GE (AF) Bihta
GE (AF) Bihta Pin-801103
Provn of Revenue and Minor Work at AF Stn Bihta under GE (AF) Bihta
2020_MES_380607_1
8107/BHT/E8
Open Tender
Miscellaneous Works
Item Rate
90 days
Bihta
Please refer Tender documents.
8 documents required · 8 mandatory
₹300
GE (AF) Bihta
₹4,500
Yes
5 Nov 2020
24 Sept 2020
22 Oct 2020
24 Sept 2020
20 Oct 2020
8 Oct 2020
60 days
Amount
M&L for excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cable/foundation of street light pole including getting out in soft/loose soil complete all as specified and directed.
M&L for returning filling in, including spreading, leveling,watering and well ramming in layers n.exc 25mm thick in soft/loose soil, complete all as specified and directed by Engineer-in-Charge
Removing surplus soil to distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for sand cushioning to cable with layer of 8 cm deep before laying the cable and 15 cm depth after laying the cable,and punned down to 10 cm complete all as specified and as directed by Engr-in-Charge. Note : Only punned volume of sand will be measured and paid.
M&L for brick, subclass 'B' well burnt, laid dry flat in trenches for protection of cable with a maximum gap of 10 mm between two consecutive brick over LT cable, complete all as specified and as directed by Engr-in-charge.
Supply & fixing GI tubing 40mm bore medium grade, on poles, under floors, road crossing etc all as reqd at site and as directed by Engr-in-Charge.
Supply, laying & testing of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of 10 sqmm 2 core, laid in trenches ,ducts,encased in GI pipes,fixed to pole /wall,laid under rode ,path,drains,culverts,fixed bare including jointing testing including all necessary electrical connection with suitable size of Al lugs/gland as required completeall as specified and directed.
S & F PVC Junction Box of size not less than 15cm x 12 cm having provisions pre-moulded cable entry and 2 Nos of connectors for connecting the cables, suitable size of cable lux , locking arrangement clips etc complete all as specified and as directed. Make : Sintex
S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 6 sqmm as current carrying conductor and one run of 6.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directed including taking down old one Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
Supply & Fix Bell push - 6 A-SP - 1 way with indicator - 1 module fixing in PVC Box and making necessary electrical connections with the existing system complete all as specified and as directd.
Supply and fix electric gong bell single phase 220/250 Volt AC of size 30cm (12'') including fixing on suitable size PVC board where directed and making necessary electrical connections and testing etc complete all as specified and as directed. Make : Kheraj Electrical Industries (Model No GB-30) or equivalent in Bajaj/Havells
M&L for boring of holes by manually / machine under road, pavement, hard standing by trenches for laying of 40 mm GI pipe for cable laying, complete all as specified and directed by Engr in charge. Note : Cost of GI pipe 40 mm light grade demmed to be included in the quoted rate.
M & L for load testing of Hand Operated /Manual Operated Crane of capacity 5 Ton with 125% load. The testing shall be carried out for the following :- (a) Horizontal speed/min - in normal operation (b) Hoist Speed/min - in normal operation (c) Horizontal speed in micro operation. (d) Hoist speed in micro operation Note. (i) Load testingarrangement shall be arranged by the contractor at site (ii) Pre Minor maintenance shall be carried out (i,e greasing of gear box, checking and testing of internal electrical wiring complete and replacement of minor spares required at site. (iii) Testing result shall be submitted to Deptt duly signed by Testing Engineer, User representative & Contractor). (iv) Testing shall be carried out infront of user representative and Engr-in-Charge.
SANYOG CONSTRUCTION PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .