Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC 33 PEMANTLE STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | ₹3.3 L | L1 | Accepted-AOC AOC Issued |
| 2 | L2₹4.2 LRejected-Finance NABAJIBAN 1 NABAJIBAN COLONY BISHARPARA KOLKATA 700158 WEST BENGAL | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700158 | ₹4.2 L | L2 | Rejected-Finance that the bid is not L1 |
| 3 | L3₹5.2 LRejected-Finance F IA 24 4210 CO JAYKRISHNAPUR P O BEGAMPUR DIST HOOGHLY | BEGAMPUR | HOOGHLY | WEST BENGAL | ₹5.2 L | L3 | Rejected-Finance that the bid is not L1 |
| 4 | L4₹5.4 LRejected-Finance 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | ₹5.4 L | L4 | Rejected-Finance that the bid is not L1 |
| Sl No | Description | Qty | Unit | ANIKET COOLING AND REFRIGERATION CO L2 | MILLENNIUM AIRCON L1 | CARRION AIR COOLING L4 | P. M. COOLING AND ENGINEERING CO L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | 1.5/2 Tr Split /WindowAC (Hitachi/Bluestar/OGeneral/Carrier/Daikin ) (ECG,NS Office,Doctor Room,Room No 1,2,3,4,5,6,7,8,9,10,11,13,15,16,17,18,20,21,25,26,27,28,Doctor Rest Room--1no Pathology -3Nos,Superintendent-2Nos,Assaistant Super,ENT ,VIP Cabin-4 nos,OT-8nos.(Both IPD and OPD Building) | 80 | Tr. | 85 ₹81,600 | 105 ₹1.0 L | 192 ₹1.8 L | 148 ₹1.4 L |
| 2.00 | Comprehensive Maintenance of vaious 1.5/2/ 3.75/5/5.5/6/7.5/8.5/9/12/16.5/17/22/25 Tr. CeilingSuspended/ Ductable Split/ Package Unit at different location in SDH hospital . | 155 | Tr. | 180 ₹3.3 L | 125 ₹2.3 L | 192 ₹3.6 L | 205 ₹3.8 L |
| 3.00SCOPE OF WORK 1.) Compulsory Preventive maintenance of every machine once in Two month. It includes, clearing of coils, air filters, Checking grill temperature & room temperature, current drawn, Condition of PCB,Condition & temperature of Capacitor , Drain line, Gas pressure, Cooling coil thermostat. 2.) Daily noting of the details of Preventive Maintenance Details in Maintenance register. Failing which a deduction of Rs. 1000/Month will be applicable from the bill. | |||||||
| 4.003.) The Contract covers free replacement of all spare parts including compressor (includes all type of AC Machine), capacitors, relays, thermostats, fan motors, Inside electrical wiring unit, indoor PCB, outdoor PCB, contactors, terminals,S2/P2 Type Capacitors and all others necessary parts which required at AC machine. In case of gas leakage in the system, Agency shall carry out leak test and rectify the same with gas charging. 4) Agency Should attend the Breakdown call within 1 hour. Failing which Rs. 500/machine/breakdown call will be deducted. | |||||||
| 5.005.) Incase of breakdown where replacement of spares are required, 24 hrs will be provided for spares except compressors and 72hrs will be provided only in case of compressors. 6.) Failing to meet the time line in case of breakdown where spares invlove Rs. 500/day/machine will be deducted. 7.)All the spare required to be replaced, should be of approved make. | |||||||
| 6.008.) Yearly Once complete servicing & Overhauling & oiling to be carried out of each unit after taking out from its position as per instruction of AE/JE. 9.)In case of break-down of A.C. machines, If the machine is required to be removed / shifted to Workshop hours, then a temporary AC machine of same capacity will have to install to cool the work place & no extra claim will be entertain for this temporary AC machine arrangement & dismantling. If loan machine is not provided timely by agency, a penal amount of Rs. 100/day will be deducted from the contractor’s bill till reinstallation of AC machine or as per the direction of EIC) | |||||||
| 7.0010.) The agency will have to depute minimum 1 Nos AC Technician With 1 helper for day shift & 1 Nos AC Technician With 1 helper for rest of the shifts including holidays under his direct supervision. 11.)Any damage of parts due to negligence of technician of agency (if detected), will liable for penalty. Penalty amount is the actual cost of the same parts. 12.)The contractor should have their office with Telephone number and Mobile number in Kolkata and the same should be intimated to this Department in writing, the telephone call should be responded without delay. | |||||||
| 8.0013.)The agency should provide photo identity cards to all the maintenance staff employees including substitute’s employee(s) duly signed by concerned agency & JE. 14.Agency should provide sufficient Tools and Tackles for smooth maintenance work. Zet Pump should be available at site. 15.In case of any accident and/or physical illness of the staffs of the agency, while on duty, no claim will be entertained by this department and all responsibilities thereof should be shouldered by the agency only. | |||||||
| 9.00(Rate should be quotated including all taxes and duties and GST) | |||||||
Tender Value
Refer Docs
EMD Value
₹10,400
Closing Date
18 Jan 2024, 1:00 pmClosed
EEI,KNHED, PW Dte
KIT Building Annex, 4th Floor,P-16, India Exch. Place Extn., Kolkata -700073
AMC Preventive Maintenance of Duct able Split,Hat Type and window Other AC M/C is install at Blood bank, CCU Unit and Other Building of Sub-divisional Hospital at Salt Lake, Under NKHESD
2023_WBPWD_626709_1
WBPWD/EE/KNHED/NIQ-134/23-24
Open Tender
ELECTRICAL WORKS M/R
365 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹10,400
16 Apr 2026
21 Dec 2023
22 Jan 2024
28 Dec 2023
18 Jan 2024
28 Dec 2023
Amount
1.5/2 Tr Split /WindowAC (Hitachi/Bluestar/OGeneral/Carrier/Daikin ) (ECG,NS Office,Doctor Room,Room No 1,2,3,4,5,6,7,8,9,10,11,13,15,16,17,18,20,21,25,26,27,28,Doctor Rest Room--1no Pathology -3Nos,Superintendent-2Nos,Assaistant Super,ENT ,VIP Cabin-4 nos,OT-8nos.(Both IPD and OPD Building)
Comprehensive Maintenance of vaious 1.5/2/ 3.75/5/5.5/6/7.5/8.5/9/12/16.5/17/22/25 Tr. CeilingSuspended/ Ductable Split/ Package Unit at different location in SDH hospital .
SCOPE OF WORK 1.) Compulsory Preventive maintenance of every machine once in Two month. It includes, clearing of coils, air filters, Checking grill temperature & room temperature, current drawn, Condition of PCB,Condition & temperature of Capacitor , Drain line, Gas pressure, Cooling coil thermostat. 2.) Daily noting of the details of Preventive Maintenance Details in Maintenance register. Failing which a deduction of Rs. 1000/Month will be applicable from the bill.
3.) The Contract covers free replacement of all spare parts including compressor (includes all type of AC Machine), capacitors, relays, thermostats, fan motors, Inside electrical wiring unit, indoor PCB, outdoor PCB, contactors, terminals,S2/P2 Type Capacitors and all others necessary parts which required at AC machine. In case of gas leakage in the system, Agency shall carry out leak test and rectify the same with gas charging. 4) Agency Should attend the Breakdown call within 1 hour. Failing which Rs. 500/machine/breakdown call will be deducted.
5.) Incase of breakdown where replacement of spares are required, 24 hrs will be provided for spares except compressors and 72hrs will be provided only in case of compressors. 6.) Failing to meet the time line in case of breakdown where spares invlove Rs. 500/day/machine will be deducted. 7.)All the spare required to be replaced, should be of approved make.
8.) Yearly Once complete servicing & Overhauling & oiling to be carried out of each unit after taking out from its position as per instruction of AE/JE. 9.)In case of break-down of A.C. machines, If the machine is required to be removed / shifted to Workshop hours, then a temporary AC machine of same capacity will have to install to cool the work place & no extra claim will be entertain for this temporary AC machine arrangement & dismantling. If loan machine is not provided timely by agency, a penal amount of Rs. 100/day will be deducted from the contractor’s bill till reinstallation of AC machine or as per the direction of EIC)
10.) The agency will have to depute minimum 1 Nos AC Technician With 1 helper for day shift & 1 Nos AC Technician With 1 helper for rest of the shifts including holidays under his direct supervision. 11.)Any damage of parts due to negligence of technician of agency (if detected), will liable for penalty. Penalty amount is the actual cost of the same parts. 12.)The contractor should have their office with Telephone number and Mobile number in Kolkata and the same should be intimated to this Department in writing, the telephone call should be responded without delay.
13.)The agency should provide photo identity cards to all the maintenance staff employees including substitute’s employee(s) duly signed by concerned agency & JE. 14.Agency should provide sufficient Tools and Tackles for smooth maintenance work. Zet Pump should be available at site. 15.In case of any accident and/or physical illness of the staffs of the agency, while on duty, no claim will be entertained by this department and all responsibilities thereof should be shouldered by the agency only.
(Rate should be quotated including all taxes and duties and GST)
ANIKET COOLING AND REFRIGERATION CO
P. M. COOLING AND ENGINEERING CO
CARRION AIR COOLING
stage.html
html • 0.05 MB
technical_1340536.pdf
techsummary_1340536.pdf
finance_1340536.pdf
BOQ Comparative Chart
xlsx
finsummary_1340536.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.46 MB
suspension.pdf
Additional Documents • 2.91 MB
2911_Form.pdf
Tender Documents • 0.50 MB
BOQ_1340536.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid