Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 CrAccepted-AOC | ₹27.6 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹27.7 CrRejected-Finance | ₹27.7 Cr | L2 | Rejected-Finance Other than Lowest |
| 3 | L3₹28.2 CrRejected-Finance | ₹28.2 Cr | L3 | Rejected-Finance Other than Lowest |
| 4 | L4₹29.0 CrRejected-Finance | ₹29.0 Cr | L4 | Rejected-Finance Other than Lowest |
| 5 | L5₹30.4 CrRejected-Finance GYAMDU HOUSE OLD ROAD SHANAM LEH LADHAKH UT PIN 194101 | LEH LADAKH | LADAKH | 194101 | ₹30.4 Cr | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹29.3 Cr
EMD Value
₹15 L
Closing Date
12 Jul 2023, 6:00 pmClosed
Chief Engineer Leh
HQ CE Leh Zone c/o56 APO
PROVN OF OTM ACCN FOR LADAKH SCOUTS BN AT KARU (PHASE - IV)
2023_MES_572702_4
180075
Open Tender
Civil Works
1095 days
LEH
PLEASE REFER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹3,000
GE (I) (P) NO. 2 LEH
₹15 L
Yes
16 Oct 2023
27 May 2023
20 Jul 2023
27 May 2023
12 Jul 2023
23 Jun 2023
27 May 2023 - 7 Jun 2023
Amount
NOTE : Schedule ‘A’ Part - I to Part - XII are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Total amount of Sch 'A' Part - I (Buildings)
Total amount of Sch ‘A’ Part - II (Internal Electrification)
Total amount of Sch ‘A’ Part - III (Internal Water Supply)
Total amount of Sch ‘A’ Part - IV (External Electric Supply)
Total amount of Sch ‘A’ Part - V (External Water Supply)
Total amount of Sch 'A' Part-VI (Sewage Disposal)
Total amount of Sch ‘A’ Part - VII (Road, Path, Culvert and hard standing)
Total amount of Sch ‘A’ Part - VIII (Protective Work)
Total amount of Sch ‘A’ Part - IX (Fencing, Gate and Compound Wall)
Total amount of Sch ‘A’ Part - X (Earthwork and Site Clearance)
Total amount of Sch ‘A’ Part - XI (Demolition)
Total amount of Sch ‘A’ Part - XII (Hot Water Supply)
SCH 'A PART - XIII (CENTRAL HEATING SYSTEM) Note 1: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 5 signifies this fact only. Note 2: Rates under this schedule are deemed to be inclusive of all the allied items, Civil or E/M, required for completion and comissioning of the plant. Hence, nothing extra shall be paid. Please refer uploaded consultancy drawings before quoting.
Oil Fired Hot Water Generator : Supply, Installation, Testing & Commissioning of Oil Fired Glycol based Hot water generator of cap 1 Lac Kcal/Hr using HSD oil complete with combustion chamber and equipment automatic monoblock burner assembly, fire tubes, control panel with sequence controller, photo cell for flame failure, HT transfer electrodes, blower assembly, electric Panel, mounting frame, pressure gauges at inlet and outlet suitable for operation on 50 Hz, single phase, 230 volts AC supply. The Burner should comply as per ISO or equivalent standard. Inlet temp of fluid should be as per site requirement and maximum outlet temp 90°C. The saftey valves for the Boiler are to be included in price.
(a) All neccessary accessories required for the proper fucntioning of Hot Water Genearator are included in price. (b) The prices should include lifting, shifting and positioning of units at Site. (c) Hot Water Genearator installation to be done as per Manufacturer's recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulation etc as recommended by Manufacturer for the Ambient Temperature of Site. Installation of Hot Water Genearator is included in quoted price which includes the Civil Struture, Mechanical Structure etc as recommended by Manufacturer.
Make: Make of Boiler: Riello-- RTQ Series/Thermax-AMW Series/Ecoflam/Rapid Cool-RTC Series or Equivalent Make of Burner: Riello/ Ecoflam Note:- In 02 Nos working and 01 No standby configuration.
Oil Fired Hot Water Generator : All as per srl item No. 2.01 and 2.02 above but for Oil Fired Glycol based Hot water generator of cap 8 Lac Kcal/Hr. Make: Make of Boiler: Riello-- RTQ Series/Thermax-AMW Series/Ecoflam/Rapid Cool-RTC Series or Equivalent Make of Burner: Riello/ Ecoflam Note:- In 02 Nos working and 01 No standby configuration.
FLUE GAS EXHAUST PIPE: Supply, Installation, Testing & Commissioning of MS Flue Gas Exhaust Pipe as per site condition with header made out of 3 mm thick MS sheet, minimum 1.2 m above the highest point of the plant room and including connection from HOT Water generator to main vertical exhaust pipe fabricated from 3 mm MS sheet to be connected to common exhaust pipe header from 3 mm of suitable Diameter. The Hot water generator's shall be connected to a independent flue gas exhaut pipe of suitable size and as per manufacturers guide lines. The portion of the flue gas exhaust pipe in side the building shall be insulated with 25 mm Fiber Glass Insulation wool of 24 kg/cum with GI cladding of 26 gauge. Flue gas exhaust
pipe (item shall be complete with mounting/fixing arrangement) complete as per specified and recommandation of OEM in Consultantion with Engineer - In - Charge. (a) Flue gas exhaust pipe as per recommendation of OEM and site condition with Header for Pocket-1 CHS plant Room Note:- Pl ref drawings for the same.
FLUE GAS EXHAUST PIPE: All as per srl item No. 2.04 above but for Flue gas exhaust pipe as per recommendation of OEM and site condition with Header for Pocket-2 CHS plant Room Note:- Pl ref drawings for the same.
GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, erection, testing and commissioning of Variable speed Hot water horizontal/ vertical, in line, long/ short coupled centrifugal pump.The pump should be BMS compatible and shall be capable of delivering capacity as mentioned below, complete with TEFC induction motor with class ‘F’ insulation to operate on 415±10% volts, 3 phase, 50 Hz AC supply for each pump. The pump motor shall be of IE-3 class efficiency. Each pump shall have CI body, Bronze impeller, spacer coupling and coupling guard, The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to +120 Degree Celcius. Vendor shall provide antivibration arrangement for pumps . The scope also shall include the following :- (a) Electrical by pass starter for pump set. (b) 25 mm thick polyvinyl nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.
(c) 3 Nos. - 150 mm dia type pressure gauges (d) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (e) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation). (f) Capacity and pump head not less than flow 60 USGPM , Head 25 mtr for pocket - 1 CHS each including the triple duct valve and End Suction guide. Make of Pump: Armstrong ( Model No. 4380-5-150 Series) / Xylem /Grundfoss/Wilo. Note : Out of total quantity of 3 nos, 2nos. shall be working and 1 no. shall be stand by.
All as per item No. 2.08 to 2.09 above but for capacity and pump head not less than flow 380 USGPM, head 35mtr for pocket - 2 CHS . Note : Out of total quantity of 3 nos, 2nos. shall be working and 1 no. shall be stand by.
EXPANSION TANK and Pressurisation Unit: Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume of Glycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter and interconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging
arrangement, etc.with Pressure Transmitter and interconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. The tank connection's should be as per OEM recommendations and 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank. The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (with lates Revision) and Rated at PN 16 and ASME Stamped.
The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system. The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panel IP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U value Insulating Material and cladded with aluminium Sheet (20G).
(a) Expansion Tank of 400 Lts capacity for Pocket-1
(b) Expansion Tank of 2000 Lts capacity for Pocket-2
(c) PRESSURIZATION UNIT: for Pump Set - 03 Nos (Ref. item No. 2.11 to 2.13 above) with Control Panel and accessories for Pocket-1. Makes: Armstrong, Xylem( Model: B-500 125PSI and GS-2), Grundfoss, Wilo, Anergy Instruments Pvt ltd
(d) PRESSURIZATION UNIT: for Pump Set - 03 Nos (Ref. item No. 2.11 to 2.13 above) with Control Panel and accessories for Pocket-2. Makes: Armstrong, Xylem( Model: B-500 125PSI and GS-2), Grundfoss, Wilo, Anergy Instruments Pvt ltd
Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 550 litres for Pocket-1 complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of transfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Make up Water tank as described above should be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G).
Make Up TANK: All as per srl item No 2.14 above but for make up tank of capacity 2000 Ltrs for Pocket-2.
DAY OIL STORAGE TANK/ DIESEL TANK: Supply, installation, testing and commissioning of Diesel tank, Rectangular/Circular shape of 4 mm thick MS sheet (IS 2062), of capacity of 550 litres for Pocket-1 complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, keep tank base at minimum 1000 mm above FFL service platform shall be provided as per recommendatios of OEM. The tank shall be provided with remote indication of levels provided with level switches for on-off operation of transfer pump. Extra high level and Extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
DAY OIL STORAGE TANK/ DIESEL TANK: All as per srl item No- 2.16 above but for storage tank of capacity 2000 Ltrs for Pocket-2.
DIESEL CIRCULATING PUMP: Supply, Erection, Testing and Commissioning of Transfer pumps for the capacity of 5 LPM, 5 meter head for Diesel Oil transfer with base frame foundation, bolts coupling coupling guard,TEFC, (OEM design HP for the required Flow and Head ) and other accessories for proper function of the pump. Makes: Armstrong , Xylem , Grundfoss (Model: UPS25-60), Wilo / MES approved Makes.
Supply, Installation, Testing and Commissioning of Ceiling Suspended Fan Coil Unit complete with GI casing with bottom return Air Plenum (5mm PE insulation) or as per site requirement, Filter box with 8mm Nylon Filter, 3 Row Deep cooling coil with copper tube diameter is 9.52 mm and thickness 0.33 mm with hydrophilic Aluminium fins. An air vent in the coil must be provided. Complete coil must be designed for standard working pressure is 1.6 MPa (16bar) and the test pressure is 3.3MPa (33bar). Unit to be provided with SS drain pan with 7mm PE insulation and +200 mm extended. Direct driven fan (three speed) motor, operated on 230 volts, single phase, 50Hz, AC supply. Unit to be provided with electronic Thermostat having LCD and touch button. It has to based on microprocessor operations which can realize intelligent control of room temperature.
The Capacity calculation sheet for Heating application of unit should be in Line with ASHRAE/ Eurovent Standard for Fan Coil. The Cut outs to be made in ceiling as per the Machine for the Servicing purpose.Trape Door should be included in the price. Unit to be installed with Ball Valve and Auto Air vent. The desired U trap should be given as per the site Requirement. Makes for FCU: Daikin (FWW Series), Midea(MKT Series), Trane,York,Carrier,Sinko Makes for Remote/Thermostat : Danfoss,Siemens, Honeywell, Belimo/ Ballorex/ JCI The Minimum Capacity should be as follows:
(a) 1.5 KW (External Static Pressure: 50 Pa)
(b) 3 KW (External Static Pressure: 60 Pa)
(c) 4 KW (External Static Pressure: 80 Pa)
(d) 5 KW (External Static Pressure: 80 Pa)
(e) 8 KW (External Static Pressure: 80 Pa)
(f) 10 KW (External Static Pressure: 80 Pa)
(g) 12 KW (External Static Pressure: 80 Pa)
(h) 14 KW (External Static Pressure: 80 Pa)
(j) 18 KW (External Static Pressure: 80 Pa)
(k) 20 KW (External Static Pressure: 80 Pa)
Supplying, fixing, testing and commissioning of Hot water Glycol pipes (Pre-Insulated) of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of -50 Degree Celcius to 120 Degreec Celcius. Note:- The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Makes: Zeco/Seven Star/Lloyd/Parma Pipe or equivalent
Inside Building
(a) 150 mm bore with 50 mm PUF thicknes and 24 Gauge Aluminium Cladding
(b) 125 mm bore with 50 mm PUF thicknes and 24 Gauge Aluminium Cladding
(c) 100 mm bore with 50 mm PUF thicknes and 24 Gauge Aluminium Cladding
(d) 80 mm bore with 50 mm PUF thicknes and 24 Gauge Aluminium Cladding
(e) 65 mm bore with 36 mm PUF thicknes and 24 Gauge Aluminium Cladding
(f) 50 mm bore with 36 mm PUF thicknes and 24 Gauge Aluminium Cladding
(h) 40 mm bore with 36 mm PUF thicknes and 24 Gauge Aluminium Cladding
(j) 32 mm bore with 36 mm PUF thicknes and 24 Gauge Aluminium Cladding
(k) 25 mm bore with 36 mm PUF thicknes and 24 Gauge Aluminium Cladding
(l) 20 mm bore with 36 mm PUF thicknes and 24 Gauge Aluminium Cladding
Buried :
(a) 150 mm bore with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge
(b) 100 mm bore with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge
(c) 80 mm bore with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge
(d) 65 mm bore with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge
(e) 50 mm bore with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge
Exposed to Ambient :
(a) 150 mm bore with 150 mm PUF thicknes and 24 Gauge Aluminium Cladding.
(b) 100 mm bore with 150 mm PUF thicknes and 24 Gauge Aluminium Cladding.
(c) 80 mm bore with 150 mm PUF thicknes and 24 Gauge Aluminium Cladding.
(d) 65 mm bore with 150 mm PUF thicknes and 24 Gauge Aluminium Cladding.
(e) 50 mm bore with 150 mm PUF thicknes and 24 Gauge Aluminium Cladding.
(f) 40 mm bore with 150 mm PUF thicknes and 24 Gauge Aluminium Cladding.
Supply,Installation, Testing and commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping complete with fittings(elbows,tees, reducers,sockets,u trap etc.) supports, jointing insulated with XLPE class O tubular insulation and any other item required to make the system complete. Nominal diameters of pipe in mm as indicated below:-
(a) 25 mm bore pipe, Insulation thickness-19 mm
(b) 32 mm bore pipe, Insulation thickness - 19 mm
(c) 40 mm bore pipe, Insulation thickness - 19 mm
Cable/ Pipe Tray Supplying and installing perforated powder coated M.S. cable trays of size 150 mm width X 50 mm depth X 1.6 mm thickness with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/ Ground/ wall with M.S. suspenders including bolts & nuts, painting suspenders etc. as required
Duct and Grills :
Supply, Installation, Testing Balancing & Commissioning of G.S.S rectangular/round ducting including plenum as reuired as per IS 655 - 2006 complete with gaskets, elbows, splitters, vanes, supports adjustable dampers, etc. as per approved drawings (Factory Fabricated) as recommended by OEM.The price shall include necessary scaffolding required for working at required height thikness of sheet 24 Gauge, hot dipped Galvanised with 120GSM Zinc coating.
Supply and fixing of acoustic lining of supply air duct and plenum with 15 mm thick Supply and Application of Acoustic Insulation with Engineered Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method A and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supply and fixing of Flexible connection Duct.
Valves
Supplying, fixing, testing and commissioning of following diameter valves (PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified:-
(a) 150 mm dia. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.
(b) 125 mm dia. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.
(c) 100 mm dia. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.
(d) 80 mm dia. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.
(e) 65 mm dia. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.
(f) 50 mm dia. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.
(g) 40 mm dia. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets. (Toilet area) Makes for butterfly valves :Audco/ C&R/ Adverse
(a) 125 mm Ø . Y - STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer for hot water circulation including Insulation thickness of valves should be equal to the Insulation of PUF and AllGI Cladding of as directed by Engr-in-Charge pipe section as specified. Makes : Audco/ C&R/ Adverse/ Anergy
(b) 50 mm Ø . Y - STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer for hot water circulation including Insulation thickness of valves should be equal to the Insulation of PUF and AllGI Cladding of as directed by Engr-in-Charge pipe section as specified. Makes : Audco/ C&R/ Adverse/ Anergy
(a) 125 mm Ø . NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for hot water circulation including Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified. Makes : Audco/C&R/Adverse/Anergy
(b) 50 mm Ø . NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for hot water circulation including Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified. Makes : Audco/ C&R/ Adverse/ Anergy
(g) Automatic Air Purge Valves of size minimum 20mm for hot water circulation header as specified and required by Engineer In Charge. Makes : Audco/ C&R/ Adverse/ Anergy
(h) Air Separator 125 mm dia.
(h) Air Separator 50 mm dia.
(j) SITC of water pressure gauge (100 mm Ø) bourdon type with brass ball valve of 3/8" Ø and SS tubing, socket. Range (0-50) / (0-100) as required at site or directed by Engineer In Charge.
(k) SITC of Mercury in glass industrial thermometer in SS-304 casing with 0.5 degree C least count, range 0-50 degree C. Brass oil filled thermowell of 1/2" size as required by Engineer In Charge.
Electrical distribution Panel :- Supply, installation, commissioning and testing of factory made, CPRI approved LT panel for Pocket -1 CHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :-
INCOMERS (a) Bus Bar TPN Copper extensible type main bus bars of minimum of 200 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars of suitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 50kA . (b) MCCB 125 Amps, 415 Volt, 36 KA, 4 Pole, thermal magnetic release - 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers) Make: Legrand/Schenider/Simens (c) Change over switch 125 Amps, 415 Volts, 4 pole (on load). Make: Legrand/Schenider/Havells
OUTGOINGS (d) MCB 10 Amp, 10KA, SPN - 02 No (Offr block No.1 and Offr block No.2 ) (e) MCB 20 Amp, 10KA, TPN - 03 Nos for Pumps (f) MCB 5/6 Amp, 10KA, TPN EL - 05 No for Pressurization PUMPs /Diesel Pump/ Boiler pump (g) MCB 63 Amp, 10KA, DP - 01 No for Bldg load. Makes of MCBs: Legrand/Schenider/Simens (h) LED Phase indication lamps (01 Set) with 2Amp back up MCB, Breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set
(j) Digital Ammeter with in built ASS, metering C.T.s "CAST RESIN" type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set. (k) Digital Voltmeter with in built VSS, with 2Amp suitable upto 500 Volts Back up MCB. (l) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge. Note : Contractor will submit the drawing of panel to GE before execution for approval. Note : Contractor will submit the drawing of panel to GE for approval before execution.
Electrical distribution Panel :- Supply, installation, commissioning and testing of factory made, CPRI approved LT panel for Pocket -2 CHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :-
INCOMERS (a) Bus Bar TPN Copper extensible type main bus bars of minimum of 400 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars of suitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 50kA . (b) MCCB 250 Amps, 415 Volt, 36 KA, 4 Pole, thermal magnetic release - 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers. Make: Legrand/Schenider/Simens (c) Change over switch 250 Amps, 415 Volts, 4 pole (on load). Make: Legrand/Schenider/Havells
OUTGOINGS (d) MCB 63 Amp, 10KA, SPN - 03 No (Bldg,FCU for OR block 1 and block 2) (e) MCB 16 Amp, 10KA, SPN - 02 No (JCOs block 2 & 3) (f) MCB 10 Amp, 10KA, SPN - 03 No (JCOs block 1, JCOs Mess, ORs CH&DH) (g) MCB 40 Amp, 10KA, TPN - 03 Nos for Pumps (h) MCB 5/6 Amp, 10KA, TPN EL - 02 No for Pressurization PUMPs /Diesel Pump (j) MCB 10 Amp, 10KA, TPN EL - 02 No for Boiler Pump (k) MCB 10 Amp, 10KA, TPN EL - 02 No for Boiler Pump (l) MCB 63 Amp, 10KA, DP - 01 No for Bldg load. Makes of MCBs: Legrand/Schenider/Simens
(m) LED Phase indication lamps (01 Set) with 2Amp back up MCB, Breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set (n) Digital Ammeter with in built ASS, metering C.T.s "CAST RESIN" type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set. (o) Digital Voltmeter with in built VSS, with 2Amp suitable upto 500 Volts Back up MCB. (p) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge. Note : Contractor will submit the drawing of panel to GE before execution for approval.
L.T. CABLES
Supply & Laying/ fixing of following size LT XLPE insulated, screened, PVC sheathed Copper conductor unarmoured as required of 1.1 KV grade complete as required.(ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray) :-
(a) 4 Core x 10 Sqmm. (Pocket-2 Pump)
(b) 4 Core x 6 Sqmm (Pocket-1 Pump)
(c) 2 Single core x 2.5 sq.mm. (FCU)
Supply and fixing rubber matting conforming to IS-15652-2006 complete as required. of size 2m x 1m x 25 mm thick complete all as specified and directed.
Glycol - Water Solution M&L for Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed. NOTE:- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol water mixture ratio shall be 55:45 and freezing temperature shall be - 45 Degree Celcius for Pocket - 1 and Pocket - 2
Bulk Storage Tank :- Supply, installation, testing and connecting with the system and commissioning of horizontal cylindrical oil storage tank made out of mild steel design, temperature 30°C and design pressure atmospheric + static head of liquid, tank shall be complete with manhole, lifting lugs, earthing lugs, vent pipe, dip stick, inlet, outlet connections complete all as spfd and directed. Storage capacity (Normal 10 KL, gross cap not exceeding 10000L) shell thickness-4mm, end plate thickness 6mm.
EARTHING & MISCELLANEOUS ITEM Earthing complete with GI earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge.
SCH 'A PART - XIV (DG SET) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 5 signifies this fact only
Supply, installation, testing and commissioning of diesel engine driven genrating set of capacity 82.5 KVA, 415 Volts, 0.8 power factor, mounted on common base frame with flexible coupling, 1500 RPM at NTP with silencer pipe protected with asbestos rope independently supported from engine to outside of power house upto 1.00 metre, AVM pads, PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) foundation as per manufacturer's design, cold starting kit, battery start with suitable cables for connecting from DG Set to panel board, with AMF Panel complete with relay and switch gears for automatic starting on main failure. The DG set shall be capable of operating in temp range of (-) 35° to (+) 35° C) at an altitude of 4200 mtr above mean sea level (MSL) complete with and including the following:- (For CHS of Pocket-I)
(A) Prime Mover:- Diesel engine of suitable capacity coolant cooled type (use min DAFC 50%), Radiator mounted, closed circuit as per IS system having rated speed 1500 RPM. Engine shall be equipped with all standard fitting as per manufacturer's recommendations and mounted on common base frame with following accessories/fittings:-
(i) Fly wheel with housing. (ii) Air Cleaner - Oil bath type (iii) Corrosion resistors. (iv) Fuel filter, Oil filter (v) FIP system including pump injectors, solenold controls, nozzled governors etc. (vi) Oil cooler and oil pumps as applicable. (vii) Radiators fan belt. (viii) Water pump assembly including thermostat etc. (ix) Silencer with buffers or expansion joints, tail piece duly insulated with asbestos lagging and sufficiently extended to carry exhaust outside the power house building/room. (x) Engine protection device against low lubricant oil pressure, high oil temperature, over speeding of engine.
(xi) Battery charging ammeter. (xIi) Ignition key and starting with push button switch. (xiII) Eletronic governor controlling. (xIv) Cold starting kit fitting with engine. (xv) Anti vibration pads of required numbers. (xvi)12 Volts DC electrical starting equipment comprising of the following :- (a) 01 No 12 Volts 180 AH battery of make Exide/Amaron/Luminous maintenance free including of iron frame as directed at site by Engr-in-Charge. (b) Battery charging altemator with in built regulator. (c) Self Starter 12 V capacity. (d) Battery leads (copper cables) of suitable size with brass thembles and terminals. Make : Kirloskar/ Cummins/ Greaves Cotton
(B) ALTERNATOR :- Alternator rating 82.5 KVA, 3 Phase, 50 cycles 415 volt, 4 wire supply at NTP 0.8 power factor running @ 1500 RPM, self regulated, mounted on a strong fabricated steel frame suitable for mounting on a permanent foundation to be coupled with above engine. The alternator shall be Relivent IS alongwith self regulated AVR system. Make : Kirloskar/ Cummins/ Crompton Greaves
(C) GENERATOR MONITORING SYSTEM : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lubrication oil pressure, high coolant temp (alarm and shutdown). (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm and shutdown). (iv) Data logging : Engine hours, control hours, engine start and recent fault codes. (v) Certifications : Certificates to meet the requirements of relevant ISO, CE, CSA and other equivalent.
(D) ACOUSTIC ENCLOSURE : Enclosure is free standing floor mounted factory built and moduler in construction to facilitate easy assembly at work site will be drop over housing type. It will consist of acoustically treated panel housed in sheets steel will provide easy access for maintenance, repairs and operation be designed to meet MoEF/CPCB norms. The enclosure is custom built to suit conditions, with the following features. (i) Custom built product for various equipments, which ensure the optimum performance. (ii) Rugged in constuructions maintenance free and modular designs which facilitate easy at site. (iii) 16 SWG (1.6 mm) thick CRCA sheets to be used for enclosure panel to ensure longer life against weathering action. High quality fire retardent acoustic insulation material to be used for maximum sound absorption. Acoustic layers are supported by perforted sheets.
(iv) Sheet metal components of the enclouser should undergo various stages of surface treatment prior to painting which leads to be better life of the enclouser against weathering action. (v) Special paint treatment with pure polyester powder/ epoxy to be provided for better weather resistance. (vi) Well designed ventilation system to be provided to pump up the heat in the chamber efficiently. (vii) For effective acoustic/ weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used. (viii) Working space is to be provided around the equipment for easy maintenance/ repairs. (ix) Necessary cut out provision for entry and exit of fuel lines cable to be incorporated in the enclosure as per the requirement.
(x) A see through transparent window (glass or acrylic) in front of engine panel to provide for monitering the operation. (xi) Ducting if required, bellows, mechanical hardware like locks, hinges, fasteners etc to be provided. (xii) Deliverables 75 dBA @ 1 mtr at full load under free field conditions. The temp inside the enclosure will be as per manufacturer's recommendations above ambient temp. (xiii) The enclosure should provided with bulk head light fitting for inside illumination. (xiv) The battery should place inside the enclosure beside DG set on a suitable paltform. (xv) The DG set should be provided with external emergency stop push button. (xvi) The ecoustic enclosure part shall be of powder coated after pre-treatment process. The powder coating shade should be as per manufacturer's design. The base frame should be painted with epoxy based black shade. Make of enclosure : As per OEM.
(E) OTHER FITTINGS. (i) Battery Charger. Battery charger having electric circuit consiting of triodes, rectifier, capacitors and resistance etc. The battery charger should be able to charge the battery at all the time whenever electric supply given to battery charger through control panel or electric power point. (ii) FUEL TANK. Inbuilt fuel tank Cap for 12 hours running as per standard specifications of manufacturer including oil level indicator etc. of manufacturer. (iii) Rubber matting Chequred of size 2 m x 1 m x 12 mm thick - 02 Nos.
Note (i) Derating factor should be considered at the time of DG set testing as per OEM recommendations. (ii) The cost of foundation shall be deemed to be included in rates quoted by the contractor as per manufacturer design. (iii) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Govt. (iv) The contractor shall arrange for artificial load (Water/Electric load) for final testing of DG Set at site and the cost is deemed to be including in above offer.
(v) One year Maint Spare as per manufacturer's maint schedule and as directed by Enger-in-Charge is deemed to be included in the above offer. (vi) One set of latest Spare part catelogue with price, exploded view of parts and user's manuel are deemed to be included in the offer. (vii) Rate quoted shall deemed to be inclusive of cable and termination from Generator to AMF Panel, with necessary holes to wall including making the distrubed surface good to meet the existing specification all as required at site complete all as specified. (viii) Civil Works : All civil works including PCC platform as per manufacturer design and related to foundations including of panel and Equipments including making food of existing disturbed surfaces during installation and commissioning of genset. The depth of the foundation shall be minimum 300 mm with antivibration pads or as recommended by the manufacturer's.
Supply, installation, testing and commissioning of diesel engine driven genrating set of capacity 160 KVA, 415 Volts, 0.8 power factor, mounted on common base frame with flexible coupling, 1500 RPM at NTP with silencer pipe protected with asbestos rope independently supported from engine to outside of power house upto 1.00 metre, AVM pads, PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) foundation as per manufacturer's design, cold starting kit, battery start with suitable cables for connecting from DG Set to panel board, with AMF Panel complete with relay and switch gears for automatic starting on main failure. The DG set shall be capable of operating in temp range of (-) 35° to (+) 35° C) at an altitude of 4200 mtr above mean sea level (MSL) complete with and including the following:- (For CHS of Pocket-II)
(A) Prime Mover:- Diesel engine of suitable capacity coolant cooled type (use min DAFC 50%), Radiator mounted, closed circuit as per IS system having rated speed 1500 RPM. Engine shall be equipped with all standard fitting as per manufacturer's recommendations and mounted on common base frame with following accessories/fittings:-
(i) Fly wheel with housing. (ii) Air Cleaner - Oil bath type (iii) Corrosion resistors. (iv) Fuel filter, Oil filter (v) FIP system including pump injectors, solenold controls, nozzled governors etc. (vi) Oil cooler and oil pumps as applicable. (vii) Radiators fan belt. (viii) Water pump assembly including thermostat etc. (ix) Silencer with buffers or expansion joints, tail piece duly insulated with asbestos lagging and sufficiently extended to carry exhaust outside the power house building/room. (x) Engine protection device against low lubricant oil pressure, high oil temperature, over speeding of engine.
(xi) Battery charging ammeter. (xIi) Ignition key and starting with push button switch. (xiII) Eletronic governor controlling. (xIv) Cold starting kit fitting with engine. (xv) Anti vibration pads of required numbers. (xvi)12 Volts DC electrical starting equipment comprising of the following :- (a) 01 No 12 Volts 180 AH battery of make Exide/Amaron/Luminous maintenance free including of iron frame as directed at site by Engr-in-Charge. (b) Battery charging altemator with in built regulator. (c) Self Starter 12 V capacity. (d) Battery leads (copper cables) of suitable size with brass thembles and terminals. Make : Kirloskar/ Cummins/ Greaves Cotton
(B) ALTERNATOR :- Alternator rating 160 KVA, 3 Phase, 50 cycles 415 volt, 4 wire supply at NTP 0.8 power factor running @ 1500 RPM, self regulated, mounted on a strong fabricated steel frame suitable for mounting on a permanent foundation to be coupled with above engine. The alternator shall be Relivent IS alongwith self regulated AVR system. Make : Kirloskar/ Cummins/ Crompton Greaves
(C) GENERATOR MONITORING SYSTEM : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lubrication oil pressure, high coolant temp (alarm and shutdown). (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm and shutdown). (iv) Data logging : Engine hours, control hours, engine start and recent fault codes. (v) Certifications : Certificates to meet the requirements of relevant ISO, CE, CSA and other equivalent.
(D) ACOUSTIC ENCLOSURE : Enclosure is free standing floor mounted factory built and moduler in construction to facilitate easy assembly at work site will be drop over housing type. It will consist of acoustically treated panel housed in sheets steel will provide easy access for maintenance, repairs and operation be designed to meet MoEF/CPCB norms. The enclosure is custom built to suit conditions, with the following features. (i) Custom built product for various equipments, which ensure the optimum performance. (ii) Rugged in constuructions maintenance free and modular designs which facilitate easy at site. (iii) 16 SWG (1.6 mm) thick CRCA sheets to be used for enclosure panel to ensure longer life against weathering action. High quality fire retardent acoustic insulation material to be used for maximum sound absorption. Acoustic layers are supported by perforted sheets.
(iv) Sheet metal components of the enclouser should undergo various stages of surface treatment prior to painting which leads to be better life of the enclouser against weathering action. (v) Special paint treatment with pure polyester powder/ epoxy to be provided for better weather resistance. (vi) Well designed ventilation system to be provided to pump up the heat in the chamber efficiently. (vii) For effective acoustic/ weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used. (viii) Working space is to be provided around the equipment for easy maintenance/ repairs. (ix) Necessary cut out provision for entry and exit of fuel lines cable to be incorporated in the enclosure as per the requirement.
(x) A see through transparent window (glass or acrylic) in front of engine panel to provide for monitering the operation. (xi) Ducting if required, bellows, mechanical hardware like locks, hinges, fasteners etc to be provided. (xii) Deliverables 75 dBA @ 1 mtr at full load under free field conditions. The temp inside the enclosure will be as per manufacturer's recommendations above ambient temp. (xiii) The enclosure should provided with bulk head light fitting for inside illumination. (xiv) The battery should place inside the enclosure beside DG set on a suitable paltform. (xv) The DG set should be provided with external emergency stop push button. (xvi) The ecoustic enclosure part shall be of powder coated after pre-treatment process. The powder coating shade should be as per manufacturer's design. The base frame should be painted with epoxy based black shade. Make of enclosure : As per OEM.
(E) OTHER FITTINGS. (i) Battery Charger. Battery charger having electric circuit consiting of triodes, rectifier, capacitors and resistance etc. The battery charger should be able to charge the battery at all the time whenever electric supply given to battery charger through control panel or electric power point. (ii) FUEL TANK. Inbuilt fuel tank Cap for 12 hours running as per standard specifications of manufacturer including oil level indicator etc. of manufacturer. (iii) Rubber matting Chequred of size 2 m x 1 m x 12 mm thick - 02 Nos.
Note (i) Derating factor should be considered at the time of DG set testing as per OEM recommendations. (ii) The cost of foundation shall be deemed to be included in rates quoted by the contractor as per manufacturer design. (iii) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Govt. (iv) The contractor shall arrange for artificial load (Water/Electric load) for final testing of DG Set at site and the cost is deemed to be including in above offer.
(v) One year Maint Spare as per manufacturer's maint schedule and as directed by Enger-in-Charge is deemed to be included in the above offer. (vi) One set of latest Spare part catelogue with price, exploded view of parts and user's manuel are deemed to be included in the offer. (vii) Rate quoted shall deemed to be inclusive of cable and termination from Generator to AMF Panel, with necessary holes to wall including making the distrubed surface good to meet the existing specification all as required at site complete all as specified. (viii) Civil Works : All civil works including PCC platform as per manufacturer design and related to foundations including of panel and Equipments including making food of existing disturbed surfaces during installation and commissioning of genset. The depth of the foundation shall be minimum 300 mm with antivibration pads or as recommended by the manufacturer's.
Supply, installation, testing and commissioning of diesel engine driven genrating set of capacity 100 KVA, 415 Volts, 0.8 power factor, mounted on common base frame with flexible coupling, 1500 RPM at NTP with silencer pipe protected with asbestos rope independently supported from engine to outside of power house upto 1.00 metre, AVM pads, PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) foundation as per manufacturer's design, cold starting kit, battery start with suitable cables for connecting from DG Set to panel board, with AMF Panel complete with relay and switch gears for automatic starting on main failure. The DG set shall be capable of operating in temp range of (-) 35° to (+) 35° C) at an altitude of 4200 mtr above mean sea level (MSL) complete with and including the following:- (01x working and 01 x standby) (For Pocket-I, Ext E/S)
(A) Prime Mover:- Diesel engine of suitable capacity coolant cooled type (use min DAFC 50%), Radiator mounted, closed circuit as per IS system having rated speed 1500 RPM. Engine shall be equipped with all standard fitting as per manufacturer's recommendations and mounted on common base frame with following accessories/fittings:-
(i) Fly wheel with housing. (ii) Air Cleaner - Oil bath type (iii) Corrosion resistors. (iv) Fuel filter, Oil filter (v) FIP system including pump injectors, solenold controls, nozzled governors etc. (vi) Oil cooler and oil pumps as applicable. (vii) Radiators fan belt. (viii) Water pump assembly including thermostat etc. (ix) Silencer with buffers or expansion joints, tail piece duly insulated with asbestos lagging and sufficiently extended to carry exhaust outside the power house building/room. (x) Engine protection device against low lubricant oil pressure, high oil temperature, over speeding of engine.
(xi) Battery charging ammeter. (xIi) Ignition key and starting with push button switch. (xiII) Eletronic governor controlling. (xIv) Cold starting kit fitting with engine. (xv) Anti vibration pads of required numbers. (xvi)12 Volts DC electrical starting equipment comprising of the following :- (a) 01 No 12 Volts 180 AH battery of make Exide/Amaron/Luminous maintenance free including of iron frame as directed at site by Engr-in-Charge. (b) Battery charging altemator with in built regulator. (c) Self Starter 12 V capacity. (d) Battery leads (copper cables) of suitable size with brass thembles and terminals. Make : Kirloskar/ Cummins/ Greaves Cotton
(B) ALTERNATOR :- Alternator rating 100 KVA, 3 Phase, 50 cycles 415 volt, 4 wire supply at NTP 0.8 power factor running @ 1500 RPM, self regulated, mounted on a strong fabricated steel frame suitable for mounting on a permanent foundation to be coupled with above engine. The alternator shall be Relivent IS alongwith self regulated AVR system. Make : Kirloskar/ Cummins/ Crompton Greaves
(C) GENERATOR MONITORING SYSTEM : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lubrication oil pressure, high coolant temp (alarm and shutdown). (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm and shutdown). (iv) Data logging : Engine hours, control hours, engine start and recent fault codes. (v) Certifications : Certificates to meet the requirements of relevant ISO, CE, CSA and other equivalent.
(D) ACOUSTIC ENCLOSURE : Enclosure is free standing floor mounted factory built and moduler in construction to facilitate easy assembly at work site will be drop over housing type. It will consist of acoustically treated panel housed in sheets steel will provide easy access for maintenance, repairs and operation be designed to meet MoEF/CPCB norms. The enclosure is custom built to suit conditions, with the following features. (i) Custom built product for various equipments, which ensure the optimum performance. (ii) Rugged in constuructions maintenance free and modular designs which facilitate easy at site. (iii) 16 SWG (1.6 mm) thick CRCA sheets to be used for enclosure panel to ensure longer life against weathering action. High quality fire retardent acoustic insulation material to be used for maximum sound absorption. Acoustic layers are supported by perforted sheets.
(iv) Sheet metal components of the enclouser should undergo various stages of surface treatment prior to painting which leads to be better life of the enclouser against weathering action. (v) Special paint treatment with pure polyester powder/ epoxy to be provided for better weather resistance. (vi) Well designed ventilation system to be provided to pump up the heat in the chamber efficiently. (vii) For effective acoustic/ weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used. (viii) Working space is to be provided around the equipment for easy maintenance/ repairs. (ix) Necessary cut out provision for entry and exit of fuel lines cable to be incorporated in the enclosure as per the requirement.
(x) A see through transparent window (glass or acrylic) in front of engine panel to provide for monitering the operation. (xi) Ducting if required, bellows, mechanical hardware like locks, hinges, fasteners etc to be provided. (xii) Deliverables 75 dBA @ 1 mtr at full load under free field conditions. The temp inside the enclosure will be as per manufacturer's recommendations above ambient temp. (xiii) The enclosure should provided with bulk head light fitting for inside illumination. (xiv) The battery should place inside the enclosure beside DG set on a suitable paltform. (xv) The DG set should be provided with external emergency stop push button. (xvi) The ecoustic enclosure part shall be of powder coated after pre-treatment process. The powder coating shade should be as per manufacturer's design. The base frame should be painted with epoxy based black shade. Make of enclosure : As per OEM.
(E) OTHER FITTINGS. (i) Battery Charger. Battery charger having electric circuit consiting of triodes, rectifier, capacitors and resistance etc. The battery charger should be able to charge the battery at all the time whenever electric supply given to battery charger through control panel or electric power point. (ii) FUEL TANK. Inbuilt fuel tank Cap for 12 hours running as per standard specifications of manufacturer including oil level indicator etc. of manufacturer. (iii) Rubber matting Chequred of size 2 m x 1 m x 12 mm thick - 02 Nos.
Note (i) Derating factor should be considered at the time of DG set testing as per OEM recommendations. (ii) The cost of foundation shall be deemed to be included in rates quoted by the contractor as per manufacturer design. (iii) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Govt. (iv) The contractor shall arrange for artificial load (Water/Electric load) for final testing of DG Set at site and the cost is deemed to be including in above offer.
(v) One year Maint Spare as per manufacturer's maint schedule and as directed by Enger-in-Charge is deemed to be included in the above offer. (vi) One set of latest Spare part catelogue with price, exploded view of parts and user's manuel are deemed to be included in the offer. (vii) Rate quoted shall deemed to be inclusive of cable and termination from Generator to AMF Panel, with necessary holes to wall including making the distrubed surface good to meet the existing specification all as required at site complete all as specified. (viii) Civil Works : All civil works including PCC platform as per manufacturer design and related to foundations including of panel and Equipments including making food of existing disturbed surfaces during installation and commissioning of genset. The depth of the foundation shall be minimum 300 mm with antivibration pads or as recommended by the manufacturer's.
Supply, installation, testing and commissioning of diesel engine driven genrating set of capacity 250 KVA, 415 Volts, 0.8 power factor, mounted on common base frame with flexible coupling, 1500 RPM at NTP, with silencer pipe protected with asbestos rope independently supported from engine to outside of power house upto 1.00 metre, AVM pads, PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) foundation as per manufacturer's design, cold starting kit, battery start with suitable cables for connecting from DG Set to panel board, with AMF Panel complete with relay and switch gears for automatic starting on main failure. The DG set shall be capable of operating in temp range of (-) 35°C to (+) 35° C at an altitude of 4200 mtr above mean sea level (MSL) complete with and including the following:- (01x working and 01 x standby) complete with and including the following:- (01x working and 01 x standby)(for Pocket-II, Ext E/S).
(A) Prime Mover:- Diesel engine of suitable capacity coolant cooled type (use min DAFC 50%), Radiator mounted, closed circuit as per IS system having rated speed 1500 RPM. Engine shall be equipped with all standard fitting as per manufacturer's recommendations and mounted on common base frame with following accessories/fittings:-
(i) Fly wheel with housing. (ii) Air Cleaner - Oil bath type (iii) Corrosion resistors. (iv) Fuel filter, Oil filter (v) FIP system including pump injectors, solenold controls, nozzled governors etc. (vi) Oil cooler and oil pumps as applicable. (vii) Radiators fan belt. (viii) Water pump assembly including thermostat etc. (ix) Silencer with buffers or expansion joints, tail piece duly insulated with asbestos lagging and sufficiently extended to carry exhaust outside the power house building/room. (x) Engine protection device against low lubricant oil pressure, high oil temperature, over speeding of engine.
(xi) Battery charging ammeter. (xIi) Ignition key and starting with push button switch. (xiII) Eletronic governor controlling. (xIv) Cold starting kit fitting with engine. (xv) Anti vibration pads of required numbers. (xvi)24 Volts DC electrical starting equipment comprising of the following :- (a) 02 No 12 Volts 180 AH battery of make Exide/Amaron/Luminous maintenance free including of iron frame as directed at site by Engr-in-Charge. (b) Battery charging altemator with in built regulator. (c) Self Starter 24 V capacity. (d) Battery leads (copper cables) of suitable size with brass thembles and terminals. Make : Kirloskar/ Cummins/ Greaves Cotton
(B) ALTERNATOR :- Alternator rating 250 KVA, 3 Phase, 50 cycles 415 volt, 4 wire supply at NTP 0.8 power factor running @ 1500 RPM, self regulated, mounted on a strong fabricated steel frame suitable for mounting on a permanent foundation to be coupled with above engine. The alternator shall be Relivent IS alongwith self regulated AVR system. Make : Kirloskar/ Cummins/ Crompton Greaves
(C) GENERATOR MONITORING SYSTEM : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lubrication oil pressure, high coolant temp (alarm and shutdown). (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm and shutdown). (iv) Data logging : Engine hours, control hours, engine start and recent fault codes. (v) Certifications : Certificates to meet the requirements of relevant ISO, CE, CSA and other equivalent.
(D) ACOUSTIC ENCLOSURE : Enclosure is free standing floor mounted factory built and moduler in construction to facilitate easy assembly at work site will be drop over housing type. It will consist of acoustically treated panel housed in sheets steel will provide easy access for maintenance, repairs and operation be designed to meet MoEF/CPCB norms. The enclosure is custom built to suit conditions, with the following features. (i) Custom built product for various equipments, which ensure the optimum performance. (ii) Rugged in constuructions maintenance free and modular designs which facilitate easy at site. (iii) 16 SWG (1.6 mm) thick CRCA sheets to be used for enclosure panel to ensure longer life against weathering action. High quality fire retardent acoustic insulation material to be used for maximum sound absorption. Acoustic layers are supported by perforted sheets.
(iv) Sheet metal components of the enclouser should undergo various stages of surface treatment prior to painting which leads to be better life of the enclouser against weathering action. (v) Special paint treatment with pure polyester powder/ epoxy to be provided for better weather resistance. (vi) Well designed ventilation system to be provided to pump up the heat in the chamber efficiently. (vii) For effective acoustic/ weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used. (viii) Working space is to be provided around the equipment for easy maintenance/ repairs. (ix) Necessary cut out provision for entry and exit of fuel lines cable to be incorporated in the enclosure as per the requirement.
(x) A see through transparent window (glass or acrylic) in front of engine panel to provide for monitering the operation. (xi) Ducting if required, bellows, mechanical hardware like locks, hinges, fasteners etc to be provided. (xii) Deliverables 75 dBA @ 1 mtr at full load under free field conditions. The temp inside the enclosure will be as per manufacturer's recommendations above ambient temp. (xiii) The enclosure should provided with bulk head light fitting for inside illumination. (xiv) The battery should place inside the enclosure beside DG set on a suitable paltform. (xv) The DG set should be provided with external emergency stop push button. (xvi) The ecoustic enclosure part shall be of powder coated after pre-treatment process. The powder coating shade should be as per manufacturer's design. The base frame should be painted with epoxy based black shade. Make of enclosure : As per OEM.
(E) OTHER FITTINGS. (i) Battery Charger. Battery charger having electric circuit consiting of triodes, rectifier, capacitors and resistance etc. The battery charger should be able to charge the battery at all the time whenever electric supply given to battery charger through control panel or electric power point. (ii) FUEL TANK. Inbuilt fuel tank Cap for 12 hours running as per standard specifications of manufacturer including oil level indicator etc. of manufacturer. (iii) Rubber matting Chequred of size 2 m x 1 m x 12 mm thick - 02 Nos.
Note (i) Derating factor should be considered at the time of DG set testing as per OEM recommendations. (ii) The cost of foundation shall be deemed to be included in rates quoted by the contractor as per manufacturer design. (iii) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Govt. (iv) The contractor shall arrange for artificial load (Water/Electric load) for final testing of DG Set at site and the cost is deemed to be including in above offer.
(v) One year Maint Spare as per manufacturer's maint schedule and as directed by Enger-in-Charge is deemed to be included in the above offer. (vi) One set of latest Spare part catelogue with price, exploded view of parts and user's manuel are deemed to be included in the offer. (vii) Rate quoted shall deemed to be inclusive of cable and termination from Generator to AMF Panel, with necessary holes to wall including making the distrubed surface good to meet the existing specification all as required at site complete all as specified. (viii) Civil Works : All civil works including PCC platform as per manufacturer design and related to foundations including of panel and Equipments including making food of existing disturbed surfaces during installation and commissioning of genset. The depth of the foundation shall be minimum 300 mm with antivibration pads or as recommended by the manufacturer's.
SCH 'A PART - XV (MISCELLENEOUS B/R & E/M WORKS) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
S&F LED lamp 7/9 Watt suitable for lamp holder pin type all as spfd and directed by Engr-in-Charge. Make : Havells/Phillips/Wipro
S&F wall mounted LED light fittings 18 watt, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete connecting electrically with 1.5 sqmm multistranded twin core copper cable PVC insulated from ceiling rose to light fitting all as directed. Make : Havells/Phillips/Wipro
S&F wall mounted LED light fittings 10 watt, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete connecting electrically with 1.5 sqmm multistranded twin core copper cable PVC insulated from ceiling rose to light fittingall as directed. Make : Havells/ Phillips/ Wipro
S&F of High power LED street light 25 Watt wall mounted IP 66 Energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source and electronic driver incl GI service bracket of minimum length 3 mtr, 1.5 mtr along the length of pole and 1.5 mtr at an angle of 45° fixed with clamps, nut, bolt and washer and electric connection with 1.5 Sqmm multistranded twin core copper cable PVC insulated from ceiling rose to fitting complete all as specified. Make : Havells/ Phillips/ Wipro
S & F VTPN distribution board 4 way iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s , complete with appropriate size copper bus bar and neutral link of make Legrand cat part No 507750 or equivalent to Simens/Schenider complete with following accessories and making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed:- (a) MCCB 3 pole 415 Volts 63 Amps, 25 KA of the same make as incomer - 01 No. (b) MCB DP 32 Amps, 240 Volts of the same make as outgoing - 04 Nos. (c) MCB SP 6 to 32 Amps, 240 Volts of the same make as outgoing - 04 Nos.
All as per item No. 4.05 above but for VTPN distribution board 8 way of make Legrand cat part No 507752 or equivalent to Simens/Schenider with following accessories:- (a) MCCB 3 pole 415 Volts 63 Amps, 25 KA of the same make as incomer - 01 No. (b) MCB DP 32 Amps, 240 Volts of the same make as outgoing - 09 Nos. (c) MCB SP 6 to 32 Amps, 240 Volts of the same make as outgoing - 06 Nos.
S&F wall mounted LED light fittings 20 watt, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete connecting electrically with 1.5 sqmm multistranded twin core copper cable PVC insulated from ceiling rose to light fittingall as directed. Make : Havells/Phillips/Wipro
Supply, installation, commissioning and testing of factory made, CPRI approved LT panel of size 1.5m x 1.2m x 0.7m, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform 60 cm above the ground level and 45 cm below the ground level complete as all directed suitable for and including the following :- (Main LT Panel, Pocket-I, Ext E/S)
(a) Aluminium bus bar, 3 Phase , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 200 Amps. (b) Change over switch 4P, 100 Amp, 415V - 01 No (c) MCCB 100 Amps, 415 Volt, 36 KA, 4 Pole, thermal magnetic release - 01 for incoming (d) MCCB 63 Amps, 415 Volt, 25 KA, 4 Pole, thermal magnetic release - 01 No (Offr Accn Block 1) outgoing (e) MCCB 32 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release - 01 No (Offr Accn Block 2) outgoing (f) MCCB 16 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release - 01 No (Street light) outgoing (g) MCB SPN 6 Amps, 240 Volt, 6 KA, thermal magnetic release - 03 Nos ( Offr Garages 1, 2 & 3) outgoing
Supply, installation, commissioning and testing of factory made, CPRI approved LT panel of size 1.5m x 1.2m x 0.7m, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, grouting the legs of panel in PCC foundation 1:4:8 platform 60 cm above the ground level and 45 cm below the ground level complete as all directed suitable for and including the following :- (Main LT Panel, Pocket-II)
(a) Aluminium bus bar, 3 Phase , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 400 Amps. (b) Change over switch 4P, 250 Amp, 415V - 01 No (c) MCCB 250 Amps, 415 Volt, 36 KA, 4 Pole, thermal magnetic release - 01 for incoming (d) MCCB 250 Amps, 415 Volt, 36 KA, 4 Pole, thermal magnetic release - 01 No (Sub LT panel No.1) outgoing (d) MCCB 63 Amps, 415 Volt, 25 KA, 4 Pole, thermal magnetic release - 01 No (S/L ORs block 2) outgoing (e) MCCB 16 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release - 01 No (street light) outgoing
Supply, installation, commissioning and testing of factory made, CPRI approved LT panel of size 1.2m x 1.2m x 0.6m, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, grouting the legs of panel in PCC foundation 1:4:8 platform 60 cm above the ground level and 45 cm below the ground level complete as all directed suitable for and including the following :- (Sub LT Panel No. 1, Pocket-II)
(a) Aluminium bus bar, 3 Phase , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 400 Amps. (c) MCCB 250 Amps, 415 Volt, 36 KA, 4 Pole, thermal magnetic release - 01 for incoming (d) MCCB 125 Amps, 415 Volt, 36 KA, 4 Pole, thermal magnetic release - 01 No (Sub LT panel No.2) outgoing (d) MCCB 63 Amps, 415 Volt, 25 KA, 4 Pole, thermal magnetic release - 01 No (S/L ORs block 1) outgoing (e) MCCB 32 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release - 02 Nos (CH & DH, JCO mess) outgoing
Supply, installation, commissioning and testing of factory made, CPRI approved LT panel of size 1.2m x 1.2m x 0.6m, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform 60 cm above the ground level and 45 cm below the ground level complete as all directed suitable for and including the following :- (Sub LT Panel No 2) (Pocket-II)
Supply and fixing LED street light 35/36 Watt 230 V AC, atleast 100 Lumens per watt outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp fitted on poles including making electric connections from junction box to light fitting all as specified and directed. Note :- (a) Item rate includes the cost of assembling of the complete fitting and its testing before and after mounting or erection etc. for proper functioning. (b) Item rate includes the cost of GI service bracket of minimum length 3 mtr, 1.5 mtr along the length of pole and 1.5 mtr at an angle of 45° , bracket mounting clamp, bolts and nuts and wiring from the fitting to the junction box inside the pole and bracket with 1.5 sqmm twin core PVC sheathed wire FRLS all as specified and directed by Engr-in -Charge.
Supply and fixing Junction box out door type made out of 3.15 mm thick MS sheet powdered coated with locking arrangement of size (35 cm x 20 cm x 10 cm) including 01 No 6 Amp SP MCB, 4 Nos bus bar of suitable size with suitable number of holes fixed on Street light pole with suitable MS clamps all as specified and directed by Engineer-in-Charge.
Supply and fixing Junction box out door type made out of 3.15 mm thick MS sheet powdered coated with locking arrangement of size (30 cm x 15 cm x 8 cm) including 01 No 6 Amp SP MCB, 2 Nos bus bar of suitable size with suitable number of holes fixed on Street light pole with suitable MS clamps all as specified and directed by Engineer-in-Charge.
Supply, installation, commissioning and testing of factory made, CPRI approved LT panel, indoor type made out of CRCA sheet 2.00 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform including cutting chases to existing PCC floor and making good the disturbed surfaces to match with the existing specification complete as all directed suitable for and including the following :- (PKT-II)
(a) Aluminium bus bar, 3 Phase , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 100 Amps. (b) Change over switch 4P, 40 Amp, 415V - 01 No (c) MCCB 40 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release- 01 for incoming (d) MCCB 25 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release - 02 No outgoing
Supply and fix CI Foot Valve conforming to IS 4038, 80 mm dia.
M&L for Construction of brick masonary valve pit of size.1.2X1.2X1.8 mtr (internal diamensions) including excavation and earth work in any type of soil, PCC 1:4:8 type B-2 in foundation brick work in CM 1:4, 15mm thick plastering in CM 1:4 internally and flush pointing externally in same mortar as the work process angle iron frame 40X40X6mm, with 3mm thick MS sheet cover with 12 mm dia handle and locking arrangement (including lock and two Keys) and two coats of synthetic enamel paint over a coat of red oxide primer, filling saw dust into the pit and providing extension rod 0.6 m long to operate sluice valve from top and welding it with sluice valve spindle .
M&L for Construction of brick masonary valve pit of size.0.9X0.9X1.8 mtr (internal diamensions) including excavation and earth work in any type of soil, PCC 1:4:8 type B-2 in foundation brick work in CM 1:4, 15mm thick plastering in CM 1:4 internally and flush pointing externally in same mortar as the work process angle iron frame 40X40X6mm, with 3mm thick MS sheet cover with 12 mm dia handle and locking arrangement (including lock and two Keys) and two coats of synthetic enamel paint over a coat of red oxide primer, filling saw dust into the pit and providing extension rod 0.6 m long to operate sluice valve from top and welding it with sluice valve spindle .
M&L for providing antifreezing /tracer cable required to keep the pipe warm upto avoiding freezing all as specified including electric wiring cable of suitable size for connection
M&L for cutting existing cast iron/ DI/ GI pipes and reducing to require length and insertion of new Tee brances of suitable size to take branch connection of 80mm/50mm dia.
S&F Water storage vertical type of 5 star rating copper tank electric operated Geyser of cap 25 ltrs , connected accessories like anchor fastening, nuts, bolts, PCC work cutting chases to wall making good the disturbed surfaces to match with the existing specification including necessary electric and water connections and testing on completion complete all as specified and directed by Engr-in -charge.
Supply & Fixing MCB, Single pole and neutral 32 Amps, 10 KA
S&F PUF insulated water storage tank of capacity 5000 ltr-3 layers outer layer of FRP, 2nd inner layer of Polyurethane foam 75mm thick and 3rd layer of HDPE tank.
S&F PUF insulated water storage tank of capacity 1000 ltr-3 layers outer layer of FRP, 2nd inner layer of Polyurethane foam 75mm thick and 3rd layer of HDPE tank.
S&F PUF insulated water storage tank of capacity 500 ltr-3 layers outer layer of FRP, 2nd inner layer of Polyurethane foam 75mm thick and 3rd layer of HDPE tank.
M&L for construction of PCC platform 1.25m x 1.25m x 0.6m high from natural ground level incl necessary earthwork, PCC block walling, PCC 1:4:8 type D-2 in fdn,100mm tk PCC 1:2:4 type B-2 over 75mm thick sub base in flooring
M&L for construction of PCC platform 1.80m x 1.80m x 0.6m high from natural ground level incl necessary earthwork, PCC block walling, PCC 1:4:8 type D-2 in fdn,100mm tk PCC 1:2:4 type B-2 over 75mm thick sub base in flooring
Note :- The Schedule of credit has been attached in tender in PDF format and amount of credit shall be deducted from the total amount of BOQ to arrive at the Lump sum amount.
N K Gupta Builders Pvt. Ltd.
M/S ABDUL SALAM MIR CONSTR CO PVT. LTD
Saru Enterprises Pvt Ltd
Taru Enterprises Pvt Ltd
RAGHUSONS INFRA ENGINEERING PVT. LTD
M/s Madan Lal Bansal and Co. Contractors Pvt. Ltd.
NITYA NAND AND SONS CONTRACTORS PVT LTD
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid