Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC POST BOX NO 539 JUNGLIGHAT P O SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹26.5 L | L1 | Accepted-AOC QUOTED RATE LOWEST AND REASONABLE. |
| 2 | L2₹27.7 LRejected-Finance 3RD FLOOR STAR ENCLAVE GNB ROAD PAN BAZAR GUWAHATI 781001 | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | ₹27.7 L | L2 | Rejected-Finance QUOTED RATE NOT LOWEST |
| 3 | L3₹31.6 LRejected-Finance 44B CIRCULAR GARDEN REACH ROAD KOLKATA 700 023 | KOLKATA | WEST BENGAL | 700023 | ₹31.6 L | L3 | Rejected-Finance QUOTED RATE NOT LOWEST |
| 4 | L4₹34.1 LRejected-Finance 193 E SHANTI PALLI PUSHPAHAR CO OPERATIVE KOLKATA 700107 | KOLKATA | WEST BENGAL | 700107 | ₹34.1 L | L4 | Rejected-Finance QUOTED RATE NOT LOWEST |
| 5 | L5₹34.4 LRejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH PS KHARDAH DIST NORTH 24 PARGANAS KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | ₹34.4 L | L5 | Rejected-Finance QUOTED RATE NOT LOWEST |
| Sl No | Description | Qty | Unit | INDIA ELECTRICAL EQUIPMENTS L3 | RADHA ENTERPRISE L6 | KWALITY CONSTRUCTION L5 | BHARAT MULTITECH INDUSTRIES PVT LTD L1 | Ultimate Solution Company L4 | saitraders L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00NOTE NOS :- The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. | |||||||||
| 2.00 | Supply, install, testing and commissioning of AC 3 phase 50 Hz 315 KVA, energy efficiency level 3 as per IS 1180, capacity transformer step down, indoor type 6600/433 volts (at no load) copper wound, oil immersed, naturally cooled with external cooling tubes, core type, delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol DYN-11 (vector ground-4) with neutral brought on secondary (LV) side & having tapping in equal steps of 2.5% from (+) 5% to (-)7.5% on primary side by means of hand operated off load tap changing gear, so as to change / correct LT voltage on secondary side conforming to IS 1180 Part-I 2014 including provision of all necessary standard fittings and mainly comprising of the following:-
(a) Primary HT side having HT porcelain bushing 3 Nos with brass gun metal bushing rods complete with nuts and washers.
(b) One cable box on secondary (LT) side consisting of 4 Nos porcelain bushings with GM bushing rods complete with GM nuts and washers with one No cable gland suitable for reception of outgoing LT PVC sheathed armoured cables.
(c) Oil conservator with filter type, drain valve and oil level gauge
(d) Dehydrating breather with first fill of dehydrating agent.
(e) Explosive vents.
(f) Thermometer pocket on tank cover.
(g) One No 100 mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device. | 1 | Each | 26,55,200 ₹26,55,200 | 23,00,000 ₹23,00,000 | 24,50,000 ₹24,50,000 | 18,00,000 ₹18,00,000 | 25,50,000 ₹25,50,000 | 17,50,000 ₹17,50,000 |
| 2.02(h) Rating plate with terminal markings. (j)Two earthing terminals on tank / tank cover to facilitate fixing of 32x6m GI / COpper earth strip.(k) Oil level gauge (l) Oil drain and filter valves (m) Lifting lugs - 01 Set (n) Under carriage with 4 Nos of plain rollers (o) First fill of transformer oil and results of transformer insulation oil minimum upto 45 KV with 2.5mm gap. Note:- Transformer shall be fixed on new foundation , the same shall be provide as per manufacturers' recommendation and cost of the same shall deemed to be included in the quoted rate. Accordingly bidder/ tenderer is advised to visit site before quoting his offer and nothing will be paid on this account. | |||||||||
| 3.00 | Supply, install, testing and commissioning of indoor type HT 11 KV panel, 630 Amp load break switch and earth switch suitable for 3 phase, 50 Hz and factory fabricated in an approved factory having modern fabrication process powder coated in approved shard having thickness not less than 100 microns provided with suitable gasket to make it dust / vermin proof. The Air type load break switch a simple and compact construction with epoxy insulators, double switch blades, forged contacts with arc quenching camber, lagging pin and loop less current path and RMU type configurations, complete with tripping initiation by means of fuses, the dry type arc quenching chambers join two switch principle for safe disconnections of heavy and small current, conforming to IS-9920 complet all as specified and directed | 1 | Each | 49,700 ₹49,700 | 8,00,000 ₹8,00,000 | 2,90,000 ₹2,90,000 | 3,20,000 ₹3,20,000 | 3,00,000 ₹3,00,000 | 4,00,000 ₹4,00,000 |
| 4.00 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for taking out pipe line etc for repairs / laying of cables etc and getting out in soft /loose soil complete all as specified and directed by Engr-in-Charge. | 56.7 | Cum | 180 ₹10,206 | 200 ₹11,340 | 300 ₹17,010 | 280 ₹15,876 | 150 ₹8,505 | 350 ₹19,845 |
| 5.00 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed by the Engr-in-Charge | 35 | Cum | 90 ₹3,150 | 100 ₹3,500 | 150 ₹5,250 | 130 ₹4,550 | 80 ₹2,800 | 150 ₹5,250 |
| 6.00 | Removing excavated materiasl not exc 50 mtr and depositing where directed at a level next 1.5mtr above the starting point complete all as specified and direced by the Engr-in-Charge | 22 | Cum | 120 ₹2,640 | 100 ₹2,200 | 350 ₹7,700 | 130 ₹2,860 | 100 ₹2,200 | 320 ₹7,040 |
| 7.00 | Material and labour for Sand cushioning to the full width of trenches for protection of cables including punning down complete all as specified.
Note :- Thickness of sand cushioning shall be the thickness after punning down. | 15.12 | Cum | 800 ₹12,096 | 1,500 ₹22,680 | 1,900 ₹28,728 | 1,900 ₹28,728 | 1,500 ₹22,680 | 1,700 ₹25,704 |
| 8.00 | Material and labour for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified and directed | 6 | RM | 4,500 ₹27,000 | 1,500 ₹9,000 | 2,200 ₹13,200 | 1,900 ₹11,400 | 750 ₹4,500 | 1,500 ₹9,000 |
| 9.00 | Supply and laying unreinforced precast concrete cable cover, factory made, Class HV, type - 1, size 300mmx l80mm x 40mm in trenches for cable protection, embossed with "ELECTRIC" on the top surface complete all as specified and directed. | 778 | Each | 55 ₹42,790 | 65 ₹50,570 | 100 ₹77,800 | 44 ₹34,232 | 25 ₹19,450 | 85 ₹66,130 |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
17 Jan 2026, 6:00 pmClosed
CWE KOLKATA
Headquarter Commander Works Engineers Military Engineer Services No1 National Library Avenue Alipore Kolkata700 027
PROVN OF ELECTRICITY, WATER SUPPLY AND DRAINAGE FACILITY FOR NEW 1.5 TESLA MRI SCANNER UNDER GE(A) KOLKATA
2025_MES_719358_3
C/8403/E-05/25-26
Open Tender
Electrical and Maintenance Works
180 days
GE ALIPORE KOLKATA
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE ALIPORE KOLKATA
₹54,000
Yes
26 Feb 2026
9 Dec 2025
19 Jan 2026
9 Dec 2025
17 Jan 2026
16 Dec 2025
10 Dec 2025 - 13 Dec 2025
NOTE NOS :- The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
(h) Rating plate with terminal markings. (j)Two earthing terminals on tank / tank cover to facilitate fixing of 32x6m GI / COpper earth strip.(k) Oil level gauge (l) Oil drain and filter valves (m) Lifting lugs - 01 Set (n) Under carriage with 4 Nos of plain rollers (o) First fill of transformer oil and results of transformer insulation oil minimum upto 45 KV with 2.5mm gap. Note:- Transformer shall be fixed on new foundation , the same shall be provide as per manufacturers' recommendation and cost of the same shall deemed to be included in the quoted rate. Accordingly bidder/ tenderer is advised to visit site before quoting his offer and nothing will be paid on this account.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for taking out pipe line etc for repairs / laying of cables etc and getting out in soft /loose soil complete all as specified and directed by Engr-in-Charge.
Material and labour for Sand cushioning to the full width of trenches for protection of cables including punning down complete all as specified. Note :- Thickness of sand cushioning shall be the thickness after punning down.
Supply and laying unreinforced precast concrete cable cover, factory made, Class HV, type - 1, size 300mmx l80mm x 40mm in trenches for cable protection, embossed with "ELECTRIC" on the top surface complete all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts Earthed grade , lay in trenches, ducts, along pole, along Transformer cross sectional area 95 sq. mm 3 core complete all as specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_832771.xls
BOQ • 2.53 MB
TENDER_E05.pdf
Tender Documents • 1.14 MB
Download all tender documents and submit your bid