| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.4 LAccepted-AOC | 1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | 2₹13.1 L+₹1.7 L (14.9%)Rejected-Finance 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹13.5 L+₹2.0 L (17.8%)Rejected-Finance | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹14.3 L+₹2.8 L (24.7%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹14.5 L+₹3.1 L (27.2%)Rejected-Finance | 5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
8 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJOR ANIMESH TRIPATHI
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
REPAIR MAINT TO E M INSTALLATIONS UNDER AGE B R I PATIALA
2022_MES_537107_1
GE(N)/PAT-40/2022-23
Open Tender
Civil Works
Item Rate
210 days
PATIALA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE NORTH PATIALA
₹40,000
Yes
1 Sept 2022
11 Jul 2022
10 Aug 2022
11 Jul 2022
8 Aug 2022
25 Jul 2022
Amount
Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for cement plastering 15mm thick in two layers (10mm and 5mm respectively) in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth with using extra cement complete all as specified and as directed by Engineer-in-Charge. Note : WPC will be measured and paid separately.
M&L for cement plastering 10 mm thick in cemet mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
M&L for cement plastering 5mm thick in cemet mortar 1:3 as on ceilings or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified & as directed by Engineer-in-Charge.
Complete removal of existing treatment of any type/description such as cement base paint, external emulsion etc from external surfaces of walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc with mechanical means/grinder complete all as specified and directed.
M & L for Applying two coats of oil bound distamper white or tinted over a coat of primer on walls incl one coat of primer over & incl preparation of plastered finished of wall specified and directed by Engineer-in-Charge.
M & L for Preparation old/new of plastered surfaces of walls and applying two coats of cement base paint over a coat of primer and preperation of plastered surface, complete all as specified and directed by Engineer-in-Charge.
Preparation of new plastered surfaces of ceiling and applying three coat of white wash on ceiling surfaces all as specified and directed.
Complete removal by brushing/machenical grinder and applying 02 coats of exterior emulsion paint @ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer incl all safety equipments, Ropes, safety belts and ladders (Scaffolding) as reqd upto hight of 29 Mtr for Overhead RCC Water Tank complete all as specified and directed.
M & L for preparing old painted steel and iron surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engr-in-Charge.
M & L for Repair to RCC sunshades, Chajjas, Balconies, Columns, bands, beams and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcher with cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including preparation of surfaces to receive finishes and two coat cement base paint, complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed.
S&F Powder coated Pressed steel frames made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified,size 105x60mm complete all as specified and directed.
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. (each line wire to be measured)
M/L providing RCC Type B1 1:2:4 (20 mm mm graded stone aggregate) as in pre cast fencing post struts etc average sectional area exc 100 Sqcm and not exceeding 250 Sqcm with or mitred Tops incl grouting in natural ground or cement concrete complete all as specified and as directed
S&F Vitreous china squatting pan of Orissa patten size 580 x 440 white with (C I P trap long size) joint run and lead front or back inlet with integral footrest including connection to trap and to flushing pipe,anti-syphonage pipe, etc, fixed in repair complete and making good to floor in CM 1:3 all as directed and specified.
Repairs to gates of any description and size including taking down and repairs to pintle hinges welding if required and bedding in brick or concrete work and check for its movement align the shutter by means of hammering / welding/oiling, lifting the shutter by means of pully or crane by taking safety measuers including replacement of pintle hinges.
M & L for Roughening surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed.
M & L for PCC 1:2:4, type B-0 using 12.5mm graded stone aggregates as in padding over roof, minimum thickness at khurra as 20mm to maintain a slope of 1:100 ,complete all as specified and directed.
M & L for Providing and laying 3mm thick APP (Atactic Polyproplene Polymer) modified prefabricated five layer, weight not less than 4.0 Kg/Sqm water proofing membrane black finished, reinforced with non-woven polyster matt make as approved including of a coat of bitumen primer @ 0.40 ltr/sq.m by the same membrane manufacturer of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70 - 160 cps Over the coat, 3mm th 5 layered APP membrane shall be laid using butane torch and sealling all joints, overlaps of joints shall be 75mm longitudianal and 100 mm on transverse direction etc after the surface complete as per standard practice as per manufacturers instructions. The vital physical and chemical parameters of the membrane shall be as under - (i) Joint strength inlongitueinal and transverse direction at 23 degree C as 650/450N/5cms (ii) Tear strength in longitudinal and transverse direction as 300 / 250 N/. Softening point of membrane not less than 150 degree C Cold flexibility upto 20 degree C when tested in accordance with ASTM (D05147) (iii) The laying of membrane shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed.
M&L for Aluminium painting 2 coats per Sqm over a coat of primer on APP surface by using roller/brush as per manufacturer, complete all as specified and directed.
M& L for Flush pointing in cement mortar 1:3, to bricks laid flat or brick tiles in pavings, aprons etc, complete all as specified and directed.
Supply only chicken wire mesh 22 gauge of size not less than 20X20mm all as specified & as directed by Engineer-in-Charge.
M & L for Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in plinth protection, 50 mm thick, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints complete all as directed by Engr-in-Charge and complete all as specified and directed.
Supply only sheet glass ordinary quality 4mm thick area n.exc 0.50 sqm each complete all as specified and directed.
M & L for Glazed ceramic tiles 200 x 300mm x 7mm thick coloured on vertical surfaces set and jointed in neat cement slurry and pointed in white cement to match including 10 mm thick rendering of CM 1:4 all as directed and specified.
M & L for Non skid ceramic (coloured tiles) of size 300 x 300 x7mm thick in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match scred 15 mm thick in cement mortar (1:4) complete all as specified and directed.
M&L Machine pressed rubber moulded ISI marked precast cement concrete interlocking paver block any shape and size and of colour 50% red coloured tiles and 50% grey coloured tiles confirming to IS-15658-2006 of 60mm thickness M-35 Grade and including filling of interstices with fine sand over including 25mm thick layer of sand chusion over 75mm thick PCC 1:4:8 type D-2 (40mm graded stone aggregate), complete all as specified and directed.
M & L for PCC with type B-0. 1:2:4 (12.5mm graded aggregate) 40 mm thick as in flooring and finishing the floor even and smooth without using extra cement complete all as specified and directed.
M&L 75mm thick PCC 1:4:8 type D2 for sub base complete all as specified and directed.
M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, with gray cement and no pigment set, jointed and pointed in neat cement slurry in floors incl 20mm thick screed bed in CM 1:6 complete all as specified and directed.
S&F 15mm bib tap fancy brass chromium plated butter fly handle, screwed down, screwed for iron pipe or for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S & F for PVC(HDPE) rain water pipes, 110 mm bore, single socketed in any length with rubber ring joints fixed to walls complete all as specified including fixing of pipe to wall with flat iron clamps of size 25 x 3mm, bolts washing, nuts etc including taking down existing damaged CI rain water pipe complete all as specified and as directed
Arneja Builders
RUPINDER SINGH SODHI
SWAMI ENGINEERS
AR CONSTRUCTIONS
Buttar Construction Co.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .