| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.7 L+₹43,170 (1.53%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹29.6 L+₹1.3 L (4.68%)Rejected-AOC 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L3 | Rejected-AOC L3 | |
| 4 | L4₹31.3 L+₹3.1 L (10.8%)Rejected-AOC NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L4 | Rejected-AOC L4 | |
| 5 | L5₹35.8 L+₹7.5 L (26.7%)Rejected-AOC NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L5 | Rejected-AOC L5 |
Tender Value
₹28.7 L
EMD Value
₹57,480
Closing Date
23 Oct 2024, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
SPECIAL REPAIRS AGAINST BER COOLING APPLIANCES AND TRANSFORMERS AT AFS YELAHANKA
2024_MES_676643_1
8289/E8
Open Tender
Civil Works
Item Rate
180 days
Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹57,480
Yes
7 Dec 2024
25 Sept 2024
30 Oct 2024
25 Sept 2024
23 Oct 2024
9 Oct 2024
Amount
Supply, install, testing and commissioning hi wall invertor split units indoor/outdoor with invertor compressor with adjust power depending on load complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating As per BEE guidelines and ISEER Value not less than 3.90 for air conditioner of capacity 1.5 TR including dismantling of old unserviceable 1.5 TR capacity from existing location and depositing it to MES store yard complete all specified and directed. Make : Lloyd/Blue star / Hitachi
Supply, install, testing and commissioning hi wall invertor split units indoor/outdoor with invertor compressor with adjust power depending on load complete with cordless remote control unit and within built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating as per BEE guidelines and ISEER Value 3.95 for air conditioner of capacity 2 TR including dismantling of old unserviceable 1.5 TR capacity from existing location and depositing it to MES store yard complete all specified and directed Make : Lloyd/Blue star / Hitachi
Supply, install, testing and commissioning hi wall invertor split units indoor/outdoor with invertor compressor with adjust power depending on load complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating as per BEE guidelines and ISEER Value 3.93 for air conditioner of capacity 1 TR including dismantling of old unserviceable 1 TR capacity from existing location and depositing it to MES store yard complete all specified and directed Make : Lloyd/Blue star / Hitachi
Supply, install, testing and commissioning hi wall invertor split units Twin indoor and single outdoor with Twin invertor compressor with adjust power depending on load complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating As per BEE guidelines and ISEER Value 4.05 of capacity 3 TR including dismantling of old unserviceable 3 TR capacity from existing location and depositing it to MES store yard complete all specified and directed. Make : Lloyd/Blue star / Hitachi
Supply, install including testing of refrigerator of capacity 195 Ltrs with digital invertor technology, 230 volts electric driven, single phase AC supply, Single door , with minimum BEE 3 star rated including dismantling of old unserviceable refrigerator of similar capacity from existing location and shifted to MES store yard complete all specified and directed Make : Samsung/LG/Lloyd
Supply, install including testing of refrigerator of capacity 310 Ltrs with invertor technology, frost free, convertible, 230 volts electric driven, single phase AC supply, double door, minimum BEE 3 star rated including dismantling of old unserviceable refrigerator of similar capacity from existing location and shifted to MES store yard complete all specified and directed Make : Samsung/LG/Lloyd
Supply, install including testing of refrigerator of capacity 360 Ltrs with digital invertor technology, 230 volts electric driven, single phase AC supply, double door , with minimum BEE 3 star rated including dismantling of old unserviceable refrigerator of similar capacity from existing location and shifted to MES store yard complete all specified and directed by Engr-in-Charge. Make : Samsung/LG/Lloyd
Supply, install including testing of Deep freezer glass top upto 320 Litre capacity having double door minimum BEE 3 star rated including dismantling of old unserviceable deep freezer 320 litre capacity from existing location and shifted to MES store yard complete all specified and directed Make : Blue star /Voltas/ Lloyd
Supply, fixing, jointing and testing copper tubing with nominal diameter 1-1/4 inch of thickness not less than 1.2mm for liquid line to connect without door unit complete all as specified and directed
Supply, fixing jointing and testing copper tubing with nominal diameter 3/8 inch of minimum thickness not less 0.9mm including expanded polythene foam insulation for external insulation of suction line for connecting with outdoor condensing unit complete all as specified and directed
M&L for fabrication of base stand made from MS angle iron of size 50mmx50mm, 6mm thick including necessary nuts, bolts & washers for mounting of outdoor unit of 1.5/2 TR capacity Split AC including painting with two coats of metal paint over one coat synthetic enamelled black paint complete all as specified and directed
S&F PVC non-metallic flexible pipe of size 20mm dia alongwith fixing accessories such as saddles, pipe hook etc, for draining out the water from indoor unit complete all as specified and as directed
M&L for sub-main wiring with two runs of 4 sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing capping of suitable size and fixing accessories should be concealed/fixed to wall/roof/floor and including suitable PVC casing capping with 4 sqmm copper earth wire after taking out the existing sub-main wiring, making good to the disturbed surfaces also matching the existing surfaces all as specified and directed. Note: 2 runs of cable and one run earth wire and conduit/casing Capping will be measured as one length. Three run of 4 Sq mm and PVC conduct/ Casing capping is measured as one Run or one Meter.
S&F in repair MCB Single pole, 230 volts, 20 Amps, 'B' Curve, 10 KA, including disconnecting, taking down old/unserviceable, MCB Single pole and Neutral complete all as specified and as directed
M&L for fix in replacement of PVC AC/ box with 20 Amp MCB DP , socket and plug top , PVC , 3 Way complete all as specifeid and directed. Make Havells Product code DHDBCDP025201603 or equivalent in Legrand / Anchor
Supply , install, testing and commisioning of invertor type ductable air conditioning system , of capacity miniumum 7.5 TR ,comprissing of indoor and outdoor unit with invertor compressor of capacity miniumum 7.5 TR capacity with R-410A Gas as refrigerant complete all as specified and directed with following items :- (i) CPVC drain piping of size 32mm from indoor units till nearest drain points with necessary bends and fittings as per site requirement. (ii) MS Stand for Outdoor ductable unit duly painted with two coats of red oxide over a coat of black synthetic enamel paint as per site requirement . (iii) Cable of size 4Cx 2.5 Sqmm from outdoor unit to indoor unit as per recemmendation of OEM as required at site. (iv) Power cable of size 4C x 10 Sqmm from nearest power source to outdoor unit as per recemmendation of OEM as required at site. (v) Open and closed cell nitrile rubber for acuastic insulation of thickness 10mm for insulation of copper tubing from outdoor unit to indoor unit as per site requirements. (vi) GI volume control dumper of suitable size as per recommendation of OEM and as required at site. (vii) Grills with collar damper of suitable size as per recommendation of OEM as as required at site. (viii) Fire retardent flexible canvas connection as per recommendation of OEM and as required at site. (ix) Installation of factory made GI Duct of size 24G/22G with angle flanges / support , joints , gasket , bolts & nuts etc compete all as per recommendation of OEM and approved by accepting officer . Location :112 HU Contd to 16.01
Make : Blue Star Model No DSAI-961R3B or equivalent in Hitachi / Lloyd/LG. Note : (i) Contractor has to submit the layout drawings of Ducts as per recommendation of OEM and get approval of same before commisioning of plant from Accepting officer. (ii) Cotractor has to carryout nitrogen pressure test after commisioning of plant and has to submit the test report to EIC duly signed by rep of OEM. (iii) Necessary PCC Work required for fixing of stand including making holes in wall deemed to be included in quoted rate nothing extra will be paid to the contractor for this. (iv) Quoted deemed to be inclusive of complete dismantling of existing UNSV ductable air conditioner (indoor/ Outdoor Unit), transporting and depositing to MES store yard. (v) The work shall be got executed (installed and commissioned) by the authorized representative of manufacturer. The rate quoted deemed to be inclusive of this provision.
chowdeshwariconstructionco (BID ID -3147681)
G K CONSTRUCTIONS (BID ID -3141363)
UNIVERSAL ENGINEERING (BID ID -3141088)
M/S SRI BALAJI ENTERPRISES (BID ID -3141324)
devan enterprises (BID ID -3141017)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .