Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.6 L+₹2.0 L (7.49%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹28.7 L+₹2.1 L (7.97%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹28.9 L+₹2.3 L (8.63%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹29.9 L+₹3.3 L (12.5%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
14 Jul 2022, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR 208008
REPAIR AND MAINTENANCE OF STREET LIGHTS INCLUDING ALLIED WORKS IN TECHNICAL AREA AT AF STN CHAKERI, KANPUR
2022_MES_531106_1
8579/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
Technical Area under GE (AF) E/M CHAKERI KANPUR
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) E/M CHAKERI
₹60,000
Yes
22 Jul 2022
15 Jun 2022
16 Jul 2022
15 Jun 2022
14 Jul 2022
30 Jun 2022
Amount
Labour only for checking the serviceability of light fittings including lowering down if needed and testing of different spares / components / parts of high mast & security light fittings any wattage/capacity of any description and in any position, checking functioning of contactor, MCCBs and their replacement if found to be unserviceable, regular cleaning of dust & dirt deposit due to natural effects, removal of carbon deposits it any or as direction of Engr-in-Charge. Replacement of un-serviceable/ damaged /broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed. NOTES:- (i) Spares parts/componenets required to make the light fittings serviceable shall be measured and paid for separately under respective item of BOQ. (ii) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc. (iii) Required screws, insulating tapes, internal wiring wire , gaskets, tape insulation and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item. (iv) Taking down unserviceable street/security light fittings of any type,wattage and make from LT/HT poles and transporting from site to MES store yard for repairing in deemed to be included in this item rate. The defective street light fittings will be repaired only at MES yard/place where over directed by Engr-in-Charge. (v) The complain will be communicated to the contractor and the contractor shall rectify the same within 2 Hrs of reporting, failing to which a recovery @ Rs 500/= per complaint per day and maximum of Rs. 5000 /= per day shall be recovered from contractor's payment.
Lowering of high mast light assembly upto 16/12 Mtr high mast, any type, make and wattage, dismantling, checking parts and components for replacement, if required, and making the light fittings operational to give rated illumination incl cleaning of glass cover and refixing the same after repair/replacement of defective components complete with necessary electrical connection with by providing 3 core 2.5 Sqmm PVC sheathed multi stranded copper conductor cable of required length complete all as specified and directed. Note :- (i) Spare parts/components to be replaced shall be measured and paid for separately under respective item of sch 'A'. (ii) The cost of greasing of pully, roller, bearing and gear including refixing of rope clamps, adjustment of lock, lever etc shall be deemed to included the quoted rate. (iii) The complain will be communicated to the contractor and the contractor shall rectify the same within 2 Hrs of reporting, failing to which a recovery @ Rs 500/= per complaint per day and maximum of Rs. 5000 /= per day shall be recovered from contractor's payment.
S&F in repair trailing cable 4 Sqmm, 5 core copper conductor EPR insulated PCP sheathed cable having current carrying capacity 30 Amp complete all as specified and directed.
S&F in repair trailing cable connector and terminal box complete all as specified and directed. Make and Model as per existing.
S&F in repair high mast 3 phase, 440 volt integral motor remote control switch with one No MCB 4 pole, 63 Amp complete all as specified and directed. Make :- As per existing.
M&L in repair welding of High Mast feeder pillar box front/ rear door and locking arrengement including paint patch work making good as per existing colour complete all as specified and directed.
Repair/maintenance and servicing of High Mast raising, lowering assembly with motor and winch of any type and make after dismantling the same from high mast opening it, repair/replacement of defective parts such as bearing, pully, chain etc. After repairing re-assembling, testing and refixing in the existing position complete all as specified and directed.
S&F in repair 60 watt LED lights driver with suitable electronic circuit. The driver should be 140 V to 270 V universal driver with built in surge protection complete all as specified and directed. Make :- Philips / Bajaj / Havells
All as item No 8.00 above but 90 watt LED lights driver complete all as specified and directed.
All as item No 8.00 above but 100 to120 watt LED lights driver complete all as specified and directed.
All as item No 8.00 above but 250 watt LED lights driver complete all as specified and directed.
S&F in replacement LED bulb 15 Watt suitable for Post top lantern complete all as specified and directed. Make :- Philips / Bajaj / Havells
S&F in replacement LED bulb 9 watt, retrofit type complete all as specified and directed. Make :- Philips / Bajaj / Havells
S&F in replacement inverter 12 watt rechargeable emergency LED bulb, retrofit type complete all as specified and directed. Make :- Philips / Bajaj / Havells
S&F in replacement Batten holder for retrofit universal type complete all as specified and directed. Make :- Philips / Bajaj / Havells
S&F in replacement automatic street light switch using nature switch for automatic switching of street lights base on LUX level of Natural light. The infrared sensor based nature switch alongwith suitable power cotactors and MCBs (Input-Output) should be enclosed in pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade thermoplastic polycabonate enclosure conforming to IP-66 protection class 2. The contactor, MCB and copper circuit wiring (min 10 Sqmm) should suitable enough to take 3 phase load of 8kW, contactor rating 25-32 Amps per phase, MCB(SP) rating 32 Amps (3 Nos) complete all as specified and directed. Make: Nature Switch - Philips / Bajaj / Havells Contactor: L&T/Schneider/Legrand/Havells MCBs (input-output) - L&T/Schneider/Legrand/Havells Circuit wiring - Havells / Polycab / Gloster
Repair/maintenance of timer switch assembly of any type and make after dismantling the same from pole, detecting fault, rectifying the same, testing and refixing in the existing position complete all as specified and directed. NOTE :- Parts will be measured and paid separately.
S&F in replacement of Power Timer contactor, 02 pole, 32 Amps complete all as specified and directed. Make :- Legrand / ABB / Schneider
S&F in replacement of Power Timer contactor, 02 pole, 40 Amps complete all as specified and directed. Make :- Legrand / ABB / Schneider
S&F in replacement of Power Timer contactor, 02 pole, 63 Amps complete all as specified and directed. Make :- Legrand / ABB / Schneider
S&F in replacement of automatic street light control switch using infrared sensor based Nature Switch for automatic switching of street lights complete all as specified and directed. Make :- Legrand / ABB / Schneider
S&F in replacement of Automatic operation street light timing switch having lighting control (ON-OFF) through Astronomical Calculation of Sun rise/sun set by setting date, time and degree of longitude and latitude without separate light sensors complete all as directed by Engr-in-Charge. Make :- Legrand / ABB / Schneider
S&F in replacement of Automatic operation street light timing switch having lighting control (ON-OFF) through Dail type timer switch (24 Hours) complete all as specified and directed. Make :- Legrand / ABB / Schneider
S&F in replacement MCB 10 KA capacity having C-curve characteristics connected with suitable lugs, 230 Volts rupturing capacity of the rating SP 6-32 Amps complete all as specified and directed. Make :- Legrand / ABB / Schneider
S&F in replacement MCB TPN 10 KA capacity having C-curve characteristics connected with suitable lugs, 415 Volts rupturing capacity of the rating TPN 32/40 Amps complete all as specified and directed. Make :- Legrand / ABB / Schneider
S&F in replacement MCB TPN 10 KA capacity having C-curve characteristics connected with suitable lugs, 415 Volts rupturing capacity of the rating TPN 63 Amps complete all as specified and directed. Make :- Legrand / ABB / Schneider
S&F in replacement street light junction box (225x295x122mm) comprising four Nos aluminium bus bars of suitable size mounted on epoxy insulators with holes for incoming and outgoing cables, cable gland suitable for pole mounted outdoor type having IP-66 protection complete with FI clamp 40 x 4mm with nuts, bolts & washers including provision for inserting copper cable wires complete all as specified and directed. Make:-Sintex/ Rittal/ Hensel.
S&F in replacement Fire retardant low smoke (FRLS) PVC insulated unsheathed multi stranded single core copper conductor 1100 volts grade conf. IS : 694/1990 of size 1.5 Sqmm fixed street light terminal to over head conductor of suitable length complete all as specified and directed. Make:- Havells / Polycab / Gloster
S&F in replacement PVC insulated wire copper conductor 3 core 2.5 Sqmm connected with street light to junction box complete with suitable for steel tubular pole complete all as specified and directed. Make:- Havells / Polycab / Gloster
S&F in replacement Energy saving & Enviroment friendly LED street light fittings made out of pressure die cast anodized alluminium housing having capacity 60 watt with high efficiency polycarbonate UV stablized cover with integrated lens to ensure asymmetrical light and overall IP protection IP 65 or better complete all as specified and directed.. Make :- Philips / Bajaj / Havells
All as item No 31.00 above but LED street light 90 watt.
S&F in replacement 100 watt LED flood light with high luminus efficacy, protected to IP65 with front toughened glass, with all necessary accessories required effective range including necessary mounting arrangement such as flat iron clamps, nuts, bolts & washers etc complete all as specified and directed. Make :- Philips / Bajaj / Havells
All as item No 32.00 above but LED flood light 120 watt.
All as item No 32.00 above but LED flood light 250 watt.
M&L in replacement for mounting bracket made out of galvanized iron medium grade of 32/40 mm bore of pipe bended into required shape and size of 1.5 mtr including necessary Flat iron clamps made out of 25x4mm flat iron, nuts, bolts & washers suitable for steel tublar pole/on wall and red oxide primer & synthetic enamel painting of clamps, brackets etc complete including taking out old unserviceable brackets complete all as specified and directed.
S&F in replacement for service cable of PVC insulated unsheathed weather proof twin core aluminium solid conductor 6 Sqmm for street light service cable complete all as specified and directed. Make : Havells / Polycab / Gloster
All as item No 36.00 above but cable size 10 Sqmm.
All as item No 36.00 above but cable size 16 Sqmm.
Taking down out carefully old serviceable/ unserviceable LT under ground cable from trench/ floor or fixed on walls or laid in duct/ pipe, any size and core, kept in safe custody for reuse including excavation, returning, filling and supply & fixing connecting materials such as thimbles, lugs, nuts, bolts and washers as required at site ccomplete all as specified and directed. Size of cable:- 10 sqmm, 2 core to 50 sqmm, 3.5/4 core
Re-laying only old seviceable cable retreived under Srl item No.44 above from 10 Sqmm, 2 core to 50 Sqmm, 3.5/4 core complete all as specified and directed.
Supply, laying, jointing, testing and commissioning LT XLPE (in replacement) insulated screened PVC bedded, galvanised steel strip or wire armoured LT 1100 volt grades heavy duty with aluminium stranded conductor cable passing through pipes, induct, on poles, in trenches etc including taking down unserviceable cable complete of following sizes of cable :- 25 Sqmm, 3.5/4 core. Make:- Havells / Polycab / Gloster Note:- The rate of termination and connecting of cable including provinding suitable size and Nos of lugs by crimping as directed and specified shall be deemed to be included in the unit rate.
All as item No 41.00 above but 16 Sqmm, 4 core.
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out, including trimming the sides and forming bottom surface to required levels for fixing pole/stay assembly and laying of cable /taking out cables complete all as specified and directed.
Returning, filling trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding. 50 m and dispositing where directed at a level not exceeding 1.50 m above the starting point complete all as specified and directed.
M&L for sand cushioning in trenches for UG cables protection (8cm deep before laying of cable and 15 cm deep over the cable) complete all as specified and directed. Note :- Punned thickness only will be considered for payment.
M&L for bricks for protection cover to under ground cable (with old size well burnt sub class ‘B’ bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm complete all as specified and directed.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate complete all as specified and directed.
Supply & fixing or laying galvanised in replacement steel tubing medium grade (ISI marked) including fittings such as bend, elbow and sockets etc for protection of under ground cable on poles/ walls under road crossing etc of following sizes including dismantling and taking down existing pipe complete all as specified and directed for following sizes :-. Size of Pipe:- 50mm bore Make:- TATA / Prakash Surya / Jindal
All as item No 49.00 above but size 40 mm bore
M&L for making horizontal boring in any type of soil under road 60cm below the top surface of road complete for passing through 40mm to 50mm dia GI pipe complete all as specified and directed. NOTE :- Pipe will be measured and paid for separatily. Any damage to existing cables of any type will made good by the tenderer without any extra payment.
M&L for straight through joint kit Heat shrinkable type suitable for XLPE under ground cable of size 10 to 16 sqmm x 2/4 core all complete all as specified and directed. Make : Raychem /3M /Denson
All as item No 52.00 above but of size 25 to 50 Sqmm x 3.5/4 core.
All as item No 52.00 above but of size 70 to 120 Sqmm x 3.5/4 core.
M&L for scrapping, cleaning, removing old paint and preparation of steel tubuler pole (9.00 m long) steel fitting complete and applying painting by one coat of aluminium paint after preparation of the steel surfaces including painting to pole with two coat blue & white paint in strap alternatively all round the poles. Hight of the strap shall be 30cm and Nos of strap shall be 05 Nos including writing of pole number complete all as specified and directed.
All as item No 55.00 above above but steel tubuler pole 11.00 m long.
S&F in replacement of MCCB ,4pole, 415 Volt grade, AC 63amp 25KA and Ics =100% of Icu with adjustable thermal release including taking down old unserviceable MCCBs complete all as specified and directed. Make : L&T / Schneider / Legrand
All as item No 58.00 above but 100 Amp.
All as item No 58.00 above but 160 Amp.
M&L for cutting of crawles along the electric pole of any type and height arround the 2.00 m from the pole including removing the crawler from site and depositing at places complete all as specified and directed.
M&L for shifting of street light pole of any size & height to not more than 5.00 KM distance and erecting (PCC 1:3:6 type C2) using 40 mm graded stone aggregate it in ground with proper coping (PCC 1:2:4 type B1) using 20 mm graded stone aggregate and reducing size of pole by cutting it all complete all as specified and directed.
S B ENTERPRISES
VEE KAY ENTERPRISES
DUBEY TRADERS & eNGINEERS
M/s Sohanil Construction
PAWAN COOL CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .