Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹45.9 L+₹1.3 L (3.00%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹46.0 L+₹1.5 L (3.38%)Rejected-Finance C O PULAK SAHA MAHAKAL PALLY SURYASEN PARK MAIN GATE SILIGURI 734001 DIST DARJEELING | JALPAIGURI | WEST BENGAL | 734001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹46.9 L+₹2.3 L (5.27%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹47.3 L+₹2.8 L (6.31%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
21 Jun 2023, 6:00 pmClosed
GE SEVOKE ROAD
GE Sevoke Road Post Salugara Dist Jalpaiguri PIN 734008
REPAIR TO LEAKAGE SEEPAGE AT OTM ACCN ZONE B AT SEVOKE MIL STN UNDER GE SEVOKE ROAD
2023_MES_599941_1
8229/SEV OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE SEVOKE ROAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE SEVOKE ROAD
₹88,000
Yes
30 Jun 2023
31 May 2023
23 Jun 2023
31 May 2023
21 Jun 2023
15 Jun 2023
1 Jun 2023 - 10 Jun 2023
Amount
Taking down cement plaster or cement lime plaster on walls /ceiling of any description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris out side MD land including necessary scaffoldings etc complete all as specified and directed
Taking up or down 15 mm bore steel tubing and connections including cleaning for re-fixing or removal complete all as directed.
Taking up or down 20 mm bore steel tubing and connections including cleaning for re-fixing or removal complete all as directed.
Taking up or down 25 mm bore steel tubing and connections including cleaning for re-fixing or removal complete all as directed.
Demolition of brick coba/cement concrete (unreinforced) from existing roof/terrace etc and also removing/taking down of existing water proofing treatment of any thickness in any position including cleaning the surfaces of roof etc with wire brush complete and removing the retreived debris in low lying area, complete all as specified and directed.
Dismantling PVC water tanks from the position of 1000 ltrs capacity complete all as directed.
Dismantling PVC water tanks from the position of 500 ltrs capacity complete all as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises etc complete all as directed.
Dismantling steel sheeting or galvalume aluminium zinc of any gause thickness (plain) (corrugated semicorrugated) in roof coverings etc complete all as directed.
Dismantling wall & ceiling boards ( fiber, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness, including cover fillets complete all as specified and as directed
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as directed.
Demolition of reinforced cement concrete work (RCC water tank) of any description and in any position not otherwise specifically provided for all as directed
M&L for brick work with sub class 'B' bricks using old size bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and directed
M&L for brick work with sub class "B" bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed
M&L for 20 mm thick rendering in CM 1:4 in two layers of 10mm each using water proofing compound in top layer only including finishing the surface even and fair(WPC shall be measured and paid seperately) complete all as specified and as directed.
M&L for 15mm thick rendering on other than fair faces of brick or concrete surfaces in CM 1:6 finshed even and smooth without using extra cement complete all as specified and directed
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer over 1 mm thick wall putty complete all as specified and directed. .
Supply only water proofing compound (integral) complete all as specified and directed.
S&F 15 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as specified and directed.
S&F 20 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as specified and directed.
S&F 25 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as specified and directed.
Re-fixing only 15 mm bore tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as directed.
Re-fixing only 20 mm bore tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as directed.
Re-fixing only 25 mm bore tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as directed.
M&L for applying two coats of Acrylic emulsion paint (first quality) over coat of exterior damp proof primer including preparation of new plastered surfaces complete all as specified and directed.
Material and labour for precast RCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) as in slabs, haunching, landings, etc. including formwork complete all as specified and directed
Material and labour for TMT bar 5mm dia and over and including 10mm dia as in stirrups, main bars, spacer bars and binders complete all as specified and directed
Material and labour for cement concrete type D2, 1:4:8, using 40 mm graded aggregate in basement for foundations to PVC water tank, filling etc complete all as specified and as directed.
M&L for 25 mm thick PCC (1:2:4) type B-0, using 12.5mm graded stone aggregate as in levelling course over RCC roof surface to achieve required slope including making rounded or chamfered on edges mixed with WPC @2% by weight of cement, complete all as specified and directed. Note : WPC shall be measured and paid separately as supply only.
M&L for 15mm thick rendering in CM (1:4) over RCC roof surface to receive roof treatment finished even and smooth without using extra cement mixed with water proofing compound as per manufacturers instruction (WPC shall be measured and paid separately).
M & L for surface preparation including cleaning the surface , treating of construction joints , filling of honey combs with polymer modified mortar (cement:sand: approved polymer(asian/beger) for filling cracks up to 3mm use approved crack seal, bigger cracks, damaged potions and hollow areas must be repaired with polymer modified cement mortars complete as specified and as directed.
Material and labour for angle fillets all around the periphery of the wall with polymer modified mortar using approved polymer of make Asian/Beger/Dr Fixit.
M&L for applying water proofing treatment to slab area with damp proof ultra, fiber reinforced elastomeric liquid applied water proofing membrane of apporoved make(Asian/Berger/Dr Fixit) . It is formulated with PU hybrid polymers and reinforcing acrylic fibers. Upon curing, it forms a thick, seamless, durable membrane thus offering ultimate water proofing. First do the self priming of smart care damp proof ultra of approved make after completing all necessary surface preparation, coving using approved smart care repair polymer, water pond test, etc complete as per manufacturers specifications and application methodology. The same coating shall be applied in two coats with 4-6 hrs intervals between the coats. Ensure that the product is applied at least 6 inches inside the drain pipe. The coating shall have a 350%-400%elongation with tensile strength of 2.9 Mpa and must be extended up to 300 mm over the slab area and apply parapet to parapet to envelop the entire biulding. Effectively bridges cracks up to 2.5 mm at 650 microns and provides surface temperature reduction up to 10 degree C. Complete all as specified and directed as per manufacturers instruction and submit roof water proofing warranty certificate of 8 years from the manufacturer.
Treatment of sunken floor slab compraises of the following specifications and all as specified.:-
(i) M&L for cleaning the sunken/ lowered portion of RCC slab surface (including vertical total depth plus skirting height ) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely . 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope including 50mm PVC pipe and cutting holes in bricks or RCC wall for spout.
(ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with integral water proofing compound @3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/ seepage is noticed , nozzles shall be fixed and grouting carried out (WPC shall be measured and paid separately )
(iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty
(iv) After drying putty , wash the slab and sides of sunken portion with water and make it clear and clean.
(v) M&L for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level +100mm height . The thickness of two layer shall be 1mm . When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.
(vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per menufacturer's specification including rounding of corners and junctions sloping towards spout ( WPC Shall be measured & paid separately)
Note :- Test the water proofed area (ponding test ) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE . Test shall be done in presence pf reps of PMG and record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing in inclued in the rates quoted above.
(vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint (Black Japan)
(viii) Two nos 50mm bore GI medium grade 600mm long spout shall be provided through external wall to drain out accumulated water.
Material and labour for surface preparation including cleaning the surface , treating of construction joints , filling of honey combs with polymer modified mortar (cement:sand: approved polymer(asian/beger) for filling cracks up to 3mm use approved crack seal, bigger cracks, damaged potions and hollow areas must be repaired with polymer modified cement mortars complete as specified and as directed.
Material and labour for Roof treatment by application of non toxic polyurethane modified acrylic based single component (P U Roof Coat) solvent free, cold applied polyurethane modified elastomeric waterprooofing membrane with excellent UV resistant capasity as per ASTM D6083 [a water based 100% acrylic elastomeric emulsion polymer latex coating used as protective coating for roofs] after preparing the surface by cleaning and repairing the roof cracks by cement & sand mortar (1:4), with antishrinkage mortar (to be paid separately) if any, apply two coats along with a priming coat (tow coats of P U Roof Coat and one coat of primer coat compatible with main product as per manufactures specification) and reinforced with 20 gsm Geotextile Fleece, including the cost of primer coat and base preparation, tools & palnts complete as per manufacturer instructions. Manufacturer:- ASIAN/ BERGER/ SHALIMAR. Note:- (i) Application of roof treatment shall be done by the authorized applicator of manufacturer as approved by GE. (ii) Contractor shall be obtained the Gaurantee from the manufacturer for 10 years and submit to the department alongwith the Garuntee as specified in CA.
Supply and applying concrete surface with single component, fibre reinforced shrinkage compensated, polymer modified structural grade repair mortar at a thickness of 40mm. The repair mortar should have a compressive strength 45 N/mm2, flexture strength 7 N/mm2 and tensile strength 2.5 N/mm2 at 28 days and curing the treated surface with polymer based curing agent having moisture retention : <0.55 kg/ sqm as per ASTM C156 Drying time 3 hrs @ 23 degrees. (Make :- FOSROC or Equivalent)
Providing and laying micro concrete up to the required thickness (avg 60mm) as per the drawing by consultant on the designated area to the prepared slurry tight shutteing with proper shear conector and bonding agent where ever necessary, The fluid micro-concrete repair material shall be single component, cement based, micro-concrete to which only the site-addition of clean water (and approved graded coarse aggregates where specified) shall be premitted. The micro concrete shall contain no metallic aggregateds, or chlorides and shall be shrinkage compensated in the plastic state. The micro concrete in the flow able consistency should achieve a compressive strength of 50 N/mm2 after 28 days at 30 C as per BS 4551-80. The unrestrained expansion shall be between 1-4% as per ASTM C827-1987. Again as per BS 4551-80 the flexural strength shall not be less than 5 N/mm@ @ 28 day. The micro concrete shall have a co efficient of thermal expansion 10-12 x 10-6/C & Thermal conductivity 1.5 W/m C the mixed density of micro concrete shall exceed 2100-2200 Kg/M3 at 21C. (Formwork needs to be ready as per RCC Column/Beam before application of epoxy bonding agent and placing micro concrete).
Disconnecting existing tanks 500 ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required connecting and re-fixing in position incl cleaning.
Disconnecting existing tanks 1000 ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required connecting and re-fixing in position.
S&F rotational moulded polyethylene water storage tanks, triple layered(ISI marked) of 500 ltrs capacity(cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I, including provision of necessary fittings for connection the overflow, drain out, inlet and outlet pipes, complete all as specified and as directed.
S&F rotational moulded polyethylene water storage tanks, triple layered(ISI marked) of 1000 ltrs capacity(cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I, including provision of necessary fittings for connection the overflow, drain out, inlet and outlet pipes, complete all as specified and as directed.
S&F Ball brass valves of size 25 mm bore high pressure, the polythene float and fly nut, screwed for iron pipe or brass frame etc, complete al as specified and directed.
M&L for non skid coloured ceramic tiles of 7 to 8 mm thick (square/rectangular) area exceeding 0.11sqm but not exceeding 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles over and including 15 mm thick screed bed or beding layer of CM 1:6 for laying of floor finises complete all as specified and as directed
M&L for glazed coloured ceramic tiles of size 450x350x 7mm thickness in vertical surfaces set and jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles on wall over and including 10 mm thick rendering as backing layer in CM 1:4 complete all as specified and as directed.
S&F in repair for PVC (SWR) floor trap/nahani trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F in repairs vitreous china EWC white with 'P' or 'S' trap front or back inlet any pattern excluding flushing cistern & flush pipe but including plastic water closet seat black closed pattern with flat bottom and cover and hinging device complete all as specified and directed.
S & F in repairs flushing cistern, 10 Ltrs. Capacity, PVC valveless, syphonic action type with dual flushing system, low level,white with inlet, ball valve,float and handle including brackets, flush pipe of polyethylene of low or high density or PVC, 32mm dia, complete all as specified and directed.
S&F PVC connection pipe 15 mm dia, 450 mm long with PTMT nut complete all as specified and as directed
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed
S&F in repair sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed
S&F soap dish Chromium plated complete as specified and directed.
Supply and fixing toilet paper holder Chromium plated as per specified and directed
S&F in repairs brass chromium plated, shower rose, 125mm size, complete all as specified and directed.
S&F towel rail 600mm long of PTMT (min weight 190 grams) fixed with and incl chromium plated brass screws and wooden / plastic cleats, complete all as specified and directed.
S&F Stop cock/angle cock, cast copper alloy chromium plated, screwed down, high pressure with crutch or butterfly handle, fancy type chromium plate with long shank and cup complete all as specified and directed.
S&F 15mm bore bib tap cast copper alloy with crutch or butterfly handle, fancy type, chromium plated, screwed iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair of CP brass wall mixture 3 in 1 system with provision forhead shower with long bend pipes and wall flangs with 125mm size chromium plated shower rose with swivel joint and matching CP arm complete all as specified and directed.
S&F pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering/clading to wall, fixed with self taping screws complete all as specified and directed..
S&F pre painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering/clading to wall, fixed with self taping screws complete all as specified and directed.
S & F Mild steel work in framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunken for screw, including bending and welding angles as necessary gusset plates; riving etc n'exc 10 Kg each brackets conforming to Fe-290 Gde-165 including taking down old framed works complete all as specified and directed. .
S & F Framed work as in tubular posts roof trusses, purlines, rafters etc made of tubes (square circular oval or any other shape or section as directed) including all necessary fittings, nut bolts, threading or welding etc as required f including taking down old unserviceable framed complete all as specified and directed.
M&L for applying two coat of synthetic enamel paint on newly steel surfaces exceeding 10 cm in width or girth over one coat of red oxide primer after preparation of surface complete all specified and directed
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittinges, heads, shoes, bends, swan-necks etc including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories)
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F 110 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as specified and directed.
S & F 110 mm bore PVC (SWR) branch piece double (Double `Y') equal or unequal with access door complete all as specified and directed.
S & F 110 mm bore PVC (SWR) Vent cowl complete all as specified and directed
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F 75 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as specified and directed.
S & F 75 mm bore PVC (SWR) branch piece double (Double `Y') equal or unequal with access door complete all as specified and directed.
S & F 75 mm bore PVC (SWR) Vent Cowl complete all as specified & directed
Supply and fixing 605X605mm anodised aluminium snap grid frame work for false ceiling including 2.5mm dia mild steel wire galvanized class 3, @ 60cm centre to entre and fixed to steel or wooden member including 4mm thick decorative type non asbestos fibre cement board fixed or laid/ inserted to aluminium frame work as in ceiling complete all as specified and directed. Note:- The size of aluminium main and croos tee shall be 40mm x25mm x2mm and size of angle shall be 25mm x 25mm x 2mm)
B K SINGH
MARWA CONSTRUCTION
LIBERAL ENGINEER CONSTRUCTION
SHRI JAYANTA GHOSH
M/S DUTTA & DAS ENGINEERING CO.
M/S S.B. CONSTRUCTION
M/S L N CHOWDHURY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .