Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹42.1 L+₹2.8 L (7.03%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹43.6 L+₹4.2 L (10.8%)Rejected-Finance V PO RAIKO KI DHANI NAWAJI KA PANA BHURTIYA DISTT BARMER RAJ PIN 344001 | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance Other than Lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Documents not uploaded as per NIT | |
| 5 | Rejected-Technical | - | Rejected-Technical Documents not uploaded as per NIT |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
12 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (A) Jaisalmer
HQ CWE (A) JAISALMER-345001
PROVN OF 11 KV INDEPENDENT FEEDER FROM 33 KV MRS TO 25 AMN COY AT JASAI MIL STN UNDER GE (A) BARMER
2024_MES_637796_1
84146/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BARMER
AS PER NIT
8 documents required · 8 mandatory
₹500
GE ARMY BARMER
₹88,000
Yes
13 Mar 2024
16 Jan 2024
14 Feb 2024
16 Jan 2024
12 Feb 2024
30 Jan 2024
16 Jan 2024 - 23 Jan 2024
Amount
Supply, insert, test and commissioning HT 11 KV, 3 phase, 50 Hz totally enclosed metal clad switch gear complete with Air Insulated Vacuum Circuit Breaker for add-on/extension which is having rupturing capacity 350 MVA, overload and earth fault protection, Digital type ammeter & voltmeter and of rating upto 630 Amps including all safety devices with inter locking system suitable for existing VCBs complete all as specified and directed by Engineer-in-Charge. Note :- (i) During insertion of new VCB with existing VCBs, any material or fabrication work require for resetting all Equipments will be done by the contractor on quoted rate for this item and no extra cost will be given to this effect. Make :- Make as per suitable for existing VCBs at site as approved by GE.
Supply, laying & testing HT UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sqmm x 3 core and complete all as specified and directed by Engineer-in-Charge.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches for laying of electric cables, errection of electric poles etc not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. not exceeding 10 sq m on plan and getting out in soft/loose soil etc complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches for laying of electric cables, errection of electric poles etc not exceeding 1.5m wide and exceeding 1.5m in depth for foundation etc. not exceeding 10 sq m on plan and getting out in soft/loose soil etc complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers each not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil not exceeding 50 metre & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
Supply and spreading clean, dry, fine river sand as sand cushion for UG electric cable laid in two layers (8 cm thick before laying of cable and 15 cm after laying of cable) total 23 cm thick including gently punning around cable complete all as specified and directed by Engineer-in-Charge. Note :- Punned thickness shall be measured for payment
Supply and laying reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx 180mm x 40mm complete all as specified and directed by Engineer-in-Charge.
Supply and fixing GI pipe, light grad galvanised, 80mm bore with all fitting laid in trenches/floor or fixed on electric pole/wall for mechanical protection of electric cables complete all as specified and directed by Engineer-in-Charge.
M & L for trenchless boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed by Engineer-in-Charge.
Dismandling of ACSR conductor, any size any type and deposited to MES store yard complete all as specified and directed by Engineer-in-Charge.
Dismandling of insulators from 11 mtr PCC pole, any size any type and deposited to MES store yard complete all as specified and directed by Engineer-in-Charge.
Dismandling of cross arms with clamp, nut/bolts etc from 11 mtr PCC pole, any size any type and deposited to MES store yard complete all as specified and directed by Engineer-in-Charge.
Dismandling existing unsv/ broken 11 mtr PCC pole from site all as directed. Rate quoted is included for demoiltion of PCC concrete and removing debris from site complete all as specified and directed by Engineer-in-Charge.
Supply, erecting and fixing in true vertical position, Prestressed cement concrete pole 11.0 metres long, confirming to IS-1678 (latest) with minimum cross sectional area 152 mmx152mm at top and 152mmx260mm at bottom, class 9 complete all as specified and directed by Engineer-in-Charge. Note:- Excavation and earth work and concrete in foundation and pedestal shall be measured and paid for separately.
M & L, Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C-2 using 40mm grade stone aggregate foundation for pole stay assy etc including necessary formwork & finishing concrete surface even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. Note :- Volume of pole/strut shall be deducted for the purpose of payment.
M&L for PCC 1:2:4 type B-1 using 20mm grade stone aggregateas in coping of poles, pedestal etc including necessary formwork & finishing concrete surface even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
S&F insulator pin type porcelain , vitreous , white ,brown or green 150 mm height and 150 mm dia including one galvanised mild steel spindle , two galvanised washers and one galvanised iron nuts for conductor working pressure 11000 Volts grade complete all as specified and directed by Engineer-in-Charge
S&F insulator disc type porcelain , vitreous , white ,brown or green 145 mm height and 255 mm dia ball and socket type , single disc assembly for tension with tension clamp for conductor working pressure 11000 Volts grade complete all as specified and directed by Engineer-in-Charge.
M & L for Stay assembly complete with accessories such as mild steel galvanised flat iron stay clamp, 7/4 mild steel galvanised stay wire, mild steel galvanised stay bow, thimbles including loop type insulator, 20mm mild steel galvanised stay rod and mild steel galvanised stay-plate all as shown in electrical plate No. 1 of SSR Part-1 complete all as specified and directed by Engineer-in-Charge. Note :- Excavation, earth work, cement concrete shall be measured and paid seperately under relevant items.
M & L for Aluminium conductor, steel reinforced (ACSR) of any size as approved on HT/LT poles including stringing, binding on insulators with copper binding wire etc, providing PVC sleeves for jumpers as in OH conductors complete all as specified and directed by Engineer-in-Charge.
M & L for galvanised steel contineous earth wire 4mm dia complete all as specified and directed by Engineer-in-Charge.
M & L for Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia complete all as specified and directed by Engineer-in-Charge.
M & L for Triple pole, mechanically operated, mounted on insulator (09 insulators) and steel frame, with operating spring loaded mechanism worked from ground level, for current rating upto 200 amps, 11000 volts working grade complete all as specified and directed by Engineer-in-Charge.
M & L for lightning arresters expulsion type complete with all fittings, 11000 Volts, transmission class, discharge capacity 65 kilo amp complete all as specified and directed by Engineer-in-Charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 with PCC earth chamber & cover, GI funnel with mesh connected to earthing test point all as specified or indicated including testing on complete all as specified and directed by Engineer-in-Charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 with PCC earth chamber & cover, GI funnel with mesh connected to earthing test point all as specified or indicated including testing on complete all as specified and directed by Engineer-in-Charge.
Supply and fixing cable route indicator, CI of standard size as per relevant IS specifications with voltage and size of cable indicated duly fixed on MS angle of size 40 x40x5mm and 500mm long embedded in PCC block (1:3:6) type C-2 using 40mm graded stone aggregate of size 30cm x 30cm x 20cm including painting and earth work complete all as specified and directed by Engineer-in-Charge.
SHREE KARNI LIGHT HOUSE
M/s Malinath Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .