Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹32.3 L+₹3,980 (0.12%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹32.6 L+₹33,605 (1.04%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹33.9 L+₹1.6 L (5.07%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹37.9 L+₹5.6 L (17.5%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
27 Jan 2022, 6:00 pmClosed
Garrison Engineers (North) Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
REPAIR MAINT OF CEILING FANS GEYSERS OF OFFRS MD ACCN JCO OR MD ACCN, OFFICE COMPLEX OTM OF BTR DMR AUTO REGT SOTT AND KK RANGES AND REPLACEMENT OF MISC ITEMS OF ACC AND S AND STN HQ UNITS UNDER GE(N) AHMEDNAGAR
2021_MES_498333_1
8587 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D cat b(i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineers (North) Ahmednagar
₹80,000
Yes
7 Feb 2022
30 Dec 2021
29 Jan 2022
30 Dec 2021
27 Jan 2022
13 Jan 2022
Amount
Taking out/down carefully and opening of existing water Geysers of 25 Ltrs capacity,from any position, of any make etc & refixing after reassembling and after repair /replacement of spare parts/ material/items ( such as outer and inner tank) at the desired location and making necessary water inlet, outlet & electric connections to make it functional with including using material/parts of minor nature such as screws, insulation tape, nuts, bolts, washers etc including cleaning and painting with spray painting to required gloss with white synthetic enamel paint on complete body & writing MES No with black synthetic enamel paint etc complete all as specified and directed by Engineer-in-Charge. Note :- Outer and inner tank will be measured and paid separated as supply only under relevant item of this BOQ
Supply and fixing in replacement of base assembly suitable for 25 ltrs capacity geyser with inlet and outlet pipe made out of copper base plate with gasket , proper size of nuts, bolts & washers etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement element 1.5 KW, rubber gasket type with & including rubber gasket complete suitable for 25 Ltrs Geysers of any Make as installed at site etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement element 2 KW, rubber gasket type with & including rubber gasket complete suitable for 25 Ltrs Geysers of any Make as installed at site etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement PVC insulated cable 40/0.0076, 3 core copper conductor cable for connection from geyser to top plug etc complete all as specified and directed by Engineer-in-Charge.
Supply only outer tank sheet cover made of MS sheet suitable for 25 ltrs geyser capacity of any Make as installed at site etc complete all as specified and directed by Engineer-in-Charge.
Supply only inner tank sheet cover made of MS sheet suitable for 25 ltrs geyser capacity of any Make as installed at site etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement safety valve(pressure release valve) suitable for 25/50 ltrs capacity vertical type geyser etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement brass, on return valve 15 mm bore suitable for 25/50 ltrs capacity vertical type geyser of any make as installed at site etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement indicator lamps(set of two -green & red) AC, 220 volts suitable for 25/50 ltrs capacity vertical type geyser etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement thermostat switch , pointer type with adjustable knob, suitable for 25/50 ltrs capacity vertical type geyser & etc complete all as specified and directed by Engineer-in-Charge.
Supply only PVC connection pipe complete with brass end terminal size 300 mm long etc complete all as specified and directed by Engineer-in-Charge
Supply only PVC connection pipe complete with brass end terminal size 450 mm long etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement thermal cut out suitable for 25/50 ltrs capacity vertical type geyser etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement industrial type switch socket for Geysers with 20 Amps MCB etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement 15/16 Amp three pin, plug top, 230 Volts, suitable for 25/50 ltrs capacity geyser complete all as specified and as directed.
Material & Labour for checking the solar water heater for No water in tap,Water not heated at all,although cold water flow is normal,Water not hot enough or sufficient quantity of hot water is not available,Little quantity of boiling hot water is received ,leakge of water from collectors etc and cleaning of Tubes and collectors etc and testing of Solar water heater for desired temperature hot water etc complete all as specified and directed by Engineer-in-Charge.
Taking out/down and opening of existing ceiling fans upto 1400 mm sweep,from any position, of any make etc & refixing at the desired location after reassembling and after servicing/overhauling by thouroghly cleaning the shaft,rotor,stator and applying lubricant/grease to bearings and appllying one coat of super enamelled varnish over winding to improve the insulation resistance including repair /replacement of spare parts/ material/items, (such as bearing & conopy) making electric connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length with & including using material/parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional etc complete all as specified and directed by Engineer-in-Charge. Note:- (i) Bearing & Canopy will be measured and paid separated as supply only under relevant item of this BOQ
Opening of ceiling fans upto 1400 mm sweep, of any make and old type pattern ceiling fan etc from the store yard of AGE E/M , removing burnt out defective unserviceable winding & rewinding with approopriate size of super enamelled copper wire including applying super enamelled varnishing over winding, drying etc, reassembling and fixing after repair /replacement of spare parts/ material/items (such as bearing and Canopy) at the desired location including making electric connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length with & including using material/parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, clamps, washers etc including painting and cleaning the metal surface, greasing/lubricant etc to make it functional etc complete all as specified and directed by Engineer-in-Charge. Note:- (i) Quotated rates include cost for transportation from AGE E/M Store to Worksp & Back. (ii) Bearing & Canopy will be measured and paid separated as supply only under relevant item of this BOQ
Supply only Ball bearing No 6201 etc complete all as specified and directed by Engineer-in-Charge.
Supply only Ball bearing No 6202 etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement capacitor 2.5 mfd, 250 volts , AC etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of rubber reel, bolt, nut including pin etc complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in replacement of electronic fan regulator electronic step up type, SP 230 volt suitable for 48/56 inches fans incl making necessary connections, to make it functional etc complete all as specified and directed by Engineer-in-Charge.
S & F fan Regulator switch type- Dimmer on the existing phenolic laminated etc. as reqd single pole 240 volts grade 100 watts heavy duty ISI marked etc complete all as specified and directed by Engineer-in-Charge Make:- Anchor /Havells /Standard.
S & F Fan regulator 100 W with 360° rotation 2 module etc complete all as specified and directed by Engineer-in-Charge.
Supply only conopy (top and bottom) of ceiling fan , of any sweep, any make etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of down rod 0.45 Mtr long made out of 15 mm bore medium grade GI pipe with & including clamp, nuts , bolts, split pins , washers , threading etc and making connections to make it functional etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of down rod 0.60 Mtr long made out of 15 mm bore medium grade GI pipe with & including clamp, nuts , bolts, split pins , washers , threading etc and making connections to make it functional etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of down rod 1.5 Mtr long made out of 15 mm bore medium grade GI pipe with & including clamp, nuts , bolts, split pins , washers , threading etc and making connections to make it functional etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of down rod 3.00 Mtr long made out of 15 mm bore medium grade GI pipe with & including clamp, nuts , bolts, split pins , washers , threading etc and making connections to make it functional etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of set of blades (set of three) made of aluminium suitable for 1200 mm sweep ceiling fans , of any tint, including provision of brass screws for fixing etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for preperation of ceiling fans upto 1400 mm sweep, of any make by cleaning of metal surfaces and applying a coat of synthetic enemal with spray painting to required gloss with white paint on complete body of fan and writing MES No with black synthetic enemal paint etc complete all as specified and directed by Engineer-in-Charge.
Taking down/out and Opening of existing exhaust fans of 300/450 mm sweep, of any make etc., refixing at the desired location after reassembling and after servicing/overhauling by thouroghly cleaning the shaft,rotor,stator and applying lubricant/grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair /replacement of spare parts/ material/items,making electric connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length with & including using material/parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, clamps, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional etc complete all as specified and directed by Engineer-in-Charge. Note:- (i) The connected items required like capacitor,Bearings,Bush, etc will be measured and paid sperately under respective items
Taking out and Opening of existing exhaust fans 300 mm size, of any make etc from the store yard of AGE E/M , removing burnt out defective unserviceable winding & rewinding with appropriate size of super enamelled copper wire including varnishing, drying etc , reassembling and fixing at the desired location after replacing items/ material including making electric connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length with & including using material/parts of minor nature such as screws, nuts, bolts, washers etc including cleaning the metal surface, lubricant/greasing etc to make it functional etc complete all as specified and directed by Engineer-in-Charge. Note:- (i) Quotated rates inclues cost for transportation from AGE E/M Store to Worksp & Back. (ii) The connected items required like capacitor,Bearings,Bush, Canopy,down rods etc will be measured and paid sperately under respective item of this BOQ
All as per item no. 35 (here-in-before) but of 450 mm size etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement capacitor 3.5 mfd, 250 volts , AC etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement capacitor 4 mfd, 250 volts , AC etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of set of blades made of aluminium suitable for 300 mm sweep exhaust fans, of any tint, with & including provision of brass screws for fixing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of set of blades made of aluminium suitable for 450 mm sweep exhaust fans, of any tint, with & including provision of brass screws for fixing etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for preperation of exhaust fans 300 mm sweep, of any make by cleaning of metal surfaces and applying one coat of synthetic enemal paint with spray painting to required gloss with white paint on complete body of fans and writing MES No with black synthetic enemal paint etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for preperation of exhaust fans 450 mm sweep, of any make by cleaning of metal surfaces and applying one coat of synthetic enemal paint with spray painting to required gloss with white paint on complete body of fans and writing MES No with black synthetic enemal paint etc complete all as specified and directed by Engineer-in-Charge.
S & F Louver Shutter for Exhaust fan 450 mm including fixing with nuts,bolts etc including taking down existing unserviceable Shutters from Bldg at any height etc complete all as specified and directed by Engineer-in-Charge
S & F in replacement Louver Shutter for Exhaust fan 300 mm including taking down existing unserviceable Shutters at any height etc complete all as specified and directed by Engineer-in-Charge
Taking down/out carefully including opening of existing Padestal/wall mounted fans , upto 400/ 450 mm size/sweep, of any make etc from any location , refixing at the desired location after reassembling and after servicing/overhauling by thouroghly cleaning the shaft,rotor,stator and applying lubricant/grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair /replacement of spare parts/ material/items,making electric connection with & including material/parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, clamps, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional etc complete all as specified and directed by Engineer-in-Charge. Note:- (i) The connected items required like capacitor,Bearings,Bush etc will be measured and paid sperately under respective items
Opening of existing Padestal/wall mounted fans , upto 400/ 450 mm size/sweep, of any make etc from the store yard of AGE E/M , removing burnt out defective unserviceable winding & rewinding with approopriate size of super enamelled copper wire including varnishing, drying, cleaning of bearing,shaft,stator,rotor etc , reassembling and fixing at the desired location including making electric connection to make it functional by with and including material/parts of minor nature such as screws, nuts, bolts, washers etc including cleaning ,greasing/lubricant etc complete all as specified and directed by Engineer-in-Charge Note:- (i) Quotated rates inclues cost for transportation from AGE E/M Store to Worksp & Back. (ii) The connected items required like capacitor,Bearings,Bush, Canopy,down rods etc will be measured and paid sperately under respective items
Supply and fixing in replacement of set of blades made of aluminium suitable for Table/ Air circulator fans, of any make, of tint as required including provision of brass screws for fixing etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement energy saving and environmental friendly long life LED street light 25 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 fixed on wall with all fixing accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge. Make -Havell's Cat Part: (ENDURAPEARLSL25W MP) ENDURAPEARLSL25WLED757SASYTOPCMP or equivalent make in list of makes mentioned in appendix `C'
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLS stranded copper conductor cable 4 Sqmm with 4 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. Two run of 4 Sqmm cable i.e for one run for phase, one run for neutral with one run of 4 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit
S&F in replacement energy saving and environmental friendly long life LED street light 35 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 fixed on wall with all fixing accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V , 50 HZ all as etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement GI Pipe 25/32 mm dia B Class bend 1 mtr length as suitable for fixing security light on wall with nut ,bolt and clamp etc complete all as specified and directed by Engineer-in-Charge.
Taking down carefully aluminium point wiring (light, fan, bell, socket, power point etc.) with or without conduit, casing caping, along with all connected accessories such as ceiling rose, switches, sockets, switch boards, fan regulator etc complete all as specified and directed by Engineer-in-Charge
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following, etc complete all as specified and directed by Engineer-in-Charge. Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc
One light point controlled by switch 5 Amp single pole one way
One fan point controlled by switch 5 Amp single pole one way
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts & washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC, both way, lifting arrangement complete including all necessary earth work etc complete all as specified and directed by Engineer-in-Charge.
Notes for Sl Item No.1, 18, 34 & 45 (i) Contractor has to take the complaint at MES power house (E/M) from Concern JE E/M Daily Basis (Except Sunday & holiday). (ii) Contrcator has to attend the complaint within 24 Hrs after recived from JE E/M. (iii) Contrctor has to provide the Mobile no so that massges can be send on the same mobile No. (iv) For non collection of complaits from JE E/M Rs.500/- per day will be charged. (v) For Non attendence of complaints in 24 Hrs Rs.200/- per day per complaint will be charged (vi) Contractor has to return the complaint duly signed from the user with time & date.
An amount of Rs 1,28,992.50 shall be deducted from BOQ on account of schedule of credit
AMAN ENGINEERING AND ELECTRICAL WORKS
Ms. S.K. ASSOCIATES
KAMINS CARE
M/s. N D Karande
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .