Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.5 L+₹11,510 (0.39%)Rejected-Finance | L2 | Rejected-Finance Not Reasonable | |
| 3 | L3₹32.1 L+₹2.7 L (9.27%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L3 | Rejected-Finance Not Reasonable | |
| 4 | L4₹34.5 L+₹5.1 L (17.4%)Rejected-Finance 46 HUSENI LAKDA BAZAAR 242 BELLASIS ROAD MUMBAI 400008 | MUMBAI | MAHARASHTRA | 400008 | L4 | Rejected-Finance Not Reasonable | |
| 5 | L5₹35.4 L+₹6.0 L (20.5%)Rejected-Finance | L5 | Rejected-Finance Not Reasonable |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
20 Dec 2023, 6:00 pmClosed
Sh Saurabh Gupta, EE
GE(W) Colaba, Mumbai
REPAIRS TO SUNKEN PORTION, LEAKAGE AND SEEPAGE AND SANITARY FITTINGS OF OTM AND MD ACCN IN AREA IV AND REPAIR/REPLACEMENT/CLEANING OF SEWAGE LINE, MANHOLES, WC PAN, GULLY TRAP ETC IN AREA IV OF AGE B/R WEST AREA UNDER GE (W) COLABA, MUMBAI
2023_MES_629527_1
8804/E8
Open Tender
Civil Works
Item Rate
180 days
GE(W) Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE(W) Colaba, Mumbai
₹1 L
Yes
20 Feb 2024
23 Nov 2023
22 Dec 2023
23 Nov 2023
20 Dec 2023
6 Dec 2023
Amount
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the primises out side MD land all as specified and directed.
M&L Non Skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.06 sqm but not exc 0.11sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of the tiles all as specified and directed. Make: Johnson / Kajaria.
M&L Non Skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.18 sqm but not exc 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of the tiles all as specified and directed. Make: Johnson / Kajaria.
M&L vitrified tiles light/dark shade 10 mm thick (Square/rectangular) area of each tile exc 0.18 sqm but not exc 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles all as specified and directed. Make: Johnson / Kajaria.
M&L Screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes like tiles all as specified and directed.
M&L rendering 10 mm thick on fair faces of brick work in CM (1:4) all as specified and directed.
M&L glazed tiles digital coloured ceramic tiles 300x450x7mm/300x600x7mm thick in vertical surfaces such as skirting and dados set and jointed in neat cement slurry pointed in coloured cement to match the shades of the tiles all as specified and directed. Make : Orient bell / Kajaria. Note:- Rate of designer border (Highlighter) tiles are included in this item.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons, dados etc laid, bedded and pointed in any mortar and removal of rubbish off the site all as specified & directed.
M&L machine cut, polished cudappah stone work 20 to 25 mm thick (table rubbed and polished) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing as in kitchen platform, flooring and all other similar works, including laid over 15mm thick cement mortar (1:4) all as specified and directed.
M&L for granite (of any approved colour) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including grinding and polishing as in kitchen platform, counter for WHB, flooring and all other similar works all as specified and directed.
Taking up or down steel tubing and connection including cleaning for refixing or removal to store, 15 mm dia bore all as specified and directed
Taking up or down steel tubing and connection including cleaning for refixing or removal to store, 20 mm dia bore all as specified and directed
Taking up or down steel tubing and connection including cleaning for refixing or removal to store, 40 mm dia bore all as specified and directed
Fixing only old 15 mm steel tubing and including cleaning in positon walls, ceiling and floor all as specified and directed
Fixing only old 20 mm steel tubing and including cleaning in positon walls, ceiling and floor all as specified and directed
S&F GI tubing 15mm bore medium grade with all fittings and fixed complete to wall and ceiling or laid in floors all as specified and directed. Make: Jindal / Tata / Swastik
S&F GI tubing 20 mm bore medium grade with all fittings and fixed complete to wall and ceiling or laid in floors all as specified and directed. Make: Jindal / Tata / Swastik
Supplying and laying of UPVC pipes 15mm SDR 11 & Plain CPVC SDR 11 fittings in trenches all as specified and directed.
Supplying and laying of UPVC pipes 20mm SDR 11 & Plain CPVC SDR 11 fittings in trenches all as specified and directed.
S&F GI tubing 40mm bore medium grade with all fittings and fixed complete to wall and ceiling or laid in floors all as specified and directed. Make: Jindal / Tata / Swastik
Cutting chases, pinning in making good to facing on brick walls where required and pointing in cement mortar (1:3) to ends for concealed water tubing and making good, cutting n, exc. 10cm girth all as specified and directed.
Demolition and breaking up drain pipes of dia 100 mm (Salt glazed stone ware, AC or Reinforced concrete) set in cement mortar all as specified and directed.
Demolition and breaking up drain pipes of dia 75 mm (Salt glazed stone ware, AC or Reinforced concrete) set in cement mortar all as specified and directed.
S&F PVC(SWR) pipes, 110 mm external dia double socketed in any length with rubber joints, fixed to walls with PVC brackets/clips all as specified and directed.
S&F PVC(SWR) pipes, 75 mm external dia double socketed in any length with rubber joints, fixed to walls with PVC brackets/clips all as specified and directed.
S&F in repairs 75mm dia PVC (SWR) bends all as specified and directed.
S&F in repairs 75mm dia PVC (SWR) bends but with access door all as specified and directed.
S&F in repairs 110 mm dia PVC (SWR) bends all as specified and directed.
S&F in repairs 110 mm dia PVC (SWR) bends but with access door all as specified and directed.
S&F in repairs 75mm PVC (SWR) branch piece, single (single Y) equal or unequal all as specified and directed.
S&F in repairs 110 mm PVC (SWR) branch piece, single (single Y) equal or unequal all as specified and directed.
S&F in repairs 110mm dia PVC (SWR) vent cowl all as specified and directed.
S&F in repair vitreous China wash down water closet pan (pedestal pattern) white, incl. trap, connection to drain and flushing pipe (excluding flushing cistern) including seat cover for pedstal pan all as specified and directed. Make : Cat Part No S1050102 of Cera or Equivalent in Hindware / Parryware.
S&F in repairs two peice vitreous China wash down water closet pan (pedestal pattern) white, incl. trap, connection to drain and flushing pipe, including flushing cistern, including soft close seat cover for pedstal pan all as specified and directed. Make : Cat Part No S1021105 of Cera or Equivalent in Hindware / Parryware.
S&F in repairs vitreous China wash basin white, flat back, size 580X450 mm including cutting for pinning in ends of bracketsall as specified and directed. Make : Cat Part No S2040139 of Cera or Equivalent in Hindware / Parryware.
S&F in repairs 10 litre capacity PVC low level flushing cistern with all accessories fixed with WC including syphone pipe, PVC flushing pipe of any size all as specified and directed. Make : Cat Part No B1010106 of Cera or Equivalent in Hindware / Parryware.
S&F in repairs counter sunk wash basin oval shape 550x460mm fixed with waste coupling & waste pipe & accessories of any size all as specified and directed. Make : Cat Part No 10095 of Hindware or equivalent in Cera / Parryware.
S&F in repairs wall mounted water closet pan of size 510x360x360mm fixed with anchour fastener, outlet pipe & accessories of any size all as specified and directed. Make : Cera Cat Part No S1043170 of Hindware or equivalent in Cera / Parryware.
S&F Grab Bar (Stainless Steel) 600mm Long fixed to the wall all as specified & directed.
S&F Handrail (Stainless Steel) of suitable size all as specified & directed.
S&F as in repairs 15 mm bore fancy type angular valve cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions all as specified and directed.. Make:- ESS ESS CROMA Cat Part No C 204 or Equivalent of Jaquar/Prayag
S&F as in repairs 15 mm bore fancy type concealed stop cock (regular body) cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions all as specified and directed. Make:- ESS ESS CROMA Cat Part No C 332 or Equivalent of Jaquar
S&F as in repairs 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed screwed both ends for iron pipe or for unions all as specified and directed.
S&F in repairs 40 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed screwed both ends for iron pipe or for unions all as specified and directed.
S&F PVC connection 15mm size PTMT nuts of length 450 mm all as specified and directed.
S&F in repairs 15 mm bore fancy type bib taps long body cast copper alloy 15mm bore with fancy chromium plated screwed down, screwed for iron pipe or for brass ferrule all as specified and directed. Make:- ESS ESS CROMA Cat Part No C 202 or Equivalent of Jaquar
S&F in repairs 15 mm bore fancy type 2-in-1 bib taps long body cast copper alloy 15mm bore with fancy chromium plated screwed down, screwed for iron pipe or for brass ferrule. with wall flange all as specified and directed. Make:- ESS ESS CROMA Cat Part No C 203 or Equivalent of Jaquar
M&L in repairs for 15 mm bore fancy type wall mixer with 115 mm long bend pipe for connection to overhead shower (with bush and piston Divertor fittings) with aerator all as specified and directed. Make:- ESS ESS CROMA Cat Part No C 216 or Equivalent of Jaquar .
M&L in repairs fancy type 15 mm bore central hole basin mixture with 'U' shaped round casted spout with 3" long pipe connection with aerator all as specified and directed. Make : Jaquar Cat Part No CON-169KNB or Equivalent of Prayag
S&F in repairs 15 mm bore, brass chromium plated, fancy type health faucet with SS connection pipe 1 mtr long all as specified and directed. Make:- ESS ESS CROMA Cat Part No C 232D or Equivalent of Jaquar/ Parko.
S&F in repairs fancy type CP Towel Rail 61 cm long all as specified and directed. Make : ESS ESS CROMA Cat Part No C 412 or equivalent of Jaquar/ Parko.
S&F in repairs CP Towel Ring all as specified and directed. Make:- ESS ESS CROMA Cat Part No AC 502 or Equivalent of Jaquar/ Parko
S&F in repairs CP soap dish all as specified and directed. Make:- ESS ESS CROMA Cat Part No C 414 or Equivalent ofJaquar/ Parko.
S&F in repairs CP toilet paper holder all as specified and directed. Make:- ESS ESS CROMA Cat Part No AC 206 or Equivalent of Jaquar/ Parko.
S&F in repairs CP Towel Bracket (61 CM) long all as specified and directed. Make:- ESS ESS CROMA Cat Part No C 423 or Equivalent of Jaquar/ Parko
S&F sheet glass corner shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long all as specified and directed.
S&F 15 mm bore overhead shower of size 150x150mm single flow (ABS body chrome plated with grey face plate) with rubit cleaning system including shower arm 200 mm long (stainless steel) square shape with wall flange all as specified & directed. Make:- Cera Cat Part Not F7010506AB or Equivalent of Jaquar / Parko.
S&F in repairs stainless steel grating round 125mm size of anti cockroach, anti clog, anti faul all as specified and directed.
S&F in repairs 15 mm bore piller taps cast copper alloy, with capstan heads, chromium plated, screwed down, fancy type high pressure, with or without lettred 'HOT or COLD' with long screwed sunk and fly nuts all as specified & directed. Make:- ESS ESS CROMA Cat Part No C 201 or Equivalent of Jaquar / Parko.
S&F mirror cabinet PTMT of 400mm x 500 mm with megnetic looking arrangements fixed with and inclduling chromium plated brass screws and PVC rawl plugs all as specified and directed. Make : Prayag. Cat Part No 554 or equalent make.
S& F in repairs water closet seat cover any coloured pattern with flat bottom and mild steel chromium plated or aluminium hinging devices all as specified and directed. Make : Cat Part No S1020101 of Cera or Equivalent in Hindware / Parryware.
S&F in repairs urinals flat back with integrated EFS of size 355x340x535mm in snow white including each and all acessories all as specified and directed. Make: Jaguar(Item code-URS-WHT-13261. HSN code-69109000) / Kerovit / Parko
S&F in repairs auto closing flushing valve for flat back urinals all as specified and directed. Make: Jaguar. (Item code-PRS-CHR-077. HSN code-84818020) / Kerovit / Parko
S&F in repairs sink with draining board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement morter to dwarft wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410 mm x 330mm x 160mm all as specified and directed. Make : Blue Star Model No SBSD-127 or equivelant of Nirali / Prayag
S&F in repairs Kitchen sink without drainage board made of stainless steel 1 mm thick, with plugs, washers and waste pipe & coupling including bedding in cement morter to dwarft wall or including fixing GI cantilever brackets as per site requirement and connecting with suitable size of pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 178mm (or nearest size as per Cat Part specified) all as specified & directed. Make : Blue Star Model No SSSB-06A or equivalent of Nirali / Prayag.
M&L in repairs 75 mm dia PVC(SWR) multi floor trap with grating including jointing with solvent cement all as specified and directed.
Demolition of cement concrete in ground floor & paving n. exc 15 cm thick (below or above GL) unreinforced all as specified and directed.
M&L PCC 1:4:8, type D2 (using 40 mm graded crushed stone aggregate) as in foundation filling, mass and concrete and sunken floor treatments all as specified and directed.
M&L for repairs to sunken portion of slab.Treatment of sunken floor slab compraises of the following specifications and all as specified :- (i) M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick avg PCC 1:2:4 type B-0 (using 12.5mm graded crushed aggregate) as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for spout. (ii) Rendering of uneven surfaces with 6mm thick in CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting carried out. (WPC shall be measured & paid separately) (iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy puty . (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) M&L for applying two coats of polymer modified cementious water proof coating with DR. Fixit Pidicrete URP with cement Ratio 1:1.5 as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. (vi) Plaster the bottom and sides up to full height of sunken with minimum 20mm thick CM 1:4 mixed with integral water proofing compound ( DR.Fixit Pidifin 2K) 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout. ( WPC shall be measured & paid separately) (vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:2:4 all round after painting with anticorrosive paint Note 1 :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test shall be done in presence of reps of MES and record for each sunken slab shall be maintained. Cost of testing is inclued in the rates quoted above. For the purpose of payment area of bottom and sides of sunken shall be measured in sqm
Supply only liquid water proofing compound all as specified and as directed. Make : Pidilite / Sika / Fosroc.
S&F in repair vitreous China squatting pan, ' Orissa patteren, size 580 x 440 mm white, with integral foot rests (excluding flushing cisteren and flush pipe) including taking down existing squating pan all as specified and directed. Make : Cat Part No S3010104 of Cera or Equivalent in Hindware / Parryware.
M&L for complete removal of existing treatment and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 1mm thick (average) Birla wall putty all as specified & directed. Make : Asian Paints / Berger Paints.
Dismantling Asbestos sheeting, any gauge, thickness, roof coverings including scafoldings of any hieght all as specified and directed.
Dismantling of framed work of timber in scantlings 40 sqcm and over in section, in any position all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based trapezoidal/mangalore tile profile roofing sheets, chajjas, 0.50 mm thick of any colour/length having tensile strength of 550 MPA as in roof coverings having effective & overall width 1015 mm &1072 mm respectively, profile hieght 28.5 mm and centre to centre distance between ribs 203 mm fixed with self tapping screws as directed by manufacturer on wooden/steel members including scafoldings of any height of the bldg all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPA as in roof coverings /claddings to wall, fixed with self tapping screws including scafoldings of any hieght all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
S&F joist, channel, angle,or tee sections, or MS Flats fixed independantly without connecting plates, etc. Fe 410-W (Gde-E- 250) quality- A (cut to ordinary lengths i.e within 20mm of length indicated) as in frame work for Galvalume / CGI chajjas all as specified and directed.
S&F structural steel work in tubular/square tube trusses including special shaped washer, gusset/bearing plate etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 all as specified and directed. Note : the above item includes and bending of tubes or all type of any desing required on site for fiixing of tubes No extra pament will be paid to the contractor.
S&F in repairs to replace old or decayed boarding in patches including cutting out old, piecing, heading joints etc 20 mm thick second class hardwood clean sawn boarding fixed with nails with butt joints in any situation including scafoldings of any hieght all as specified and directed.
Fixing only in repairs in patches including cutting out old, piecing, heading joints etc 20 mm thick second class hardwood clean sawn boarding fixed with nails with butt joints in any situation including scafoldings of any hieght all as specified and directed.
M&L in repairs to replace old or decayed boarding in patches including cutting out old, piecing, heading joints etc second class hardwood wheather boarding, clean sawn, plain, 20 mm thick or feather edged 15 mm to 20 mm thick and fixed with 30 mm laps and removing dismantled boarding in any situation including scafoldings of any hieght all as specified and directed.
Dismantling Mangalore pattern or similar tiles in roofing including portions bedded in cement mortar of any hieght including scafolding all as specified and directed.
M&L for roof tiles, Mangalore Pattern, interlocking at side joints, laid dry including scafoldings of any hieght all as specified and directed.
Fixing only roof tiles, Mangalore Pattern, interlocking at side joints, laid dry including scafoldings of any hieght all as specified and directed.
M&L for ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 all as specified and directed.
Fixing only ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 including scafoldings of any hieght all as specified and directed.
Dismantling of roof battens for tiles, shingles of any size including tilting fillets spaced n exc 15 cm of any description in any position all as specified and directed.
M&L second class hardwood clean sawn battens at 30cm centres sectional area exc 15 & n exc 25 Sqcm including scafoldings of any hieght all as specified and directed.
Fixing only second class hardwood clean sawn battens at 30cm centres sectional area exc 15 & n exc 25 Sqcm including scafoldings of any hieght all as specified and directed.
M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (ordinary paint tint) (each coat) over a coat of pink primer including scafoldings of any hieght all as specified and directed.
M&L for preparation of old decorated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (ordinary paint tint) (each coat) over a coat of pink primer including scafoldings of any hieght all as specified and directed.
M&L in repairs to replace old decayed timber (including piecing, scarifying, etc of old and mew timber if required) second class hard wood clean sawn in scantlings timber framed and fixed in any position and description including scafoldings of any hieght all as specified and directed.
M&L for preparing surfaces of battens, any size and spacing, and treated all over with creosote (measured overall on one side only, spaces not deducted) including scafoldings of any hieght all as specified and directed.
Demolition of ceiling boards of any description, and any thickness including cover fillets and frame work all as specified and directed.
M&L for powder coated aluminium snap grid of size of 605mm x 605mm and sections incorporated in frame work shall conform to IS 733, IS 737 and IS 1285 and snap grid frame work shall be fixed to ceiling with supporting hanger 6mm dia mild steel rod, J bolts with necessary bolts, nuts and washers all as per manufacturer's instruction. The main & cross tees shall be jointed at junction/crossings with anodized aluminum angle bracket of size 19.05mm x 19.05mm x 1.45mm, weighing 0.14 Kg per RM, fixed with suitable mild steel, bolts nuts and washer all as per manufacturer's instruction, the snap grid shall be supported at ends all along the wall with anodized aluminum angle of size 38mm x 25mm x 2.18mm, weighing 0.358 Kg per running meter all as specified and directed.
S&F 9mm thick PVC laminated gypsum ceiling tiles size of 600mm x 600mm, square edge, front side laminated PVC and back side aluminium foil all as specified and directed.
Demolition of brick work or stone /boulder masonry built in cement mortar, including all quoins, arches, pillars all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius and built in CM (1:6) all as specified and directed.
Taking down cement plaster of any description from brick wall surfaces etc including racking out joints and hacking for key, scrubbing down with water including all necessary scaffolding arrangments of any height all as specified and directed.
M&L for cement mortar (general purpose, factory made, for outdoor use having bulk density (of dry mix) 1600 kg per cubic metre, wet density (after mixing) 1800 kg percubic metre, dry density after setting 1800 kg per cubic metre, pot life 60 minutes, compressive strength 1.5 Mpa to 5 Mpa, made using well graded manufatured sand filler, portland cement & polymer binder, and chemical additives) for external rendering 12mm thick on brick wall or concrete surfaces including making groove of appropriate size and finishing sand faced finished using sponge including all necessary scaffolding arrangments of any height all as specified and as directed.
M & L for cement mortar (general purpose, factory made, for Indoor use having bulk density (of dry mix) 1600 kg per cubic metre, wet density (after mixing) 1800 kg percubic metre, dry density after setting 1800 kg per cubic metre,pot life 60 minutes, compressive strength 1.5 Mpa to 5 Mpa, made using well graded manufatured sand filler, portland cement & polymer binder, and chemical additives) for internal rendering 10mm thick on brick wall or concrete surfaces including making groove of appropriate size and finishing sand faced finished using sponge including all necessary scaffolding arrangments of any height complete all as specified and directed.
Supply only liquid water proofing compound LW+ of Dr. fixit or equivalent all as specified and directed.
M&L for preparation of surfaces cracks of plaster internal/external of walls, ceilings/Chajjas upto 5 mm wide, remove the loose plaster/concrete by suitable tools, filling cracks with crack paste compound and apply the second coat after 10-12 hrs of application of first coat including necessary scafolding of any hieght all as specifed and directed. Make :- Use of Dr Fixit 'X' paste compound/ Build Core Compound / Fosroc Compound, as approved by GE through their authorised applicator only.
M&L for preparation of surfaces by cutting 'V' groove cracks of plaster internal/external of walls, ceilings/Chajjas all along the crack 5 mm to 10 mm and remove the loose plaster/concrete by suitable tools, filling cracks with crack paste compound and apply the second coat after 10-12 hrs of application of first coat and for external application must be coated with paint including necessary scafolding of any hieght all as specifed and directed. Make : Use of Dr Fixit 'X' paste compound/ Build Core Compound / Fosroc Compound, as approved by GE through their authorised applicator only.
M&L for repairs to damaged surface of RCC elements like beams, columns, wall by removing all loose cement plaster/concrete, providing and laying of micro-concrete more than 20mm thickness (Avg) by using the recommended water powder ratio mix the micro-concrete with pan mixer as per manufacturer's instruction including watertight shuttering necessary curing for 7 days all as specified and directed by Engineer - in - Charge. Note : Micro concrete will be measured and paid separately. through authorised applicator of Dr Fixit/Build core/Fosroc/Peditilite as approved by GE.
Supply only micro-concrete for repair or build core all as specified and directed. Make : Dr Fixit/Build core/Fosroc/Peditilite
M&L for preparation of surface of reinforced bar by applying rust remover and then applying a coat epoxy zinc primer on exposed reinforced surface all as specified and directed. Make : Use of Dr Fixit 'X' paste compound/ Build Core Compound / Fosroc Compound, as approved by GE through their authorised applicator only. Note : Surface area for concrete shall be measured for payment purpose.
M&L for preparing New surfaces of walls/ceilings and applying two coats of weather proof acrylic exterior paint (100% Acrylic) of Apex Ultima, over a coat of primer and scaffolding where required at any hieght for external painting all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 1mm thick (average) wall putty all as specified and directed.
M&L for 5 mm thick plaster in CM (1:3) on ceiling surfaces and finish the surface even and smooth without using extra cement all as specified and directed.
M&L for preparation of new or previously untreated surfaces and applying two coats of synthetic enamel paint over a coat of primer red oxide, zinc chrome all as specified and directed.
M&L for prepartion of newly plastered surfaces of ceiling and applying three coat of white wash all as specified and directed.
Demolition of RCC in any postion including cutting of reinforcement as required and removing of debries outside of MOD land all as specified and as directed.
M&L for filling cracks by cutting 'V' groove cracks of internal or external plaster of walls, ceilings/Chajjas all along the crack upto 10 mm and remove the loose plaster/concrete by suitable tools, filling cracks with crack paste compound and apply the second coat after 10-12 hrs of application of first coat and for external application must be coated with paint including necessary scafolding of any hieght all as specifed and direcetd. Make : Use of Dr Fixit Crack 'X' shrinkfree paste compound/ Smartcare Texture Crack Filler / Build Core Compound / Fosroc Compound, as approved by GE
M&L for cleaning all loose laitance on the wall and concrete substrate and applying one coat of epoxy bonding agent of SBR latex on exposed concrete surface to ensure bond between old concrete & new concrete by brush application including scafolding at any height of bldg as specified and directed. Make: Dr. Fixit epoxy bonding agent or Shalicrete URP of STP Ltd or Nerolac perma SBR latex
M&L for plastering 20 mm thick average Polymer modified mortar (ready mix pack) in two coat 15 mm base coat and 5 mm finishing coat with and including curing as per manufacturer's instruction all as specified and as directed. Make : Dr. Fixit Repair Pro Polymer Mortar, Fosroc RENDEROC S2 structural grade polymer mortar, ShaliFix FRM Polymer Modified Fiber Reinforced Mortar of STP or equivalent as approved by GE
M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in flooring/plinth protection and all other similar works all as specified and directed.
M&L for 50 mm thick PCC 1:2:4 type B1 (using 12.5 mm graded crushed stone aggregates) as in floor, finished cement concrete surfaces even and smooth using extra cement all as specified and directed.
M&L in repairs 6mm thick ply wood, grade BWR, type BB fixed with screws to timber frame work for cupboards all as specified & directed.
S&F in repairs coloured glass mosaic tiles of size 25mm x 25 mm having thickness 6-8 mm for swimming Pool or any other places following SOP for Walls and Floor jointed & pointed with epoxy tile grout with the colour of tiles using water proofing tile in vertical & horizontal surfaces with tile adhesive mixed with latex admixture (MYK LATICRETE or equivalent) and 3mm wide joints pointed in matching colour of epoxy grout (MYK LATICRETE SP 100) or other equal & approved all to manufacturer’s printed instruction and laid to approved pattern on backing cement-sand render & screed (measured separately) all as specified and directed. Note : (a) Tile should be applied by experienced applicator who has completed swimming pool work at other places. Applicator must show its completed projects application to Engineer-in-charge before going ahead with works (b) Tile design sample has to be produced by the contractor and passed by GE before application.
S&F in repairs PVC tensile fabric structure with PVDF (polyvinyl-idene-fluoride) coating with all necessary fixtures, of any size and shape for making canopies, shed fixed with mild steel structural frame work, weight of the fabric is considered, with fabrics ranging from 900 gsm to 1200 gsm all as specified and directed. Note : (a) The shape/ design of the sheds will be as approved by GE. (b) Cost of structural steel used will be measured and paid separetly under relevant items in this schdule. Make: Mehler/ Sieon/ Haytes/ Ferrari or equivalent as approved by GE.
Cleaning of RCC water tanks 5000 to 10000 litres of various capacity in existing position by mechanised pressure cleaned by Mechanical high pressure spray and steel wire brush to remove algae/dirt/foregin completely and soaking out water/dirt with a high pressure wet vaccume pump and removing spoils outside of MD land and providing sticker showing the date of cleaning all as specified and directed.
Cleaning of PVC water tanks of capacity exceeding 250 litres but not exceeding 500 litres including chemical treatment with Anti-bacterial agent consisting of following process: - Dewatering the tank with submersible pump, de-silting and removing of left over dirty water up to 100 to 150 mm in the bottom of the tank and sludge with special sludge pump, cleaning of walls and ceiling with special mechanized high pressure jet machines by rotary jet system at 100-120 Bar pressure (120 Kg /sq cm) which dislodges the layer of dirt, algae, fungus stuck on its surface usage of scrubbing machines for old stains and cleaning chemicals if required of make Eureka Forbes Ltd, floor of the dirty tank should be thoroughly cleaned up by fry jet cleaner to accumulate all dirt, the remaining sludge should than be removed by sludge pumps, the dirt silt and other foreign material should further be removed by Industrial Vacuum Cleaners to make the floor totally dirt free, application/spraying of Anti-Bacterial chemicals to ensure total sterilization of tank from the inside, inside of the tank should be treated with specially developed 4 ft long ultraviolet Radiator to kill further floating bacteria/virus in order to make the tank totally clean, bacteria free and safe for storage of drinking water. All the above operations should be executed by trained workers and technicians, properly dressed along with gum boots, to work as per the direction of Engineer in charge. Note : Date of cleaning will be imposed on water tank.
Cleaning of PVC water tanks of capacity exceeding 501 litres but not exceeding 1000 litres including chemical treatment with Anti-bacterial agent consisting of following process: - Dewatering the tank with submersible pump, de-silting and removing of left over dirty water up to 100 to 150 mm in the bottom of the tank and sludge with special sludge pump, cleaning of walls and ceiling with special mechanized high pressure jet machines by rotary jet system at 100-120 Bar pressure (120 Kg /sq cm) which dislodges the layer of dirt, algae, fungus stuck on its surface usage of scrubbing machines for old stains and cleaning chemicals if required of make Eureka Forbes Ltd, floor of the dirty tank should be thoroughly cleaned up by fry jet cleaner to accumulate all dirt ,the remaining sludge should than be removed by sludge pumps, the dirt silt and other foreign material should further be removed by Industrial Vacuum Cleaners to make the floor totally dirt free, application/spraying of Anti-Bacterial chemicals to ensure total sterilization of tank from the inside, inside of the tank should be treated with specially developed 4 ft long ultraviolet Radiator to kill further floating bacteria/virus in order to make the tank totally clean, bacteria free and safe for storage of drinking water. All the above operations should be executed by trained workers and technicians, properly dressed along with gum boots, to work as per the direction of Engineer in charge. Note : Date of cleaning will be imposed on water tank.
Cleaning of PVC water tanks of capacity exceeding 1001 litres but not exceeding 3000 litres including chemical treatment with Anti-bacterial agent consisting of following process: - Dewatering the tank with submersible pump, de-silting and removing of left over dirty water up to 100 to 150 mm in the bottom of the tank and sludge with special sludge pump, cleaning of walls and ceiling with special mechanized high pressure jet machines by rotary jet system at 100-120 Bar pressure (120 Kg /sq cm) which dislodges the layer of dirt, algae, fungus stuck on its surface usage of scrubbing machines for old stains and cleaning chemicals if required of make Eureka Forbes Ltd, floor of the dirty tank should be thoroughly cleaned up by fry jet cleaner to accumulate all dirt, the remaining sludge should then be removed by sludge pumps, the dirt silt and other foreign material should further be removed by Industrial Vacuum Cleaners to make the floor totally dirt free, application/spraying of Anti-Bacterial chemicals to ensure total sterilization of tank from the inside, inside of the tank should be treated with specially developed 4 ft long ultraviolet Radiator to kill further floating bacteria/virus in order to make the tank totally clean, bacteria free and safe for storage of drinking water. All the above operations should be executed by trained workers and technicians, properly dressed along with gum boots, to work as per the direction of Engineer in charge. Note : Date of cleaning will be imposed on water tank.
Cleaning of PVC water tanks of capacity exceeding 3001 litres but not exceeding 5000 litres including chemical treatment with Anti-bacterial agent consisting of following process: - Dewatering the tank with submersible pump, de-silting and removing of left over dirty water up to 100 to 150 mm in the bottom of the tank and sludge with special sludge pump, cleaning of walls and ceiling with special mechanized high pressure jet machines by rotary jet system at 100-120 Bar pressure (120 Kg /sq cm) which dislodges the layer of dirt, algae, fungus stuck on its surface usage of scrubbing machines for old stains and cleaning chemicals if required of make Eureka Forbes Ltd, floor of the dirty tank should be thoroughly cleaned up by fry jet cleaner to accumulate all dirt ,the remaining sludge should than be removed by sludge pumps, the dirt silt and other foreign material should further be removed by Industrial Vacuum Cleaners to make the floor totally dirt free, application/spraying of Anti-Bacterial chemicals to ensure total sterilization of tank from the inside, inside of the tank should be treated with specially developed 4 ft long ultraviolet Radiator to kill further floating bacteria/virus in order to make the tank totally clean, bacteria free and safe for storage of drinking water. All the above operations should be executed by trained workers and technicians, properly dressed along with gum boots, to work as per the direction of Engineer in charge. Note : Date of cleaning will be imposed on water tank.
S&F in repairs 300 ltr capacity rotational moulded PVC tank 3 layer in position at any location on top of the building including removing existing tank disconnecting all incoming and out going connections, provision of new fittings including with float valve 15mm bore all as per existing requirements all as specified and directed. Make :Sintex ,polycon , Plasto
S&F in repairs 500 ltr capacity rotational moulded PVC tank 3 layer in position at any location on top of the building including removing existing tank disconnecting all incoming and out going connections, provision of new fittings including with float valve 15mm bore all as per existing requirements all as specified and directed. Make :Sintex ,polycon , Plasto
Supply and fixing in repairs 1000 ltr capacity rotational moulded PVC tank 3 layer in position at any location on top of the building including removing existing tank disconnecting all incoming and out going connections, provision of new fittings including float valve 20mm bore all as per existing requirements all as specified and directed. Make :Sintex, polycon, Plasto
M&L for cleaning of all blockages of Nahani trap/floor trap, bottle trap, gully trap, P or S traps of WCs, 100mm / 75 mm dia CI pipe and stacks upto 1st manhole, CI/SGSW pipe between gully trap and 1st manhole, CI Tee/door bends etc to maintain internal sewage system by employing two sweeper on all working days from 0900 hours to 1700 hours in the Area-IV of AGE B/R (West) Colaba with manual/pressure cleaning pump & flexible rods and other neccessary equipments all as directed by Engr-in-charge. Note - Sweeper must be employed by the contractor as per condition 25 of IAFW 2249 General Condition of contracts for whole currency of work otherwise Rs 1200 Per Day/each recovery shall be levied form the contractor.
All as per item No-134 above but on emergency basis one sweeeper on Sunday / closed holiday /Gazetted holidays on call of Engr-in-Charge/JE. Note -Sweeper must be employed by the contractor as per condition 25 of IAFW 2249 General Condition of contracts for whole currency of work otherwise Rs 1200 Per Day/each recovery shall be levied form the contractor.
Cleaning and desilting of sewage lines of any size any any depth by pumping out /removing liquid waste/sewage, plugging the ends of pipes or diverting the flow into drains if necessary, removing silt, sludge etc, sprinking bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements face mask etc and removing the same(silt,sludge &other waste material) in leak proof trucks covered with tarpoline to outside of MD land all as per existing rules and regulations of civil authorities and flushing the sewer lines with fresh water etc complete all as specified and directed by Engr-in-Charge. If required getting a honey sucker and cleaning the heavily congested sewage line. JCB and other machinery required on special basis would be called on requirement basis.
All as per item No-136 above but 150 mm dia pipe line
All as per item No-136 above but 200 mm dia pipe line
All as per item No-136 above but 300 mm dia pipe line
Cleaning and desilting of manholes depth not exceeding 1.50 meter by pumping out/removing liquid waste/sewage and plugging the ends sewer pipes or diverting the flow into drains if necessary, removing silt, sludge etc, sprinking bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements face mask etc and removing the same(silt,sludge &other waste material) in leak proof trucks covered with tarpoline to outside of MD land all as per existing rules and regulations of civil authorities and cleaning the manholes with freah water etc complete all as specified and directed by Engr-in-Charge . If required getting a honey sucker and cleaning the heavily congested sewage line. JCB and other machinery required on special basis would be called on requirement basis.
Cleaning and desilting of manholes depth exceeding 1.50 m but not exceeding 3.00 met by pumping out/removing liquid waste/sewage and plugging the ends sewer pipes or diverting the flow into drains if necessary, removing silt, sludge etc, sprinking bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements face mask etc and removing the same(silt,sludge &other waste material) in leak proof trucks covered with tarpoline to outside MD land all as per existing rules & regulations of civil authorities and cleaning the manholes with freah water etc complete all as specified and directed by Engr-in-Charge.
Removing/cleaning of chocks/blockages of sewage of any size between manholes at any depth including pumping liquid waste/sewage, plugging and diverting the flow in the drain if necessary using Kampti/cleaning rods, choke removing machine etc and including taking precautionary and safety measures such as use of safety belts, dry cells, torch for lighting inside the manholes and drains etc including drains manholes on either side and sewers passing hole knots disc of required size and sprinkle bleaching powder at places from where they are removed etc complete all as specified
Cleaning the chocks/blockades in AC/CI/PVC soil waste/rain water pipe of any dia by removing cleaning eye and refixing the same after cleaning the pipe, making good damaged cement joints, dia of pipe not exc 150mm dia upto ground/stilt plus four floors including necessay scafolding. Note :- Including removing of trees upto 14th floor and filling of holes with water proofing compound.
All as per item No 143 above but 5th to 8th floor
All as per item No 143 above but 9th floor to 12th floor
S&F in repairs cleanings eye (oval access door) for bends, branches, etc of dia not exc 100mm at any floor level all as specified & directed .
Empting choked up sewage lines and manholes exc 3.00 mtr depth by providing sewage suction vehicle of capacity 5000 ltrs (BMC Pattern) including necessary other arrangments such as sweepers to clean up the site after work and desposing the same at places earmarkd outside MOD land upto 25 KM lead and lift all as specified and directed. Note :- (a) All precautions to be taken by all workers while working in foul condition. Contractor shall take all necessary actions. (b) After cleaning vehicle will be contractors property. (c) Contractor accredated representative shall be available during the cleaning. (d) Complete process shall be completed in all respects within a day.
Cutting into existing manhole for connecting new drain, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC1:2:4 type B1, smooth finished and reforming benching as required for internal pipe of dia 100 mm complete all as specified and directed.
Cutting into existing manhole for connecting new drain, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC1:2:4 type B1, smooth finished and reforming benching as required for internal pipe of dia 150 mm complete all as specified and directed.
Excavating in trenches in hard soil n exc 1.5 m width n exc 1.5 m depth in any type of soil and getting out all as specified and directed.
All as item no 13 above but exc 1.5 m depth all as specified & directed
S&F Reinforced concrete pipes, class NP3, 200 mm dia laid and jointed including complete demolition with collars all as specifed and directed.
S&F Reinforced concrete pipes, class NP3, 150 mm dia laid and jointed including complete demolition with collars all as specifed and directed.
S&F for providing, lowering and laying HDPE DWCPE (SN8) pipes as per IS : 16098 of 2013, 150 ID mm bore, laid and jointed with and including elastomeric sealing 'O' ring as per manufacturer's instructions complete including demolition of existing line all as per specified and directed. Note - The rates include for laying pipes level or to falls in trenches, etc. on concrete bed or directly on hard ground as indicated and making joints and testing as specified.The rates include for all necessary extra joints, waste, and cutting. Make - Prince / Supreme / Astrol
S&F for providing, lowering and laying HDPE DWCPE (SN8) pipes as per IS : 16098 of 2013, 200 ID mm bore, laid and jointed with and including elastomeric sealing 'O' ring as per manufacturer's instructions including demolition of existing pipe complete all as per specified and directed. Note - The rates include for laying pipes level or to falls in trenches, etc. on concrete bed or directly on hard ground as indicated and making joints and testing as specified.The rates include for all necessary extra joints, waste, and cutting. Make - Prince / Supreme / Astrol
S&F for providing, lowering and laying HDPE DWCPE (SN8) pipes as per IS : 16098 of 2013, 250 ID mm bore, laid and jointed with and including elastomeric sealing 'O' ring as per manufacturer's instructions including demolition of existing pipe complete all as per specified and directed. Note - The rates include for laying pipes level or to falls in trenches, etc. on concrete bed or directly on hard ground as indicated and making joints and testing as specified.The rates include for all necessary extra joints, waste, and cutting. Make - Prince / Supreme / Astrol
M&L PCC 1:3:6 type C-2, 150 MM dia using 40 mm graded crushed stone aggregate for Concrete bed to drain pipes including packing under and for hauching & Benching against the sides of pipes after they are laid and tested all as specified and directed Note :- (i) Thickness of bed below the barrel of pipes: 15cm for pipes 200mm dia and over. (ii) Width of bed: Outer diameter of drain pipes (not of sockets/collars) plus 30 cm (iii) The rates include for any necessary shuttering and supports to concrete and for laying beds to falls.
M&L PCC in 1:3:6 type C-2, 200 MM dia using 40 mm graded crushed stone aggregate for Concrete bed to drain pipes including packing under and for hauching & Benching against the sides of pipes after they are laid and tested all as specified and directed. Note :- (i) Thickness of bed below the barrel of pipes: 15cm for pipes 200mm dia and over. (ii) Width of bed: Outer diameter of drain pipes (not of sockets/collars) plus 30 cm (iii) The rates include for any necessary shuttering and supports to concrete and for laying beds to falls.
Returning, filling in including spreading leveling watering and well ramming in layers n. exc 25 cm in soft/loose soil all as specified and directed.
Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point all as specified and directed.
M&L PCC 1:2:4, Solid block size 390x150x230 /600x300x300 mm, built in cement mortar1:6 including demolition all as speified & direted
Material and labour for Except bricks with old sub class 'B' bricks (obtained from demolition) straight curved on plan exc 6 metre mean radius with old size bricks built in CM 1:4 for cracked wall of manholes, septic tank, soak pits all as specified and directed.
M&L Rendering 15mm thick plaster in cement mortar 1:4 on brick or concrete masonry walls, finished even and fair without using extra cement and using 2 % water proofing compound all as specified and directed. Notr- WPC shall be measured and paid for separately as 'Supply only'.
Supply only integral water proofing compound. Make - Fosroc / Sica / Dr Fixit
M&L Rendering 15mm thick plaster in cement mortar 1:4 on brick or concrete masonry walls, finished even and fair without using extra cement including taking down all as specified and directed.
M&L for cement concrete 1:2:4 type B0, (using 12.5 mm graded crushed stone aggregate) as in coping/cills using necessary form work weathering, slightly rounded or chamfered angles and throating all as specified and directed.
M&L for PCC (1:3:6), type C2 (using 40 mm graded crushed stone aggregate ) in foundation filling and mass concrete for bottom of manhole including demolition all as specified and directed.
M&L for RCC (1:2:4), type B1 (using 20 mm graded crushed stone stone aggregate) Precast cement concrete cover slab for manhole and similar article with plain face, set in cement mortar 1:4 including demolition all as specified and direceted.
S&F TMT bars 8 mm dia cut to length bent to shape required including cranking binding with MS wire (annealed) not less than 0.9 mm dia all as specified and as directed. Make - SAIL / JSW / Tata
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement/adhesive including dismantling of existing gully trap with chamber and making new chamber with PCC 1:2:4 type B1 covered with RCC cover all as specified and directed. Make - Prince / Finolex /
S&F in repairs 75 mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls all as specified and directed. Note : upto any height and including necessary scafolding Make - Prince / Finolex
S&F in repairs 110 mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls complete all as specified and directed. Note : upto any height and including necessary scafolding Make - Prince / Finolex /
S&F 75 mm dia PVC (SWR) junction single, (single T) equal or uequal provided with access door all as specified and directed. Make - Prince / Finolex /
S&F 110 mm dia PVC (SWR) junction single, (single T) equal or uequal provided with access door all as specified and directed. Note : upto 5th storey of bldg Make - Prince / Finolex /
S&F 75 mm PVC (SWR) branch piece, single (double Y) equal or unequal all as specified and directed. Make - Prince / Finolex /
S&F 110mm PVC (SWR) branch piece, single (double Y) equal or unequal all as specified and directed. Make - Prince / Finolex /
S&F 75 mm dia PVC (SWR) vent cowl all as specified and directed. Make - Prince / Finolex /
Cleaning of open drains completely by removing silt, soil, mud sludge, vegetation growth and removing the same to out side MoD land all as directed by Engr-in-Charge for width of drains n. exc. 30 CM .
Cleaning of open drains completely removing silt, soil, mud sludge, vegetation growth and removing the same to out side MoD land all as directed by Engr-in-Charge for width of drains exc. 30 cm but n.exc. 60 cm .
Cleaning of open drains completely removing silt, soil, mud sludge, vegetation growth and removing the same to out side MoD land all as directed by Engr-in-Charge for width of drains exc. 60 cm but n.exc. 75 cm .
Cleaning of drains/culverts including removing & re-covering of RCC/CI/Steel covers by completely removing silt, soil, mud sludge, vegetation growth and removing the same to out side MoD land all as directed by Engr-in-Charge for width of drains n. exc. 30 cm.
Cleaning of drains/culverts including removing & re-covering of RCC/CI/Steel covers by completely removing silt, soil, mud sludge, vegetation growth and removing the same to out side MoD land all as directed by Engr-in-Charge for width of drains exc. 30 cm but n.exc. 60 cm .
Cleaning of drains/culverts including removing & re-covering of RCC/CI/Steel covers by completely removing silt, soil, mud sludge, vegetation growth and removing the same to out side MoD land all as directed by Engr-in-Charge for width of drains exc. 60 cm but n.exc. 75 cm.
M&L heavy duty durable parking tiles exc 0.16 but n exc. 36 sqm area with 12-14 mm thick colour in floors etc. with and including 50 mm thick in CM (1:6) bedding set and jointed in neat cement slurry and pointed in coloured cement to match the shade of the tiles including dismantling all as specified and directed by Engineer in charge. Make - Johnson / Kajaria
M&L Machine pressed precast concrete interlocking paver block of any shape and size and colour confirming to IS 15658-2006 of 25/30 mm and over in thickness, M-35 Grade laid over 50 mm thick sand cushioning including dismantling all as specified and directed. Make - Vitco or equivalent
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) as directed and specified.
M&L for framed work such as grills, gratings with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and directed.
S&F in repairs 900mm x 600mm FRP manhole cover of 8 tonne loading capacity with frame over manhole coping concrete all as specified and directed. Make - Vikrant or equivalent
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
S&F cast iron manhole covers alongwith frame grade A-35 T/A-350 KN, machined each exc 5 Kg by weight all as specified and directed by EIC. Make - Neco
RUPESH CONSTRUCTION CO
HINDUSTAN BUILDERS
Unitech Enterprises
NATH CONSTRUCTION
SB CONSTRUCTION
SHRI SAI ENTERPRISES
SAHU AND SAHU CO.
Bidder Name
Unitech Enterprises
HINDUSTAN BUILDERS
SAHU AND SAHU CO.
NATH CONSTRUCTION
SHRI SAI ENTERPRISES
Bright Construction Co
SB CONSTRUCTION
RUPESH CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .