Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC | ₹36.7 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹37.7 L+₹1.0 L (2.79%)Rejected-Finance | ₹37.7 L+₹1.0 L (2.79%) | L2 | Rejected-Finance Rejected in AOC |
| 3 | L3₹39.7 L+₹2.9 L (8.02%)Rejected-Finance | ₹39.7 L+₹2.9 L (8.02%) | L3 | Rejected-Finance Rejected in AOC |
| 4 | L4₹40.8 L+₹4.1 L (11.2%)Rejected-Finance | ₹40.8 L+₹4.1 L (11.2%) | L4 | Rejected-Finance Rejected in AOC |
| 5 | L5₹47.0 L+₹10.3 L (28.1%)Rejected-Finance WARD NO 02 LAKHUWALI PO THE PILIBANGAN DISTT HANUMANGARH RAJASTHAN 335803 | HANUMANGARH | RAJASTHAN | 335803 | ₹47.0 L+₹10.3 L (28.1%) | L5 | Rejected-Finance Rejected in AOC |
Tender Value
₹42.3 L
EMD Value
₹84,600
Closing Date
19 Oct 2021, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Special repair / replacement of solar lights at SASF Birdhwal, LT OH line into underground cable for security light and certain sanctioned works at Suratgarh Mil Stn under GE (Army) Suratgarh
2021_MES_478434_1
GE (A) SOG - 37/21-22
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹84,600
Yes
14 Dec 2021
28 Sept 2021
21 Oct 2021
28 Sept 2021
19 Oct 2021
5 Oct 2021
Amount
Demolition of plain cement concrete in ground floor and pavings not exc 15 cm thick (below or above ground level) including floor tiles of any description complete all as specified and directed by Engineer-in-charge.
Dismantling existing unserviceable Aluminium conductors, steel reinforced (ACSR conductor) from overhead lines on LT poles, of any type and any size complete all as specified and as directed by Engineer-in-charge
Dismantling existing unserviceable service bracket any type and any size on LT / HT poles complete all as specified and as directed by Engineer-in-charge.
Taking down street /security light fitting such as Energy saving light fitting 4x24 watt and 45/60/72/90 watt LED light fittings complete all as specified and directed by Engineer-in-Charge.
Disconecting and taking down existing unserviceable solar light fitting of 9/12/15/20 wattt including battery with GI/ Polycarbonate battery box & solar panel, etc complete all as specified and as directed by Engineer-in-charge.
Taking down LED security /street light fitting safely for reuse and refixing the same on new pole including connection with cable PVC insulated stranded copper conductor, 1100 volts grade, 2.5 sqmm 3 core size of ISI marked from security light to pole box along with accessories as directed by Engineer-in-charge.
Dismantling existing unserviceable cross-arms of M.S. channel or angle sections etc. of any size and type complete all as specified and as directed by Engineer-in-charge.
Dismantling and taking down insulators of any type and size complete all as specified and directed by Engineer-in-Charge. Note for Srl Item No 2 to 8:- (i) Any T & P and Ladder wheel required for the work shall be arranged by the Contractor. The rate of this aspect is included in this item and nothing extra shall be paid on this account.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
S&F 450mm long PVC connection suitable for 15 mm bore with PTMT nuts on both sides complete all as specified and directed by Engineer-in-charge.
S&F 15mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge.
S&F 15 mm bore bib tap, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge.
S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
M&L for making connection from existing GI water pipe line of size 15mm bore and insertion of GI Tee of size 15x15x15mm including earth work making joints and jointing material etc complete all as specified and directed by Engineer-in-charge.
M&L for point wiring complete with 2.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including new PVC rigid conduit medium grade 20mm dia and suitable fittings, fixed on surface of wall or concealed or above ceiling with accessories such as pipe hooks, elbows, junction box, terminated in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 2.5 sqmm PVC insulated unshethed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in- charge.
All as per Srl item No. 15 above, but wiring with cable of cross sectional area 4 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 4 Sqmm PVC insulated multistranded copper conductor wire as earth continuity to common earth dolly.
S&F MCB 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408595 / L&T / Havells / Schneider / C&S / ABB
Suppyling, installing, testing and commissioning of factory made outdoor type bus bar chamber having MCCB 4 pole, 415 volts, 63 Amps of suitable size for operation on 415 volts, 3 phase, 4 wire 50Hz, outer shell shall be made out of 3.15mm thick CRCA sheet duly powder coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the 63 Amps aluminium bus bar fixed horizontally in staggred manner minimum length 450mm, 3 phases and neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty DMC insulators duly connected with 63 Amps MCCB including provision for taking out incoming and outgoing cable detacheable plate at bottom for cable entry and making six Nos hole in each bus bar including with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body complete all as specified and directed by Engineer-in-Charge.
Suppyling, installing, testing and commissioning of factory made indoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 2.00mm thick CRCA sheet duly powder coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back suitables to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories :-
Contd/-… item No 19 Incoming (a) 400 Amps aluminium bus bar and Neutral - 01 Set (b) MCCB 250 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 250 420249 / L&T / Havells / Schneider / C&S / ABB Outgoing (a) MCCB 200 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 250 420248 / L&T / Havells / Schneider / C&S / ABB (b) MCCB 63 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 03 No Make - Legrand Cat Part No DPX³ 160 420053 / L&T / Havells / Schneider / C&S / ABB (c) Digital Voltmeter flush type 0-500 Volts square type 96mm x 96mm - 01 No (d) Digital Ampere meter flush type 0-250 Amps square type 96mm x 96mm - 01 No (e) CTs 200/5 Amps - 01 Set (set of three) (f) Internal all links & control cable and indicators - set of three Note :- Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account.
S&F street light pole box of size not less then 300x200x105mm, made of high quality thermo plastic polystyrene, weather proof, dust, jet water proof, chemical, acid corrosion, impact, insulated & shock proof IP 65 for outdoor Installation with internallly embedded gasket (PUR) including MCB SP 6 Amps 01 No along with left side hinge door (notch arrangement not acceptable) & premoulded knockout all sides including back of the base must. The box fitted with 16 sqmm stud type terminal - 04 Nos including Elimex stud type TB 4 Nos complete all as specified and directed by Engineer-in-Charge. Note :- (i) Cost of flat iron clamp is deemed to included in unit rate of this items. Nothing extra shall be paid on this account. (ii) Size of junction box for different mafufacturer may slightly varried from size mentioned in description of item. Contractor has to provide junction box as per cat No mentioned against make of junction box. where cat No is not mentioned against any make, in that case junction box of size mentioned in description has to provide, if exact size of junction box is not available, then next higher size junction box has to be provided. Nothing extra shall be paid on this account.
M&L for painting on steel tubular poles 6 metre long including attachments such as cross arms, bracings, clamps, GI pipes, battery box etc with one coat of aluminium paint after preparation of steel surfaces and black & white strips 30cm each upto 1.5 metre height with synthetic enamel paint from top of PCC foundation block or PCC coping including numbering of poles with synthetic enamel paint (white) in 50mm high letters over 80mmx80mm yellow base complete all as specified and directed by Engineer-in-charge.
S&F PVC insulated stranded copper conductor, 1100 volts grade, 2.5sqmm 3 core size of ISI marked connection from security light to pole box complete all as specified and directed by Engineer-in-Charge.
S&F isolator 40 Amps four pole suitable for 240 Volt AC supply complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 406519 / L&T / Havells / Schneider / C&S / ABB
S&F flush mounting factory made SPN DB 4 way, 240 Volt, Single door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507610 / L&T / Havells / Schneider / C&S / ABB
S&F sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge. Make of DB :- Legrand Cat part No 507811 / L&T / Havells / Schneider / C&S / ABB Make of MCB :- Legrand Cat Part No 408593 / L&T / Havells / Schneider / C&S / ABB
S&F Sub main wiring complete with 2 single core 6 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 6 Sqmm size cable as earth continuity wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F street light bracket made out of 32mm dia GI pipe light grade 1.5m long , bent to shape at 120 degree angle from vertical fixed along pole with and including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts, washers etc. duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
Supply, fixing and testing compact LED solar light fitting of 20 Watt, including high efficeincy solar panel of suitable size and durable 98 wh Lithium for operation of 20W LED solar street light. The complete solar panel including light and battery must be compact complete with body robust corrosion resistant superior finish and without any cracks of through holes made in a single piece by high pressure die cast aluminium alloy. The solar panel must be high efficiency integrated mono crystalline to charge the lithium ion battery and light will be functional for minimum 8-10 hours uninterupted operations. The complete panel must be dust and water proof with minimum IP 65 protection as per IS 10322-1982 (Part-I) with latest amendments and the battery should be protected against overcharge and deep discharge including battery status indicator. The efficienct of LED luminaries shall be 100 lumens per watt and with the function of auto ON/OFF as well as manual. The complete solar panel should have complete fixing accessories / arrangement on existing pole having dia 50-80mm complete all as specified and directed by Engineer-in- charge. Make :- Crompton / Bajaj / Surya / Syska / Philips or equivalent in makes mentioned in Appendix 'A' here-in-after. Note :- (i) To fix the complete solar panel on existing pole if there is any change to be made in existing pole or solar panel, will be dony by the contractor at his own arrangement. Nothing extra shall be paid on this accout. (ii) Any T & P and Ladder wheel required for the work shall be arranged by the Contractor. The rate of this aspect is included in this item and nothing extra shall be paid on this account.
Supply and fixing energy efficient LED street light fitting of 60W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, complete fitting with all accessories and following specifications and all as directed by Engr-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) CRI : Morethan 80 and CCT : 5700 K. (g) IP rating : IP66. (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10 kV (inbuilt + extended) (m) Lens - High Efficiency wide angle lens. (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily) Make :- Syska, Crompton, Havells, Wipro, Philips
Notes for srl Item No 29 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account.
S&F three phase automatic street light switch suitable for 5 KW load complete with Infrared sensor based NATURE SWITCH for automatic switching of street / security lights with three number two pole power contractors 40 Amps (Type - MU40-2P, Cs90119) with coil voltage 220 / 240 V and incoming MCBs single pole - 03 Nos, outgoing MCBs single pole - 03 Nos of rating 32 Amps & circuit wiring with single core multi stranded of size 10 Sqmm. Lighting switch operation should be based on natural light lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility for 4,5,6,........11 & 12 hours. The sensor along with suitable power contactor (S), Incoming -outgoing MCB's should be enclosed in a Rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure with hinged lid confirming to IP66 protection class 2. The circuit should also have provision for manual operation (i.e. sensor By-pass option). The enclosure should be platform mounted and structure (made out of angle iron 40mm x 6mm minimum height 600mm from ground level) must be grouted in PCC (1:2:4) type B-1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm including taking down old unserviceable timer switch complete all as specified and directed by Engineer in charge. Make :- KAKATIYA ENERGY SYSTEM PVT LTD / Bajaj / L&T / Legrand / Siemens
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade top of pipe with funnel & wiremesh, and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed by Engr-in-charge. Notes :- (i) GI wire upto DBs or upto earth test point is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for RCC cover shall be 1 KG.
S&F water storage heater (geyser) of 25 ltr capacity, energy saving 5 star rating complete with fire retardant cable and 3 pin plug 15/16 Amp, including grouting 4 Nos bolts in PCC (1:2:4) block in wall and making good the disturbed surfaces matching with existing including making connection to elerctric supply complete all as specified and directed by the engr-in-charge. Make :- Havells Product code GHWAMJSIV025 (Model Monza Digi) / Racold / Bajaj / Crompton
Supply, installation, testing and commissioning Split Type Air conditioner Electric driven (Single phase) with stand, copper condensor, 1.5 Ton, minimum four Star rating capacity with remote control including complete assecories all as per manufacturer's instructions in all respect as directed by Engineer-in-charge. Note :- Voltage stabilizer of required capacity shall be measured and paid for separeltly in respective item of BOQ.
Supply, installation, testing and commissioning Split Type Air conditioner Electric driven (Single phase) with stand, copper condensor, 2 Ton, minimum four Star rating capacity with remote control including complete assecories all as per manufacturer's instructions in all respect as directed by Engineer-in-charge. Note :- Voltage stabilizer of required capacity shall be measured and paid for separeltly in respective item of BOQ.
Supply, installing & testing Voltage Stabilizer of capacity 5 KVA copper wound for automatic operation , single phase naturally air cooled indoor type & designed for input variation between 170V to 280V output voltage 230 V with accuracy of + 5% complete all as specified and directed by Engineer in charge.
Supplying, laying, jointing, commissioning and testing PVC insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 70 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 36 above but cable of cross sectional area 16 sq mm 4 core
All as per item No 36 above but cable of cross sectional area 25 sq mm 4 core
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account.
All as per item No 44 above but 32mm bore tubing
All as per item No 44 above but 15mm bore tubing -------------------------------------------------------------------------- Note :- A sum of Rs. 314900/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 28 (Schedule of Credit) of Tender documents.
BHADU BUILDERS
MISHRA CONSTRUCTION COMPANY
GURDEEP SINGH AND COMPANY
Gill Construction Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .