Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-Finance | L1 | Accepted-Finance Lowest rate found. | |
| 2 | L2₹40.1 L+₹5.4 L (15.7%)Accepted-Finance DADRA AND NAGER HAVELI DN | DADRA AND NAGAR HAVELI | THE DADRA AND NAGAR HAVELI AND DAMAN AND DIU | 396193 | L2 | Accepted-Finance High rate found. | |
| 3 | L3₹45.6 L+₹10.9 L (31.3%)Accepted-Finance | L3 | Accepted-Finance High rate found. |
Tender Value
₹29.9 L
EMD Value
₹59,822
Closing Date
4 Sept 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Exe.,Engg., PWD, WD-I, Daman.
The Multi Office Complex, PWD, 2nd Floor, Near Moti Daman Market, Moti Daman.
Repairing, painting and construction of compound wall and other allied work of various Govt. Higher Secondary School at Nani Daman. (E-30225).
2023_DAMAN_3064_1
Tender Notice No.65/02/2023-24
Open Tender
Civil Works
Works
180 days
Daman District.
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
The Exe.,Engg., PWD, WD-I, Daman.
₹59,822
16 Sept 2023
25 Aug 2023
4 Sept 2023
25 Aug 2023
4 Sept 2023
25 Aug 2023
Amount
Civil work
Dismentaling of sheet roofing including ridges, Hips, Valleys, Gutters etc. stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(i) G.I.sheet roofing.
Remove, repairing and refixing of roof sheet of any thickness including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.5 mm thick with zinc coating not less than 275 gm/ m2
Dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.
Providing and fixing false ceiling made up of 19 mm thick plywood of ISO standard approved make at any location up to any height as directed. Item includes all mouldings and chamfers to be made as per original design , dismentaling of old ceiling etc as directed by EIC.
Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular edge & 15 mm Thick Densified edges on the Tile Periphery for Extra Strength The Light weight calcium silicate ceiling tiles shall have , light reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity0.043° w/m KC.for the best thermal Insulation . The Light weight calcium Silicate tile shall be of approved texture Fine fissured/ Spintone/Cosmos having NRC value of 0.5 & Globe having NRC value of 0.75 NRC or equivalent of size 595 X 595 mm to be laid on true horizontal level suspended inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and size of 24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and cross ‘T’ of size 24X28mm made out of 0.33mm (Minimum) sheet spaced 1200mm along spaced between main ‘T’ at 600mm centre to centre to form agrid of 1200X600mm and secondary cross ’T’ of length 600mm and size 24x28mm made of 0.30 mm thick (Minimum) sheet to be interlocked at middle of the 1200X600mm panel to form grid of size 600X600mm resting on periphery walls/partitions on a perimeter wall angle pre-coated steel of size (24X24X3000mm made of 0.40mm thick (minimum) sheet with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick Densified edges light weight calcium silicate ceiling tiles of approved texture (Fine Fissured/Cosmos/Spintone) in the grid including, cutting /making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required, Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25X35X1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel level clips of size 85X30X0.8mm, spaced at 1200mm centre to centre long main ‘T’ bottom exposed with 24mm of all T-sections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by engineer-in-charge.Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tiles shall have NRC. Value of 0.50 (Minimum) for Fine fissured/Spintone/Cosmos and 0.75 NRC for Globe, light reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity. 0.043° w/m KC.for the best thermal Insulation
Remove, repairing and refixing of roof sheet of any thickness including providing and fixing structural steel etc as per the requirements, vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Providing and filling in foundation & plinth with Rubble filling in layer of 20 cm thickness including watering, ramming and consolidating etc. comp.
Providing and laying cement concrete 1:2:4 (1- Cement : 2- Coarse sand : 4- graded stone aggregates 20 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth
Providing material and labour for laying in position batched and machine mixed design controlled cement concrete M25 from Below plinth & upto plinth Level produced in batch mix machine, using cement content as per approved design mix, including pumping of concrete to site of laying including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve work ability without impairing strength and durability as per direction of Engineer-in-charge. using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to latest IS 383 with minimum cement content (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete work in Foundation, footings, base of columns, pavement, grade slab, roads and Mass concrete including cost of Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. excluding cost of reinforcement and removal of the same for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
Providing and laying in position Ready Mixed M25 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying in laying in Columns, Fins, Pillars posts, Rectangular polygon in plan and struts all work upto plinth level including cost of admixtures in recommended proportions as per IS: 9103 as per direction of the EIC. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) including cost of Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. and removal of form for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
Providing and laying in position Ready Mixed M25 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying in Beams, Plinth beam, Girders, Lintels and Cantilever all work upto plinth level including cost of admixtures in recommended proportions as per IS: 9103 as per direction of the EIC. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) including cost of Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. and removal of form for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge. Height of propping and centering below supporting floor to ceiling not exceeding 4.0 M.
Providing and laying in position Ready Mixed M25 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying in laying in Columns, Fins, Pillars posts, Rectangular polygon in plan and struts all work above plinth and upto floor I level including cost of admixtures in recommended proportions as per IS: 9103 as per direction of the EIC. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) including cost of Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. and removal of form for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:6 (1- Cement : 6 -fine sand)(B) Conventional. Extra for brick work in superstructure above plinth level upto floor two level (B) Conventional
Providing and laying in position Ready Mixed M25 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying in Beams, Plinth beam, Girders, Lintels and Cantilever all work above plinth and upto floor IV level including cost of admixtures in recommended proportions as per IS: 9103 as per direction of the EIC. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) including cost of Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. and removal of form for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge. Height of propping and centering below supporting floor to ceiling not exceeding 4.0 M.
20mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete.
Applying two coats of putty & two coats of primer of approved brand and manufacture on new wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth.
Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth.
Providing and fixing Door with 35mm chill wood flush door, 1.0mm laminate on both side, teak wood pati on all four side, ss hinges. mortise lock, stopper, fixing with screw fevicol, nail etc complete as directed by engineer in charge.
Providing and fixing FRP frame size 125x65 mm and 35mm thick FRP shutter with wood grain raised panneled design finish shutter having extra reinforcement on sides & edges in Gel coat finish. The core of the shutter & frame is to be filed up with injected polyurethene foam done in situ alongwith embedded wooden pieces for stiffening & also taking hinges & fintures. The whole FRP frame & shutter is to be water proof weather proof, termite proof & resistance to mild acid/alkali. Rates are to be inclusive of S.S hinges with fastener sleeve & alluminium fixtures & fastenings.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint, brushing, interior to give an even shade including cleaning the surface an even shade including cleanicn the surface of all dirt, dust and other foreign matter.
Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc complete
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. :Providing material and labour charge for fixing Powder coated (50 Microns) Alluminium DOOR with pipe section 63mm x 38mm x 1.63 mm including glazing clips and 25mm x 25mm x 1.80 mm having cross section C/C not more than 0.7 x 1.00 meter and using Hardnersheet / Clear / Frosted Glass 6.0mm thick and/or 4mm Thick ACP Sheet of color as approved fitting with rubber gasket etc complete, Including Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.and Door closer etc. complete as directed by Engineer in charge with stainless steel cover plate minimum 1.25mm thickness, with Providing and fixing S.S. Door handles(Heavy) with screws etc 200mm long on both side, including Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete as directed by Engineer-incharge.
Providing TMT Bar FE 500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level
Dharmik Construction
NAUSHAD M HASNANI
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .