Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 and found in order | |
| 2 | L2₹28.8 L+₹6.9 L (31.3%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹30.4 L+₹8.4 L (38.4%)Rejected-AOC 180 SECTOR 1 CHANNI HIMMAT CHANNI HIMMAT JAMMU JAMMU JAMMU AND KASHMIR 180015 UDYAM JK 07 0006292 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-AOC Not being L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
13 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ 135 WE
HQ 135 WE C/O 56 APO
COMPREHENSIVE REPAIR/ MAINT OF 33/11 KV MRS AND CONNECTED ITEMS UNDER GE NORTH AKHNOOR
2022_MES_562853_1
CWE/JA-30/2022-23
Open Tender
Civil Works
Item Rate
180 days
AKHNOOR
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE NORTH
₹50,000
Yes
27 Jan 2023
12 Nov 2022
15 Dec 2022
12 Nov 2022
13 Dec 2022
29 Nov 2022
12 Nov 2022 - 18 Nov 2022
Amount
Taking down unsv PCC poles and M&L for steel tubular swaged pole type 410 SP-64 (12 metre long) with 300 mmx300mmx6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5M from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5M from ground level/coping, complete all as specified and directed.
Taking down unsv PCC poles and M&L for steel tubular swaged pole type 410 SP-55 (11 metre long) with 300 mmx300mmx6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5M from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5M from ground level/coping, complete all as specified and directed.
M&L for fixing in replacement of ACSR conductor Size 3 of 6/1 x4.72(dog) drawn straight horizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre to centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag, jointing jumpers, etc complete all as specified and directed by Engr-in-Charge.
Scraping of old paint from two pole structure without removing accessories and preparation of surfaces for repainting. Repainting the poles with one coat of alternative white and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint .Repainting the remaining Iron parts i.e. cross arms, supporting angles, XPM jali, clamps, GI bkt etc and steel pole above 1.5 mtr height by applying one coat of alumn paint or PCC pole with snowcem of approved color all as required at site or directed.
Material and labour for Rubber tiles 5mm thick with fabric backing or insert, plain coloured or marbled topping, matt or glossy, laid in floors with approved adhesive all as specified and directed.
Trimming and cutting of tree branches coming across 33KV overhead HT line clearing around line 1.5m single/both sides and disposal of branches to distance not exc 50m and complete site all as specified and directed Note:- 1. length of span 100 to 150mtr. 2. Due care is given while cutting /trimming tree branches that there should be no damage to existing conductor/poles. In case due to negligence,damaged is caused is to make good/renewal by the contractor from his own resources and nothing extra will be admissible.
Taking down old unsv 33 KV Isolator and M&L for rotating isolator triple pole double break capacity 33KV 630A 25 KA rotating type with earth switch gang operated outdoor having each pole has galvanised steel base, solid core or post type insulators,EC grade copper fix and moving contacts, GI coupling pipe of adequate length for rotating operation from ground level and operating handle for smooth operation, ferrous parts are hot dip galvanized and non ferrous parts are heavily tinned to withstand weather. The handle fabricated from channel, lever and turned pipe gripper with locking arrangement in both ON and OFF position all as specified and directed by Engr-in-charge.
Taking down unsv lightening arrestor and M&L for 33KV 10 KA surge type lightening arrestor for 33000V(-15% to +10%,3 phase,50HZ(-5% to +30%) power supply. The lightening arrestor shall be line type and gapless and of non-linear resistors made of Zinc oxide having counter meter and to sustain spark over voltage upto 100 KV, withstand standard impulse voltage of 115KV,maximum residual voltage at nominal discharge capacity current shall be 100KV all as specified and directed. Make ABB, Siemen,L&T,Electricfield
M&L for preparation of old painted surface of outer surface of steel structure of 33 KV Grid bus bay strucure at Grid,length 30 Rm, Height 3Rm,width 7.5Rm by brushing/cleaning stain,greasy spots with thinner, incl painting on two and four pole structures in the yard applying two coats of spray painting(synthetic enamel paint) all sides with spraying machine in the yard after disconnecting power supply including writting description of equipment in block english letter 100mm size with whie and black synthetic enamel paint as per details given by deppt all as specified and directed.
Taking down old unsv and Supply, installation, connecting electrically & commissioning switch air break, gang operated, tripple pole mounted on insulators 15 Nos and steel frame with operating mechanism in worked from ground level, drop out fuse, for current rating upto 200 amps and working voltage 11000 volts all as required at site or directed by Engr-in-charge.
M&L for sieving out graded coarse aggrgrate and and taking out sand dust/gravel of size less than 20mm of nominal size and Supply filling and laying coarse aggregrate normal size 25mm at 33 KV Grid bay/yard , deposted spread and levelled in layers not exc 100mm thick,rammed and watered to a true surface all as specified and directed.
M&L in replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint
Labour only for restringing of over head line ACSR of any size and upto 3 wires in a span with GI earth wire of 4 mm dia of span length 30 to 60 m to permissiable sag incl winding with Aluminium conductor and triming of branches of tree beside the span all as directed.
Suplying and fixing in replacement of Pin type, porcelin, vitreous, white, brown or green insulator, size 150mm height, 150mm dia for 11000 volts grade, including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, conforming to IS: 7321-1931, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as spd and as directed by Engineer-in-Charge.
Supply and fixing in replacement of polymer Disc insulator with hard ware fittings 33 KV grade standard size ISI marked all as specified and directed.
Taking down false ceiling incl snap grid of any type or any description all as directed.
Supply and fixing anodised aluminium snap grid frame work for false ceiling size of grid 605 x 605 mm with 12mm perforated particle board /tiles of size 600mmx600mm complete with GI Hangers adjusted level fixed to roofs slabs by means of ceiling cleats made out of GI flat and fasteners 12.5 mm dia , 40mm long complete all as specified.
Taking down old/unsv flood lights of any type and M&L for LED flood light of capacity 250 watt IP 66 Lumainire with aluminium die cast housing toughened glass and unique lens system for enhancement illumination complete with all accessories Make Wipro cat part No LF3 -342-060-57XX or equivalent in specification.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Taking down old/burnt supply, laying,jointing testing and connecting cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored electric power cable (heavy duty) of size 11KV(E) volts grade with stranded aluminium conductor ofsize 240 sqmmx3 core all as specified and directed by Engr-in-charge .
Taking down old/burnt and supply, laying,jointing testing and connecting cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored electric power cable (heavy duty) of size 11KV(E) volts grade with stranded aluminium conductor ofsize185 sqmmx3 core all as specified and directed by Engr-in-charge.
Taking down old/burnt and supply, laying,jointing testing and connecting cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored electric power cable (heavy duty) of size 11KV(E) volts grade with stranded aluminium conductor ofsize 95 sqmmx3 core all as specified and directed by Engr-in-charge.
Supply and fixing in replacement polymer post insulators with hardware fittings 33 KV graded all as specified and directed.
Supply and fixing in replacement PG aluminium cast alloy clamps suitable for existing ACSR conductors of type sheep/panther/Zebra with nuts and bolts all as specified and directed.
Supply and fixing in replacement T connector Clamp aluminium cast alloy clamps suitable for existing ACSR conductors of type sheep/panther/Zebra with nuts and bolts all as specified and directed.
Supply and fixing in replacement rigid type terminal connector ,stud to conductor/cable aluminium cast alloy clamps suitable for existing ACSR conductors of type sheep/ panther/ Zebra with nuts and bolts all as specified and directed.
M&L for centifuging and dehydration including filteration and cleaning of transformer oil of 33/11KV, 3.15MVA Transformer on site on load by dehydrattion machine including sample before and after dehydration and filteration oil all as specified and directed( contractor shall have to arrange dehydration machine and testing kit at his own resources all is specified and directed.
Supply and filling of top up of transformer oil in transformer of die-electric strength not less than 60 KV(AT 2.5MM gap) at high voltage of IS specification of low viscosity.(Note:- Transformer oil should be provided in sealed container) Make HP,BPL,Oil corporation of india
Supply and fixing in replacement metal heavy duty Exhaust fan 450 mm, Single phase complete with louvre all as specified and directed.
Cable end termination joint outdoor cold shrinkable type suitable for stranded aluminium conductor 3 core,11 KV XLPE of 185sqmmx3 core cross sectional area including testing and commissioning etc complete all as specified.
Supply and fixed cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 50 sqmm to 90 sqmm
Cable end termination joint indoor cold shrinkable type suitable for stranded aluminium conductor 3 core,11 KV XLPE of 185 sqmmx3 core cross sectional area including testing and commissioning etc complete all as specified.
Cable end termination joint indoor cold shrinkable type suitable for stranded aluminium conductor 3 core,11 KV XLPE of 240 sqmmx3 core cross sectional area including testing and commissioning etc complete all as specified.
M&L in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm.
M&L for 80 mm thickness M-40 Grade Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006, jointed and pointed with grey cement and no pigment including 50mm thick sand cushioning and PCC lock at edges, complete all as specified and directed.
Disconnecting all HT connection of VCB panel and Taking down exisitng unsv/ broken vaccum interupter and Supply and fixing vacuum interupter suitable for indoor VCB 11KV 800 Amp as per sample of Make CG all as specified and directed.
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as spd & directed.
Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement.
M& L for two coats of cement base paint over a coat of primer on newly plastered surface including preparation.
Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation of pole and laying of HT cable as in soft/loose soil and getting out complete all as specified and directed.
Returining filling in including spreading ,levelling,watering and wall ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed.
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point
Supply and laying sub class 'B' bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid.
Material and labour for sand cushioning in trenches including spreading and consolidation in layers of 8cm thick before laying the cable & 15 cm thick after laying the cable and punned down to form a bed complete all as specified and directed.
M & L for cement concrete type D-2 1:4:8 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete.
M & L for PCC 1:2:4 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide
Dismantling fencing wire mesh, any type
Dismantling posts or strut (wood, steel or RCC ) any section, including taking out embedded portion and making good disturbed ground.
Excavating in post holes (or similar holes) in soft/loose soil, each not exc .50 cum getting out returning filling in and ramming earth or broken rubble mixed with earth around , in layers not exc 25 cm and removing surplus soil to a distance n exc 50 m and making good surface.
M & L for mild steel bars TMT Fe 500D/550D 10mm dia & over cut to length bent to shape required including,crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, quality confirming to IS.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide.
S & F angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165.
M & L for reinforced cement concrete M-20 (nominal mix) type A-1 (using 20 mm graded aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs.
Supply and fixing MS galvanisd chain link fencing of mesh any size.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire
Two coat of synthetic enamel paint over a one coat of red oxide primer including preparation of new or previously untreated steel surface of any descprition with mordant solution including washing and cleaning etc. not ortherwise described over 10 cm width or girth, complete all as specified.
One coat of synthetic enamel paint on old steel surfaces including preparation of old painted surface not otherwise described over 10 cm width or girth complete all as specified and directed by Engr-in-Charge.
Material and labour for 11 KV pilfers resistant metering panel housed with 3 Nos dry type 11 KV CTs and 01 No three phase dry rtype PT copper wound outdoor type having PT 11KV/110V rated burdens 10 VA accuracy class 0.5 frquency 50 HZ three phase insulation class A IS:3156 and CT with trivectometer of L&T , Secure and suitable for 100/250/315 KVA transformer having primary current 10A/15A/20A and secondary current 5A having accuracy class 0.5 IS 2705 all as specified and directed.
Jiwan Singh
Tawi Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .