Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹16.5 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹22.3 L+₹4.1 L (22.8%)Rejected-AOC 34 1 12 2F SAINIK VIHAR DEORI ROAD AGRA UP 282007 | AGRA | UTTAR PRADESH | 282007 | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹24.9 L+₹6.7 L (37.3%)Rejected-AOC 32 H I G AWAS VIKAS COLONY SECTOR 3 BODLA AGRA UP 282007 | AGRA | AGRA | UP | 282007 | L-3 | Rejected-AOC L-3 | |
| 4 | L-4₹24.9 L+₹6.8 L (37.4%)Rejected-AOC | L-4 | Rejected-AOC L-4 | |
| 5 | L-5₹28.8 L+₹10.7 L (59.1%)Rejected-AOC 64 250 2 COD ROAD HASTINAPURI MADHU NAGAR AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L-5 | Rejected-AOC L-5 |
Tender Value
Refer Docs
EMD Value
₹64,500
Closing Date
26 Feb 2022, 6:00 pmClosed
GE I RND Delhi
MILITARY ENGINEER SERVICE, GARRISON ENGINEER I RND, LUCKNOW ROAD, TIMARPUR DELHI-110054
REPAIR TO FENCING, COMPOUND WALL, SEPTIC TANKS, SOAK WELL, SEWAGE LINE AND REPAIR / REPLACEMENT OF CERTAIN E/M FITTINGS / FIXTURES AT RESIDENTIAL N TECHNICAL AREA AT ADRDE AGRA UNDER GE (I) RND DELHI
2021_MES_495377_1
GE/RnD-86/AGR/2021-2022
Open Tender
Civil Works
Item Rate
270 days
Delhi
Class D, Cat a(i), b(i)
2 documents required · 2 mandatory
₹500
GE I RND Delhi
₹64,500
Yes
1 Apr 2022
16 Dec 2021
28 Feb 2022
16 Dec 2021
26 Feb 2022
14 Feb 2022
Amount
Cleaning of sewage pipe line of any dia and depth by rodding and water pressure and cleaning of sewage line from manhole to manhole complete by mechanical means or manually complete all as specified and directed.
Cleaning of manhole upto 1.5 M deep and taking out sludge, night soil, mud, silt and other foreign material to any form by any means and removing the same outside MoD land to a distance exc. 10 KM away and buried under ground complete all as specified and directed.
Cleaning desilting and emptying of existing septic tanks by mechanical means including taking out sludge and other foreign materials and removing the same outside MoD land to distance exc 10 KM away and buried under ground complete all as specified and directed.
Dewatering of sludge water from septic tank, soak wells, manholes etc including loose liquid meet ash grease, and fiber & vegetations etc by means of mechanically power transport under foul conditions and removal of sludge/debris exc 500m & n.exc 1 KM and buried under ground complete all as specified and directed
Cleaning of blocked trap in kitchen/bathroom/WHB/sink/ Urinal etc by rodding or manually effected upto 1st manhole including kept work site clean and tidy complete all as specified and directed. Note for ser item No. 1.00 to 5.00 (i) Rate also includes for necessary tools and plants which is required to carryout the cleaning works ie. Cleaning rod, bucket, bamboo sticks, kasha etc. (ii) One supervisor shall take complaint from complaint cell/JE concerned & deploy required safaiwala to execute the work on daily basis. (iii) Complaint shall be completed on same day. In case the complaint is not completed on the same day, a penalty of Rs, 200/- per complaint shall be recovered from the payment of contractor. (iv) Necessary complaint register and printed machine numbered complaint slip as per specimen given by the Engineer-in-Charge shall also be provided by the contractor. (v) After completion of complaint, complaint slip shall be signed by the user and re-submitted to the concerned JE/Engineer-in-Charge. (vi) Sewage safety norms shall be strictly followed. (vii) Sludge shall be removed from site in covered vehicles only.
Excavation in trenches n.exc 1.50m wide and n.exc 1.5 M depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc nexc. 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including, leveling, watering and well ramming in soft/loose soil in layers n.exc 25cm thick each complete all as specified and directed.
Removing excavated material/soil to a distance n.exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed.
M&L for plain cement concrete 1:4:8 type D-2 (using 40mmm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) cast in situ as in coping/benching including necessary form work complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in surface channels & drains complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred stopped ends etc complete all as specified and directed
Demolition of cement concrete (reinforced cut as required to facilitate to demolition) of any description and in any position not otherwise described complete all as specified and directed.
M&L for precast reinforced cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in cover slab for manholes septic tanks etc including necessary form work and set in CM 1:6 complete all as specified and directed. Note: Reinforcement shall be measured and paid separately.
M&L for providing 10mm dia TMT bar and over cut to length, bent to shape required, including cranking, bending and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
All as per ser item No. 15.00 above but 8mm dia as in stirrups and spacers/binder or in slab/covers.
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) bed to drain pipe 150mm dia including packing under and haunching against the pipe after they are laid including necessary formwork complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2, (using 40mm graded stone aggregate) as in bed to drain pipe 100mm dia including packing under and haunching against the pipe after they are laid including necessary formwork complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar for 100mm dia pipe complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar for 150mm dia pipe complete all as specified and directed.
M&L for salt glazed stoneware drain pipes 100mm dia (internal) grade ‘A’ laid in trenches and jointed in cement mortar complete all as specified and directed.
M&L for salt glazed stoneware drain pipes 150mm dia (internal) grade ‘A’ laid in trenches and jointed in cement mortar complete all as specified and directed.
M&L for cutting in to existing manholes for connecting new drains pipe internal dia 100mm and making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ sec) in cement concrete 1:2:4 type B-1, smooth finished, and reforming benching as required complete all as specified and directed.
M&L for cutting in to existing manholes for connecting new drains pipe internal dia 150mm and making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ sec) in cement concrete 1:2:4 type B-1, smooth finished, and reforming benching as required complete all as specified and directed.
Dismantling AC/PVC 110mm bore rain water pipe (any size pattern) including all fittings complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joint fixed to wall complete all as specified and directed.
S&F PVC (SWR) single ‘T’ equal or unequal 110mm bore complete all as specified and directed.
S&F PVC (SWR) bends any radius, 110mm dia complete all as specified and directed.
S&F PVC (SWR) vent cowl any radius, 110mm dia complete all as specified and directed.
S&F PVC (SWR) floor trap of dia 75mm with grating, including solvent cement and fixed in position complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar including all quoin, arches, pillars etc complete all as specified and directed.
M&L for brickwork with subclass ‘B’ old size bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Taking down cement or cement lime plaster of any description/layer on brick or stone wall including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick/stone or concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparing of new plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
S&F in repair switch piano flush type, 5 Amps, single pole one way connecting to existing switch board, inculding replacing the old unserviciable/ damaged piano switch complete all as specified and as directed
S&F in repair Buzzer, Ding Dong AC. 230 volts,single pole, inculding repalcing the old unserviciable/ damaged bell and making connection to existing serviciable point complete all as specified and directed.
S&F in repair bell push , 5/6 Amps, single pole, inculding repalcing old unserviciable/ damaged bell push making connection to the existing serviciable point complete all as specified and directed.
S&F stepped type electronic fan regulator 60/100 watt flush type fixing on the existing laminated sheet of switch board complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin ,5 Amp flush type , having 04 Nos of screw hole suitable for fixing on existing switch board complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin 5 and 15 Amp flush type universal having 04 Nos of screw hole suitable for fixing on existing switch board, complete all as specified and directed.
S&F in repair switch socket combination 6 Amp, 2 in 1 with PVC box, 4 fixing holes,240 V, 50 Hz,surface mounting suitable for fixing to existing light point complete all as specified and directed.
S&F in repair switch socket combination 6 Amp, 2 in1 with PVC box and 16 Amp socket, with 4 fixing holes,240 V, 50 Hz,surface mounting suitable for fixing to existing light point complete all as specified and directed.
S&F in repair LED lamp 20 Watt, suitable for fixIing to existing lamp holder complete all as specified and directed.
S&F in repair Fan Capacitor 2.5 MFD suitable for ceiling fan 1200 mm/ 1400 mm sweep and connecting with connecting clip of existing ceiling fan complete all as specified and directed.
S & F in repairs decorative ultra slim square profile LED light fitting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack 20 watt, 6000 K, and making connection to existing light point complete all as specified and directed.
S & F in repairs crystal glass 20W LED tube with double side connection,with high efficiency suitable for fixing in existing FTL batten, complete all as specified and directed.
S&F in repair trim LED round, aesthetically designed recessed mounted panel in a light weight plastic body light fitting 15 Watt 3000 K , connecting to existing light point, complete all as specified and directed.
S&F in repair E-LITE LED 9 Watt, 6000K, decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly energy efficient ready to use .Complete all as specified and directed.
Supply and fix in repair heating element 1500 watts capacity in round/ triangular shape bottom(Cup shape ) with rubber gasket and fixing to existing geyser complete all as specified and directed.
Supply and fix in replacement thermostat suitable for adjusting the temperature from 0 degree centigrade to 80 degree centigrade for geyser complete all as specified and directed.
Supply and fix in repair brass geyser assembly suitable for 25 Ltr capacity gyser including nuts, washers, check nuts and all connected items, complete all as specified and directed.
Supply and fix in repair copper inner tank suitable for geyser of capacity 25 ltr with 6/9 numbers of holes all as specified and directed.
Supply and charging (top up) compressor of existing water cooler and AC any type and capacity charging with required quantity of appropriate Refrigerant Gas R 22 complete all as specified and as directed.
M&L in replacement of old unserviceable water pumping kit of desert cooler (ISI marked) single phase, 220 AC, 20 Watt suitable for desert cooler complete all as specified and as directed.
M&L in replacement of copper wound desert cooler motor 170 watt, 1350 RPM, 220 Volts single phase as per exiting sample/ size and fixing in same position by providing new nut , bolts,washer,MS frame/side arms and rubber pads etc including testing complete all as specified and as directed .
S&F in replacement of desert cooler body size 30"x30"x35" made of PGI sheet 1 mm thick complete with both side panels,front panel,side arms,tank,frontgrill made of PGI sheet etc including fixing the existing fan kit & Pump motor received from old unserviceable desert cooler including all electrical connections,testing and commisioning complete all as specified and as directed.
S&F in replacement of PVC flexible pipe of 15 mm dia suitable for desert cooler water circulation system, including tees, bend etc clamping strip complete all as specified and as directed.
M&L for removing the desert cooler from the site and re-fixing after cleaning the desert cooler body from inside and outside using sand paper to make the smooth surface and painting one coat of synthetic enamel paint over a coat of red oxide primer as per exiting complete all as specified and as directed.
Taking down ceilling fan/exhaust/air circulating fan of any size or make by disconnecting electric connection and removing from site for rewinding,servicing, painting of fans and refixing in the same position or as directed by Engineer-in-Charge complete all as specified and as directed.
M&L for rewinding of ceiling fan 1400mm sweep with super enamelled copper winding wire of existing size with insulation material complete all as specified and directed.
All as per ser item No.61 above but 1200 mm sweep.
All as per ser item No.61 above but exhaust fans of size 300 mm sweep.
M&L for painting of ceilling fans of any make and size upto 1400 mm sweep at site with one coat of superior quality synthetic enamel spray paint of approved make by spraying, filling cavities with filler after preparation of surface and writing letter as per existing such as (MES 12345) with black synthetic enamel paint 1" high on both sides of fans complete all as specified and directed.
S&F in repair MCB DBs TPN, double door flush mounted 4 way 415 V complete all as specified and as directed.
S&F in repair MCB DBs TPN, double door flush mounted 6 way 415 V complete all as specified and as directed.
S&F in repair MCB, SPN 40 Amps, 240 V AC complete all as specified and as directed.
S&F in repair MCB SP 6 to 32 Amps, 240 V, 50 Hz,10 kA Suitable for lighting and other domestic loads complete all as specified and as directed.
S&F in repair MCB TPN 63 Amps, 415 V, 50 Hz, Suitable for lighting and other domestic loads complete all as specified and as directed.
S&F in repair metal clade plug and socket board SPN encloser with 20 Amp SPN MCB suitable to replace the existing unserviciable plug socket, and fixing to existing point complete all as specified and as directed.
M&L for replacement of defective ball bearing for ceilling fan of 1200 mm sweep complete all as specified and as directed.
All as per ser item No. 71 above but for ceiling fan of size 1400 mm.
Syupply and fix in repair cover outer complete including top and bottom suitable for 25 Ltr capacity gyser of any make, shape and size as per existing but gauge of sheet not less than 22 SWG all as specified and directed.
Supply and fix in repair, PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep, complete all as specified and directed.
S & F in repair LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F in repair PVC insulated FR-LSH, multistranded, 1100 Volts, single core flexible copper conductor of size 1.5 sqmm including fixing as per existing point complete all as specified and directed.
S & F in repair PVC casing caping of size 20 x 12 mm,2.00 mtr long, fixing on wall as per existing including all fixing arrengement complete all as specified and directed.
M/S OM Enterprises
m/s shanti consruction co
M/s Salim Mohomad
Allied Builders
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .