Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹10.8 L+₹42,107.75 (4.06%)Rejected-AOC | L2 | Rejected-AOC Being Not L1 | |
| 3 | L3₹13.8 L+₹3.4 L (32.7%)Rejected-AOC | L3 | Rejected-AOC Being Not L1 | |
| 4 | L4₹14.3 L+₹3.9 L (37.8%)Rejected-AOC | L4 | Rejected-AOC Being Not L1 |
Tender Value
₹11.5 L
EMD Value
₹23,000
Closing Date
20 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Amritsar
HQ CWE Amritsar
SPL REPAIR TO BLDG NO P-45 COOK HOUSE AT OLD AMRITSAR CANTT
2025_MES_704929_1
83020/E8
Open Tender
Civil Works
Item Rate
120 days
GE Amritsar
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Amritsar
₹23,000
Yes
4 Jul 2025
22 Apr 2025
27 May 2025
22 Apr 2025
20 May 2025
6 May 2025
Amount
Demolition of cement Concrete(un-reinforced) in ground floors and paving n.exc 15cm thickness below or above ground level complete all as specified and directed.
Material and Labour for 75mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate ) as in floor complete all as specified and directed.
Material and Labour for 75mm thick Cement concrete type C-2, 1:3:6 (40mm graded aggregate ) as in plinth protection/floor complete all as specified and directed.
Material and labour machine pressed coloured chequered cement concrete tile of size 20cm x20cmx25mm thick over and including 15mm thick cement screed in CM 1:6 set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match the colour of tiles complete all as specified and directed.
Dismantling of brick work built in cement mortar, including all quoins, arches, pillars etc complete all as specified and directed.
Material and Labour for brick work with sub-class 'B' bricks straight or curved on plan exceeding 6 metres mean radius built in cement mortar 1:6 complete all as specified and directed.
All as per Srl item No 6 above but except bricks (old dismantled serviceable bricks obtained from Srl item No 5 shall be reused after necessary cleaning of mortar).
Material and labour for Brick work with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster on brick, concrete or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. Of any description complete all as specified and directed.
Material and Labour for rendering 15 mm thick on brick work or concrete surfaces on walls in CM 1:4 finishing even and smooth without using extra cement complete all as specified and directed.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed.
Material and Labour for Granite (of any type) work (table rubbed and polished) 20mm thick in steps , jambs, pillars, window cills, cooking plateforms and like in cemnet mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick rendering in CM 1:4 complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Supplying and Fixing glazed ceramic coloured tiles 450x300mmx6mm thick, etc. on vertical surfaces such as skirting , dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match over and including 10mm thick rendering plaster in CM 1:3 on brick surface complete all as specified and directed.
Supplying and Fixing non skid ceramic light coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
Supplying and Fixing in repair 15mm bore angle cock cast copper alloy of CP screwed down high pressure with crutch or butterfly handle complete all as specified and directed.
Supplying and Fixing PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
Supplying and Fixing in repair of brass cromium brass plated fancy type bib taps 15 mm bore long nose screwed down screwed for iron pipe or for brass complete all as specified and directed
Supplying and Fixing powder coated aluminium frame for doors ,windows, ventilators with one or more rebates including joining cleats for fixing complete all as specified and directed.( Min. thickness of powder coating 50 micron)
Supplying and Fixing Powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. (Min. thickness of powder coating 50 micron)
Supplying and Fixing powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. (minimum thickness of powder coating 50 micron).
Supplying and Fixing Sheet glass, 5.5mm thick ordinary quality, in squares,exceeding 0.50 sqm in each pane including rubber packing and aluminium beading with and incl solar control film 25 Micron reflective type sticked to glass panes as per instructions of manufacturer complete all as specified and directed
Supplying and Fixing Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed
Supplying and Fixing for Floor door stopper of aluminium alloy body and tongue, anodised,with hard drawn steel spring, fixed in floor with door shutter over lenth of cover plate150mm complete all as specified and directed.
Supplying and Fixing Brass Mortice loc 4 levers, vertical type, size 100 mm complete all as specified and directed.
Supplying and Fixing in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement including SS Grating complete all as specified and directed.
Material and Labour for applying two coats of whitewash on ceiling including preperation of newly plastered/old decorated surfaces complete all as specified and directed.
Taking down chowkat or frames with shutters (without taking off shutters from frames) not exc 1.5 Sqm each complete all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from frames) exc 1.5 Sqm and n.exc 4 Sqm complete all as specified and directed.
Supplying and Fixing in repair PVC (SWR) pipes single110mm socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
Supplying and Fixing in repair 110mm PVC (SWR) bends any radius complete all as specified and directed.
Supplying and Fixing in repair 75mm PVC floor trap with grating complete all as specified and directed.
Material and labour preparation of newly plastered surface of wall and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification in two or more coats on new work over 2mm thick wall care putty complete all as specified and directed.
Supplying and Fixing 15mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete including taking down complete all as specified and directed.
Supplying and Fixing 20mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete including taking down complete all as specified and directed.
Material and Labour for providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges type B1 (1:2:4) (20mm graded aggregate) complete all as specified and directed.
Material and Labour for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed.
Material and Labour for rendering 5mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 and finished the surfaces even and fair without using extra cement complete all as specified and directed.
Material and Labour for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in surface channels and drains complete all as specified and as directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitrred/stopped ends etc complete all as specified and directed.
Add or deduct for each 25mm girth or part thereof over or under 30cm.
Demolition of cement Concrete(re-inforced) in ground floors and paving n.exc 15cm thickness below or above ground level (reinforcement cut tas required to facilitate demolition) complete all as specified and directed.
Material and Labour for Reinforced Cement Concretetype type B1, 1:2:4 (20mm graded aggregate) (Nominal mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick rough finished surface of concrete flat complete all as specified and directed.
Material and Labour for Preparing new plastered wall surafces of any description and applying three coats of whited wash complete all as specified and directed.
Material and Labour for preparation of newly plastered wall surfaces and applying two coats of cement based paint complete all as specified and directed.
Material and Labour for preparation of new or previously un-treated steel surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over one coatd of red oxide zinc chrome primer complete all as specified and directed.
Dismantling Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Supplying and Fixing Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Supplying and Fixing Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Supplying and Fixing Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
Material and Labour for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia or securing with clips,complete all as specified and directed.
Hacking out old broken glass from wooden/ steel window cleaning the surface and removing from the site, thenafter Supplying and Fixing clear glass, 3mm thick ordinary quality, in any shape, not exceeding 0.50 sqm in each pane including and glazing with oil putty/wooden beading complete all as specified and directed.
Material and Labour for apply One coat of synthetic enamel paint on steel surfaces of any description over 10 cm in width or girth not otherwise described including prepration of old surfaces complete all as specified and directed
Dismantling wall and ceiling board (fibre, pulp, insulation etc), or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and directed.
Supplying and Fixing Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to at 457 mm centre including GI Hanger 6mm dia (Upto 1200mm length) adjusting level fixed to roof slab by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
Material and Labour for Seamless calcium silicate ceiling 12mm thick made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seamless finish complete all as specified and directed.(Frame work for ceiling shall be measured and paid separately)
Material and labour preparation of newly plastered ceilings and distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification in two or more coats on new work over 2mm thick wall care putty complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc.complete all as specified and as directed
Material and Labour for point wiring complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid PVC conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly complete all as specified and as directed NOTE: (i) Modular metal flush boxes concealed in wall with suitable cover plate for mounting switch, sockets, regulator etc. and cost of cutting chases & making good as existing to disturbed surface with cement mortar, if required any shall be deemed to included in the quoted rates. (ii) Modular fittings/fixtures such as switch, socket, regulator, etc., shall be measured and paid separately as under relevant item.
(a) One light point controlled by one switch
(b) One Fan point controlled by one switch & regulator
All as per ser item No. 61 here in above but point wiring with 2.5 Sqmm FRLS cable and 2.5 sqmm cable earth continuity wire for one 5 Amps outlet point on same board with other switches/sockets
All as per ser item No. 61 here in above but point wiring with 2.5 Sqmm FRLS cable and 2.5 sqmm cable earth continuity wire for one 3 pin 5 Amps socket outlet on independent board.
All as per ser item No. 61 here in above but point wiring with 4.0 Sqmm FRLS cable and 4.0 sqmm cable earth continuity wire for one 3 pin socket outlet,15 Amps on independent board.
Supplying and Fixing modular switch 1 way 6A, 240 volts, 1 module complete all as specified and directed
Supplying and Fixing modular switch 1 way 16A, 240 volts, 1 module complete all as specified and directed
Supplying and Fixing modular socket, 6A, 240 volts, 2/3 pin combined 2 module, flush type all as specified and directed
Supplying and Fixing modular socket, 6A/16A, 240 volts, 2/3 pin combined 2 module flush type all as specified and directed
Supplying and Fixing ceiling rose surface PVC/Polycarbonate, isolated body with face Bakelite 65x50 mm three terminal complete all as specified and as directed
Supplying and Fixing modular fan step regulator, 2 module, 240 Volts, 50 Hz, suitable for ceiling fan 1200 mm sweep complete all as specified and as directed
Supplying and Fixing LED lights fitting 1x 20W, 220V, AC, 5700K, decorative box type with driver, double sided connection, CRI> 80, PF>95%, THD<10%, Lumen>2100 lm including LED tube light of make: Havells or equivalent in Philips/Crompton, connecting up with 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose complete all as specified and directed.
Supplying and Fixing LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type, with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases (1.0 mm² size/core) complete all as specified and directed.
Supplying and Fixing Dusk & dawn roadway luminaries 35 Watt, 230 V AC, 5700K outdoor type with epoxy black powder coated sheet of make: Havells or equivalent make of Philips/Crompton, high pressure die-cast aluminum hosing and heat resistant complete with impact and corrosion resistant including thermal management in multiple optics, PF>95%, THD<10%, Lumen>4500 lm with IP 65/66 protection complete incl connecting wire with flexible PVC insulated copper cables from ceiling rose to fitting including driver, lamp bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length not exceeding 1.5 mtr, through mild steel clamp of 25mm width and four Nos. nuts, bolts & washers of 12mm dia, 100mm long fixed to wall with all other fittings complete and testing all as specified and directed.
Taking down carefully existing serviceable Ceiling fan, ceiling cable end, etc., removing the fan for keeping in safe custody, hanging the ceiling fan with down rod after rewiring including clamps, hooks, holdfasteners etc and connecting up, including making electric connection from ceiling rose to fan complete all as specified and as directed
Taking down carefully existing serviceable exhaust fan, ceiling cable end, etc., removing the fan for keeping in safe custody, fixing the exhaust fan after rewiring and connecting up, including making electric connection from ceiling rose to fan complete all as specified and as directed
Taking down carefully existing serviceable Geysers of capacity 25 ltrs, ceiling cable end, etc., removing the geyser for keeping in safe custody and refixing geyser with provn of new suitable MS bolts, PVC steel braided inlet/outlet connection pipe 15mm dia, 450mm long with two numbers brass union, NRV, grouted to wall and connecting up including provn of new 3 core sheathed multi-stranded flexible copper conductor cable, writing MES No. including making good to the disturbed surface including cleaning of element, flanges, tank etc. and testing complete all as specified and as directed
Material and Labour for distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, SPN 12 way, 240 volts grade with 200 Amps insulated rated bus bar with nickel plated brass, isolated neutral bar and door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, flush to wall, including testing suitable for fixing MCB SPN, SP etc, complete all as specified and as directed NOTE: (i) MCB DB & MCBs should be of same make as mentioned above. (ii) Necessary blank plates if required any to cover the blank MCB's place in DB and the rate shall be deemed to included in the quoted rates.
Supplying and Fixing MCB of SP 5 to 32 Amps current carrying capacity, 240V, 10KA 'C' curve, ISI marked, fixed in the MCB DB complete conforming to IS/IEC-60898-1 2002 with connection testing and commissioning including taking down old unsv one from the site complete all as specified and as directed
Supplying and Fixing MCB of MCB SPN 32 Amps current carrying capacity, 240V, 10KA 'C' curve, ISI marked, fixed in the MCB DB complete conforming to IS/IEC-60898-1 2002 with connection testing and commissioning including taking down old unsv one from the site complete all as specified and as directed.
Supplying and Fixing sub main wiring with 2 runs of 6.0 sqmm single core, multi-stranded PVC insulated, FRLS unsheathed cable 1100 Volts grade with copper conductor drawn through and including concealed non metalic PVC conduit, medium grade, ISI marked, suitable size with conduit fittings and accessories concealed in wall/ceiling/floor including 1 run of 6.0 Sqmm multistranded PVC insulated FRLS, copper conductor cable as earth continuity conductor and connecting to common earth dolly incl taking down old unsv one from site complete all as specified and as directed NOTE: Two runs of 6.0 sqmm copper cable and one run of 6.0 sqmm copper cable alongwith non metallic PVC conduit/conduit accessories will be measured as one unit length
Material and Labour for loadline distribution board, vertical, made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, VTPN 4 way, 415 volts grade with insulated rated bus bar assembly with isolated neutral bar,door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing suitable for fixing MCCB, MCB TPN/TP/SPN/SP etc, complete incl taking down old unsv one from site complete all as specified and as directed
Supplying and Fixing MCCB triple pole and neutral (four pole) 160 Amps, 415 volts, 50 Hz, having thermal setting range 70% to 100% and adjustable magnetic setting and breaking capacity 25 KA including making incoming and outgoing connections complete incl taking down old unsv one from site complete all as specified and as directed
Material and Labour for Earthing complete in replacement with galvanised iron mild steel earth plate electrode 60 cm x 60 cm x 6.3mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth of not less than 1.5 m below normal ground level, connected to glavanised earth lead of GI wire of size 4mm dia by means of GI Bolts, Nuts, check nuts & washers and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 25mm dia from earth plate to Panel/DBs and water pipe 20mm dia GI medium grade from top of the earth electrode raised upto a level of 50cm above ground level, MS funnel with wire mesh embeded in earthing pit of size 30x30x30cm in PCC (1:3:6) type C-1 incl exposed surfaces smoth finished with 15mm thick cement mortar (1:6), RCC pre-cast (1:2:4 type B-1) cover slab of 40mm thick with 2 Nos. MS handles of 12mm dia suitable for carrying of pit cover, Angle iron frame made out of 40x40x4mm angle iron for 30x30mm PCC pit for holding the pit cover including providing charcoal or coke and salt in alternative layers of 15 cm including necessary earth work in soft/loose soil, returning, refilling and removing of surplus soil to a distance n. exc. 50 mtr testing complete all as shown in electrical plate No-3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed.NOTE: (a) Cost of excavation, earth work, watering pipe, test point, MS Funnel with wire mesh and PCC pit with cover will be deemed to be included in the quoted rate. No extra cost shall be paid to the contractor against these items. (b) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor & no extra cost will be given to the contractor.
Supplying and Laying in trenches/drawn through pipes or in road crossings/paths/drains/ ducts/floors/along poles/equipments etc., of LT cable under ground, heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of 35 Sqmm 3½ core cross sectional areas including connecting up using suitable size aluminium lugs testing and commissioning complete all as specified and directed. NOTE: Excavation, earthwork, cable protection pipe shall be measured and paid separately
Supplying and laying double wall corrugated (DWC) high density poly ethylene (HDPE) of size 40mm dia including all necessary fittings, PN-4 rating, pressure 6 Kgf/cm², conforming to IS-16205 (Part-24) with high ring stiffness & cursh resistance capacity, etc., laid in trench for protection of submersible flat cable complete all as directed.
Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in soft/loose soil and in road cutting all as specified and as directed
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and as directed
Removing excavated material/surplus soil not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above starting point complete all as specified and as directed
Supplying and Fixing Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed
ESS KAY BUILDER (BID ID -3300830)
M/S Vinod Kumar (BID ID -3296084)
BHARAT ENGINEERS (BID ID -3296103)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .