| 1 | L1₹25.2 LAccepted-AOC MASTER BUILDING DALHOUSIE ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹25.2 L Quoted ₹28.9 L | L1 | Accepted-AOC SINCE L1 BIDDER |
| 2 | L2₹30.6 L+₹1.7 L (5.98%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹30.6 L+₹1.7 L (5.98%) | L2 | Rejected-Finance SINCE NOT L1 BIDDER |
| 3 | L3₹33.1 L+₹4.3 L (14.8%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹33.1 L+₹4.3 L (14.8%) | L3 | Rejected-Finance SINCE NOT L1 BIDDER |
| 4 | L4₹39.7 L+₹10.8 L (37.5%)Rejected-Finance | ₹39.7 L+₹10.8 L (37.5%) | L4 | Rejected-Finance SINCE NOT L1 BIDDER |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
8 Feb 2022, 6:00 pmClosed
CWE AMRITSAR
HQ CWE AMRITSAR
REPAIR AND MAINT OF HT SWITCH GEARS TRANSFORMER HT OH LINE UG CABLE AND CONNECTED ACCESSORIES AT TIBRI MIL STN UNDER GE GURDASPUR
2022_MES_500659_1
CWE/ASR-63/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE GURDASPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE GURDASPUR
₹60,000
Yes
10 Mar 2022
11 Jan 2022
15 Feb 2022
11 Jan 2022
8 Feb 2022
27 Jan 2022
Amount
Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting out all complete as specified & directed by Engr-in-Charge.
All as per item No.1 above but depth exc. 1.5 mtr and n. exc 3 mtr.
Returning, filling in, including spreading,leveling,watering and well ramming in layers each n.exc 25 cm thick in soft loose soil all complete as specified & directed by Engr-in-Charge.
Removing excavated material n exc. 50mtr and depositing where directed at a level n exc. 1.5 mtr above,the starting point complete as specified & directed by Engr-in-Charge.
Supply and laying un-reinforced precast concrete cable cover, class HVP, type I, flat, size 300 mm x 180 mm x 40 mm laid flat in trenches over the cable with the length of cable cover perpendicular to the direction of cable length, adjacent/abutting each-other complete all as specified and directed by Engineer-in-Charge.
M&L for Sand cushioning trenches using fine sand to under ground cable, laid in two layers 8cm before laying the cable & 15cm after laying the cable complete all as specified.
Labour for drilling hole under the road with the help of bocki / by manually or by machine for crossing GI tubing of any size for cable protection complete all as specified and directed
M&L for cable protection GI tubing fix in repair light grade fixed along the pole/under road/along the wall of size 80mm bore with necessary clamps all as directed.
M&L for cross arms in replacement , bracing, supports, clamps and brick plates, fabricated from structural steel section including nut bolts washers including welding ,bending , cold or hot drilling holes for bolts in any shape or size as indicated in drawings or as directed, including two coats of aluminium paint over a coat of red oxide all specified.
Supply and fixing in replacement of vertical switch air break gang operated switch tripple pole mechanically operating mounted on insulator and steel frame with operating mechanism worked from ground level for current rating up to 200 Amps and working pressure of 11000 volts grade consisting of 4 insulator per pole with 20mm dia GI medium grade operating handle and locking arrangements fixed with down rod operating brackets all specfied & directed by Engr-in-charge.
Supply and fixing in replacement of vertical switch air break gang operated switch tripple pole mechanically operating mounted on insulator and steel frame with operting mechanism worked from ground level for current rating up to 400 Amps and working pressure of 11000 volts grade consisting of 4 insulator per pole with 20mm dia GI medium grade operating handle and locking arrangements fixed with down rod operating brackets all specfied & directed by Engr-in-charge.
Supply & laying in replacement underground XLPE insulated and PVC sheathed galvanised (E) steel strip or wire armoured (under ground) heavy duty electric cable with stranded aluminium conductor 11000 volts (E) grade of cross sectional area 185 Sqmm 3 core conforming to IS-7098 (partII) 1985 with the latest ammendment, laid in trenches/ducts/through pipes/in floor/road/along the pole etc all as sdpecified & directed by Engr-in-charge
All as per item No.12 above but of size 120 Sqmm 3 core.
All as per item No.12 above but of size 95 Sqmm 3 core.
Repair/servicing of existing GOD and decarbonized , proper function mechanism device fixed to nut bolt and use petrolium gel, proper jumpering with P-G clamp and replacement of u/s parts of the GOD Note :- Replacement of items like PG clamp, Insulater, Male, Female link etc and conductor will be measured and paid saperately.
S & F in replacement of post insulators with necessary nut bolts and accessories complete as specified & directed by Engr-in-Charge.
S & F in replacement of P G clamp of any size and type all as directed by Engineer-in-Charge
S & F in replacement HT movable link assembly with barrided copper strip of current rating 200 Amps for GOD 11000 volt all as directed by Engineer-in-charge
Supply and fix in repair of male link assembly with brass tinned contact for GOD 11000 Volt grade complete all as specified
Supply and fix in repair of female link assembly with brass tinned contact for GOD 11000 Volt grade complete all as specified
S & F in replacement HT fix link with tenson spring assembly with brass tinned contact for 11000 volt GOD all as directed by Engineer in Charge
Supply and errecting in replacement true vertical position prestressed concrete poles 11 metre long 152mm x 152mm at top and 152mm x 260mm at bottom, class - 9 including painting of 05 Nos bands/ strips of 30cm wide each with two coats of synthetic enamel paint (black and yellow) at a distance of 30cm from the plinth block upto 1500mm height and marking / sign writing of pole number and feeders locations of pole with thick synthetic enamel paint (white) complete all as specified and directed to match the existing poles. Note :- excavation and earth work shall be masurered and paid separately.
M&L for PCC 1:3:6 type C:2 using 40mm graded crushed stone aggreate as in foundation for pole/stay assembly foundation coping of poles etc complete as specified & directed by Engr-in-Charge.
M&L for PCC 1:4:8 type D:2 using 40mm graded crushed stone aggreate as in foundation for pole/stay assembly foundation coping of poles etc complete as specified & directed by Engr-in-Charge.
M&L for PCC 1:2:4 type B:2 using 40mm graded crushed stone aggreate as in foundation for pole/stay assembly foundation coping of poles etc complete as specified & directed by Engr-in-Charge.
Material & labour for replacement of stay assembly complete comprising of 7/3.15 galvanised stranded stay wire of required length, fixed to pole with and including FI clamps 50 x 6 mm, bolt, nuts washers, GI stay rod 20 mm dia and 1800 mm long, stay bow 400 x14mm, GI steel plate 300x300x6mm, loop insulator of size 90 x 140mm clearance hole 16mm including two coats of aluminium paint over a one coat of red oxide primer on exposed mild steel work all as shown in Electrical Plate No. 1 of SSR part - I 2009 on Page No 495 compelete all as specified and directed.
Labour for cutting the tree branches passing near the HT /LT OH line of width/ girth not more than 30cm upto 3 meter distance from adjacent pole or four/two pole structure all as specified and directed by EIC. Note ;- (i) Each span having 50 mtr distance approximately (ii) All cutting branches of trees shall be thrown away /burnt at approximately 200 to 500 mtr away from site. (iii) Cutting the tree branches as when required after intimating by telephonically /whats app msg or letter .Failling which Rs 100/per day will be levied on the contractors as penality. (iv) Transport shall be provided by contractor to thrown away the branches. No amount shall be paid seperately for transport. All rates are deemed to be inclusive in the quoted rates.
M & L lightening arrestor in replacement expulsion type for out door use complete with all fittings discharge capacity 65 KA suitable for 11000 volts including bracket, clamps, nuts, bolts washers and connection to each wire complete all as specified. Make-makes specified in appendix 'B' section-II.
Supply in replacement ACSR conductor including stretching on OH line including binding on insulators with aluminium binding wire including jumpers and jointing all specified & directed by Engr-in-charge. Note :- (i) Weight of ACSR or all aluminium conductor drawn for OH lines is to be measured by measuring tant horizontal distance between centres of two adjacent poles and compounding the weight of conductor of that size and length and 3 % extra added for sag, jointing, jumpers and binding etc. (ii) Weight of conductor shall be calculated from tables given in the relevant I.S.
M & L for fault detection in damaged UG cable by using cable fault detector / locator vech mounted to a accuracy of 2 mtr for various location at tibri mil stn of any size and type upto 11KV incl the following in quoted rate all as directed and specified and directed by Engr-in-Charge (i) The fault should done by 2 days of time frame after informed to the contractor / contractor REP by telephonically /whats app msg or letter .Failling which Rs 3000/per day will be levied on the contractors as penality.( ii) After locating the fault the rectification of the fault is the responsiblity at the contractor (iii) The cable straight through joint /end termination will be measures and paid seperately in relevent items of contract.
Restreching of existing ACSR conductor of any size any type as required sag fixed on OH line & insulators/cross Arms on poles properly binding with aluminium complete all as specified and directed.
M&L in replacement GI steel earth wire continuity conductor, HT poles /cradles of different shapes of size 4mm dia all complete as specified & directed by Engr-in-Charge.
M&L in replacement for termination in door type heat shrinkable jointing kit suitable for 11KV cable 50 to 95 sqmm, 3 core all complete as specified & directed by Engr-in-Charge
All as per srl item No.33 here in before but 120 to 185 Sqmm, 3 core.
All as per srl item No.33 here in before but 240 to 300 Sqmm, 3 core.
M&L in replacement for termination out door type heat shrinkable jointing kit suitable for 11KV cable 50 to 95 sqmm, 3 core all as specified and directed.
All as per srl item No.36 here in before but 120 to 185 Sqmm, 3 core.
All as per srl item No.36 here in before but 240 to 300 Sqmm, 3 core.
M&L in replacement for straight through jointing Kit heat shrinkable type suitable for 11KV cable 50 sqmm 3 core to 95 sqmm 3 core all as specified and directed.
All as per srl item No.39 here in before but 120 to 185 Sqmm, 3 core.
All as per srl item No.39 here in before but 240 to 300 Sqmm, 3 core.
Taking down the defective unserviceable transformer from existing site from pole and Sub Stn with the help of man power & chain pully block or by crane etc including disconnecting all electrical and mechanical connections from the site and carrying to workshop for repair and replacement of old burnt u/s items as well as winding etc including transporting of capacity 50 KVA to 100 KVA Transformer (incl 100 KVA) all as specified and directed BY ENGR -IN -CHARGE.
All as per srl item No.42 here in before but 125 KVA to 250 KVA (INCL 250 KVA)
All as per srl item No.42 here in before but 300 KVA to 415 KVA(INCL 415 KVA)
All as per srl item No.42 here in before but 500 KVA to 750 KVA.
M&L for opening, dismantling the transformer 50 KVA to 100( incl 100KVA capacity of transformer) KVA by lifting the top cover taking out the HT/LT core and draining out the transformer oil in clean barrel including cleaning the transformer chamber (body) inside and outside thoroughly with emery paper and cloth then checking then checking the winding and other worn-out parts such as HT/LT coils silicon stamping and other connected items as Tap changer, breather assembly etc and replacement of HT and LT coil winding with DPC enameled copper/aluminum wire/strip of adequate size, gauge and number of turn complete and connected to existing serviceable strip by jointing with soldering and reinsulation of cotton tape over strip including using insulating material like varnish to limb coil fire proof type and sleeves etc by drying and baking of insulating material in heating chamber in adequate temperature. Reassembling the transformer LT/HT connection complete. Testing of transformer after reassembly complete on No load at workshop and on load at site including painting to the transformer with super enameled paint all as specified and directed. Note:(i) unserviceable transformer should be rewinding in workshop within 09 days time frame on reaching at the transformer in workshop .falling which 1000/- day will be levied to the contractor as a penality.(ii) HT/LT coils and other connected items shall be measured and paid separately. (iii) Transport shall be provided by contractor to left the transformer at site from workshop after repair the transformer at his own cost . No amount shall be paid seperately for transport. All rates are deemed to be inclusive in the quoted rates.
All as per srl item No.46 here in before but 125 KVA to 250 KVA.
All as per srl item No.46 here in before but 315 KVA to 400 KVA.
All as per srl item No.46 here in before but 500 KVA to 750 KVA.
HT/LT coil winding with super enamelled copper wire/ strip of existing size & guage for winding the transformer HT/LT coils incl insulating materials all as specified and directed .
HT/LT coil winding with DPC or enamelled aluminium strip /wire of existing size & guage for winding the transformer coil HT/LT coils all as specified and directed .
Supply in replacement of HV bush Insulator complete with rod as per existing material & size and nut suitable for indoor/outdoor type transformer 50 KVA To 100 KVA .
All as per srl item No.52 here in before but 125 KVA to 250 KVA.
All as per srl item No.52 here in before but 300 KVA to 400 KVA.
All as per srl item No. 52 here in before but 500 KVA to 750 KVA.
Supply and fix in replacement of LV bush Insulator complete with rod as per existing material & size and nut suitable for indoor/outdoor type transformer 50 KVA To 100 KVA.
All as per srl item No.56 here in before but 125 KVA to 250 KVA.
All as per srl item No. 56 here in before but 300 KVA to 415 KVA.
All as per srl item No. 56 here in before but 500 KVA to 750 KVA.
Supply and fix in replacement of silica gel in breather assembly different capacity of transformer all as directed by Engineer in charge
Supply and fixing breather assembly complete of any type and capacity of transformer all complete as specified & directed by Engr-in-Charge
Supply and fixing of the temperature gauge of the different type suitable for indoor/ out door type tranformer 50 KVA to 750KVA make all as specified and directed
Supply and fixing of oil pressure gauge of the different type suitable for indoor/ out door type tranformer 50 KVA to 750KVA make all as specified and directed
Supply and fixing, in replacement, 11 KV Digital Amp meter 0-100 Amp complete all as specified and directed.
Supply and fixing in replacement Digital volt meter 0-500 Volts working in 220 DC volts complete all as specified and directed.
Supply and fixing in replacement Digital volt meter 0-66 KVolts complete all as specified and directed.
Supply and fixing in replacement Digital volt meter 0-11 KVolts complete all as specified and directed.
Supply and fixing in replacement of safe high voltage tape roll complete all as specified and directed
Supply and fixing in replacement of PG clamp size 66 KV line Horizontal and Vertical type complete all as specified and directed.
Supply and fixing Male - female clamp suitable for 66 KV line complete all as specified and directed.
Repair of the gear assembly of SF6 breaker, by taking out the same and including transportation and replace the worn out parts / defective parts and commissioning the same including testing complete all as directed by Engineer-ini-charge
Supply and fixing of 66/11KV HT side bushes of 8 MVA transformer all complete as specified & directed by Engr-in-Charge
Supply and fixing of 66/11KV LT side bushes of 8 MVA transformer all complete as specified & directed by Engr-in-Charge
Supply and filling of SF-6 gas all complete as specified & directed by Engr-in-Charge
Supply and fixing of HRC fuses of capacitor 06/10/16 AMP for DC supply at VCB and Battry chargerpannel all complete as specified & directed by Engr-in-Charge
Supply and fixing of barrel fuses of capacitor bank all complete as specified & directed by Engr-in-Charge
Supply and fixing of oil winding temp gauge of 8 MVA transformer all as directed by Engineer in charge
Supply and fixing of coarse aggregate in 20mm graded in layers at Main Receiving Station and appliying of lime solution before laying of coarese aggregate all as directed by Engineer in charge
M&L for opening Dismantling the transformer of capacity 50 kVA to 750 KVA for repairing of transformer oil leakage from the top cover and HT/LT bushes, by lifting the top cover and draining out the transformer oil in barral including cleaning the transformer chamber (body) inside and out side thoroughly with emery paper and cloth than checked the winding and other parts for smooth functioning and replacement of top cover and LT and HT bush gasket and reassenbling the transformer LT/HT connection with help of soldering..Testing of transformer after reassembly complete on No load and full load at site incl painting to the transformer with super enammed paint all as specified and directed. Note :- The job includes the cost of gasket set, LT / HT bushes, nuts, bolts, washers, cost of painting etc required for the complete job. Only transformer oil will be measured and paid separately.
Opening Dismantling the power transformer of capacity 5MVA and 8 MVA for repairing of transformer oil lekage from the top cover and HT/LT bushes, by lifting the top cover and draining out the transformer oil in barral including cleaning the transformer chamber (body) inside and out side throughly with emery paper and cloth than checked the winding and other parts for smooth functioning and replacement of top cover and LT and HT bush gasket and reassembling the transformer LT/HT connection with help of soldering..Testing of transformer after reassembly complete on No load and full load at site incl painting to the transformer with super enammed paint all as specified and directed. Note :- The job includes the cost of gasket set, LT / HT bushes, nuts, bolts, washers etc required for the complete job. Only transformer oil will be measured and paid separately.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 meter ground level with top edge of the earth plage at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using galvanised iron strip of 32 mm x 6mm by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and the other end of the earth strip connected to main switch board protected by galvanized iron light grade pipe 40mm bore fixed on wall laid in floor and GI pipe 20mm bore light grade for watering with funnel and wire mesh, PCC Chamber in cement concrete 1:3:6 type C-2 and RCC 1:2:4 type B-1 and reinforced with MS bars 6mm dia @ 10 cm C/C both ways as in pit cover including necessary excavation and earth work in any type of soil and disposal of soil to a distance not exceeding 50 mtr away all as shown in electrical plate No 3 of SSR 2009 (Part-I)
Supply and fix galvanised iron strip 32mm x 6mm as earthing lead fixed to wall / pole or buried in ground or drawn in pipe.
M & L in replacement danger notice plate for HT pole of size 20 cm x 15cm of 1.6 mm thick mild steel sheet viterious enamaled white with letter figur and conventional skull and bones "DANGER" (English, Punjabi and Hindi) in signal red colour and fixed with MS clamps made of 25mm x 3mm MS flat Iron bolts nuts complete including two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed.
M & L in replacement pin type insulator porcelain vetreous white brown or green including one galvanised metal steel spindle two galvanised iron washer and one galvanised iron nuts 150mm height and 150 mm dia 11000 volt grade all as specified and directed.
Supply and fixing in replacement disc type insulator porcelein vitreous 145 mm high and 255 mm dia ball and socket type white/brown or green single disc assemblely for 11000 volt grade complete all as specified and directed.
Dehydratin and filteration of transformer oil at site by using dehydration machine and fiteration to be carried out till the time the dielectric strength achieved to min 40 KV complete all as specified and directed. Note : The transformer dehydration machine shall be arrange/brought by contractor at site no extra amount paid to the contractor.
Material and labour for toping up of the transformer and new with T/Oil having dielectric strength not less than 40 KV. Make - Poweroil/Savita/Transol or equivalent makes as specified in Appx 'B'
Material & labour for painting to panels & feeder pillar box, any sizes, installed at 66 KV Sub Stn with two coats of super enamelled paint of approved colour with spray painting machine including preparation of the surface complete all as specified and directed.
Material & labourfor painting to transformer rating 50 KVA and 500 KVA, out door type installed at diffrent Sub Stn including mounting channels and connected accessories with two coats of super enamelled paint of approved colour spray painting machine including preparation of the surface complete all as specified and directed.
Supply in replacement of brass nut bolt washers off sizes as per samples for HT/LT SIDE OF TRANSFORMERS AND END TERMINATORS
Repair & replacement of Current Transformer moulded in epoxy compound with dual ratio 30/15/5/5 Amps complite connection with Auto wire 2.5 sqmm including beading as per existing in VCB at site all as per specified and directed by Engneer- in - Charge. (Note-: Circuit diagram will be produce after fixing the CT in VCB at site.
All as per Ser Item No 91 but ratio 50/10/5/5 Amps.
M&L for fault detection in VCB control pannel capacitor bank at MRS 66 KV & DISCONNECTED of HT CONNECTION & DC connection from existing bus bar carefully and other parts carefully incl taking down the VCB trolly compl & disconnect the male/female contacts & clean the bushbar with carbon tetra chloride liquid throughly bushbar spout trolly spout applying a one coat of 11 KV insulation quoting as per sample onbushbar,spouts & other connected parts and rectified the fault by repair or replacement by spare parts and reassembling the same reconnecting the HT & dc connection compl in functional order incl testing on existing load all as specified & directed NOTE (i) The fault should be done by 3 hrs of time frame after intimated by telephonically /whats app msg or letter .Failling which Rs 2000/per day will be levied on the contractors as penality. (ii) COST of spares parts relay ,auxillary ,triping coil ,etc shall be measured and paid seperately.
Suppy in replacement the existing U/S auto battery charger suitable for charging of 12V/24 V/36V batteries all as specified and directed.
Supply and fixing of XLPE insulated PVC Sheathed single core Aluminium unarmoured of 11000 Volts grade cable for using as a jumber in HT overhead line whereever required of size 90 sqmm all as directec by engineer in charge
Supply and fix in replacement of tap changer for adjusting the voltage with brass parts as per sample of existing for indoor/ outdoor type transformer 50 KVA To 100 KVA all as specified and directed.
All as per srl item No. 96 here in before but 125 KVA to 250 KVA.
All as per srl item No. 96 here in before but 300 KVA to 415 KVA.
All as per srl item No. 96 here in before but 500 KVA to 750 KVA.
Comprehensive maintenance of 66/11KV sub station equipment complete all as specified and directed and testing by Punjab State Power Corporation Limited (PSPCL) authorised personal:- (a) Transformer 66/11 KV 8 MVA - 01 No (b) Transformer 66/11KV 5 MVA - 01 No (c) 66 KV SF-6 based Breakers 02 Nos (d) VCBs / OCBs- 12 Nos and any other relevant HT equipment. Notes:- (a) Checking of 11 KV functioning of all the tripping system / relay displayed on the control relay panel - such as differential O/C, earth fault, metering circuits and all othe protection from transformer - oil temp, trip, OLTC trip, winding temp gauge trip, bucholz relay, inter trip etc calibration of all the relays complete for time observed with respect to time set primary injection of all the CTs (Periodicity of testing half yearly). Deposite the charges levied / charged by the PSPCL authority for calibration / checking the protection system of 66 KV system all as directed. (b) Greasing / oiling of all the moving parts (c) Operation / working of charging motor and limit switch (d) Any part / spares found defective during testing shall be repared / replaced for which payment shall be made separately against respective items of Sch 'A' (e) Test sheet shall be prepared as specified and made part of RARs & final Bill. (f) The equipments shall be tested twice, 1st test will be carried out within two months from the date of commencement of contract and second test after six months from the 1st test. Payment shall be released on receipt of results/reports from PSPCL
Supply and fixing, in replacement, current transformer CT ratio 600 / 1A, VA 2.5 , 50 Hz class SP, Short Circuit Current Capacity 21.0 KA for 3 sec complete all as specified and directed.
Supply and fixing, in replacement, of contactor for trip / close coil 220 V DC for SF6 breaker compl all as specified and directed
Supply and fixing, in replacement, for trip / close coil 220 V DC for SF6 breaker compl all as specified and directed
Supply and fixing, in replacement,of auxillary switch compl all as specified and directed
Supply and fixing, in replacement,indicator lamp LED type DC compl all as specified and directed
Supply and fixing, in replacement, 11 KV Digital Amp meter 0-100 Amp for 11 KV breaker complete all as specified and directed.
Supply and fixing in replacement Digital volt meter 0-500 Volts working in 220 DC volts complete all as specified and directed.
Supply and fixing in replacement Digital volt meter 0-66 KVolts complete all as specified and directed.
Supply and fixing in replacement Digital volt meter 0-11 KVolts complete all as specified and directed.
Supply and fixing in replacement of safe high voltage tape roll complete all as specified and directed.
Repair /replacement of vacume intrupter / vacume bottle type WL3337925 KA AS PER SAMPLE ALL AS SPECIFIED in Appendix 'B'
Supply and fixing 11 kv BATTERY BACKUPS OF HT VCB 11 KV incl 24 volt DC output battery setting complete all as specified and directed.
Supply and fixing of time trip coil of 11 KV breaker all as specified and directed
Supply & fixing of mild steel chedured plate of 5mm thick or over in thickness of Gde FE 410 WA quality as directed by AGE for using as cable trench plate all as directed
kailu construction co
M/S SATPAL AND BROTHERS
dinesh enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .