Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC 11 753 1 HABIBULLA STREET KADAPA CUDDAPAH ANDHRA PRADESH 516001 | Y S R | ANDHRA PRADESH | 516001 | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹22.5 L+₹5.2 L (30.1%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹24.2 L+₹6.9 L (39.9%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹24.6 L+₹7.3 L (42.2%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE |
Tender Value
Refer Docs
EMD Value
₹52,600
Closing Date
7 Dec 2020, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NDA KHADKWASLA
GE NDA KHADKWASLA
REPAIR AND MAINTENANCE OF WATER SUPPLY DISTRIBUTION PIPE LINES AND CONNECTED ITEMS OF EXTERNAL WATER SUPPLY AT NDA KHADAKWASLA
2020_MES_394852_1
GE (K) 32 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
GE NDA KHADKWASLA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE NDA KHADKWASLA
₹52,600
Yes
16 Mar 2021
12 Nov 2020
9 Dec 2020
13 Nov 2020
7 Dec 2020
23 Nov 2020
14 Nov 2020 - 22 Nov 2020
60 days
Amount
Excavation in trenches in soft / loose soil not exceeding 1.5 metre wide and not exc 1.5 metre in depth and getting out for taking out / laying of pipes and making bottom surfaces of excavation leveled.
Ditto as per item No. 2 above but additional depth exc 1.5 mtr and not exc 3.0 mtr beyond the first 1.5mtr
Excavation in trenches in soft hard dense /Hard rock with mechanical chiesling exceeding 1.5 metre wide and not exc 1.5 metre in depth and getting out for taking out / laying of pipes and making bottom surfaces of excavation leveled.
Returning, filling in trenches with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as directed by the Engineer-in-Charge.
Removing surplus soil / spoil to a distance not exceeding 50 metre away and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed by the Engineer-in-Charge.
Taking up or down Cast Iron/ Ductile Iron water mains of following sizes of any class ( incl all fittings) , with spigot and socket ends and any type of joints,keeping in safe custody for reuse of serviceable pipes after necessory cleaning.size of CI/DI pipe 300/450/400 mm
Ditto as per item No. 6 above but size of CI/DI pipe 80/100/150mm bore
Laying only in trenches CI/DI pipes of any class spigot and socket end of size of pipe 300/450/400 mm bore.CI/DI pipe obtained against item No 6 shall be used including provn of rubber packing of suitable size and grade all as directed by the Engineer-in-Charge.
Ditto as per item No. 8 above but size of CI/DI pipe 80/100/150mm bore
Cutting cast iron / Ductile iron pipes in position and reducing to required length for insertion of new tees,branches, Mechanical Joints etc, all as directed. Size of pipe 300/450/400mm bore
Ditto as per item No. 10 above but size of CI/DI pipe 80/100/150/200mm bore.
Repairs to leakage run lead joint in position of size 300/450/400 mm CI/DI pipes by burning out existing joints,recovering lead, cleaning internal surfaces of socket and providing new joints with using recovered lead and additional new lead, making joint leak proof.(Excavation of Earth work shall be measured and paid seperately)
Ditto as per item No. 12 above but Size of CI/DI pipe 80/100/150/200mm
M & L for MS Special fitting of IS 1239 and thickness not less than 7mm fittings any type spigot and socket ends or flanged pipe as required at site (such as bend, taper, Tee, flange, socket etc) Socket end/ flanged as ordered of any size from 80mm to 450mm as required at site. (i) The weight of the fittings shall be measured and paid as given in relevant IS or actually provided which ever is less. (ii) All fittings shall bear relevant IS stamping marking. (iii) Excavation and earth work shall be measured and paid separately. (iv) Cost of the joints and jointing materials shall be deemed to be included in the relevant items of DI pipes here-in-before.
Taking up or down 80/50/40 mm bore GI water tubing and connections of pipe and fittings including segregating of serviceable pipes and keeping in safe custody for reuse in the work and removing unserviceable pipes and fittings from site of work complete all as directed by the Engineer-in-Charge.
Ditto as per item No. 15 above but but of size 15/20/25 mm
S & F GI tubing 'Medium grade' 80 mm bore, with all fittings claimps screws MS clamps, hooks complete on laying of ground/fixed on wall/floor/ceiling all as specified and as directed. Make Tata/Jindal/Prakash
Ditto as per item No. 17 above but of size 50 mm
Ditto as per item No. 17 above but of size 40 mm
Ditto as per item No. 17 above but of size 25 mm
Ditto as per item No. 17 above but of size 20 mm
Ditto as per item No. 17 above but of size 15 mm
Laying only in trenches, in old or new position, old GI pipes after necessory cleaning internally and externally both, returning the old screw threads and replacement of all old fittings of size of pipe 80/50/40mm. (Serviceable pipes obtained against item No 15 shall be used.)
Ditto as per item No. 23 above but size of pipe 15/20/25mm.and seviceable pipe obtained from item No 16 shall be used
S & F in repairs of Bronze/GM gate valves (Hexagonal type) 50mm with iron wheel head, screwed both ends for iron pipes.
Ditto as per item No. 25 above but of size 40 mm.
Ditto as per item No. 25 above but of size 25 mm.
Ditto as per item No. 25 above but of size 20 mm.
Ditto as per item No. 25 above but of size 15 mm.
S&F in repairs for bib tap standard of PTMT any colour of size 15mm high pressure screwed for iron pipe and fixed. (Minimum weight 90gms). Including taking out old bib tap.
S&F in repairs for Stop valves of PTMT any colour, 15mm, screwed for pipes high pressure, (Minimum weight 90gms) including taking out old one
S&F in repair ball (float) valves high pressure made of brass with epoxy coated brass rod and high density plastic ball, screwed for 25mm bore iron pipe, including replacement of adjacent GI fittings (socket, nipple,reducer socket,etc.) where necessary complete.
S&F in repair ball (float) valves high pressure made of brass with epoxy coated brass rod and high density plastic ball, screwed for 20mm bore iron pipe, including replacement of adjacent GI fittings (socket, nipple,reducer socket,etc.) where necessary complete. Make : Prayag / Polytuff
S & F in repair ball (float) valves high pressure of brass with epoxy coated brass rod and high density plastic ball, screwed for 15mm bore iron pipe, including replacement of adjacent GI fittings (socket, nipple,reducer socket,etc.) where necessary complete, Make : Prayag / Polytuff
Dismantling and taking out from its position existing unserviceable sluice valve of any size (80mm to 150mm) by unscrewing of nut & bolts rectified the defect like that up and down of gate, tightely operated of spindle etc complete and after rectifed the defect re-installed at the same as per direction of Engineer-in-charge.
Taking down unserviceable sluice valve from existing position and supply and fixing butterfly valve of 300mm dia with actuator (gear box operated), gear must be operated quastor from worm gear box high performance, robust construction compact design, torque range from worm gear box high performancerobust construction compact design, torque range from 245nm to 7357nm self locking mechanism (worm and worm wheel), IP67 enclosure, staainless steel shaft graded cast iron housing and worm wheel in ductile iron/SS, high tensile faster, high performance bearings, sturdy hand wheel with black powder coating for easy and smooth operation gear boxex lubricated with multipurpose frease and gear box mounting as per ISO 5211std. with including necessary arc/gas welding with flange as per existing pipe line , tail pics of MS Pipe as per site requiredment not less than 350mm length, dia of tail pics as per existing pipe ,stenless steel spendle not less than 2mtr length including suitable size nuts, bolts, washer and rubber gasket all as required and directed at site.
Ditto all as per item No. 36 above but of size of butterfly gear operated valve 250 mm
Ditto all as per item No. 36 above but of size of butterfly gear operated valve 200 mm
Ditto all as per item No. 36 above but of size of butterfly gear operated valve 150 mm
Demolition Brickwork or stone/boulder masonry, built in cement mortar of any description and at any situation as ordered, Removing materials from site.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius and built in cement morter (1:4) as in repair/raising /making of valve pit chamber.
M & L for rendering 15mm thick plaster on fair faces of brick work or concrete surfaces with CM (1:4).
M&L for cutting existing road including black top cover (trench) up to 1 Mtr depth and width not exc 30cm for laying of pipe line, refilling and making good after laying of pipe with removed soil and finally sealed with cement concrete of thickness not less than 150mm to match with the top surface of Road.(Cement concrete shall be measured and paid seperately under appropriate item)
Demolition of cement concrete of any description and in any position, removing demolished material from site, filled up the disturbed concrete surfaces with cement conctete as orded.(Cement concrete shall be measured and paid seperately under appropriate item)
M&L for cement concrete (1:2:4) type C2 (Using 40mm stone aggregate), as in repairs to RCC pipe line/ Valve pits / disturbed hard standing or any other repair as required at site at any situation complete all as specified as directed.
Repairs to leakage run lead joint in position of size 450/400 mm CI/DI pipes by burning out existing joints,recovering lead, cleaning internal surfaces of socket and providing new joints with using recovered lead and additional new lead, making joint leak proof.(Excavation of Earth work shall be measured and paid seperately)
Cutting chases on brick wall/ stone masonary / Plint protection of building for concealed water tubing and making good , with CM (1:3), cutting exc 10cm but not exc 20cm girth.
S & F mechanical split coller joint ( six pieces joint ) including follower gland, gaskets,nuts and bolts for MJ ends of size upto 500 mm for repairs to CI / DI pipeline damaged during breakdown complete all as specified and directed by Engineer- in- Charge
S & F mechanical flanged joint including follower gland, gaskets,nuts and bolts for MJ ends of size 400/300/250 mm for repairs to CI/DI pipeline damaged during breakdown all as specified and directed by Engineer- in- Charge
Ditto all as per item No. 49 above but of size 200/150/80 mm bore
S & F in repairs foot valve with ball arrangement and CI body flanged type of size 150 mm size heavy grade of make Normax or equivalent complete all as specified & directed by Engineer-in-Charge.
Supply, febricate and fixing MS framed grills,gratings, framed guard bars,ladder, framework of Valve pit cover, water tanks etc, or similar work as ordered and febricated from MS rolled section of any size and shape as directed and fixed at position with all fixing accessories complete. (Fixing of MS sheet where required shall be measured and paid seperately)
M&L for MS plate/sheet plain or chequered, 3.00 mm thick cut to pieces as required and fixed to MS frame work by means of Electric arc/gas welding complete all as directed and specified.
M&L for preparation of new metal surfaces of any description, over 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide.
M&L for preparation old painted metal surfaces of any description, over 10cm in width or girth and applying one coat of synthetic enamel paint.
Taking down old and unserviceable Rotational moulded polyethylene water storage tanks and S & F new Rotational moulded polyethylene water storage tanks double layer (cylindrical vertical with closed top) of capacity 5000 ltrs , hoisted and fixed in position and connecting to water incomming pipe line including all fittings such as top cover, all as specified in SSR Part I
Taking down old unsv non return valve and Supply & fix in repairs for Non Return Valve heavy duty of size 100mm Class PN 1.6 and fixed complete.
S & F illuminated display board of size 1.25mx0.2mx0.9m (LXBXH) with flex of light blue (MES Colour ) clour of letters shall be white, outerside febrication bordered with aluminium angle frame of 25mmx25mmx3mm thick, innerside febricated with 12mm MS square bar, 50mm dia GI Pipe medium grade shall be fixed both side of board with 2 nos 30mmx4mm thick MS Flat of 2m length welded to GI Pipe and nut bolt and washer with display board not less than 3m and PCC (1:4:8) for foundation including all internal wiring s and illuminated with LED 40W Tubelight fittings 01 Nos SMC/FRP junction box 140mmx140mmx95mm inner dimension make sintx cat part No GSJB-1414 Make bajaj Cat pat No BCLAB 20W/wipro/havells including its fixing arrangement and written letters in capital not less than 10 letters more than 40 letters, size of letters proportion with overall size of baord complet all as specified and as directed . Note (i) Before manufacturing boards drawing and design of board including colour of board shall be approved by Engineerr-in-Charge (ii) Each board display name shall be given seperately
S & F PVC insulated copper conductor 3 core 2.5sqmm for flood light from sintex box to flood light, multistranded complete all as specified and directed. Make : Polycab/Havells/KEI
S & F junction box of 250mm x20mmx105mm size with connector for connection incommming and outgoing of cables including 01 nos MCB DP 10amp to control the pole light circuit and MS Brackets for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incomming and outgoing cables Make : Sintex model GSJB2520 complete all as specified and directed by Engineer-in-charge
Dismentiling carefully all water connections, decoping of submersible pumps 26HP taking out from foundation and transporting pump body to workshop for necessary machining/servicing works as directed and reqd and reinstalling the pump to its original position and commissioning etc
M & L for submersible flat cable 3 core, 1100 volt, 4.0 sqmm insulated and sheathed with PVC confirming to IS: 694 complete all as specified and directed Make Havells/Polycab
S & F taflon gland packing not less than 15mm dia as per existing size complete all as specified and directed by Engineer-in-charge
Cleaning of internal side UG sump with the help of rubbing tools/matalic brush and finish the surface as per instruction of water proofing expert.
M&L of internal side of UG Sump for apply the primer two coat of polyalk EP and cement slurry as per ration 2:1 by weight mix thoroughly perferably using a mechanical mixer , fill the cracks/ honycombed with polymer modified morter ,repair all construction joint area and debonded surface with polymer modified morter, make water proof fillet (WATTA) at the junction of horizontal slab and vertical wall all arond, fill the gape around periferi of outlet/inlet pipe using polymer modified mortor Slurry of consistency easily applicable by brush is ready for use as a bonding materials. Apply the bonding coat on the cleaned RCC surface by brush taking care to avoid pinholes. finish the surface as per instruction of water proofing expert
M&L of internal side of UG Sump for apply the three coat of polyalk WP and cement slurry as per ration 1:1 by weight mix thoroughly perferably using a mechanical mixer . Slurry of consistency easily applicable by brush is ready for use as a bonding materials. Apply the bonding coat on the cleaned RCC surface by brush taking care to avoid pinholes, necessary to sandwich the cured coating of PLYALK WP with a screed layer,test conducted on a concrete cube coated with POLYALK WP cement slurry as per DIN 1048, confirms to flexiblility and adhession test as per IS 10.1, finish the surface as per instruction of water proofing expert and test condu. Note : (i) after first coat apply two more coats of similar slurry at 24 hrs intervals (ii) Allow to set for 48 hours (iii) Cure the coating for 7 days by sprining water three times a day on the vertical surface and by moist gunny bags on the horizontal surface. (iv) Filling the water in above said UG sump up to full tank & keeping it for 48hrs under observation aftertreatment of whole surface in the Sump.
Mourya Construction
M/S JEELANI ELECTRICALS
G V HAGAWANE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .