Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC NO 229 ANGAPPAN STREET MITTANAMALAI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | ₹18.3 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹19.2 L+₹84,750 (4.62%)Rejected-AOC | ₹19.2 L+₹84,750 (4.62%) | L2 | Rejected-AOC L2 |
| 3 | L3₹22.3 L+₹3.9 L (21.4%)Rejected-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | ₹22.3 L+₹3.9 L (21.4%) | L3 | Rejected-AOC L3 |
| 4 | L4₹23.2 L+₹4.9 L (26.5%)Rejected-AOC | ₹23.2 L+₹4.9 L (26.5%) | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
17 Apr 2021, 6:00 pmClosed
Garrison Engineer (I) (P) Fy Avadi Chennai 600054
Garrison Engineer (I) (P) Fy Avadi Chennai 600054
SPECIAL REPAIR TO LT PANEL BOARD WITH APFC PANEL AT CQA HV UNDER GE I P FY AVADI
2021_MES_421189_2
8594/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (I) (P) Fy Avadi Chennai
As per Tender documents
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer (I) (P) Fy Avadi
₹40,000
Yes
27 Apr 2021
24 Mar 2021
22 Apr 2021
24 Mar 2021
17 Apr 2021
5 Apr 2021
25 Mar 2021 - 3 Apr 2021
Amount
Taking down the old unserviceable LT pannels with all connected controls with capacitors, metering equipments, etc complete after dismantling/taking out of all incoming and outgoing cables all as specified and directed.
Supply , install, testing and commissioning (after reconnecting of all incoming and outgoing cables) of cubical housing cabinet type LTpanel of size 1500 mm ((H) x 1000 mm (B) x 600 mm (D) indoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 2 mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved and built upon 50 x 50 x 6 mm size angle iron frame work , having front and rear hinged doors, lifting locks (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. Necessary foundation work as required at site and comprising following:- Note : (i) Quoted rate deemed to include for necessary earth work, PCC foundation mounting bolts and nuts as spcified and directed by Engr-in-chare.(ii) Bimetal sheet (one side copper and other side aluminium) to be used for connecting the Aluminium lugs with copper busbar.
BUS BAR : Electrolytic grade high conductivity TP&N solid copper bus bars, rated 1600 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - 04 Nos
INDICATING DEVICES : (a) LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3 (b) Digital Voltmeter (Make AE/L&T) - 01 No (c)Current Transformer having Ratio 1000/5, 15 VA - 01 Set of 3 (Make :Kapa or equivalent. ) (d) Digital Ammeter ( Make(AE/L&T) - 01 No
CONTROLS : (a) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1000 Amps - 01 No (Incomming) (b) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps - 02 Nos (Outgoing) - For Lab & Ph II Bldg.
Supply , install, testing and commissioning (after reconnecting of all incoming and outgoing cables) of cubical housing cabinet type LT panel of size 1500 mm (H) x 1000 mm (B) x 600 mm (D) indoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 2 mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved and built upon 50 x 50 x 6 mm size angle iron frame work , having front and rear hinged doors, lifting locks (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. Necessary foundation work as required at site and comprising following:- Note : (i) Quoted rate deemed to include for necessary earth work, PCC foundation mounting bolts and nuts as spcified and directed by Engr-in-chare.(ii) Bimetal sheet (one side copper and other side aluminium) to be used for connecting the Aluminium lugs with copper busbar.
BUS BAR : Electrolytic grade high conductivity TP&N solid copper bus bars, rated 1600 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - 04 Nos
INDICATING DEVICES : (a) LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3 (b) Digital Voltmeter (Make AE/L&T) - 01 No (c)Current Transformer having Ratio 1000/5, 15 VA - 01 Set of 3 (Make : Kapa or equivalent. ) (d) Digital Ammeter ( Make(AE/L&T) - 01 No
CONTROLS : (a) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1000 Amps - 01 No (Incomming) (b) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps - 01 No (Outgoing) - For Workshop (c) 4 Pole MCCB 400 Amp, fixed thermal megnetic, 50 Hz, 415 V with rupturing capacity 36 KA - 01 No (Outgoing) - For Adm Bldg
Supply , install, testing and commissioning (after reconnecting of all incoming and outgoing cables) of cubical housing cabinet type LT automatic power factor control panel of size 2000 x 1950 x 600 mm (Indoor type), platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 2 mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved and built upon 50 x 50 x 6 mm size angle iron frame work , having front and rear hinged doors, lifting locks (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. Necessary foundation work like PCC Fdn, bolts, nuts etc as required at site and comprising following:- Note : (i) Quoted rate deemed to include for necessary earth work, PCC foundation mounting bolts and nuts as spcified and directed by Engr-in-chare.(ii) Bimetal sheet (one side copper and other side aluminium) to be used for connecting the Aluminium lugs with copper busbar.
BUS BAR : Electrolytic grade high conductivity TP&N solid copper bus bars, rated 1600 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - 04 Nos
CONTROLS: (a) MCCB, 4 pole, 630 Amps, 50 KA, Fixed thermal magnetic setting – 01 No. (b) APFC relay 12 stage with inbuilt power factor meter - 01 No (Make : L & T) (c) Timer ON delay timer - 01 No (d) AUX contractor 12 NO/12 NC, Make : L & T (e) Control MCCB, 3 pole, 200 Amps, 25 KA, fixed thermal, 415 V, 50 Hzr - 03 Nos (f) Control MCB, 3 pole, 100 Amps, 415 V, 50 Hzr - 03 Nos (g) Control MCB, 3 pole, 63 Amps, 415 V, 50 Hzr - 03 Nos (h) Control MCB 32 Amps, 3 pole, 10 KA - 03 Nos (i) Control MCB 6 Amps, SP 10 KA - 12 Nos (j) Capacitor bank 5 KVAR - 02 Nos (k) Capacitor bank 10 KVAR - 02 Nos (l) Capacitor bank 15 KVAR - 03 Nos (m) Capacitor bank 25 KVAR - 03 Nos (n) Capacitor bank 50 KVAR - 02 Nos (o) Current transformer 600/5 - 03 Nos to be installed in existing transformer LT panel board, Make : Kapa or equivalent. (p) Copper control cable with copper lugs at both ends, armoured, 2.5 sqmm, 6 core, required for connection from LT panel to APFC panel - 12 Rm (approx)
Supply laying in existing trenches/cable ducts and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric heavy duty 1100V grade with aluminium conductor of size 300 Sqmm X 3½ core. Note : Quoted rate deemed to include for fixing cable ends to panel/transformer/APMC panel etc with suitable aluminium lugs / bimetal sheet lugs as required and as specified and directed by Engr-in-charge.
HARI ENTERPRISES
PSK Enterprises
Global Safety Engineering and Management Solutions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .