/warm white in colour incl all accessories prewired including and making necessary electrical connection with 3 core copper conductor and testing complete all as directed by Engr-in-charge.
Supply only 2'x2' size LED panel lighting luminaire glare free illumination suitable for false ceiling (Armstrong/Grid) fitting size 600x600x70 mm (LXWXH) of 42 watts capacity recess mounting with high brightness SMD LEDs incl taking down old UNSV fittings
Supply only 1'x1' size LED panel lighting luminaire glare free illumination suitable for false ceiling (Armstrong/Grid) fitting size 284x284x23 mm (LXWXH) of 12 watts capacity recess mounting with high brightness SMD LEDs incl taking down old UNSV fittings
Supply only LED bulb 9 watt white/warm white in colour and pin/thread type suitable for B22 base complete all as directed by Engr-in-charge .
Supply only LED bulb 12 watt white/warm white in colour and pin/thread type suitable for B22 base complete all as directed by Engr-in-charge .
Supply only copper wire in wiring circuits as per site requirements PVC insulated single core 1.5 Sqmm 1100 volts grade multi stranded conductor complete all as specified and directed by Engr-in-charge.
Supply only copper wire in wiring circuits as per site requirements PVC insulated single core 2.5 Sqmm 1100 volts grade multi stranded conductor complete all as specified and directed by Engr-in-charge.
Supply only copper wire in wiring circuits as per site requirements PVC insulated single core 4 Sqmm 1100 volts grade multi stranded conductor complete all as specified and directed by Engr-in-charge.
Supply only polycarbonate Plug top of 5 Amps, 3 pin 240 Volts complete all as specified and directed by Engr-in-Charge.
Supply only decorative wall light fixture suitable for 15 watt LED lamp B22 base incl taking down old UNSV fittings
Supply only Ultra slim COB Downlighter light of 10 watt in round shape 78 mm dia with durable aluminium housing, reflector for anti-glare and smooth light distribution, controlled beam angle and adjustable focus, energy saving, environmental friendly complete all as specified and directed by the Engr-in-Charge.
Supply only Ultra Slim Downlighter light of 15 watt in round shape 185 mm dia with durable thermally conductive plastic housing & in-built driver, eye protection provided by acrylic diffuser , energy saving, environmental friendly complete all as specified and directed by the Engr-in-Charge.
Supply only polycarbonate Plug top of 15 Amps, 3 pin 240 Volts complete all as specified and directed by Engr-in-Charge.
Supply and replace the heating element with ISI marked element of capacity 1.5/2.0 KW, suitable for 230 volts, AC, 50 Hz single phase power supply of storage type water heaters of compatible type duly making all connections by replacing inter connecting copper conductor cables and removal of the old unserviceable element complete all as specified and directed by Engr-in-Charge.
Supply only PVC braided connection of size 15 mm dia , 18"/24" length with nuts suitable for Hot & Cold water connections of geysers complete all as specified and directed by Engr-in-charge.
Supply only LED bay lights high efficiency downlighter light of 150 watt in round shape 185 mm dia with durable aluminium housing, reflector for anti-glare and high lumen efficiency of >130lm/w, energy saving, environmental friendly complete all as specified and directed by the Engr-in-Charge.
Supply only Ultra Slim surface mounting round LED of 6 watt downlighter designed with excellent thermally managed aluminium pressure round shape 185 mm dia with durable thermally conductive plastic housing & in-built driver, eye protection provided by acrylic diffuser , energy saving, environmental friendly complete all as specified and directed by the Engr-in-Charge.
Deepak Electricals (BID ID -3372626)
M/S S.K.Electricals (BID ID -3368792)
ANAND ENTERPRISES (BID ID -3372349)
M/S Yamin (BID ID -3372579)
Neeraj Enterprises (BID ID -3367193)
R N Enterprises (BID ID -3377477)
FUTURE ENGINEERING (BID ID -3372505)
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .