| 1 | L1₹52.9 LAccepted-AOC WZ143 A 7 A S 4 43 GALI NO 2 OLD MAHABIR NAGAR NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L1 | Accepted-AOC Accepted being lowest quoted tenderer | |
| 2 | L2₹63.3 L+₹8.6 L (15.6%)Rejected-AOC | L2 | Rejected-AOC Rejected being other than lowest quoted tenderer | |
| 3 | L3₹67.8 L+₹13.0 L (23.7%)Rejected-AOC HIG 40 TYPE B DEV PRAYAGAM ADA COLONY JHALWA PRAYAGRAJ U P 211015 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211015 | L3 | Rejected-AOC Rejected being other than lowest quoted tenderer | |
| 4 | L4₹68.7 L+₹14.0 L (25.5%)Rejected-AOC | L4 | Rejected-AOC Rejected being other than lowest quoted tenderer |
| Sl No | Description | Qty | Unit | DINESH ELECTRICALS L2 | R K CONSTRUCTION COMPANY L3 | KHALSA BUILDER L4 | M/S Sunil Steel Works L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick work built in cement mortar of any description including all quions arches, pillars, etc complete all as specified and directed. | 59 | Cum | 450 ₹26,550 | 175 ₹10,325 | 100 ₹5,900 | 50 ₹2,950 Lowest |
| 2.00 | Taking down cement plaster on brick or stone walls incl wall tiles etc. with raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed | 400 | Sqm | 45 ₹18,000 | 20 ₹8,000 | 25 ₹10,000 | 10 ₹4,000 Lowest |
| 3.00 | M&L for brickwork with sub class 'B' bricks (old size), straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed. | 4 | Cum | 3,500 ₹14,000 Lowest | 4,400 ₹17,600 | 5,000 ₹20,000 | 3,500 ₹14,000 Lowest |
| 4.00 | M&L for half brick work with sub class 'B' bricks (old size) straight or curved on any radius built in CM 1:4 complete all as specified and directed. | 15 | Sqm | 550 ₹8,250 Lowest | 600 ₹9,000 | 2,000 ₹30,000 | 650 ₹9,750 |
| 5.00 | M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4, all as specified and directed. | 55 | Cum | 3,600 ₹1,98,000 | 4,500 ₹2,47,500 | 4,000 ₹2,20,000 | 3,200 ₹1,76,000 Lowest |
| 6.00 | M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces complete all as specified and directed | 200 | Sqm | 135 ₹27,000 Lowest | 200 ₹40,000 | 140 ₹28,000 | 145 ₹29,000 |
| 7.00 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces complete all as specified and directed | 150 | Sqm | 145 ₹21,750 | 250 ₹37,500 | 130 ₹19,500 Lowest | 150 ₹22,500 |
| 8.00 | M&L for rendering 10mm thick in CM 1:3 on ceiling surfaces of RCC or brick complete all as specified and directed. | 50 | Sqm | 125 ₹6,250 Lowest | 200 ₹10,000 | 150 ₹7,500 | 140 ₹7,000 |
| 9.00 | M&L for preparation of newly plaster surface of wall and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty complete all as specified and directed. | 200 | Sqm | 40 ₹8,000 | 100 ₹20,000 | 35 ₹7,000 Lowest | 45 ₹9,000 |
| 10.00 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint on new plastered surfaces having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm Note- Primer and emulsion to be carried out through air less spray machine. | 150 | Sqm | 65 ₹9,750 | 120 ₹18,000 | 60 ₹9,000 | 45 ₹6,750 Lowest |
Tender Value
₹71.3 L
EMD Value
₹1.3 L
Closing Date
15 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Prayagraj
HQ CWE New Cantt Prayagraj
SPECIAL REPAIR TO GOVT ACCN T-24 TO T-26 AND T-27 TO T-34 (11 OR MD ACCN) AT RA LINE NEW CANTT UNDER GE WEST) PRAYAGRAJ.
2025_MES_736075_1
82036/W/E8
Open Tender
Civil Works
Item Rate
180 days
Prayagraj
Class C and Category a(i)
6 documents required · 6 mandatory
₹1,000
GE (West) Prayagraj
₹1.3 L
Yes
18 Mar 2026
18 Oct 2025
22 Nov 2025
18 Oct 2025
15 Nov 2025
8 Nov 2025
Amount
Demolition of brick work built in cement mortar of any description including all quions arches, pillars, etc complete all as specified and directed.
Taking down cement plaster on brick or stone walls incl wall tiles etc. with raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed
M&L for brickwork with sub class 'B' bricks (old size), straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed.
M&L for half brick work with sub class 'B' bricks (old size) straight or curved on any radius built in CM 1:4 complete all as specified and directed.
M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4, all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces complete all as specified and directed
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces complete all as specified and directed
M&L for rendering 10mm thick in CM 1:3 on ceiling surfaces of RCC or brick complete all as specified and directed.
M&L for preparation of newly plaster surface of wall and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty complete all as specified and directed.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint on new plastered surfaces having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm Note- Primer and emulsion to be carried out through air less spray machine.
M&L for preparation of newly plaster surface of ceiling and applying two coats of white wash complete all as specified and directed.
M&L for preparation of newly steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L preparation of new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Complete removal of existing treatment on wall/ roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean,free from dust, loose paint etc by skilled labour complete all as specified and directed.
M&L for wall care putty @ 1 Kg(undiluted) per sq mtr. of average thickness 1 mm, over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete and . Sanding of the putty surface with Asian Paints TruCare Wall Sander: L- 01/H-01 or equivalent (having mechanical vacuum mechanism) having RPM not less than 1500, sannding pad of 240 Grit or above having dia of 7"/9" to make the surface free from dust etc. by skilled labour. Step 1) Mix the putty powder by adding 40-50% water and mix it with Asian Paints Trucare Putty mixer(Trucare Putty mixier with min 1400 W power havinng mixer rod of industrial stell grade 45 with the mixing capacity of min 2.5 kg putty per minute). Step 2)Apply the first coat the prepared mixer with the help fully automatic airless spray machine of putty application of Asian Paints Trucare Graco Spray Machine(Model: EH 230 DI) or equivalant having a DC electric motor of 3.3 KW having flow speed of max 6 ltrs per minutes with a maximum pressure 230 bar having maximum tip size 0.041" Step 3) Allow 6-8 hrs time to dry the putty surface.
M&L for preparation of old surface of walls and applying one coat of white wash on wall complete all as specified and directed.
M&L for preparation of old decorated surface of ceiling and applying one coat of white wash on ceiling complete all specified and as directed.
M&L for preparing old decorated surfaces of wall and applying one coat of oil bound distemper white or tinted complete all as specified and directed.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm Note- Primer and emulsion to be carried out through air less spray machine ( Mechanical means) complete all as specified and directed.
Dismantling of floor hearth or wall tling including cement mortar bedding (but not backing), removing servicesable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for 25 mm thick plain cement concrete type B-0 1:2:4 (12.5mm graded crushed stone aggregate) as in levelling course of floor and other similar works complete all as specified and directed.
M&L for non skid coloured ceramic floor tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but n exc 0.11 sqm,in floor ,wall etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface with & including 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M&L for double charged vitrified tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface with & including 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M&L for glazed ceramic coloured wall tiles in vertical surface 450X300X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in 1:4 CM complete all as specified and directed.
M&L for 16 to 18 mm thick granite stone for any type of work in steps, jambs, wall clading, window sill, pillars, cooking platform and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over & including 20mm screed bed in CM 1:4 complete all as specified and as directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations compete all as specified and as directed.
Demolition of cement concrete including floor tiles or stone in any description and any position etc removal from site and complete all as specified and directed
M&L for 75 mm thick cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in plinth protection finished even and fair including necessary form work and cutting of joints using extra cement etc complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in surface channel or surface drain including forming and finishing with extra cement including taking down existing concrete complete all as specified and directed.
M&L for RCC type B-1 1:2:4 using 20mm graded crushed stone aggregate as in kitchen shelves etc including demolation of old slab complete all as specified and directed.
M&L for form work to suspended slab as in kitchen shelves etc complete all as specified and directed.
M&L for TMT bar 10 mm dia and over, cut to length, bent to shape required ,including cranking ,bending spirally for hooping for columns,hooking end and binding with and including mild steel wire and annealed not less than .9 mm dia or securing with clips complete all as specified and directed.
M&L for Sunken floor treatment as in following sequence:- (a) The surface of Sunken floor is to be properly cleaning the dust,durt and any other foreign material,fungus moss etc from the surface. (b) M&L for 10mm thick plaster in CM 1:3, mixed with liquid water proofing compound over concrete surface of sunken area when concrete is green. (c) Applying a coat of bituminous primer @ 0.40 ltr / Sqm uniformily and primer shall be allowed to dry over night as conforming to IS 3384-1986. (c) M&L for APP based polymeric water proofing membrane of 3mm thick (reinforced with non-woven fabric polyester type) (weight not less than 3 kg per sqm) shall be done using butane torch maintaining 100mm side overlap and 150mm end overlap,sealing all overlaps including at all junction and corners with bonded to the surface by fusing and bonding torchon method complete all as specified and directed. Note:- Treatment of Sunken floor shall be done from approved manufacturer.
M&L for cement concrete 1:5:10, type E-2 (40 mm graded crushed stone aggregate) as in sunken filling and mass concrete works complete all as specified and directed.
M&L for 32 mm bore galvanised steel tubes 'medium grade' as in sunken spout pipe complete all as specified and directed.
Cutting holes in full brick walls, built in cement mortar for inserting of sunken pipe , holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
S&F in repair rotational moulded polyethylene water storage tank of capacity 500 ltr (Cylindrical/vertical with closed top) double layer construction, ISI marked hoisted & fixed in position including dismantling of old tank and removing from site complete all as specified and directed.
S&F in repair ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 20mm bore minimum weight 210 gms complete all as specified and directed.
S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including 'P' or 'S' trap complete all as specified and directed.
S&F in repair vitreous china wash and basin, white, flat back, size 550 mm x 400 mm fixed on existing bracket, fixing of tap, waste fitting,pipe and union complete all as specified and directed.
S&F in repair PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float & handle, waste pipe & brackets complete set all as specified and directed.
S&F in repair PVC connection 450 mm long, 15 mm size with brass chromium plated nuts complete all as specified and directed.
Demolition of reinforced concrete Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Taking up or down 15 mm bore GI steel tubing and connections on (walls, ceiling, floors, etc.) including cleaning complete all as specified and as directed
Refixing old 15 mm bore GI steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) with & including new fittings complete all as specified and as directed
S&F 15 mm bore GI steel tubing "medium grade" with all fittings and fixed to wall, floor and ceiling etc complete all as specified and directed.
Taking up or down 20 mm bore GI steel tubing and connections on (walls, ceiling, floors, etc.) including cleaning complete all as specified and as directed
Refixing old 20 mm bore GI steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) with & including new fittings complete all as specified and as directed
S&F 20 mm bore GI steel tubing "medium grade" with all fittings and fixed to wall, floor and ceiling etc complete all as specified and directed.
S&F in repair for 15mm bore bib taps chromium plated with crutch or butterfly handle ,screwed down , screwed for iron pipes or brass ferrule complete all as specified and directed.
S&F in repair CP angle stop valve or cock of 15mm bore screwed down for high pressure with crutch or butter fly handle ,screwed both end for iron pipes complete all as specified and directed.
S&F in 15 mm bore CP central hole basin mixture (swan neck/head type) with regular spout fancy type, cast copper alloy with capstan heads,long screwed shanks and fly nuts screwed for iron pipe fixed complete all as specified and directed.
S&F in repair Wall mixer with provision for overhead shower with 115 mm bend pipe on upper side,connecting legs and wall flanges complete all as specified and directed.Make : Jaquor cat part COP -273PM or equivalent Cat Part as make specified in list of make complete all as specified and directed
S&F in repair for 90 to 125 mm size fancy type chromium plated shower rose with swivel joints,and connecting rod including fixing to steel pipe or union complete all as specified and directed.
S&F in repairs 600 mm long tubular towel rail , brass chromium plated of 20 mm dia complete all as specified and directed.
S&F in repairs Stainless steel grating dome 100 mm dia with or without waste holes as required complete all as specified and directed.
S&F in repair 32 mm bore low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqcm white in colour fixed in repairs to walls or laid in floors including all fittings such as bend, elbow, tee etc.
S&F in repair 20 mm dia Stainless steel curtain rod of wall thickness not less than 1mm with both side decorative brakets and fixing brakets complete all as specified and specified.
S&F in repair stainless steel sinks with drainage board of 1mm thick in kitchen or laboratory with plug washers and waste pipe including bedding in cement mortar to dwaft wall or including fixing cantilever brackets and connecting union or waste fitting to pipe over all size 915mm x 460mm bowl size 410mm x 330 mm x 160mm complete all as specified and directed.
S&F in repair stainless steel plate rack (utensil rack) of size 900mm X 750mm X 260mm made out of stainless steel 0.63mm thick fixed with brass screw complete all as specified and directed.
Cutting holes in brick walls in brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar for purpuse made cutting and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required in full brick wall complete all as specified and directed.
S&F in repairs 110 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trench complete all as specified and directed.
S&F in repairs 75 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trences complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed.
S&F in repairs PVC (SWR) floor trap plain or multi with stainless steel grating incl joinig to waste pipe with solvent cement joint dia of outlet 75 mm bore complete all as specified and directed.
Taking down chowkat with shutter (without taking off shutters from the frame) area not exc 1.5 Sqm each and removing from site complete all as specified and directed.
Taking down chowkat with shutter (without taking off shutters from the frame) exc 1.5 Sqm but not exc 4.0 Sqm each and removing from site complete all as specified and directed.
S&F hollow 125x60mm Pressed steel MS steel double / single rebated door frame including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, approved shape and size complete all as specified and directed.
S&F hollow 105x60mm Pressed steel MS steel double / single rebated door frame including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, approved shape and size complete all as specified and directed.
M&L for 32 mm thick flush shutter,solid core construction with block board core and plywood face panels,commercial type on both sides complete all as specified and directed.
S&F 35 mm thick factory made 2nd class hard wood glazed and skeleton shutters, open repeated and prepared to receive glass, gauze etc (with sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc, size of member of shutter as per specified in SSR part-I section 8,clause 8.24(a) and for door and fixed with chowkats,chemically pressure treated complete all as specified and directed.
M&L for factory made uPVC white color sliding window three track made of extruded profiles with wall, thickness of profiles not less than 2.3mm with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm) interlock (One vertical length in each shutters 45.5mm x 28mm), glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc, making arrangement for fixing of hardware, EPDM gasket, 1.2mm +/- 0.2 mm thick galvanised steel frame (30mm x 18mm) of 2 Nos, sliding sash (30mm x18mm) sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners hardware touch lock of zinc alloyed (white powder coated) steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and required accessories and 5.0 mm thick coloured glass pans and required necessary fittings complete all as specified and directed.
S&F factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawingcomplete all as specified and directed.
S&F 100 mm long mild steel butt hinges, cold rolled, medium weight complete all as specified and directed.
S&F 100 mm long stainless steel butt hinges with steel pin complete all as specified and directed.
S&F for 200mm long anodised aluminium barrel tower bolt of extruded section complete all as specified and directed.
S&F 300mm long, aluminium alloy, anodised aldrop door bolt including fixing clips of sheet, cast or exturded section and fixing bolts and 16mm dia bolt of sliding bolts of extruded sections complete all as specified and directed.
S&F 150mm long aluminium alloy floor door stopper ,fabricated type complete all as specified and directed.
S&F including fabrication of framed work such as in grills, grating ,hold fast of door and window chowkat etc., with ends of bars shouldered and or riveted or forget into spikes, frames guard bars, barred iron doors, and similar work conforming toFe 290 Gde-E-165 complete all as specified and directed
S&F of galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks of galvanised wire staples complete all as specified and directed.
S&F 18mm thick WPC board minimum 600 Kgbm density grade 1 quality one side pre-laminated and other side plain white colour to make kitchen cabinet/drawer shutters/CB shutter fixed with screws, solvent cement/adhesive as per manufacturer instructions complete as per specifications and as directed by the Engineer-in-Charge.
S&F 30mm width of flaps continuous (piano) hinges, mild steel, bright finish or electro galvanised complete all as specified and directed.
S&F 100 mm hasp & staple sfety type of stainless steel including bolt to hinges plate and fixed with screws complete all as specified and directed.
S&F 100mm size stainless steel handle cast type polished bright complete all as specified and directed.
Dismantling of brick tiles any thickness laid, bedded and pointed in any mortar from roof including removal of old tarfelt and mudfuska complete (cost of necessary scafolding and removal of the material obtained from site to outside the premises deemed to be included in the rate) complete all as specified and directed.
Demolition of cement concrete in roof including mud phuska and plastering and leeping including cleaning surface of roof with wire brush / mechanical brush throughly to remove old dirt / loose particles to expose clean concrete slab clean with watering etc complete all as specified and directed.
M&L for cutting out cracks to V section in existing roof or terracing, cleaning out, wetting, grouting with cement and sand slurry in 1:3 complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.50mm graded crushed stone agg with WPC as in padding to maintain proper slope as required al as specified (WPC shall be paid separatly.) complete all as specified and directed.
Roughening surfaces of old concrete roof by iron brush and picking, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry with 3.0 Kg of cement per Sqm complete all as specified and directed.
M&L for 15mm thick rendering on roof surface of mortar in CM 1:4, using Liquid Water Proofing Compound as per manufacturer's instruction, laid in roof (WPC shall be paid separately) complete all as specified and directed.
M&L for priming roof surfaces and applying a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg/sqm except felt and laying APP based polymeric membrane with 100mm side laps/end laps and minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150gms/sqm) over roof surfaces by force application complete all as specified and directed.
M&L 40mm thick brick tiles laid on cement mortar 1:6 and grouted flush in CM (1:3), mixed with 5% of crude oil by weight og cement on 15mm thick screed bed complete all as specified and directed.
All as per item No. 98 above but except tile complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in roof kerbs etc rounded or chamfered on edges complete all as specified and directed.
Excavation in post holes ( or similar holes) in soft/loose soil each n. exc 0.50 Cum getting out, watering and removing surplus soil to a distance n. exc 50 m and making good surface complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) in filling of post holes complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground as complete all as specified and directed.
Dismantaling of old chain link fencing including line wire of mesh of any thickness, fixed with steel or RCC post if any complete all as specified & directed.
M&L for angle iron post and struts in fencing including cutting tops to shape as directed, drilled holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc.)including all necessary drilling,bolting or riveting screws, etc and similar work complete all as specified and directed.
fixing only chain link MS galvanised fencing any size or type as required complete all as specified and directed.
Supply only chain link MS galvanised fencing any size or type complete all as specified and directed.
S&F MS 10 mm dia round bar and fixed independently to angle iron for chain link fencing cut to length, bend to shape reqd and directed including taking down old rusted part complete all as specified and directed.
S&F galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standared rails straining bolts including securing or tying at crossing with and provn of galvanised mild steel wire, staples or steel pins, etc as directed (each line wire to be measured) complete all as specified and directed.
M&L for PCC type E2 1:5:10 using 40mm graded crushed stone aggregate as in sub base complete all as specified and directed
M&L for 80mm thick M-40 grade factory made rubber moulded vaibratory cement concrete coloured interlocking paver block any shape and size conforming to IS 15658-2006 with grey cement and pigment as approved laid over and including 25mm thick sand cushion and joints filled with sand complete including dismantling of tiles complete all as specified and directed.
Taking down carefully aluminium / copper point wiring any type for one light , fan, socket power point or buzzer controlled by one switch complete including fitting / fixtures such as switches, ceiling roses, holder, socket, light fitting etc; for credit and making good disturbed surfaces of walls, ceilings etc complete all as specified and directed.
M&L for point wiring with concealed in wall 2.5 sqmm (nominal area) FRLSH PVC insulated unsheathed stranded copper conductor single core including non metalic PVC conduit medium grade of appropriate size concealed in wall and modular sunken box, cover plate/frame any module as required at site with all accessories as specified including 2.5 Sqmm FRLSH PVC insulated unsheathed multistranded copper earth conductor to common earth and connected to earth dolly for fan / light / exjaust fan/ bell point controlled by one switch and single conduit shall be used for each circuit. Note:- 1. Cost of PVC conduit, with connected item to be included in the quoted rate. 2. M&L for cutting chases on walls / ceiling and making good disturbed surfaces including finishing with cement mortar (1:3) etc; are deemed to be included in the quoted rate. 3. Modular metal box, cover plate & frame for any module to be included in the quoted rate.
All as per item No. 113 here-in- before but for 3 pin 5 Amps switch socket on independent board with 2.5 sq mm copper cable.
All as per item No. 113 here-in- before but for 3 pin 15 Amps switch socket on independent board with 2.5 sq mm copper cable including 2.5 Sqmm FR PVC insulated unsheathed multistranded copper earth conductor to common earth.
All as per item No. 113 here-in- before but for 3 pin 15 Amps switch socket n on independent board with 4 sq mm copper cable including 4 Sqmm FR PVC insulated unsheathed multistranded copper earth conductor to common earth.
All as per item No. 113 here - in - before but for 5 Amps socket point on the same board controlled by one switch.
All as per item No. 113 here - in - before but for one light point controlled by two, two way switch with 1.5 sq mm copper conductor cable.
S&F modular switch 1 way, 6 amps, 230V AC, one module complete all as specified & directed.
S&F modular socket out let 2-in-1, 3 pin, 6 amp flush type 2 module complete all as specified & directed.
S&F modular switch flush type 16 amps, 230V AC single pole one module complete all as specified & directed.
S&F modular socket out let 2-in-1, 3 pin, 5 & 16 amp flush type 2 module complete all as specified & directed.
S&F modular switch 2 way, 6 amps, 230V AC, one module complete all as specified & directed.
S&F modular bell push flush type 6 amp, 1 module SP , 230V AC complete all as specified & directed.
S&F Call Bell Dingdong type AC 230 Volts single pole complete all as specified & directed. Make Anchor/havells/legrand.
S&F Ceiling rose surface backelite three terminals PVC/Polycorbonate insulated body, complete all as specified & directed. Make Anchor/havells/legrand.
S&F modular fan regulator, 5 stepped, electronic type, single phase, 120 watt, socket size incl connection complete complete all as specified & directed.
S&F LED tube light fittings (inverter type) decorative ultra slim linear fixture,20 Watt, efficiancy 120 Lm/watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps all as specified and directed.
Supply & fixing energy efficient LED light of 10 Watt of length - 02 Feet long, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed.
Supply & fixing wall mounted fitting fancy type (City -2 type) with 9 watt LED bult inverter type including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed.
S&F Lamp holder insulated body PVC/polycarbonate with back plate and 9 W LED bulb inverter type suitable for batten fitting complete all as specified and directed
S&F on wall building security light luminaire for 1x35 w LED with deep drawn housing complete with and including cable for connection from ceiling rose with 3 core 1.5 Sqmm PVC insulated stranded copper conductor including bracket made out of 32 mm bore GI Light grade 1.20 M long to required shape as in bracket for to shape fixed on wall/pole with two pair of MS flate iron clamp of size 50mm X 6 mm thickness of required shape with nuts, bolts and washers including painting complete and taking down unserviceable one all as specified and directed.all as specified.
Supply and fixing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and if required down rod as per site requirement and dismantling old ceiling fan deposited at MES store yard complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers including antidust painting complete including cutting holes on wall, making good and finishing of disturbed surfaces matching with the exisitng surfaces, necessary fixing arrangements such as fastener bolts, nuts, washers etc; of appropriate size all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250m including including cutting holes on wall, making good and finishing of disturbed surfaces matching with the exisitng surfaces, necessary fixing arrangements such as fastener bolts, nuts, washers etc; of appropriate size all as specified and directed.
Supply and fixing in replacement of factory made epoxy polyester powder coated distribution board TP & N 4 way (vertical load line distribution board) with metal double door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for 4 pole MCCB 100Amp 25 KA - 01 fixed type Nos and SP MCB 63 Amps 'C' curve 10 KA - 12 Nos outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB all as specified. Note :-(a) MCB and MCCB cost shall be included under respetive item of sch. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F in replacment of factory made, sheet metal enclosure distribution boards, double door type, protection class ( IP-42), suitable for mounting MCBs confirming to IS-13032, IS-8623, BS-5484 with min 200 Amps rating copper bus bar ,SP&N 8 ways ,220 volts complete all as specified and directed. Note: MCB/ shall be measured and paid seperatly under respective item of this schedule
Supply and fixing in replacment of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing in replacment of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40/63 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
M&L in replacment of two single core (submain) FRLS PVC insulated cable of 6.00 Sqmm nominal dia and one single core green PVC insulated copper conductor earth continuity cable of 6.00 sqmm nomianal dia as mentioned below is drawn in and including non metallic, medium duty, rigid PVC conduit not less than 20 /25mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as directed. Note :- (i) The cost for cutting, chases required and suitable lugs shall deemed to be included in the quoted unit rate. (ii) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 4mm dia as earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- 2009 with 15 mm dia medium grade GI pipe as a protection to earthing lead and 20 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion. Notes (i) The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I (ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth lead wire and GI pipe for protection of earth wire. Any varriation in quantity shall be adjusted.
Supply and fix electric water heater, storage type steel body with inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc., complete all as specified and directed.
Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm, 3.5 core complete all as specified and directed. Note: 1. Excavation and earth work will be measured and paid seperately.
Excavation in trenches, in any type of soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth , laying of cable or pipes (where provided for protection of cable) etc and getting out trimming the sides, forming bottom surfaces to required level complete all as specified and all as directed.
M&L for 40 mm dia GI tubing light grade with all necessary fittings laid in trenches, fixed to walls/ poles/ under road/ floor etc for cable protection, complete all as specified and directed.
M&L for sand cushioning with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laid flat across the cable length laying of cable in trenches complete all as specified and directed.
Supply and laying of well burnt bricks, sub class 'B' laid flat in trenches for protection of cable complete all as specified and directed.
Returning and filling including spreading, levelling, watering and well ramming in layers not exceeding 25 Cm thick all as specified and directed by Engr-in-Charge.
Removing of surplus soil to a distance not exceeding 50 Mtrs and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified.
Taking down carefully energy meter after disconnecting the electrical connection, refixing or replacement the energy meter in same position including all electrical connection and material and labour all as specified and as directed.
DINESH ELECTRICALS (BID ID -3475235)
R K CONSTRUCTION COMPANY (BID ID -3475248)
KHALSA BUILDER (BID ID -3480297)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Tenderdocument.pdf
Tender Documents • 0.66 MB
Specialcondition.pdf
Additional Documents • 0.49 MB
Particularspecification.pdf
Additional Documents • 1.07 MB
Makes.pdf
Additional Documents • 0.59 MB
BOQ_824217.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .