Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.1 LAccepted-Finance 19 RAMESH NAGAR LALIT APARTMENT JAI BHAVANI MATA ROAD VILLAGE TOWN AMBOLI VILLAGE CITY ANDHERI WEST MUMBAI | 1 | Accepted-Finance Accepted |
Tender Value
₹19.2 L
EMD Value
₹38,364
Closing Date
13 Jun 2023, 6:00 pmClosed
EE(E)
The Executive Engineer (E), BSNL Electrical Division, 1st floor, Cantonment Exchange Bldg., MHS Compound, Near Poona Club, Opp. ISKCON Temple, Camp, Pune-411001
Operation and Comprehensive Maintenance of Electromechanical services at Telecom compound MHS Bhavan Pune SH Attending pending defects in substation at risk and cost of MS Abhay Air Conditioning Services Agreement No 18.EEE.BSNL.PN.2019-20)
2023_BSNL_154842_1
04/EEE/BSNL/PN/ 2023-24
Open Tender
Electrical Works
Item Rate
60 days
MHS Pune
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
AO(Cash) BSNL Pune
₹38,364
22 Jun 2023
22 May 2023
22 Jun 2023
22 May 2023
13 Jun 2023
22 May 2023
Amount
Servicing of following Capacities of Air Circuit breakers including the following :- 1) Removal of ACB from the panel. 2) Thorough cleaning of dust, spider webs, foreign particles etc from the ACB. 3) Complete removal of old grease from various parts. 4) Cleaning of all parts with scrubbers and cleaning agents. including arranging for consumables like rags, scrubbers, Cleaning spray CRC 2-26 OR spray 55, special greases lithon-2 and balmerol mole grease etc. 5) Checking the settings and gaps of arcing contacts, releases using various gauges. 6) Verifying the presence of all hardware and their tightness. 7) Identifying the missing or damaged parts and replacing them. 8) Regressing with recommended special greases. 9) Reassembling and prefixing the breaker in the panel. 10) Carbon paper test/gauges for arcing contacts. 11) Checking for satisfactory Electrical and mechanical operations complete as required.
A) 5000A ACB Make L&T Model CN-CS 5000H
B) 2500A ACB Make L&T Model CN-CS 2500H
C) 1600A ACB Make C &S
D) 1200A ACB Make C &S
E) 1000A ACB Make L&T Model CN-CS 1000C
Servicing of 22kV Vacuum Circuit breakers including the following :- 1) Removal of VCB from the panel. 2) Thorough cleaning of dust, spider webs, foreign particles etc from the VCB. 3) Complete removal of old grease from various parts. 4) Cleaning of all parts with scrubbers and cleaning agents. including arranging for consumables like rags, scrubbers, Cleaning spray CRC 2-26 OR spray 55, special greases lithon-2 and balmerol mole grease etc. 5) Checking the settings and gaps of arcing contacts, releases using various gauges. 6) Verifying the presence of all hardware and their tightness. 7) Identifying the missing or damaged parts and replacing them. 8) Regressing with recommended special greases. 9) Reassembling and prefixing the breaker in the panel. 10) Checking for satisfactory Electrical and mechanical operations complete as required.
Replacement of LED type indications Lamps in the existing panel including necessary removal of old lamp and installation of lamps for satisfactory operation etc complete as required
i) Red colour
ii) Yellow colour
iii) Blue colour
Replacement of following accessories and meters in the existing panel including necessary removal of Faulty components and installation for satisfactory operation etc complete as required
ii) Digital Ammeter
iii) Multifunction meter
iv) Ammeter
v) CT 200/5Amp
vi) Voltmeter
vii) kwh meter
Replacement of following accessories and in the existing capacitor panel including necessary removal of Faulty components and installation for satisfactory operation etc complete as required
i) MNX 225 contactor
ii) MNX 80 contactor
iii) MNX 50 contactor
iv) Timer in Cap Panel
v) APFC
vi) 63Amps Switch Fuse Unit Make M/S L&T FN63
vii) 25kVAR Capacitor
Supplying and Fixing of following MCCBS in the existing panel, including making necessary modifications to the busbar and making connections, testing, commissioning etc complete as required.
i) 4pole 400Amps MCCB
ii) 4pole 630Amps MCCB
Replacement of rotary mechanism of following capacities MCCB including making necessary modifications to the panel if required and making necessary connections, testing, commissioning etc complete as required.
1) 4pole 630Amps MCCB Make M/S L&T
2) 4pole 400Amps MCCB Make M/S L&T
3) 4pole 250Amps MCCB Make M/S L&T
Replacement of following accessories and in the existing Air Circuit Breakers including necessary removal of Faulty components and installation for satisfactory operation etc complete as required
i) ACB drawout handle
ii) ACB door frame
iii) 415volts UV coil
iv) ACB mechanical interlock
v) Operating Handle
Replacement of following capacity HRC fuse links in the existing SFU in panel including necessary testing commissioning etc complete as required.
1) HRC fuse links 32Amps
2) HRC fuse links 63Amps
3) HRC fuse links 100Amps
4) HRC fuse links 250Amps
Replacement of following capacity 4pole changeover switch in the existing panel including making necessary modifications to the panel for satisfactory operation etc complete as required
Rewinding of existing exhaust fans installed for ventilation in MV panel, including necessary removal of the fans from the panel, to and fro transportation to rewinding workshop and reinstallation for satisfactory operation in the MV panel complete as required.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .