Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹18.0 L+₹58,598 (3.37%)Rejected-Finance VILL PO BUNGWAN KALAN TALBEHAT LALITPUR UTTAR PRADESH 284136 | TALBEHAT | LALITPUR | UTTAR PRADESH | 284136 | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹18.0 L+₹59,855 (3.44%)Rejected-Finance 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L3 | Rejected-Finance Not become lowest bidder | |
| 4 | L4₹18.1 L+₹72,340 (4.16%)Rejected-Finance CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | L4 | Rejected-Finance Not become lowest bidder | |
| 5 | L5₹18.4 L+₹99,280 (5.71%)Rejected-Finance 630 MAIN ROAD BABINA CANTT 284401 TESIL DISTT JHANSI UP | BABINA CANTT | JHANSI | UP | 284401 | L5 | Rejected-Finance Not become lowest bidder |
Tender Value
₹23.3 L
EMD Value
₹46,600
Closing Date
18 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JHANSI
HQ CWE JHANSI
SPL REPAIR/REPLACEMENT OF ASBESTOS CEMENT SHEET INTO GALVALUME SHEET WITH CONNECTED WORKS IN BLDG NO T-1, T-2, T-3, T-4 AND T-1/A-1 OF ZONE 17 AND TP-73/1, TP-73/2, TP-63/01 AND TP-72/01 OF ZONE 9B AT TALBEHAT MIL STN
2023_MES_634041_1
CWE/JHA/TBT/TOKEN/97 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
TALBEHAT
As per tender documents
8 documents required · 8 mandatory
₹500
AGE (I) TALBEHAT
₹46,600
Yes
16 Apr 2024
22 Dec 2023
20 Jan 2024
22 Dec 2023
18 Jan 2024
6 Jan 2024
Amount
Dismantling of AC sheet (corrugated or semi corrugated etc) including AC ridges in large patches as in roof covering complete all as specified and as directed. Note:- opening of existing wind tie where required for taking down of AC sheet is deemed to be included in the rate quoted .
Dismantling of timber fillets , rails, posts, rafters, purlin etc under 40 sqcm in section, in any position in unframed work complete all as specified and as directed.
Dismantling of timber scantling 40Sqcm and over in section in any position such as in rafter, purlins etc in unframed work complete all as specified and as directed
M&L for clean sawn 2nd class hard wood as in scantling any section sectional area fixed to timber/iron frame work complete all as specified and as directed.
Cutting holes into or through brick wall built in cement lime mortar and walls of cement concrete of superficial area exc 150 sqcm but n exc 400 sqcm and making good in CM 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified & directed.
S&F rolled mild steel section work as in main and cross beam, hip and jack rafters purlins where connected to common rafters and running rails fixed with angle cleats or other connecting plates,Wind tie and and similar work confirming to Fe 410W(Gde E-250 quality A) complete all as specified & directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick, Trapezoidal roofing profile with 190 mm Pitch & 29 mm depth of profile of any colour having tensile strength of 550 Mpa fixed with self tapping screws/L-type or J-type or cranked hook bolt as complete all as specified & directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa fixed with self tapping screws complete all as specified & directed.
M&L Preparing surfaces of wood and wood based materials new or old of any description and girth not otherwise described and treated with two coats of creosote oil all as specified and directed.
M&L Painting to new steel and iron surface of any description over 10cm in width or girth not otherwise described with two coats of synthetic enamel paint over coat of red oxide primer complete all as specified and directed
M&L for preparation of old painted steel surface of any description and applying one coat of synthetic enamelled paint complete all as specified and as directed.
Dismantling wall and celling board (fibre, pulp, insulation etc) any thickness including cover fillets complete all as specified and as directed.
M&L of E-boards "Everest " Make 600 X600 X4mm thick, white prelaminated self-embossed reinforced designer ceiling board tiles of approved texture at all height laid on Hot dipped Galvanized iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick GI sheet and of size 24 X 32X 300mm and spaced at 1200mm centre to centre screwed fixed to the soffit of structure by hanger as approved at 1200mm maximum centres. Hangers of GI wire 2 run 4mm dia to be fixed by approved rawl plug, level and adjusters and screws etc. The last hanger at the end of each main runner shall be greater than 450mm from adjacent wall. Flush fitting of 1200mm long cross tee (with double stitching) to be interlocked between main runners at 600mm centre to centre to form 1200 X600mm modules, cross tee longer than 600mm to be supported independly 600 X600mm modules to be formed by fitting 600mm long cross tee centrally between 1200mm cross tee. The perimeter wall angle shall be of 0.45mm thick GI sheet of size 19mm X19mm and 3000mm long of white powder coated all as specified by manufacturer instruction complete all as specified and as directed.
Demolition of stone/ brick masonry built in cement or cement lime mortar as in portion ordered complete all as specified and as directed.
M&L for brick work with old size sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
Taking down cement or cement lime plaster on brick wall, ceiling incl. Raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M & L 10mm thick plaster in CM 1:6 on fair surfaces of walls finished even and smooth w/o using extra cement complete all as specified and directed.
M&L for 15mm thick plaster in CM 1:4 on fair faces of brick work or concrete surface finished even and smooth w/o using extra cement complete all as specified and directed.
M&L preparation new plastered surfaces of wall and providing two coat of cement base paint over a coat of primer complete all as specified & directed.
M&L for preparing of old surfaces of walls by washing rubbing down & stopping of painted surfaces and applying one coat of cement base paint, in any colour complete all as specified & directed.
M&L for preparing of old surfaces of walls, pillasters, cornices etc by washing, rubbing down & stopping etc and applying one coat of oil bound distemper in any colour complete all as specified & directed.
M&L for preparation of old plastered surfaces of wall and applying one coat of weather proof exterior emulsion paint all as specified and as directed.
M&L for preparation of surface 1mm thick wall care putty complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall over a coat of primer on surface and applying two coats of oil bound distemper complete all as specified & directed.
M&L for preparation of new plastered surfaces of wall and applying three coat of white wash complete all as specified and directed
M&L for preparation of old painted surfaces of wood & wood based material of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed.
M&L for Preparation of wood and wood based materials surfaces of new or old, of any description and girth,and applying one coat of Creosote oil complete all as specified & directed.
M&L for Preparation of wood and wood based materials surfaces of new or old, of any description and girth,and applying two coat of Creosote oil complete all as specified & directed.
Demolition of cement concrete of any description and in any position not oterwise specifically provided for complete all as specified and directed.
M&L for providing plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as kerb or benching to wall and similar work complete all as specified & directed.
M&L for preparation of new surfaces of wood & wood based material of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat pink primer complete all as specified & directed.
Taking down carefully copper/Aluminium point wiring (light/fan/socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors etc complete all as specified and as directed.
Taking down Distribution Boards along with MCB's incl removing the same from site and making good to the disturbed surface complete all as specified and as directed. Note: All taken down MCBs should be deposited to MES store by the contractor without any extra charge.
Taking down existing sub main wiring of any type and description including removal of teak wood batten/pipe etc and making good to the disturbed surface complete all as specified and as directed.
M/L for point wiring concealed type with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl FRLS PVC rigid conduit not less than 20 mm dia with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following: Note:- On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit/PVC Casing caping and its accessories.
One light/fan/bell point controlled by one No piano type switch 5 Amps single pole one way
One socket outlet 5/3 pin 6 AMPS controlled by one switch on the same board.
One socket outlet 5/3 pin 6 AMPS controlled by one switch on independent board.
All as per item No 35 above but 3 pin socket out let 15/16 Amps on the independent Board all as spfd with single core unsheathed PVC insulated cable multistranded copper conductor of size 2.5 sq mm for phase & neutral & 2.5 sq mm for earth continuity conductor complete all as specified and as directed.
S&F Switch Piano Flush button single pole one way 5/6 Amp complete all as specified and as directed.
S&F Switch Piano Flush button single pole one way 15/16 Amp complete all as specified and as directed.
S&F socket outlet 2 in 1, 3 pin & 2 pin, 5/6 Amp, 240 volt complete all as specified and as directed.
S&F socket outlet 2 in 1 , 3 pin & 2 pin, 5/6 Amp and 15/16 Amp, 240 volt complete all as specified and as directed.
S&F ceiling rose surface bakelite 65mmx50mm 100watt three terminal complete all as specified and as directed.
S&F step type electronic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S&F Lamp hoder/Batten holder PVC/Polycarbonate insulated body with metal ring and back plate for batten fitting complete all as specified and as directed.
S&F Bell Ding Dong type, AC 230 Volts, Single pole complete all as specified and as directed.
S&F Bell Push, flush type, 5 Amp, AC-230 Volts, single pole complete all as specified and as directed.
M&L for sub main concealed wiring with two single core PVC insulated of size 6 sqmm FRLS unsheathed copper conductor 1100 volt grade multistandard and incl drawn through and including non metallic rigid PVC conduit and conduit accessories of 25 mm external dia and conduit FRLS accessories of ISI marks medium grade including 6.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly. Note:- (i)One run of conduit two run of 6 sq mm copper conductor & one run of 6.0 sq mm copper conductor is measured as one unit. (ii) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit and its accessories.
S&F sheet metal enclosure double door for MCB DB single pole and neutral 8 way with 200 Amps rated bus bar 240 volts double door (Metallic) type complete all as specified and as directed.
S&F MCB SP 5 to 32 Amps 240 volts 'C' series, 10 KA, 50 Hz including connection in the DB and testing/commissioning complete all as specified and as directed.
S&F MCB SPN 40 Amps 240 volts 'C' series, 10 KA, 50 Hz complete all as specified and as directed.
Supply and fixing LED tube lights fitting 1x 18W, 4 feet, 220V,AC decorative rectengular box type with driver, holder including LED light connecting up with flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC rcessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
S&F LED Lamp 9W B22 Type all as specified and directed.
Supply and laying or fixing or passing through pipe in replacement, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1.00 meter apart including 4mm dia suspension wire one twin core cable flat or circular of size 10 sqmm 2 core complete all as specified and directed.
Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in electrical plate No 3 of SSR Pt I including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab framed with 50X30X4 mm MS angle (reinforced with 6 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and magnesium sulphate in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect., GI earth wire protected by 40 mm bore (light grade) galvanized iron pipe and other end connected to the earth bar (test point) made of MS flat (400X32X6 mm) bend in ‘D’ shape and fixed to wall by means of fast nut or bolt grouted in to wall at 1 mtr from plinth height. 4sqmm PVC insulated (colour green) copper conductor single run as earth continuity conductor along with 15 mm PVC conduit grouted in wall or fixed on wall surface to be continued up to main switch board and fix with common earth dolly as directed by EIC . Disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete all as specified and as directed.
M/S A.R BUILDERS
M/S SHIVA TRADERS
HARNAM SINGH ANIL SINGH
R.P ASSOCIATES
M/S ARVIND SINGH THEKEDAR
M/s Dinesh Kumar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .