Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹12.9 L+₹48,783 (3.92%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹13.4 L+₹98,375 (7.90%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹14.0 L+₹1.6 L (12.5%)Rejected-AOC | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹14.9 L+₹2.4 L (19.4%)Rejected-AOC | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
₹15.5 L
EMD Value
₹31,000
Closing Date
17 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ CWE Rajouri PIN-900129 C/o 56 APO
PROVN OF 100 KVA TRANSFORMER FOR BG GRN UNDER GE 881 EWS
2022_MES_505296_1
CANO-CWE/PNH-64/2021-22
Open Tender
Support/Maintenance Service
Item Rate
180 days
BG AOR of GE 881 EWS
Class E category b(ii)
9 documents required · 9 mandatory
₹500
GE 881 EWS
₹31,000
Yes
18 May 2022
2 Feb 2022
24 Mar 2022
2 Feb 2022
17 Mar 2022
16 Feb 2022
60 days
Amount
Supply, installation, testing & commissioning of copper wound transformer step down, outdoor type oil cooled, complete with standard fittings, HT 11kv 3 phase, LT 433 Volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage with-in limit all as per IS:1180 Part -I and minimum 4 star rating BEE specification of capacity up to 100 KVA, complete all as specified and directed.
M&L for Construction of platform suitable for 100 KVA Transformer / Voltage stabilizer of size 2.0m x 2.0m x 0.6 m (Plateform shall be made out of brick masonary one feet below ground level and one feet above ground level hollow space and to filled by PCC 1:3:6 type C-2 laid over well rammed earth with & including 100 mm thick cement concrete 1:2:4 type B-2 finished even & smooth without using extra cement as in floor of platform, plastering in CM 1:4 all round, complete all as specified and directed.
Supply and fix Voltage stabilizer outdoor type for automatic operation, three phase for unbalanced load naturally oil cooled, outdoor type & designed for input variation between 210 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 100 KVA, complete all as specified and directed. Note:- Voltage stabilizer shall be copper wounded.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core, complete all as specified and directed.
Switch air break gang operated triple pole mechanically operated from ground level mounted on 12 insulators, outdoor type suitable for vertical installation single break provided with locking arrangement for operating handle including seven levers “Navtal” lock consisting of mid steel channel 75 mm, HT post Top insulator copper alloy high pressure assembly with drop out expulsion fuses for phases, operating rod of 20mm dia medium grade GI pipe complete conforming to IS-1018 of 1972 with continuous current rating 400 Amp, 11000 volts grade complete all as specified and as directed.
Lightning arresters expulsion type complete with all fittings, transmission class, dies-charge capacity 65 kilo amp for working pressure 11000 Volts, complete all as specified and directed.
Cross arms, bracings, supports, clamps (including stay clamps, clamps for fixing GI tubes for passing through of cables) and back plates fabricated out of standard steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as directed and inclusive of providing two coats of aluminium paint over a coat of red oxide primer after preparation of steel surfaces complete all as specified and directed.
Steel tubular poles, swaged type, 410 SP-55, 11m long with 300x300x6mm thick MS base plate continuously welded to bottom of pole & MS sheet 2mm thick plug finial taper welded at top, including drilling of holes of required size and nuts for fixing of cross arms all as specified including two coats of black bituminous paint internally throughout and externally for embedded portion and two coats of aluminium paint over a coat of red oxide primer on exposed surfaces including painting up to 1.5 mtr height from ground level or above coping with two coats of synthetic enamel paint in 30cm strip, alternate balck & white starting with block at ground level, complete all as specified and directed. (Note:- Excavation and earth work and PCC shall be measured & paid separately)
Disc type insulator, porcelain, vitreous 145mm high and 225mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts, complete all as specified and directed.
Loop type insulator, vitreous porcelain, white, brown or green Large size, with overall dimensions 90mmx140mm, clearance of hole 25.5mm, complete all as specified and directed.
Stay assembly complete with accessories i.e stay plate 300mm x 300mm x 6mm, galvanized thimbles,bow stay rode of 20mm dia etc and all other accessories as shown in electrical plate No.1 on Ser Page No.19-47 of MES Schedule Part-I complete. Note : Stay wire, excavation and earth work and concrete for stay pit and insulator shall be measured and paid for separately.
Stay wire stranded 7/3.15mm including stay clamp and fixing arrangement complete all as specified
ACSR condutor of any size including stretching, fixing and binding to insulator on OH over head line including necessary aluminium binding wire or tape, jumpering, maintaing proper sag as per IE Rule including cutting of tree branches around the ACSR with in area of 2 mtr dia all as specified and as directed.
Supply laying, commissioning and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade (earthed) of cross sectional area 95 sq mm 3 core complete all as specified and as directed.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Heat Shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm, complete all as specified and directed.
80mm GI pipe light grade laid in trenches under road/foot path or fixed on pole with necessary clamps with nut, bolts etc complete all as specified and directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
Earthing for poles and other machinery/eqpt using GI strip as earth lead and MS galvanized steel earth plate electrode 600x600x6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 32x6mm with GI pipe, nuts, bolts and washers complete upto and including test point made out of 40x3mm GI flat, PCC pit of required size in PCC 1:2:4 type B1 and RCC cover reinforce with 8mm TMT bar @ 150mm c/c with frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, charcoal, common salt 15cm at round the earth plate watering pipe 20mm med grade/galvanized and 40mm dia GI pipe light grade for GI strip protectetion, funnel with wire mesh including testing on completion, complete all as specified and directed as shown in electrical plate No 3 of SSR Part-I 2009.
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 in depth for cable laying, foundation of poles, stay assembly etc. and getting out in any type of soil /PCC/Road cutting complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick each complete all as specified and directed.
Removing excavated material to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point of any type of soil complete all as specified and directed.
Dry sand cushioning to UG cable 8 cm thick before laying and 15cm thick after laying complete all as specified and directed. Note:- (i) Dry fine sand of best available quality shall be used. (b) Punned thickness shall be made and paid.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
Plain cement concrete (PCC) type C-2 1:3:6 using 40mm graded aggregate stone for making foundation of Pole/stay assembly ,filling and mass concrete, complete all as specified and directed.
Plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed.
Supply, installation, commisioning and testing out door type LT Panel of suitable size, made out of mild steel CRCA sheet of 3.15 mm thick with angle iron frame of size 50mm x 50mm x 6mm with canopy top, two side ventilators, front openable hinged double door shutters with locking arrangement, weather & vermin proof suitable for working on 440 volts AC supply including bus bar chamber and aluminium bus bar of suitable size 4 Nos mounted on hygroscopic insulators fixed in separate bus bar chamber and seperate compartment for incomming and outgoing feeder, all pre wired with suitable size of copper conductor cable including painted with two coats of powder coated synthetic enamel paint over a coat of red oxide zinc chrome primer on out side surface and two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer on internal surfaces including provision of lugs and cable gland for housing with the following fitment accessories as mentioned in below:-. Note-Panel shall be approved by CPRI .
RAVI KUMAR
M/S PARSHOTAM KUMAR GUPTA
Jiwan Singh
M/S NARAYAN CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .