| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC | L1 | Accepted-AOC work awarded on the basis of lowest rate quoted by the firm | |
| 2 | L2₹3.9 L+₹59,298 (18.0%)Rejected-AOC | L2 | Rejected-AOC work not awarded |
Tender Value
₹4.4 L
EMD Value
₹9,000
Closing Date
19 Dec 2022, 3:00 pmClosed
Director CSIR-AMPRI,Bhopal
Near Habibganj Naka Hoshangabad Road Bhopal
Civil and Electrical work
2022_CSIR_137958_1
1(503)2022 Works
Open Tender
Civil Works
Item Rate
60 days
CSIR-AMPRI
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Director CSIR- AMPRI
₹9,000
Yes
5 Nov 2024
12 Dec 2022
20 Dec 2022
12 Dec 2022
19 Dec 2022
13 Dec 2022
Amount
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand incuding manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) upto 20%
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand incuding manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20%: 3 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) upto 20%)
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. ----12.42.1 Coupler-----12.42.1.2 110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee with door 110x110x110 mm
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Brick work with chimny brick of RAVI/KAVI/ SHREE/A D in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and applying multicoat synthetic plaster as per approved design, pattern texture in 2 mm thick on new plastered surface finished in proper line and level as directed by Engineer-in-charge in five coats consisting of composition of four order of application given as under includig all materials, labour and scaffoldings etc. 1) Scrapping of the new surface and applying sealer primer mixed with water in the ratio 1:3 (part sealer primer : 3 part water) and applying by brush @ 0.25 kg/sqm. 2) Applying levelling coat of spectrum rustic fine or equivalent with trwel as a putty finished to generate required texture by trowel. 3) Applying third coat of synthetic plaster with trwel @ 2.5 kg/sqm finished to generate required texture by trwel. 4) Applying two coats of exterior super fine pigmented acrylic wall coating as top coat @ 0.5 kg/sqm in two coats and colours as approved by Engineer-in-charge all up to a height of 10m.
Demolishing & shifting of MS sheet chajja with MS sq pipe frame including all fixture and fittings etc complete
Labour for shifting of machines,jungle clearance, junk clearance,septic tank & reconnection of tank etc
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box/celling rose and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group 'C'.
Wiring for circuit / submain wiring alongwith earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required
2 X 1.5 Sq.mm + 1 X 1.5 Sq.mm earth wire.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (Make - BEC/Kissan/Kasta/ Supreme/ Sudhakar/ Reliance)
Supplyiong and Fixing following size/ Modular plate, GI box alongwith modular base & cover plate for modular switchesin recess ets as required
1/2 module
6 module
8 module
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way Double Door
SSC ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .