| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹35.5 L+₹2.8 L (8.49%)Rejected-Finance 127 OLD NAGAR PALIKA BUNGLOW NO 60 NEEMUCH MP NEEMUCH MADHYA PRADESH 458441 INDIA | NEEMUCH | MADHYA PRADESH | 458441 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹35.8 L+₹3.1 L (9.54%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹36.8 L+₹4.1 L (12.4%)Rejected-Finance H NO 496 SECTOR 10 GURGAON 122001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | L4 | Rejected-Finance Not lowest bidder |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
14 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Delhi Cantt 10
Garrison Engineer South Delhi Cantt 110010
Construction of one guard room with attached toilet and bathroom at Mahipalpur gate and guard room with attached toilet and bathroom at middle Shankar Vihar under AGE B/R-II (S) and AGE E/M (S) of GE (South) Delhi Cantt-10
2022_MES_518431_1
GE/DS-14/2022-23
Open Tender
Civil Works
Item Wise
180 days
GE South Delhi Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE South Delhi Cantt
₹76,000
10 Jun 2022
16 Apr 2022
16 May 2022
16 Apr 2022
14 May 2022
30 Apr 2022
60 days
Amount
Surface excavation in hard/dense soil n.exc 30 cm deep and averaging 15 cm deep and getting out, complete all as specified and directed by Engr-in-Charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any type of soil, complete all as specified and directed by Engr-in-Charge.
M&L for plain cement concrete type D-2 1:4:8 (40mm graded aggregate finished as in foundation or sub base, complete all as specified and directed by Engr-in-Charge.
M&L for reinforced cement concrete M-25 design mix using 20mm graded stone aggregate as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, under-reamed piles and mass concrete, complete all as specified and directed by Engr-in-Charge.
M&L for reinforced cement concrete M-25 design mix using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts, complete all as specified and directed by Engr-in-Charge.
M&L for reinforced cement concrete M-25 design mix using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed by Engr-in-Charge.
M&L for reinforced cement cocrete (Nominal mix), type B-1, (1:2:4) 20mm graded stone aggregate, as in beams, cantilevers, linlles over 1.5m span, complete all as specified and directed by Engr-in-Charge.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter for rough finished surface of concrete, complete all as specified and directed by Engr-in-Charge.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions of square, rectangular or polygonal shape for fair finished surface of concrete, complete all as specified and directed by Engr-in-Charge.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surface of concrete, complete all as specified and directed by Engr-in-Charge.
M&L for from work to soffits of suspended slabs such as roof slabs, floor slabs, landing & similar work not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces, complete all as specified and directed by Engr-in-Charge.
M&L for mild steel TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engr-in-Charge.
All as per item No.12 above but 5mm dia and over upto and including 10mm dia in stirrups spacers and binders, complete all as specified and directed by Engr-in-Charge.
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6, complete all as specified and directed by Engr-in-Charge.
M&L for brick work with sub class "B" bricks, straight or curved on plan of any radius in half brick thick wall, built in CM (1:4), complete all as specified and directed by Engr-in-Charge.
M&L for 15 mm thick cement plaster with readymix plaster (as per manufaturer's instruction) on fair faces of brick wall or concrete surfaces finished even and smooth, (without using extra cement) complete all as specified and directed by Enigneer-in-Charge.
M&L for 10 mm thick cement plaster with readymix plaster (as per manufaturer's instruction) on fair faces of ceiling or concrete surfaces finished even and smooth, (without using extra cement) complete all as specified and directed by Enigneer-in-Charge. Note for Srl item No. 16 & 17:- 1. Make of readymix plaster shall be Birla Aerocon/Ultratech readiplast/ACC Accoplast / Fosroc Chemical (India) Pvt Ltd Renderoc and as approved by GE. 2. The readymix plaster shall be procured directly from the manufacturer or their authorised dealer. 3 The contractor shall produced original purchase voucher alongwith test certificate of readymix plaster while claiming RAR/ Final Bill.
M&L for preparation of newly plasered surfaces of walls and applying two coat of cement based paint, complete all as specified and directed by Engr-in-Charge.
M&L for preparation of newly plastered surfaces of wall and applying wall care putty (JK/Birla white) to obtain even and smooth wall surfaces including grinding with sand paper and levelling of surface and applying two coat of oil bound distemper on white or tinted over existing prepared putty base surface, complete all as specified and directed by Engr-in-Charge.
M&L for preparation of newly plasered surfaces of ceiling and applying three coat of white wash, complete all as specified and directed by Engr-in-Charge.
M&L for hardcore of base n.exc 63mm of broken stone or bolder, deposited, spread and leveled in layers n exc. 15cm thick watered and rammed to a true surface, complete all as specified and directed by Engr-in-Charge.
M&L for 75mm thick cement concrete type C-2, 1:3:6 (20 mm graded aggregate) as in plinth protection, complete all as specified and directed by Engr-in-Charge.
M&L for moorum/ red bajri filling in floors or pavings, laid in layers n.exc. 15 cm thick, spread, levelled and rammed including watering, complete all as specified and directed by Engr-in-Charge.
M&L for cement concerte 1:4:8 type D-2, using 40mm graded stone aggregate, of thickness 100mm, as in sub base flooring complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete type B-1 (1:2:4), using 20mm graded stone aggregate, of thickness 40mm, complete all as specified, complete all as specified and directed by Engr-in-Charge.
M&L for first quality non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm, as in floors laid on 15mm thick cement screed bed in CM (1:6), set and jointed in neat cement slurry at the rate of 3.0 kg per sqm and pointed in white/coloured cement to match the shade of tiles, complete all as specified and directed by Engr-in-Charge.
M&L for first quality non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but n.exc 0.11 sqm, as in floors laid on 15mm thick cement screed bed in CM (1:6), set and jointed in neat cement slurry at the rate of 3.0 kg per sqm and pointed in white/coloured cement to match the shade of tiles, complete all as specified and directed by Engr-in-Charge.
M&L for glazed ceramic coloured tiles of 300x450x7mm thick, laid on vertical surfaces such as skirting, dados and risers to steps etc laid over 10mm thick cement plaster in CM (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, complete all as specified and directed by Engr-in-Charge.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed by Engr-in-Charge.
All as per item No.29 above but without glazing bar, complete all as specified and directed by Engr-in-Charge.
S&F Sheet glass 4mm thick, ordinary quality and glazing with oil putty or wooden beads in squares n.exc 0.5 Sqm in each pan, complete all as specified and directed by Engr-in-Charge.
S&F stainless steel wire cloth, 0.63mm nominal dia or wire and sqm average width or aperature 1.40mm, fixed with tinned tacks or galvanised wire staples to doors/steel windows, complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new steel surfaces of any description over 10 cms in width or girth and apply two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed by Engr-in-Charge.
M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar work con- forming to Fe.290. Gde-E-165, complete all as specified and directed by Engr-in-Charge.
M&L pressed steel frames of size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and directed by Engr-in-Charge.
M&L factory made solid PVC chowkhat/door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with 19 mm x 19mm MS square tube of 19 gauge including rubber gasket, PVC fastners, screws, brackets etc. complete all as specified and directed by Engr-in-Charge.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tube for top and bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strips of 20 mm with stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap inserted for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supplying and fixing in the frame at the site as per specification & drawing complete all as specified and directed by Engr-in-Charge.
S&F 35 mm thick Factory made IInd class hardwood plain, framed paneled shutters (any numbe of panels) with lock rail and panel of 9mm BWP commercial ply with commercial veneering on both faces size of rail and stile as per IS-1003 (part) Kiln seasoned and chemically pressure treated, complete all as specified and directed by Engr-in-Charge.
S&F 35mm thick factory made IInd class hard wood glazed and Skelton shutters (three panels) open rebated and prepared to receive glass/gauge etc. divided into squares edges of framing plain, chamfered or rounded mitered and rebated sash bar any number with cut or mitered beads for securing glass/gauge etc. size of members of shutters, complete all as specified and directed by Engr-in-Charge.
S&F mild steel butt hinges, 100 mm, medium weight, cold rolled mild steel, and fixed, complete all as specified and directed by Engr-in-Charge.
S&F stainless steel butt hinges, size 100mm complete, complete all as specified and directed by Engr-in-Charge.
S&F aluminium anodised barrel tower bolts, 150mm long of extruded section and fixed, complete all as specified and directed by Engr-in-Charge.
S&F aluminium anodised barrel tower bolts, 200mm long of extruded section and fixed, complete all as specified and directed by Engr-in-Charge.
S&F aluminium handles, 150mm size, fabricated type, complete all as specified and directed by Engr-in-Charge.
S&F aluminium alloy anodised sliding door bolts of 250mm long with hasp, staple (bolt type) fixing clips of sheet cast or extruded section, fixing bolts and sliding bolts of extruded section and fixed, complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new wooden surfaces of any description not otherwise described over 10 Cms width or girth and apply two coat of synthetic enamel paint over a coat of pink primer, complete all as specified and directed by Engr-in-Charge.
S&F vitreous china wash down water closet pan (pedestal pattern), white including sheet cover of closed pattern with flat bottom and mild steel chromium plated or aluminiumised hinging device, complete all as specified and directed by Engr-in-Charge.
S&F PVC valveless, syphonic action type flushing cisterns 10 ltrs capacity, low level, white, with inlet ball valves, float and handle including brackets and pvc flush pipe 32 mm dia for low level, complete all as specified and directed by Engr-in-Charge.
S&F vitreous china wash basin, white, flat back, size 550 x 400mm, including necessary waste pipe and coupling, brackets and cutting for and pinning in ends of brackets, complete all as specified and directed by Engr-in-Charge.
S&F vitreous china bowl urinal flat back of size 465x355x265mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe), complete all as specified and directed by Engr-in-Charge.
S&F vitreous china urinal partition white of size 310x700 mm, complete all as specified and directed by Engr-in-Charge.
S&F 15mm dia GI tubing medium grade galvanised with all fittings (such as tee, bend, elbow, union etc.) and fixed complete to walls and ceiling or laid in floors etc, complete all as specified and directed by Engr-in-Charge.
S&F 20mm dia GI tubing medium grade galvanised with all fittings (such as tee, bend, elbow, union etc.) and fixed complete to walls and ceiling or laid in floors etc, complete all as specified and directed by Engr-in-Charge.
S&F 500 ltr capacity rotational moulded polyethylene water storage tanks three layer (cylindrical vertical with closed top) hoisted and fixed in position, complete all as specified and directed by Engr-in-Charge.
S&F ball brass valves, high pressure, with of PTMT with epoxy coated aluminium rod & high desity plastic ball ascrewed for iron pipe of 20mm bore complete all as specified and directed by Engr-in-Charge.
S&F gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20 mm bore, complete all as specified and directed by Engr-in-Charge.
S&F PVC connections 450mm long with brass unions at both ends suitable for 15mm bore pipe, complete all as specified and directed by Engr-in-Charge.
S&F 15 mm bore angle valve/ stop valves, cast copper alloy, chromium palted, fancy type screwed down high pressure with crutch and butter fly handles, screwed with iron pipes or for union, complete all as specified and directed by Engr-in-Charge.
S&F bib tap, brass chromium plated fancy type, long body with flange screwed down, screwed for iron pipe 15 mm bore, complete all as specified and directed by Engr-in-Charge.
S&F pillar tap, brass chromium plated fancy type with capstan heads, screwed down high pressure, screwed for iron pipe 15 mm bore, complete all as specified and directed by Engr-in-Charge.
S&F 100 mm bore chromium plated grating including fixing with 1:4 CM to floor/nahni trap etc., complete all as specified and directed by Engr-in-Charge
S&F brass chromium plated overhead shower rose 125mm dia, with revolving joint and shower rod to fixed to 15mm bore pipe, complete all as specified and directed by Engr-in-Charge.
S&F brass chromium plated tubular towel rail, 20mm dia, 'D' type 60cm long between flanges of brass CP, complete all as specified and directed by Engr-in-Charge.
S&F 6mm thick glass corner shelf fancy type with railing and fittings complete of size 25cm x 25cm of best quality (as per sample approved by Engr-in-charge), complete all as specified and directed by Engr-in-Charge.
S&F brass chromium plated soap dish 150mmx150mm, of any type, fixed to plugs with chromium plated brass screws, complete all as specified and directed by Engr-in-Charge.
M&L for 75mm cast iron nahani trap/ floor trap with grating including jointing of waste pipe and fixed in cement concrete type B-1, 1:2:4, complete all as specified and directed by Engr-in-Charge.
S&F 100 mm dia cast iron (Sand Cast) soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to wall or laid in treches, complete all as specified and directed by Engr-in-Charge.
S&F 75 mm dia cast iron (sand Cast) soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to wall or laid in treches, complete all as specified and directed by Engr-in-Charge.
M&L for 75mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured), complete all as specified and directed by Engr-in-Charge.
M&L for 100mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured), complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) pipes, 110mm dia single socketed in any length with rubber ring joints fixed to walls, ceiling or in floor, complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) bends/Tee any radius, 100mm bore, complete all as specified and directed by Engr-in-Charge.
S&F holder bat clamps 100mm bore out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, complete all as specified and directed by Engr-in-Charge.
S&F 125mm x 100mm salt glazed stone ware gully traps square & round mouthered trap 'P' including case iron grating and fixed, including necessary excavation and earthwork, concrete in bed, surrounds, kerbs etc., and jointing to drains in CM 1:1, complete all as specified and directed by Engr-in-Charge.
M&L, Priming roof surfaces and applying water proofing treatment over roofs comprising of the following complete all as specified & as directed:- (a) Applying oil bound bituminous primer at the rate of 0.4 Ltrs/Sqm as per IS 3384-1986 on prepared surfaces. Surface shall be kept free till the moment, the primer is impregnated and the solvent oil in primer is evaporated. (b) Applying one coat of hot straight run bitumen @ 1.20 Kg/Sqm of grade 30/40 confirming to IS-73 (Grade S-35). (c) Laying 3mm thick APP polymeric water proofing membrane of weight not less than 3.6 kg/sqm, black finish reinforced with non woven polyster matt, with a thermo fusible finish, torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer's instruction including preparation of surface. Note :- The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators. The contractor shall give 10 years guarantee for effectiveness of water proofing treatment, 2.5% of work done amount of this item shall be retained from contractors payment for a period of 10 years reckoned from date of physical completion of this work, or in lieu contractor may deposit bank FDR for the said amount for 10 years which shall be released by GE on expiry of satisfactory completion of 10 years period.
M&L for cement concrete tiles 20cmx20cmx20mm thick, machine pressed, set jointed and pointed in neat cement slurry in floors, roof and cut and polished laid over 15mm thick screed bed in CM 1:6, complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) in roof kerbs or mud stop rounded or chamfered and hold fast on edge etc. including necessary form work, complete all as specified and directed by Engr-in-Charge.
M&L for providing and injecting chemical chlorpyrifos emulsifiable for post constructional anti termite treatment along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes, complete all as specified and directed by Engr-in-Charge.
M&L for anti termite treatment of soil under existing floors using chemical chlorpyrifog emulsifiable concentrate @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar (1:2) to match the existing floors, complete all as specified and directed by Engr-in-Charge.
M&L for ready mix cement plaster 15mm thick in on brick or conc surfaces finished even and smooth without using extra cement mixed with by adding permeability reducing polymer Latex @ 400gm/sqm (6%) by weight of cementitious content at time of mixing with water as per manufacturer's recommendations including all levelling the surface, curing etc complete. (water proofing compound to be measured separately). Note : Latex will be measured and paid seperately.
M&L for providing and applying a bond coat of Latex:Water: Cement - 1:4:6 with Latex consumption @100gm/sqm on the brick wall surface by brush as per manufacturer's recommendations including curing, complete all as specified and directed by Engr-in-Charge. Note : Latex will be measured and paid seperately.
Supply only Latex complete all as specified and directed by Engr-in-Charge
Expose the first joint of masonry structure at ground level horizontally. The plaster must be knocked off at least 50 cm beyond the visibly penetrated area. Damaged mortar joints are to be scraped out to a depth of approximately 2-3 cm. Drilling Holes: Drilling holes 10mm diameter in masonary structure along the side of the joint at 45° angle so as to cross the brick/block at the intervals spacing if 15-30cm depending on extent of rising dampness as per recommendation of engineer in charge. Cleaning of holes:- Clean the holes by air blower prior to fixing nozzles. Install Packer injection packers 9.8mm diameter, 10cm long in the holes and tighten. Fix the packer securely using Sikadur 31. Note:- Cutting of Packers: Cut the packers after completion of grouting without damaging structural elements.
Supply and apply of a 3 part, very low viscous, elastic polyacrylic injection resin injection 306 with a versatile and adjustable reaction time having Mixed viscosity : 3-11 M.pa.s at +20 Deg C, Reaction time : adjustable according to ambient temperatrure and execution requirement between 8-50 mins, pH – 9-10, Tested as per Wissbau No. 2002-094-(1A) – Function test with re-injectible hose system. The holes should be drilled until a depth of approx 5 cm (for a 6cm thick wall) before the end of the wall is reached. Pump Sika ® Injection-306 at >20 bar into or behind fissures or into masonry joint which are allowing water to infiltrate into unwanted areas. If voids in masonry being injected contain insufficient moisture to activate the grout inject a small amount of water prior to injecting the grout. When movement stops or injection-306 appears at the next packer move to the next packer and inject. If the dampness is heavy, inject similarly at next joint line, complete all as specified and directed by Engr-in-Charge
Returning, filling in, inluding spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25cm thick each in trenches, after the pipes have been laid and tested, complete all as specified and directed by Engr-in-Charge.
Removing excavated material any type of soil exc 50 m but not exc 250 m deposited where directed at a level n.exc 1.5 m above the starting point for soil, complete all as specified and directed by Engr-in-Charge.
M&L for 60mm thickness Machine pressed pre-cast concrete interlocking paver block any size and shape confirming to IS 15658-2006, M-35 grade with grey cement and no pigment, laid over 50 mm thick sand cushion and including joints filled with sand, complete all as specified and directed by Engr-in-Charge.
Plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping and similar work etc. including weathering, slightly rounded or chamferred angles and throating and provision of necessary formwork, complete all as specified and directed.
Precast reinforced cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in cover slab etc. set laid and dry, including provision of necessary formwork, complete all as specified and directed. Note : (i) Reinfocement shall be measured and paid seperately.
Mild steel of Gde Fe-290 (Gde E-165) as in bend, straps, rungs, handle, holdfast, manhole cover frame and similar small articles, complete all as specified and directed.
Plain cement concrete (1:4:8) , type D-2, using 40mm grade stone aggregate as in concrete bed to drain pipes laid to falls in trenches in any depth including packing under and haunching against the sides of pipes for 150mm bore pipes with concrete after the pipes are laid and tested, complete all as specified and directed.
M&L for SGSW drain pipes 150mm dia laid in trenches and jointed in CM (1:3), complete all as specified and directed.
Plain cement concrete(1:2:4) type B-I using 20mm graded stone aggregate as surface channel/drains inside the manholes and like including weathering, slightly rounded or chamfered angles and throating as directed and provision of necessary formwork to any extent and finished exposed surface even and smooth without using extra cement, complete all as specified and directed.
Extra over surface channel inside of manholes for forming fair finished drains of channels 30 cm inner girth in cement concrete using extra cement inclding forms, moulds, mitred/stopped ends, complete all as specified and directed. (Inner girth only be measured and paid), complete all as specified and directed.
M&L point wiring complete, with stranded copper conductor 1.5 Sqmm nominal area PVC insulated 1100 volts grade FRLS electrical cable in and including concealed PVC medium grade conduit 25 mm bore and sunk in pressed steel terminal boxes of required size factory made with top cover 3 mm thick plastic/laminated sheet of required colour with screwed and cup washer with all accessories including 1.5sqmm stranded copper conductor PVC sheathed cable earth wire to common earth and connected to earth dolly complete all as specified and directed by Engr-in-Charge.
All as per item No 96 above but One 3 pin socket outlet, 5/6 Amps, independent.
All as per item No 96 above but 5 Amp socket outlet on same board.
All as Item No 96 above but for one socket outlet 5/15 Amps on Independent board with cables 2.5 sqmm size for phase and neutral and 2.5 Sqmm for earthing.
S&F switch piano, flush type 5 Amps single pole one way, complete all as specified and directed by Engr-in-Charge.
S&F socket outlet 5 Amps flush mounted 5 pin multi purpose complete all as specified and directed by Engr-in-Charge.
S&F switch piano type 15/16 Amps SP one way complete all as specified and directed by Engr-in-Charge.
S&F socket outlet 2-in-1 (multipurpose) 5pin 6/16 Amps flush mounted type complete all as specified and directed by Engr-in-Charge.
S&F 0-4 step type electronic fan regulators for ceiling fan 1200/1400 mm sweep, 240V complete all as specified and directed by Engr-in-Charge.
S&F ceiling rose surface Bakelite 65x25 mm two to three terminals complete all as specified and directed by Engr-in-Charge.
S&F Wall mounted LED Integrated Batten T-5, 20 Watt-4 Ft White, indoor decorative PVC extruded LED battern-Integrated type complete all as specified and directed by Engr-in-Charge.
S&F Wall mounted LED Integrated Batten T-5, 10 Watt-2 Ft White, indoor decorative PVC extruded T-5 LED battern -integrated type complete complete all as specified and directed by Engr-in-Charge.
S&F building security light fitting 45W LED 5000K new Powder coated pressure die cast aluminium compact LED Street light suitable for pole dia 40 mm of bracket duly fixed with pipe, clamps, nut, bolts & washers etc complete all as specified and directed by Engr-in-Charge.
S&F Exhaust Fan, Metal body, copper wound 300 mm Sweep, with metal louver, grouting in wall with nut, bolts and washers and connecting up with flexible cable from ceiling rose/connection to fan complete all as specified and directed by Engr-in-Charge.
S&F BLDC (Brushless Direct Current) Ceiling Fan 1200 mm Sweep,not less than 350 RPMhaving air delivery 215Cum, high air flow with silence operation, with fully copper winded motor & ribbed 3 Nos A/M blades. The BLDC motor fan shall have 100% rust free blades. The fan shall be BEE 5 Star rating and compliant with IS 374 and making necessary electric connection of suitable PVC copper wire from ceiling rose to ceiling fan, including taking down old ceiling fan and depositing to MES store yard complete all as specified and directed by Engr-in-Charge. Make : Orient/Crompton/Bajaj.
S&F single pole and neutral metal clad sheet steel enclosures with 2 pin and earth plug and socket complete with one number MCB SP 20 Amps as per site requirement of existing type, complete all as specified and directed by Engr-in-Charge.
S&F sheet metal enclosures double door for DBs when MCBs to be used SPN-8 Way, 240V with 200 Amp rated busbar complete as per site requirement complete all as specified and directed by Engr-in-Charge.
S&F MCB SPN of 40 Amp 240 volts B-series with no surge current complete all as specified and directed by Engr-in-Charge
S&F MCB SP 6 to 32 Amps 240 volts complete all as specified and directed by Engr-in-Charge
M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh, 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing as directed by Engr-in-Charge.
S&F water heater storage type (Geyser) of capacity 25 Ltrs, BEE 5 star, metal body, auto cut adjustable temperature, safety valve, thermal cut out input voltage 230 volts including all fittings 4 sets of nut, bolts and washers of minimum dia 10 mm, grouting in wall, 3 core lead cable, Plug top, safty valve, inluding electric and water connection and making good to disturbed surface complete all as specified and directed by Engr-in-Charge.
M&L for cutting the existing GI pipe 50/80/100mm bore and threading inserting Tee/elbow/branch pieces/union/reducer etc all necessary fittings 50/80/100 x 50/80/100 x 20 mm and making leakage proof joints using gasket etc. complete all as specified and directed by Engr-in-Charge
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip armoured, electric power cable (heavy duty ) 1100 volt grade with stranded aluminium conductor of size 10 sqmm, 2 core complete all as specified and directed by Engr-in-Charge.
Supply and spreading fine sand (Jamuna sand) in trenches for cushioning of cable 8 cm thick below the cable and 15 cm thick above the cable complete all as specified and directed by Engineer-in-Charge. Note: After punning down 18 cm shall be measured for payment.
Supply and laying sub class ‘B’ bricks well burnt for cable protections laid flat with length equal to width of brick over cable perpendicular to length of cable complete all as specified and directed by Engr-in-Charge.
Supply and laying galvanised steel tube (GI) light grade of size 25 mm (1.0") bore fixed to walls and ceilings or laid in trenches complete all as specified and directed by Engr-in-Charge. Note:-The rate is inclusive of PCC work and making good the disturbed surface of ceiling ,wall, road etc.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
JINDAL ENTERPRISES
Chaudhary Constructions
P R Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .