Executive Engineer
132 KV SUBSTATION BHARUA SUMERPUR
Work of REPARING OVERHAULING AND REPLACEMENT OF DEFECTIVE POLE AND VECUUM INTERUPTER WITH NEW ONE OF DEFECTIVE 33 KV VCB AT 132 KV S/S BHARUA SUMERPUR.
2023_UPTCL_766331_1
TS-56/ETD(H)/2022-23
Open Tender
Electrical Works
Lump-sum
30 days
132 KV S/S Bharua Sumerpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹295
Yes
Executive Engineer
₹2,000
Yes
31 Jan 2023
12 Jan 2023
28 Jan 2023
12 Jan 2023
27 Jan 2023
12 Jan 2023
Amount
Details of Work.
Repairing, overhauling and replacement of defective pole with new one, provided by department free of cost and vacuum interrupter with new one, provided by contractor at his own cost of following 33 KV VCB type circuit breaker at 132 KV S/S Bharua Sumerpur under ETD Hamirpu
(A) 33 KV VCB SIEMENS Make at 132 KV S/S Bharua Sumerpur (01 No.) By doing following work in each circuit breaker:- (i) Cleaning of porcelain of drive insulator and porcelain of vacuum interrupter of each pole. (ii) Checking & adjustement of snatch gap, travel of drive insulator rod & tie rod of each pole. (iii) Opening, repairing of mechanism by welding, drilling, machning and filling of material as per requirement and proper fitting of it in breaker cubicle. (iv) Oiling & greasing of crank gears by opening of lock circlip etc. (v) Replacement of worn out parts such as bush, rings, lock pins and latch etc. (vi) Checking & adjustment of oil daspot of breaker for its damping action. (vii) Replcement of defective pole with new one, provided by department free of cost and vacuum interrupter with new one, provided by contractor at his own cost. After repairing & overhauling of above VCBs, following tests are to be carried out :- (i) Opening & closing time of breaker of each pole. (ii) Carrying out Contact Resistance Measurement (CRM test) of each pole. (iii) Checking of megger values of breaker poles. (iv) Checking triping of breaker at 70% DC voltage. (v) Checking the CLOSE/OPEN operation of breaker from REMOTE & LOCAL. (vi) Prepare and submit the site ovehauling report of each breaker
Rates qouted by the bidders shall be without taxes. Taxes applicable if any to paid extra
SARASWAT ELECTRICALS
P&H Engineering
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .